HomeMy WebLinkAboutChamonix Air Infiltration Testing Report - Unit 1.pdf Hoff 39 N[RGy formerly ACTIVE ENERGIES_ Chamonix Development - Building 1, Unit 2.1 A Air Infiltration Report 401 UTest Date: December 22, 2017 1 \ Builder: RA Nelson � � Contact: Jason Kiefer — .„,rk Site Address: 2310 Chamonix Road, Vail, CO 81657 Site Visit By: Jason Weingast Background The project goal is to undergo testing at the final point in construction to determine if the unit meets the 2015 IECC requirements for infiltration. Active Energies was contracted to perform a final blower door test to determine total air infiltration. The home is permitted under the Town of Vail and requires blower door testing per the IECC. The blower door testing must show a tested value of 3 ACH50 or lower in order to comply with the IECC. Site Observations Construction of the building envelope was complete. All exterior openings were shut and locked and interior doors were open. Cover plates on electrical and AV boxes were partially installed. The ERV was left in the off position, but intake and exhaust were uncovered. The blower door test was performed in the garage man door of the unit. The pressure probe place outside. Blower Door Test The unit was depressurized, utilizing blower door testing equipment to a pressure of-50 Pa. At the test pressure, the CFM50 was recorded, in order to determine the ACH5o. The blower door air leakage resulted in the following measurements: 2.9ACHso Page 1 of 4 12/27/2017 P.O. Box 1434,Edwards,CO 81632 P: 970.306.4237 P: 970.446.4984 NORTPENFRGY ACTIVE ENERGIES.. Recommendations The unit passed, but it was very close. To help increase air tightness for the future units, please see the identified areas for improvements below. 47.5 °F ER .1 11114 ii . 1 . j . . li _. .. 42.4 Install all cover plates and add a gasket or foam to reduce air leakage. 63.9 °F i fir: 1 . ; _F- -; 74.2l - BA— 4 ! till : .ice '_ 1.' S� mow i 58.4 4 1 _L)1 i,,.II A I . . 0_ ,.-•-•=f-'-.- - Filj.-": 1',. 1211, Ensure weather stripping at doors and windows are properly adjusted. Page 2 of 4 12/27/2017 . P.O. Box 1434,Edwards,CO 81632 1 P: 970.306.4237 1 P: 970.446.4984 NORTPENFRGY ACTIVE ENERGIES.. 75.2 ' I .8 OR67.8 The insulation in this corner seems to be compromised. There may be an exterior penetration or other infiltration point allowing air into the corner wall assembly. This may be hard to identify as the units are pre-built. .54.0 °F 74.2 0- . 5 Seal abandoned baseboard penetration. There was significant air leakage at this point. . Ensure that any packaging material is removed from window closing mechanisms .1"' i 1 ` which will reduce air tightness when 1 shutting. • Page 3 of 4 12/27/2017 P.O. Box 1434,Edwards,CO 81632 1 P: 970.306.4237 1 P: 970.446.4984 NORTPENFRGY ACTIVE ENERGIES... Congratulations on a passing the testing requirements. Please call with any questions or concerns. \I*°°4\ Jason Weingast LEED for Homes Green Rater,HERS Rater NORTH 39 MGT/Active Energies, Inc. Expert Energy Consulting, Training &Verification Services Page 4 of 4 12/27/2017 P.O. Box 1434,Edwards,CO 81632 P: 970.306.4237 P: 970.446.4984