Loading...
HomeMy WebLinkAboutB17-0066_M-3_05-01_1498500453.pdf ,z,„....„00,,,4, z .,,ec , iv. GENERAL NOTE Graphic Scale �� �''' 1. ALL EXHAUST TO BE MIN. 36" AWAY OPERABLE 0 4' 8' 0, 07 d5 Q WINDOWS. I 2. ALL PEX PIP/NG SHALL BE SUPPORTED WITH HANGERS Scale: 1/4" = 1'-0" 06/26/17 IN ACCORDANCE W/TABLE M2101.9 WITH A MAXIMUM HORIZONTAL SUPPORT SPACING OF 2.67 FEET. 3. REFER TO ARCHITECTURAL FOR T-STAT MOUNTING HEIGHTS. TOWN STAMP KEYNOTES 0MAINTAIN 3' FROM OPERABLE OPENINGS TO THE BUILDING, 10' FROM MECHANICAL INTAKES. 3S O2 3/4" HWS TO BASEBOARD AT LEVEL ABOVE. 9 ® 3/4" HWR FROM BASEBOARD AT LEVEL. ABOVE ® 3/4" HWS TO TOE-KICK HEATER AT LEVEL ABOVE. O 3/4" HWS DN TO BASEBOARD AT THIS LEVEL. O3/4" HWR UP FROM TO BASEBOARD AT THIS LEVEL. D E S I D N O 3/4" HWS/R UP TO SUPPLY/RETURN HEADER INSIDE MECHANICAL ROOM. SEE MECHANICAL PIPING DIAGRAM ON SHEET M-5.01-1. OMAINTAIN 12" BELOW OR HORIZONTALLY FROM OPERABLE OPENINGS TO THE BUILDING, 3' ABOVE -: SO L/c ��4 FROM MECHANICAL INTAKES WITHIN 10' PER MANUFACTURERS INSTALLATION INSTRUCTIONS. 0.0 F y,,,,,,.. 11, OINSTALL MICROWAVE EXHAUST PER MANUFACTURER'S , .j INSTALLATION INSTRUCTIONS. )�� •• . • •r ' MAX. EQUIVALENT LENGTH= 140. FT. ��� � ; EQUIVALENT LENGTH AS SHOWN ON PLANS.: 90 FT. ‘t,! LS1VA1 . 10 PIPING LOCATED IN OVERHANG ABOVE SPACE. INSULATE ALL SECTIONS OF PIPING LOCATED WITHIN EXPOSED OVERHANG. DISCIPLINE STAMP 11 MOUNT ABOVE CEILING. UNIT SHALL BE SERVICEABLE THROUGH GRILLE. 12 PROVIDE 3/4" HWS/R TO EACH ZONE FROM HEADER IN MECHANICAL ROOM. ROUTE HWS/R UP IN CEILING TO ZONES 4,5,6 & 7. ROUTE DOWN THROUGH FLOOR TO ZONES 1,2 & 3. SEE MECHANICAL PIPING DIAGRAM ON SHEET M-5.01-1 FOR BOILER PIPING a terminations for combustion air and exhaust must be code complying 1 per I MC,I PC,I FGC o z c, 0 O E (,_ N a N o - WALL CAP W/ BACKDRAFT N / �O DAMPER / O WALL CAP W/ BACKDRAFT / \ \ DAMPER / IA _ I _ I O - - da ` - - - I - Hi' - = • IrE ..CI, _ < :a, : : �' a► it i �Ya,d •- - a. a-d a ; -'da as a a- - < 3 0, ^ ■ ■I O• O o 1 6' EXHAUST 3/4'HWS I ISSUE - II FROM MICROWAVE O TIlr' . 1 © ® 6"fo NHWS 4 � __ � 1 I O Town of Vail Permit Set 0 1 opojBB N- I 0 - - 1 l 1 I .1 : --p : ® CONSULTANT p I:0 LEL KITCHE 0 v 0 ��aIie. - ■ �� 6SG M cn = MOUNT AT FLOOR O3 ®o 3/4 1 'HWS _ 4 HWS/R BATH I LEVEL BELOW 118 West Sixth Street, Suite 200 ..�, ■ = 2 CASEWORK 8 ''�I— • Glenwood Springs, CO 81601 EB j\��' il cn 3/4'HWS/R Q �`I IHEATINGZONE3. LIVING/DINING970.945. 1004www.sgm inc.comda \ © i CT T 3 -.114� �� • 'I HEAT/NG DES/GN DRAWN BY: IB I II O 1q ` J AREA 550 FT2 "� 1 d -� [ I CHECKED BY: BC .k ■ 1 a HEAT/NG LOAD 11145 BTUH c �� i 3/4'HWR a4- = BB-1,4 & SHEET TITLE ■ WATER ENT 1 2 CAR GARAGE ® 0!I ��� - HEAT SOURCE TK-1 r B HEATING GPM 1 o Io O iIII c �r0TOTAL BASEBOARDBuilding 01 - Unit 2.2A • FT 4& EX j• rTO ZONE 3 ACTIVE LENGTH 14 - Level 1 & Level 2 IA�VEOL il p Mechanical Plans 3/4'hWS 3/4"HWS _- - �-3/4'HWS/R = , Ill I 61 -: = <•9• HEATING ZONE 2: BDR-1 TO ZONE 1 —HWR '_ CONTROL - HEATING DESIGN I TO ZONE 2 LIVING REVISION LVE © cn AREA 180 FT2 CONTROL No. Description Date cr) O 4 T _ HEATING LOAD 3180 BTUH = VALVE cn o ENT' _ ■r BB HEAT SOURCE BB-3 BEDROOM = — -Lc 1 1 CI 11 - HEATING GPM 1 I 3 4'HWR m Q = 7j 1 TOTAL BASEBOARD 6 / ,� v •• ACTIVE LENGTH 3/4'HWS (BB HEATING ZONE 1: ENTRY II n " WALL CAP ADAPTOR. (BB) 1 / a - ��IL , ._,I _ HEATING DESIGN - -; • • � a 10 SCHEDULE ON SHEET 1' ---�I������I --- --- - `III REFER ERV A 110 2 1 I ISI 1 'I INSTALL F/REPLACE VENT PER •v HEATINGLOAD3,710 BTUH O / -- ` '-J M 6.01 1 Lh. , �■■■�MIIIIIIIIIIIIIIIII 1O• �O3 'HWS 2 • 2 �'� ----- J MANUFACTURERS INSTRUCTIONS t o HEAT SOURCE 2x BB-1I I SUPERIOR FIREPLACES e J 1 = \ 3'10 FLUE DRC2000 SERIES. ° •k HEATING GPM 1 T I 0 \ & CA m o WALL CAP. REFER FIREPLACE WALL TERMINATION KIT. t TOTAL BASEBOARD 4 FT ❑ ERV SCHEDULE ON \ INSTALL PER MANUFACTURER'S = ACTIVE LENGTH SHEET M-6.01-1 INSTALLATION INSTRUCTIONS. I SIDEWALL O8 E MAINTAIN 9" MIN. CLEARANCE FROM H o 1 VENT KIT P501 OPENINGS TO THE BUILDING. REFER 5 .k TO ARCHITECTURAL PLANS FOR o FIREPLACE INFORMATION. E 0 c) V I PROJECT NUMBER 2016-453.001 in UNIT 2.2 A - LEVEL 01 - MECHANICAL PLAN UNIT 2.2 A - LEVEL 02 - MECHANICAL PLAN ISSUE DATE 05/24/17 c0 1/4" = 1'-0" 2 1/4" = 1'-0" d N SHEET NO. e o N eO n M -3 . 05-01 N O N M