HomeMy WebLinkAboutB17-0066_P-3_05-01_1498500459.pdf z Graphic Scale '' 0 4' 8' Q07 I mm I Scale: 1/4" = 1'-0" 06/26/17 GENERAL NOTES 1. DOMESTIC WATER SERVICE SHALL BE PEX TUBING WITH NO JOINTS. TOWN STAMP 2. SEWER SERVICE SHALL BE PVC DWV PIPE. 3. HORIZONTAL SLOPE OF SEWER PIPE IS %4" PER FOOT 4. ALL VENT PIPING IS TO BE 2-INCH UNLESS NOTED OTHERWISE. 5. INSULATE ALL WATER AND DWV PIPING IN WALLS ADJACENT TO GARAGE AND EXTERIOR WALLS. KEYNOTES O 1-1/2" DCW UP FROM BELOW GRADE. 3S 9 O 2'W UP FROM BELOW GRADE TO KITCHEN AREA ABOVE. O PROVIDE PASSIVE RADON MITIGATION SYSTEM - 1-INCH PVC D E S I G N PERFORATED PIPE BELOW PLASTIC VAPOR BARRIER & IN GRAVEL BELOW CONCRETE SLABS-ON-GRADE. CAP 6-INCHES ABOVE FINISHED FLOOR TO ALLOW FOR FUTURE CONNECTION. REFER TO DETAIL. O 3" WALL CLEANOUT ........0.0.,„, -; LIC %%4 O SUGGESTED ROUTING PATH FOR DCW. INSTALL 4'PVC AS PROTECTIVE i• M. F M. ,q• SII SLEEVE FOR DCW PEX TUBING THAT IS TO BE INSTALLED AFTER V la 1-• <.+ �+o/ FOUNDATION WORK IS COMPLETE REFER TO DCW ENTRY DETAIL. ® 1-1/2'CW DN. �2040 ..'� i O 3/4'CW, 3/4'HW, & 2'W UP TO UPPER LEVEL WASHER SUPPLY BOX. ,\teplVpj G-- ® 1-1/4'CW DOWN. ® 1-1/4"CW, 1-1/4 HW. DISCIPLINE STAMP 10 1-1/4"CW, 1"HW. 11 1"CW, 1"HW. 12 REFER TO SITE PLAN FOR ADDITIONAL INFORMATION ON NATURAL GAS ROUTING. 13 REFER TO HOT WATER HEATER PIPING DIAGRAM DETAIL. 14 PROVIDE ACCESSIBLE SHUT-OFF VALVE. TERMINATE CONNECTION TO APPLIANCE WITH LISTED AND LABELED CSST. a IX o z O 0 (r FROM CIVIL. E N REFER TO ixP-2.01-01 N I 04 / ® 1-1 2 DCW O5 11 2NG ,1 / (HB) 1 0 N I © 2'W UP 3/4"CW, 3/4 HW ON . 3/4'CWUP 4"W UP 3/P TO KITCHEN I © 1'CW UP 3 4"CW DN © 2"W DN UP TO KITCHEN W I , FPHB 0 _ O 4 it..1 1 — _ ___ _ _�� I1p • BT • C _ T.O. SLAB I 4 0 - - - - J Ili4I IISSUE N A 36.75 FFE ,\ lI2W 3/4'HW D �_ 2"V UP TO 2 lV UP S 7900'+A ri"-- / 3/4"CW / 1/2'CW, 1/2'HW, • 4 3"VTR O 1 I 4•W IE 2 W DN _,_,��_ 11 4 Vy Town of Vail Permit Set ,. 3/4'CW, 3/4'hW UP G A: 33.25' I �' — C Q r — !7 , . � a��"nim N i3/4'HW UP tr 3/4 NG UP TO I i 1M' • 4'W 3/4'lVG ON 14 RANGE 3"V UP 1, I CONSULTANT ‘. r 4 IN UP I .N 4"W UP 2"W _ 6SGM —I�II � 4'W�1 I' �� G _ KITOHEN T 3 ( I II)_ -0 1 o I I 1101 I • _� 4 IN UP (WET VENT),4"W UP (WET VENT I 1'RADON 118 West Sixth Street, Suite 200 1'%V 8 ® �► 3/4"CW,I 3/4"HW UP Glenwood Springs, CO 81601 00 0 I I - 0WOE 3 4"W DN 970.945. 1004 www.sgm-inc.com o � , I •� 1'CW a I I 3/4'CW, 3/4HW I I I I 2"V UP, .:1 OL/— L+ f - —J 4'W, 1/2'CW, 1/2 HW DN ' O \ 3" W\mil DINING DRAWN BY: TC CHECKED BY: JG I I a� IllppEP611 -1 SHEET TITLE o WATEF{ 1-1/2 QVIE ENTRYI I f CW 2 CAR GARAG 1-1/4HW � -( v �� Building 01 - Unit 2.2A - o I 2"W ] _ [ 1- 1II mo• oa 0 _ ,,, �'_' � ILevel 1 & Level 2 Q _ 2"W UP TO FD O I Plumbing Plans o BELOW GRADE I I 2"V UP _� �� I .II o, AIG DN 4,W 1-1/2"UW UP ' . ; TO MECH RM 3/4"NG 9 FD TP 2 1 NG UP 1/2"CW TO TP-1 WI. REVISION TO BOILER 3/4'CW c LIVING No. Description Date 5d1 ,,,,,.:1 1-H— — — —NN 4"W ENTRY 4'W al ` BEDROOM j- 3/4 NG DN 14 m _ x C C j /14=1 ��_ OA'nI ��� 3/4'CW DN FPHB E TO HB-1 - I I 10 un 3 io - TO CIVIL. REFER 3/4NG UP E (7) FIREPL4CE TO P-2.01-01. 0 CIVIL I.E. 1 . ,l, A: 29.68' N d O O V •k 1 1PROJECT NUMBER 2016-453.001 1 UNIT 2.2 A - LEVEL 01 - PLUMBING UNIT 2.2 A - LEVEL 02 - PLUMBING ISSUE DATE 05/24/17 1/4" = 1'-0" 2 1/4" = 1'-0" d NSHEET NO. e co N O N p.3 , 05_01 N 7,- .N M