HomeMy WebLinkAboutB17-0066_P-6_01-01_1498500464.pdf a ec X- PLUMB/NG FIXTURE & CONNECTION SCHEDULE +0 ,t7' UNIT COLD HOT UNIT 2.1 - DOMESTIC WATER SIZING BASED ON IPC 1qo ll TAG MANUFACTURING & MODEL NO: DESCRIPTION LOCATION WASTE VENT WATER WATER F/N/SH REMARKS Demand Total 06/26/17 PLUMBING FIXTURES SCHEDULED ARE TO ESTABLISH ALLOWANCES ONLY. FINAL SELECTION OF Fixture Units Fixture Units WC-1 WATER CLOSET BATHROOMS - - - - WHITE FIXTURES & TRIM TO BE COORDINATED BY OWNER AND ARCHITECT FINAL CONNECTIONS TO BE Description Qty. _ Cold _ Hot Total Cold Hot Total VERIFIED WITH SELECTED FIXTURES. Bar Sink 0 0.5 0.5 0.7 0 0 0 PLUMBING FIXTURES SCHEDULED ARE TO ESTABLISH ALLOWANCES ONLY. FINAL SELECTION OF Bathtub, private 1 1 1 1.4 1 1 1.4 S-1 KITCHEN SINK KITCHEN - - - - STAINLESS STEEL FIXTURES & TRIM TO BE COORDINATED BY OWNER AND ARCHITECT FINAL CONNECTIONS TO BE Bathtub, public 0 3 3 4 0 0 _ 0 VERIFIED WITH SELECTED FIXTURES. Bidet 0 1.5 1.5 2 0 0 _ 0 PLUMBING FIXTURES SCHEDULED ARE TO ESTABLISH ALLOWANCES ONLY. FINAL SELECTION OF Washing Machine, private 81b 1 1 1 1.4 1 1 1.4 TOWN STAMP L-1 LAVATORY BATHROOMS - - - - VITREOUS CHINA FIXTURES & TRIM TO BE COORDINATED BY OWNER AND ARCHITECT FINAL CONNECTIONS TO BE Washing Machine, public 8lb 0 2.25 2.25 3 0 0 0 VERIFIED WITH SELECTED FIXTURES. Washing Machine, public 151b 0 3 3 4 0 0 0 PLUMBING FIXTURES SCHEDULED ARE TO ESTABLISH ALLOWANCES ONLY. FINAL SELECTION OF Dishwashing machine, private 1 1.4 1.4 1.4 1.4 BT-1 BATH TUB BATHROOMS - - - - HIGH-GLOSS FIXTURES & TRIM TO BE COORDINATED BY OWNER AND ARCH/TECT. FINAL CONNECTIONS TO BE Dishwashing machine, public 0 2.8 2.8 0 0 COMPOSITE • VERIFIED WITH SELECTED FIXTURES. Drinking Fountain 0 0.25 0.25 0 0 PLUMBING FIXTURES SCHEDULED ARE TO ESTABLISH ALLOWANCES ONLY. FINAL SELECTION OF Kitchen Sink, private 1 1 1 1.4 1 1 1.4 SH-1 PLUMBING FIXTURE SPECS. & HARDWARE SHOWER BATHROOMS - - - - ACRYLIC SURFACE FIXTURES & TRIM TO BE COORDINATED BY OWNER AND ARCHITECT. FINAL CONNECTIONS TO BE Kitchen sink, hotel/ restaurant 0 3 3 4 0 0 0 SELECTION TO BE BY THE OWNER / VERIFIED WITH SELECTED FIXTURES. Laundry 1 to 3 compartments 0 1 1 1.4 0 0 0 ARCHITECT FINAL CONNECTIONS TO Lavatory, private 2 0.5 0.5 0.7 1 1 1.4 PLUMBING FIXTURES TO BE VERIFIED WITH FURNISH WITH SEDIMENT BUCKET AND 510 NICKEL BRONZE ROUND STRAINER. PROVIDE TRAP FD-1359 FLOOR DRAIN MECHANICAL ROOM - - - - NICKEL BRONZE Lavatory, public 0 1.5 1.5 2 0 0 0 SELECTED FIXTURES PRIMER OF PROSET TRAP GUIDE INSERT FOR ALL INTERIOR FLOOR DRAINS. Service Sink or Mop Basin 0 2.25 2.25 3 0 0 0 Shower Head, private mixing valve 1 1 1 1.4 1 1 1.4 D E S I G I\i WCO WALL CLEANOUT INTERNAL WALL - - - - - - Shower Head, public mixing valve 0 3 3 4 0 0 0 Urinal 3/4 flush valve 0 5 5 0 0 Urinal 1" flush valve 0 10 10 0 0 SB-1 WASHER SUPPLY BOX LAUNDRY - - - - - - Urinal Flush tank 0 3 3 0 0 Water Closet, flush tank private 2 2.2 2.2 4.4 4.4 Water closet, flush Valve private 0 6 6 0 0 FREEZE-PROOF HOSE REFER TO ARCH. PLANS FOR WALL THICKNESS REQUIRED FOR FREEZE-PROOF SHUT OFF .......04,..\\,, HB-1 BIB EXTERIOR WALLS - - - - - VALVE. Water Closet, flush tank public 0 5 5 0 0 :=,.110 L %� Water Closet, flush valve public 0 10 10 0 0 �1 TP-1 TRAP PRIMER MECHANICAL ROOM - - - - - - Water Closet, flushometer tank 0 2 2 0 Cold Hot EnOtry i. �� •. Fa , . 1 s. '+0 _ •: ��. 1 Water Supply Fixture 9 FU 9.4 6.4 12.8 0 ,. r , Demand -gpm 1 24.6 11.8 26.5 . X14�. ' L�' .- � .' 1-Demand based on Table El 03.3(3)of 2015 IPC for either Flush tank or flush valve systems + continuous demand fixtures total demand Pipe Size 1 1/2" 1 1/4" 1 1/2" [ l tPG _ EXPANSION TANK SCHEDULE Velocity-FPS 4.46 3.02 4.8 - Continuous Demand Fixture Cold gpm Hot gpm Total Cold Total Hot Qty (per fixture) (per fixture) gpm gpm DIMENSIONS FACTORY Hose Bib 2 5 10 DISCIPLINE STAMP TANK ACCEPT OPERATING RELIEF MANUFACTURER & PRECHARGE WATER TEMP. Hose Bib (hot & cold) 0 5 5 0 0 EQUIPMENT NO. SERVICE LOCATION VOLUME VOLUME PRESSURE PRESSURE WEIGHT (LB) REMARKS MODEL NO. PRESSURE CO HVAC (GAL) (GAL) HEIGHT (PSI) (LBS) (PSI) DIA (IN) (IN) Total Continues Demand Fixture 10 0 ET 2 AMTROL ST-12-C DOMESTIC WATER MECH. 6.4 3.2 12 16 55 60 150 140 80 ASME STAMPED THERM-X-TROL SYSTEM UNIT 2.2 - DOMESTIC WATER SIZING BASED ON IPC Demand Total Fixture Units Fixture Units Description Qty. Cold Hot Total Cold Hot Total Bar Sink 0 0.5 0.5 0.7 0 0 0 HYDRA ULIC CAL CULA TIONS Bathtub, private 1 1 1 1.4 1 1 1.4ilig PRESSURE LOSS PRESSURE AVAILABLE Bathtub, public 0 3 3 4 0 0 0 (PSI) (PSI) Bidet 0 1.5 1.5 2 0 0 0 Washing Machine, private 81b 1 1 1 1.4 1 1 1.4 PRESSURE AT MAIN - 100 Washing Machine, public 81b 0 2.25 2.25 3 0 0 0 Washing Machine, public 151b 0 3 3 4 0 0 0 P.R.V. SETTING 0 60 psi - 60 Dishwashing machine, private 1 1.4 1.4 1.4 1.4 Dishwashing machine, public 0 2.8 2.8 0 0 P.R.V. PRESSURE FALL-OFF 8 52 Drinking Fountain 0 0.25 0.25 0 0 Kitchen Sink, private 1 1 1 1.4 1 1 1.4 Z "3/4" METER LOSS © 30 GPM 5 47 Kitchen sink, hotel/ restaurant 0 3 3 4 0 0 0 u, Laundry 1 to 3 compartments 0 1 1 1.4 0 0 0o 0 ELEVATION LOSS © 40 FT 30x 0.433(PSI/FT) = 13 PSI 34.0 Lavatory, private 3 0.5 0.5 0.7 1.5 1.5 2.1 Lavatory, public 0 1.5 1.5 2 0 0 0 DESIGN PRESSURE @ FIXTURE 20 14.0 Service Sink or Mop Basin 0 - 2.25 2.25 3 0 0 0 N Shower Head, private mixing valve 1 1 1 1.4 1 1 1.4 REDUCE PRESS. BACKFLOW PREVENTER Ito 42GPM 6 8.0 Shower Head, public mixing valve 0 3 3 4 0 0 0 ICC N Urinal 3/4" flush valve 0 5 5 0 0 N PRESS AVAILABLE FOR FRICTION LOSS - 8.0 Urinal 1" flush valve 0 10 10 0 0 PIPING SUPPLY INFORMATION Urinal Flush tank 0 3 3 0 0 N- Water Closet, flush tank private 2 2.2 2.2 4.4 4.4 a LONGEST RUN TO FIXTURE (FT) 100 Water closet, flush valve private 0 6 6 0 0 Water Closet, flush tank public 0 5 5 0 0 a50% F1TT/NG ALLOWANCE (9 OF NUMBER ABOVE) 50 Water Closet, flush valve public 0 10 10 0 0 z Water Closet, flushometer tank 0 2 2 0 0 TOTAL DEVELOPED LENGTH (FT) 150 Cold Hot Entry Water Supply Fixture 10 FU 9.9 6.9 13.5 E Q. FRICTION LOSS RATE PER FOOT (PRESS. AVAIL.FRICTION LOSS TOL) 0.053 PSI/FTDemand -gpm 24.6 11.8 27 / ) 1 Demand based on Table E103.3(3)of2015 IPC for either Flush tank or valve systems+ - ISSUE continuous demand fixtures total demand Pipe Size 1-1/2" 1-1/4" 1-1/2" N FRICTION LOSS RATE PER 100 FT 5.3 PSI / 100 FT Velocity-FPS 4.53 3.02 4.89 Town of Vail Permit Set N Continuous Demand Fixture Cold gpm Hot gpm Total Cold Total Hot Qty (per fixture) (per fixture) gpm gpm Hose Bib 2 5 10 N- Hose Bib(hot & cold) 0 5 5 0 0 N HVAC CONSULTANT Total Continues Demand Fixture 10 0 a e SG Mcn k UNIT 3.2 - DOMESTIC WATER SIZING BASED ON IPC 118 West Sixth Street, Suite 200 Demand Total Glenwood Springs, CO 81601 Fixture Units Fixture Units 970.945.1004 www.sgnn-inc.com O- Description Qty. Cold Hot Total Cold Hot Total a° Bar Sink 0 0.5 0.5 0.7 0 0 0 DRAWN BY: IC m Bathtub, private 1 1 1 1.4 1 1 1.4 CHECKED BY: JG c Bathtub, public 0 3 3 4 0 0 0 0 F Bidet 0 1.5 1.5 2 0 0 0 SHEET TITLE 0 Washing Machine, private 81b 1 1 1 1.4 1 1 1.4 ci Washing Machine, public 81b 0 2.25 2.25 3 0 0 0 Plumbing Schedules Washing Machine, public 151b 0 3 3 4 0 0 0 cn o Dishwashing machine, private 1 1.4 1.4 1.4 1.4 m Dishwashing machine, public 0 2.8 2.8 0 0 oh Drinking Fountain 0 0.25 0.25 0 0 Kitchen Sink, private 1 1 1 1.4 1 1 1.4 1 Kitchen sink, hotel / restaurant 0 3 3 4 0 0 0 _ Laundry 1 to 3 compartments 0 1 1 1.4 0 0 0 o Lavatory, private 4 0.5 0.5 0.7 2 2 2.8 - REVISION Lavatory, public 0 1.5 1.5 2 0 0 0 Service Sink or Mop Basin 0 2.25 2.25 3 0 0 0 No. Description Date -07 Shower Head, private mixing valve 2 1 1 1.4 2 2 2.8 o Shower Head, public mixing valve 0 3 3 4 0 0 0 1 Urinal 3/4" flush valve 0 5 5 0 0 J Urinal 1" flush valve 0 10 10 0 0 t Urinal Flush tank 0 3 3 0 0 k, Water Closet, flush tank private 3 2.2 2.2 6.6 6.6 t Water closet, flush valve private 0 6 6 0 0 n Water Closet, flush tank public 0 5 5 0 0 W Water Closet, flush valve public 0 10 10 0 0 Water Closet, flushometer tank 0 2 2 0 0 1 C Cold Hot Entry Water Supply Fixture 13 FU 13.6 8.4 17.8 c E 1-Demand based on Table El 03.3(3)of 2015 IPC for either Flush tank or flush valve systems+ Demand -gpm 127 13.7 28.8 vcontinuous demand fixtures total demand Pipe Size 1-1/2" 1 1!4" 1 1/2" 1 Velocity-FPS 4.89 3.51 5.22 o Cold gpm Hot gpm Total Cold Total Hot Continuous Demand Fixture k Qty (p ) (p ) gpm gpm (per fixture (per fixture Q Hose Bib 2 5 10 0 Hose Bib (hot & cold) 0 5 5 0 0 HVAC PROJECT NUMBER 2016-453.001 h Total Continues Demand Fixture 10 0 N- ISSUE DATE 05/24/17 I CO O N SHEET NO. CO- N P-6 . O1 -01