HomeMy WebLinkAboutB17-0066_S5.01-1_1498500436.pdf 0 OF 10 Sr %:41tor -yi Z' 4. 6 .1 ri7 ,Th icroJ'a / SEE SLAB STEP DETAILS FOR REINFORCING AT ►� CONTINUOUS TREATED 2x6 �L' osizsn7 STEP :' 1 EACH SIDE W/5/5'0 ANCHOR �� � BOLTS ® 42" O.C. 11 MODULAR BEARING 'f MODULAR BUILDING --�� SLAB ON GRADE PER PLAN j .1 CONTROL JOINT w= WALLS ABOVE 1-.. • 1 ABOVE �� �1 N xa 11 F F j ILS , m a T. SLAB TOWN STAMP h1 h1 r' I ES_ PER PLAN w 1 111A1 Wwg1 Lca v'w; :� FRAMING CLIPS OR �; FRAMING CLIPS OR cn a w l�J� VAPOR BARRIER \ oirli . T. SLAB h1 h1 \/\ � �� ATTACHMENT PER ��1 ATTACHMENT PER `. X ° ,r a \ \ AND INSULATION PER PLAN : �� MODULAR BUILDING �:1 MODULAR BUILDING o ° /\/��/ PER ARCHITECT \ T. PLY 1 �1 DESIGN T. PLY X11 DESIGN _I °�.. .° \�/\�/\�/ o •a e j ,•S •° 111'-0" j 1 111'-0" 3 5 9• \ � \\ \\ \ \\\ REINFORCING PER CONTINUOUS SEE TYPIAL FOUNDATION AT FOOTING SCHEDULE DEMISING WALL OR MARRIAGE LINE TOIL' III _ MODULAR T.O.LL' l'T II MODULAR \�� \ \\��\\\\ \\�\� DETA/LS FOR FOOTING SIZE AND ////////////////// REINFORCING INFO 109'-11 %2" iN 61 SITE-BUILT 109'-11 %2" SITE-BUILT ���\\\\r�/�\//\//\//j;\/ NATIVE GRADE OR COMPACTED 1, 1, STRUCTURAL FILL PER GEOTECH illo .1 TYPICAL FOUNDATION AT MARRIAGE D E S I G N 1 2x 10 TOP » 411, ", PLATE AND DEMISING WALLS W/ <3 STEP 71,4 1 DOUBLE 2x6 A T SLOPED GARAGE SLAB TOP PLATE2x4 PLATE EACH SIDE TYPICAL FOUNDA TION AND BEARING WALL DETAIL A T (:I) SCALE: %2" = 1'-o" A EACH SIDE DEMISING WALLS W/ SLAB STEP BETWEEN UNITS I, 1S5.01 SCALE. 1/2" = 1'-0" .........0 p4 Llt 6-`'`4. ` 1 11 /M i. : N E•PART• II 1 �� ' .:off •�. 40 .1 , , b l.) _mo. :A SEE SLAB STEP DETAILS ; 33878 �� FIRE RETARDANT TREATED 7/16" FOR REINFORCING AT +� 0 4/2 6/17r ,-.1 11 STEP 2x6 STUDS 16" 0.C. W/ GWB •®• • , 1� PLYWOOD OR OSB AS TYPE PER ARCHITECT 114 • .......0.%-i/5. 1 'j SW-3 SHEAR WALL, INSIDE FACE s % Ss; 1 �1 OF EACH WALL m= ‘, ��A�'� h. T. SLAB wc_) ) 1 2x6 STUDS EACH SIDE © 16" (2)-2x4 STUDS © 12" O.C. OR m _ 'Iv' PER PLAN $ DISCIPLINE STAMP 1 O.C. 2x 1 o STUDS 0 16" 0.C. g w ► CONTINUOUS TREATED 2x TL' W/ 1 II cn m ► 14 CONTINUOUS 1/2"0 ANCHOR BOLTS © 72" 0.C. 41, 41 INE.E44�� a wiz �� II /- SLAB ON GRADE o ° J a w m CONTROL JOINT 11 h PER PLAN A -1�.4 CONTINUOUS TREATED 2x6 LL' CONTINUOUS TREATED 2x4 TL' EACH -,I • a .a SEE SLAB STEP DETAILS J T. SLAB 41 1 EACH SIDE W/5/B'0 ANCHOR SIDE OR 2x10 LL' W/ (2) - %2' `� FOR REINFORCING AT \ PER PLAN 1 BOLTS © 32" O.C. ANCHOR BOLTS © 72" O.C. STEP \ " I' A 1 SEE TYPICAL FOUNDATION AT o 27 �j CONTROL JOINT CONTROL JOINT DEMISING WALL DETAIL FOR -I . . VAPOR BARRIER SLAB ON GRADE 1 I�� SLAB ON GRADE FOOTING SIZE AND REINFORCING > ( ‘ �<<� /\\/\\/\\/�AND INSULATION PER PLAN 1 A PER PLAN 1 �1 \ \ \ \/\ \ \ \ \ \ //\//\//\/ PER ARCHITECT T. SLAB X - VAPOR BARRIER T. SLAB X i //////\/�/ /\./\_,/ / /\ !y / \\\\\\\ \ \ \ \ \ \ \ \ \ VAPOR BARRIER \ \ \ \ / /\/\ \/\/\/ PER PLAN = I ,a AND INSULATION lig ° AND INSULATION PER PLAN = a / ' /\P\?�//\ \ \ �r///ii/i/ J /////�//�%//1��� PER ARCHITECT T ///////////t • ° // PER ARCHITECT //\/\/\\/\\/\\://-\ \\\\\\/\\\\\\\\/ REINFORCING PER CONTINUOUS ��� -� / / \�j\\j\\j\\j\\ \ \ \\j\\j\ \ FOOT/NG SCHEDULE �\\\\\ j\j\/,// /\\j• REINFORCING PER FOOTING `�//�//�////�//' \//\, REINFORCING PER CONTINUOUS /\/\ ///////\/j///// / / / / / \ \ \ . �\ \ \ /\\� \\//\\/�� NATIVE GRADE OR COMPACTED \j�\///\/ /�j /,/,\ \//\\//\\\\ SCHEDULE \\•/\\\\%\\\/\����\�\�\\�\\\ FOOTING SCHEDULE TYPICAL FOUNDATION AT DEMISINGSTRUCTURAL FILL PER GEOTECH 1 0 1 o \ \\/\\ /''i/� .\\!��,\\,/, WALLS W/ SLAB STEP BETWEEN UNITS 2 -0,�.//\\�/\�/\\� NATIVE GRADE OR COMPACTED NATIVE GRADE OR COMPACTED STRUCTURAL FILL PER GEOTECH STRUCTURAL FILL PER GEOTECH AND W/ <3 STEP AT SLOPED X GARAGE SLAB 5.01 SCALE: 1/2" = 1'-o" TYPICAL THICKENED SLAB FOUNDATION AND Z 6 INTERIOR BEARING WALL DETAIL 0 TYPICAL FOUNDATION AND BEARING WALL DETAIL TYPICAL FOUNDATION AND BEARING WALL DETAIL S5.01 SCALE: %2" = 1'-0" OAT DEMISING WALLSAT MODULAR BUILDING MARRIAGE LINESCALE.• '-0" 55.01 SCALE.• igt 7 ,--Th I ___, ci.) 7------- . 1I 1� 11 MODULAR BUILDING 11 h 1 MODULAR BUILDING �w CONTINUOUS OSB OR PLYWOOD ABOVE 1 CONTINUOUS OSB OR PLYWOOD MODULAR BUILDING �1 ABOVE F1 ABOVE �O CONTINUOUS OSB OR PLYWOOD SPLICE OR FRAMING CLIP �I SPLICE OR FRAMING CLIP ISSUE 1 SPLICE OR FRAMING CLIP ATTACHMENTS PER MODULAR 4 ATTACHMENTS PER MODULAR � /--1‘ ATTACHMENT T TACHME T S PER SIGNERMODULAR BUIILDING DESIGNER �I BUIILDING DESIGNER h-1� � Structural Roof and � T. PLY -� Foundation Plans T. PLY �, T. PLY 1 SECOND 2x6 PLATE, LAP TO LOWER 111'-D" HSS COLUMN PER PLAN S1 ►- SECOND 2x6 PLATE, LAP TO LOWER 111'-0" PLATE W/ (2) ROWS OF 16d NAILS 2x6 STUDS © 16" O.C. W/ � 111'-0" PLATE W/ (2) ROWS OF 16d NAILS 10" O.C. M ? KEY PLAN 10" O.C. f . ? T.O.LL' I / /s" PLYWOOD OR OSB SHEATHING W/ 8d NAILS T O•R I. 109'-11 % 109'-11 /2" ALONG ALL PANEL EDGES © BASE PLATE AND ANCHOR 109'-11 %2" _- °" i BOLTS PER PLAN AND BASE • ° 4" O.C. CI_ctz PLATE SCHEDULE • �, w ° �� i' j / cL SLAB ON GRADE / \�\/ / \ j\\\ \\\\\\j\\ ( a 1 CONTROL JOINT \//�//\/\/\ (2)-15's \/\ / �CONTINUOUS PRESSURE PER PLAN /\\\\\\\\/ CONTINUOUS PRESSURE CONTINUOUS AT a. /\\//\//\//\//` TREATED 2x6 PLATE W/ y ;. \ \� TREATED 2x6 PLATE W/ ° / 1 / j TOP OF WALL j\j\j\j\j 5/8'0 ANCHOR BOLTS 0 / \ T. SLAB 5/s'o ANCHOR BOLTS © s /\\//\\//\\//\ 32" 0.C. 1 ° - - - , PER PLAN / / / /% 32" O.C. ^ �//\�//\�//\ \ ' ° ° \\ \ \ CONTINUOUS PRESSURE ° ° r ° �� �/�//�//� ,/\\�/\/ /% i VAPOR BARRIER �hk� \j\\j\ jy\/ \ TREATED 2x6 PLATE W/ i T.O.W. A° ° ° ///\// / i ° ° \\� AND INSULATION .^ /\/��`�\ ° \% % %\ 5's ® 12" 0.C. HORIZONTAL 5/8' ANCHOR BOLTS / PER PLAN w / // // /\,/4 / ° a //\/ # PER ARCHITECT SHEET TITLE \ \/\/\ 5 s ® 12 O.C. HORIZONTAL %\/\/\/\� / // \\ \\ \\ \/\\/\\ \� /\\/\\/\\/\ REINFORCING OUTSIDE FACE, PLACE 32" z D o \ 'i / / / / / / / / / / / / / /. • °• \ �, REINFORCING EACH FACE, PLACE %\//\//\//\//< INSIDE VERTICAL REINFORCING i o0 �'w \\\\\\\\\\\\\ \\\� \\ \\\\\ \\\ \ \\\\\\\\ REINFORCING PER FOOTING / INSIDE VERTICAL REINFORCING n/ /5's 0 16" O.C. VERTICAL w= //////// �'� / �\ SCHEDULE \ , ° ,\\,\\,\\,\ I / \\/\\/\\/ \\/\\/�/\\/\\ \/\/\ \/\� Building 1 - Foundation /\/\/\/\/\ /y\/\/\/\, i REINFORCING, OUTSIDE FACE N i////// /////// // / / // \\ \ \ \ \ �\/\\/\\/\\/� #5's © 16" O.C. VERTICAL (2)-#5's �/\/\ ' ' / • /jjj / #5 s 8" O.C. VERTICAL ° �j/n//\//\//\/\ % //\/\//\//\\//\\//\\/\\//\\/\\/\\//\\/� Details \/\/ �� /\/\/ / , REINFORCING, OUTSIDE FACE CONTINUOUS AT / j,/ / \\/\\i\/\/\/\/\/i\/,\//\r ° ► /// REINFORCING EACH FACE ///`,/\ ///\/ TOP OF WALL ° \\/\\/\\/ /\ NATIVE GRADE OR COMPACTED \\/\ \/ ° 0^ \/\/\\/\� ° //\ 7/ / � INSULATION AND ° ° '' ////\//\//\//\ ° • % / / / INSULATION AND = /\/\/ \\/\ STRUCTURAL FILL PER GEOTECH /\/\/\/\/\/� %\/\/\/\/\� /\/\/ \/\/ WATERPROOFING PER • ° I /\j\j\j\j\/ INSULATION AND a /\\j\\j/\\j\ WATERPROOFING PER 4 \\//\\////\\//\�• ARCHITECT \/ \, WATERPROOFING PER !\/\\/ / �/\ 5's © 12" O.C. HORIZONTAL \/\/ ' as /\//\/ ///// �/ //\/\ ARCHITECT # \/ \\/\\/ \ ARCHITECT / / REINFORCING OUTSIDE FACE, PLACE ///// / a� %/////\//\//\//\//\ ; /\/\/\/\/\, / \/\/ /\/. STANDARD HOOK AT \/\/\/\/\/\/\/ /\// //\//\//\//\ STANDARD HOOK AT INSIDE VERTICAL REINFORCING �a ,„ \ \ /\\\ a •.° . //\\\//\//\//\//\//\\ STANDARD HOOK AT /2" EXPANSION °d /\/ �y/\\j/\\j/\\� ° V//\\//\\//\\/s ALL VERTICAL 1" d , 4, \/\\/\\/\\/\\/�� JOINT MATERIAL °/,e"//\ y\/\/\/\ ALL VERTICAL /\// ///\//� REINFORCING TYPICAL THICKENED SLAB FOUNDATION A T STEEL REVISION —� ° /.\/\//\//\//\//\i ALL VERTICAL // //\//\//\/ REINFORCING 1/2" EXPANSION /\\ \\/ %2" EXPANSION JOINT CLR. %n/\/%/%///<1'.� REINFORCING SLAB ON GRADE jj\//\\/\\/\//\/� JOINT MATERIAL \/j//\�/j\�/j\�/j, C-6) COLUMN SUPPORT MATERIAL , /° PER PLAN • CONT/NUOUS LONGITUDINAL5.0SCALE: %2" = 1'-0" o� 1 -p \\\/\\/\\/ Oe/\\/\\ j\\/j\\/j\\j / /\ CONTINUOUS LONGITUDINAL SLAB ON GRADE / //\/�\/\/ j/ REINFORCING TOP & _ SLAB ON GRADE //j//j//j/// //\//\// - CONTINUOUS LONGITUDINAL //\//\//\/// //\ REINFORCING TOP & PER PLAN \ /\\/ / \'< ' PER PLAN ° %\j\j\ j\\j\\j� REINFORCING TOP & a. j /j// BOTTOM PER SCHEDULE /`��"�\i/j/ //�// BOTTOM PER SCHEDULE m • <. \/\//\//////\\//\\/// BOTTOM PER SCHEDULE / /V BOTTOM VAPOR BARRIER 8» -/5 // // /\/ / x /\//\/ / //\//\/// . VAPOR BARRIER /\// / /\/�j \\/ /\\/ /\\/.'/ \/\/ / /\/\/ /\/ / /\/�/\/ AND INSULATION � /\/ /\ /\i z VAPOR BARRIER /\\/ / /\\/\\/\ i AND INSULATION /\\ / /\/•./ \ / / / /\/�C/\//\/. TRANSVERSE o AND INSULATION \// /\/\//\\//\\//// /\\' PER ARCHITECT ° // // /\// //\// TRANSVERSE PER ARCHITECT �\ / , /\\/\\/\ a /// // / / /\/ \ \ \ r /(// / REINFORCING TOP & PER ARCHITECT •• ° • a • / / / / // / / TRANSVERSE / // // , REINFORCING TOP & /�O\\/\\/ /�� \\\ \\\\\\ \\\ \\\ REINFORCING TOP & T SLAB \\/ /// \\�\\/' // /// /////// /, BOTTOM PER SCHEDULE .) fr ////////////// /,// PER PLAN • // / /// / /// / BOTTOM PER SCHEDULE \ \' C ////j�//�///�/////�///\j\BOTTOM PER SCHEDULE ///// / // _. //_� //% /%\/ �./�/ �/// //\ \moi v�i �-� /\\j\\j FOOTING DRAIN • o ,,,/,//�, /,/, ,,//,/, , /,//›i ////////////// s%////////////////////:%////////; r . —/r —s %\\//\\//� �f�\�f7 7�f7/7 \ \\ " \/rifir /\//\//\ PER CIVIL 0 d Zip/\/\ I\\\j\\j\\j\\j\\/ .a '1 a 4 a \ ; \\/\,/f/j\\j\\j\\ /' • '' °.a ' % \\j\ // / ' a ° ° . G// j, m /. �/ / / / / / j � ° / a ��\�\�\/;\\;\\�; \ - ° \% �%���%�(���=m —11—m—_ i?1—m-1 O%�� '-1 11=1 11=1 11=1 11=1 I I—I 1=1 11=11 1=1 1=1 �I 1=III-1 1=1 1=1 1= 1I I-1 ff=111 11=m=m=HT1=111- -111=1 -m=m=m=m=m= f I I-1 1=111-111-111-111-111=1 111=1I1=1I I— =1I1=1I I-I I11I1=1 111. 1111111 1- I1=1 1= I' I -1I1= -_ ' - — 1111�111111=1111�II I II I I,;,I I I i i-111=11 I iI 1111 1111111 I I�III=11111 R111F111 _I / 8 H 111 %- I I-1 11=1 11= — — FOOT/NG DRAIN — TOE RE: SCHEDULE-11I I 1 — — ;12 _ = PER CIVIL / / 8 _, 1=Tii.. i I - III III— _ FOOTING DRAIN _ ' — - � � — I I— —III TOE RE: I _-IIIIII=_- ul " III III—III- / /1 -0 f 1 —III—III—III III— �j1 PER CIVIL SCHEDULE NATIVE GRADE OR NATIVE GRADE OR COMPACTED TOE RE: SCHEDULE / / NATIVE GRADE OR COMPACTED / / STRUCTURAL FILL PER GEOTECH / CONTINUOUS FOOTING, WIDTH PER PLANS COMPACTED STRUCTURAL FILL PER GEOTECH STRUCTURAL FILL CONTINUOUS FOOTING, WIDTH PER PLAN CONTINUOUS FOOTING, WIDTH PER PLAN PER GEOTECH PROJECT NUMBER 2015-453.001 ISSUE DATE 04/25/2017 7 TYPICAL FULL HEIGHT 12" RETAINING WALL FOUNDATION 8 TYPICAL FULL HEIGHT 8" RETAINING WALL FOUNDATION g TYPICAL PARTIAL HEIGHT 8" RETAINING WALL FOUNDATION S5.01a. SCALE: %2" = 1'-O" 55.01 SCALE: %2" = 1'-0"= 1SHEET NO. aS5.01 SCALE: %2" '-0" FOUNDATION N N. 01 N PERMIT SET ■ 71