HomeMy WebLinkAboutB17-0066_P-3_03-01_1498500460.pdf °F I/4 L'14- ec Graphic Scale GENERAL NOTES 0 4 8 1470716 I 1 Scale: 1/4" = 1'-0" 06/26/17 1. DOMESTIC WATER SERVICE SHALL BE PEX TUBING WITH NO JOINTS. 2. SEWER SERVICE SHALL BE PVC DWV PIPE. 3. HORIZONTAL SLOPE OF SEWER PIPE IS %4" PER FOOT 4. ALL VENT PIPING IS TO BE 2-INCH UNLESS NOTED OTHERWISE. 5. INSULATE ALL WATER AND DWV PIPING IN WALLS ADJACENT TO GARAGE AND EXTERIOR WALLS. TOWN STAMP KEYNOTES 0 4'W DOWN TO BELOW GRADE. O PROVIDE PASSIVE RADON MITIGATION SYSTEM; 1-INCH PVC PERFORATED 359 PIPE BELOW PLASTIC VAPOR BARRIER & IN GRAVEL BELOW CONCRETE SLABS-ON-GRADE. CAP 6-INCHES ABOVE FINISHED FLOOR TO ALLOW FOR FUTURE CONNECTION. REFER TO DETAIL. O3 3" WALL CLEANOUT. 04 SUGGESTED ROUTING PATH FOR DCW. INSTALL 4"PVC AS PROTECTIVE D E S I G N SLEEVE FOR DCW PEX TUBING THAT IS TO BE INSTALLED AFTER FOUNDATION WORK IS COMPLETE. REFER TO DCW ENTRY DETAIL. O5 2'W, 3/4'HW, 3/4'CW UP TO KITCHEN AREA. O6 2"V UP. _ >,, O 1-1/2"CW, 1-1/4"HW. =�'.S0 Llc' �►� • •' F M.r . 111 ® 1-1/4'CW, 1?-/W. a �`'' I ® 1-1/4'CW, 1"HW. % ` A, 10 1-1/4"CW, 17-/W. # • . -- .-",' Ft .. 12 2"W UP TO MECHANICAL ROOM FLOOR DRAIN. DISCIPLINE STAMP 13 REFER TO SITE PLAN FOR ADDITIONAL INFORMATION ON NATURAL GAS ROUTING. 14 REFER TO HOT WATER HEATER PIPING DIAGRAM DETAIL. 15 PROVIDE ACCESSIBLE SHUT-OFF VALVE. TERMINATE CONNECTION TO APPLIANCE WITH LISTED AND LABELED CSST. a o 11z O (4 0 �� 1-11B (i 1-1/2"VG ® r T'----- FROM CIVIL. REFER ix I 00 II TO P-2.01-01 3/4'CW DN a N 3/4"CW UP © I 1-1/2" DCW O4 / ( Si ) 4'W DN 2"V UP I 3/4'HW ON d,,?\ (1111) 1HWUP U � L_. ,FP z 4,W cy is, y, d _• °` n" ° ' : r " 1 .� e• ' °, °° , n , ° H , 0 l 1 0, \ 80/ 1_,I - - - T.O. SLAB . -� O - (fly O - 1 2'HW, 4'IN, 1 2'CW DN, - 0 4"W UP - A 35.25' FFE 1,CW ' / / 2"V UP 3/4'CW, r � S 7900'+A I - _ \ 3/4 HW_I/ o_ 4'W (WET VENT) ••- ° �\ G I I -0 • 3'1N 1.E. 2»V ` 3/4'HW ON °'N' [- ISSUE_ �3/4'lVG 3/4'CW °', A: 31.75' �I ISSUE 4'1N UP \ 1 I 3/4"NC UP TO 4'W 1'CW DN ® 3/4'lVG DN 15 N �/4/� 1'RADON I RANGE I Town of Vail Permit Set N —� —� I ��\ v 4"W UP (WET VENT) L _ //- - I - r -11 I 4"W 1/2'HW, 2"W, 1/2'CW — — K�EN — \3 ¢ W O \* '", 1 \ I 1'RADON I UP TO SB-1IIIII C i 0 CONSULTANT / 1'lVG r 3 4'HW,, 1'CW 2"W UP i 0 liftill •00- / G� v —I Bill UP 6SG M ¢'�/` �� o \ 4»W / W® I !!� 77--70 4 W 4 IN UP —� I I _ - 118 West Sixth Street, Suite 200 0-- — ----f--J 1 t o Glenwood Springs, CO 81601 1"CW ,i 970.945. 1004 www.sgm-inc.com 1/2'CW, 1/2"HW 4"W DN, I 2"V • 1/2 HW, 2"W,, 0 1-1/2" DCW UP- WATER 1"NG UP 2"V UP O ® DININ 3 1/2'CW UP g o NT _ � I 2"V UP J i DRAWN BY: TC 11 1 0 ,7/ 2"V i CHECKED BY: JG ° 1-1/2" CW ON I 01./ MECH - 0\ / SHEET TITLE o t• 0 - -C •-ET ��- �_ FD O a 4'w w 1-1/2'CW UP 4'W DN, IF o , 1 (ILD- - O / 1'CW UP Building 01 - Unit 3.2A - o TO MECHANICAL 2"V UP 'Ti ® 4'W 77 ROOM 1'AVG ON 0 / 4"W UP Level 1 & Level 2 0 4'W '/ A Y_r m i 3/4'CW 1/2'C TO TP-1 '// 3/4"NG 2"V ON O 0 0 4"W (WET VENT) Plumbing Plans • 1-1/2" CW DNZ FD TF I ENTRY `1,W C LIVING z °i 2 CAR GARAGE 3/4"HW, 3/4"CW, s BEDROOM 4'W UP • I i• W --�-- \ O REVISION u b No. Description Date aFT7- 3/4"CW ON 5 °, hTO HB-1 a, ISI 0 _ [ m Q FPHB I x Z j _ 3/4"VG UP TO u (r)I HB ti _ 4'W FIREPLACE 15 3/4"NC ON C- 0 0 - ° -; 1.______---TO CIVIL. REFER - _ 0, o TO P-2.01-01. — o CIVIL I.E. c) A: 27.79' N dCS D c U I 1 c) I PROJECT NUMBER 2016-453.001 in (0 1UNIT 3.2 A - LEVEL 01 - PLUMBING UNIT 3.2 A - LEVEL 02 - PLUMBING ISSUE DATE 05/24/17 1/4" = 1'-0" 2 1/4" = 1'-0" d NSHEET NO. Tr co N v O N p_3 . 03.01 n 0 0, M