HomeMy WebLinkAboutB17-0068_A2-01-03_1498501138.pdfBOILER
REF. DW
BOILER
BOILER
BOILER
REF.
REF.
REF.
DW
DW
DW
DW
W/D
03-A 03-B 03-C 03-D
03-1
03-2
03-3
03-4
03-E
A4.01-03/ 2
A4.01-03/ 4 A4.01-03/ 1
A4.01-03/ 3 UNIT TYPE 2.1B UNIT TYPE 3.2B UNIT TYPE 2.2B UNIT TYPE 3.2B
26' - 2 1/2" 26' - 4" 26' - 4" 26' - 2 1/2"
4' - 0" 22' - 11" 4' - 0" 30' - 11" 105' - 1"
1
A5.01-03
2
A5.01-03
1
A5.02-03
2
A5.02-03
12' - 4" 13' - 8" 12' - 4"
MODULAR BOX DIMENSION STRING
13' - 8"
12' - 4" 13' - 8" 12' - 4" 13' - 8"
18' - 0" 1 5/8" 18' - 0" 1' - 0"8" 14' - 6 1/2" 8"1' - 0" 1 5/8" 18' - 0"
TO FACE OF SHEATHING
2" 2" 2" 2" 2" 2" 2" 6' - 4" E002
1" / 12" 1" / 12"
E014
009
012
009
012
009
E022
012
009
012
E002
E014
E015 E015
013
006
005
1' - 0" MODULAR BOX DIM
28' - 0"
MODULAR BOX DIM
29' - 0"
TO FACE OF SHEATHING
TO FACE OF SHEATHING
MODULAR BOX DIM
28' - 0"
MODULAR BOX DIM
29' - 0"
MODULAR BOX DIM
28' - 0"
MODULAR BOX DIM
29' - 0"
MODULAR BOX DIM
28' - 0"
MODULAR BOX DIM
29' - 0"
TO FACE OF SHEATHING
TO FACE OF SHEATHING
TO FACE OF SHEATHING
TO FACE OF SHEATHING
TO FACE OF SHEATHING
TO FACE OF SHEATHING
03-A 03-B 03-C 03-D
03-1
03-2
03-3
03-4
03-E
A4.01-03/ 2
A4.01-03/ 4
A4.01-03/ 1
A4.01-03/ 3
UNIT TYPE 2.1B UNIT TYPE 3.2B UNIT TYPE 2.2B UNIT TYPE 3.2B
26' - 2 1/2" 26' - 4" 26' - 4" 26' - 2 1/2"
4' - 0"
22' - 11" 4' - 0" 30' - 11"
105' - 1"
1
A5.01-03
2
A5.01-03
1
A5.02-03
2
A5.02-03
9
A9.05
7
A9.05
8
A9.05
2
A9.05
1
A9.05
5
A9.05
6
A9.05
3
A9.05
6
A9.05
SLOPE 3"
SLOPE 3"
SLOPE 3"
SLOPE 3"
7" 3' - 10"
5' - 10" 8 1/2" 5' - 4"
8" 5' - 4"
8" 5' - 10" 9" 8 1/2" 5' - 4"
8" 5' - 10" 7" 6' - 0" 8 7/8"
5' - 4"
8" 3' - 3" 2' - 2 1/2"
2' - 6" E014
009
009
010
009
E014
009
E022
E015 E015
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O.
2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF
STRUCTURE U.N.O.
3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET
4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O.
5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING,
U.N.O.
6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS
BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT.
7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR
DRAWINGS
8. FURNITURE IS SHOWN FOR REFERENCE ONLY
9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE
FLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT
LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL
10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND
FOR DESIGNATIONS OF EXTERIOR MATERIALS.
11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL
SECTIONS
12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW
INFORMATION, SCHEDULES AND DETAILS
13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR
FINISH INFORMATION AND SCHEDULES
14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE
DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY
LOCATED COMMON AREA PER LOCAL CODE
15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD
INSTALLATIONS THAT OCCUR AT SLAB ON GRADE
CONDITIONS
16. ALL EXPOSED CONCRETE FOUNDATION WALLS,
CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR
ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC
17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS
18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O.
19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL
FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING
20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE
THERE IS A GRADE CHANGE OF 30" OR MORE
1
2
3
4
5
6 7
8
9
10
KEY PLAN
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
NOTE:
GRAY HATCH INDICATES SYSTEMS
BUILT SCOPE, TYP.
6/1/2017
2:14:43 PM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
A2.01-03
BUILDING 03 - FLOOR
PLANS
14054.1
CHAMONIX - VAIL
TOWN OF VAIL PERMIT
SET
MAY 31, 2017
3/16" = 1'-0"
2 BUILDING 03 - LEVEL 02
3/16" = 1'-0"
1 BUILDING 03 - LEVEL 01
KEYNOTE LEGEND - BUILDING
KEY NOTE
005 STAINED DOUGLAS FUR COLUMNS, RE: SPEC & STRUCT.
006 ELECTRICAL PANEL. RE: SYSTEMS BUILT MFR.
009 CONCRETE PATIO, TYP. RE: CIVIL.
010 GAS AND ELECTRIC METER LOCATION, INSTALLED BY
OTHERS.
012 STAINED WOOD STEPS, RE: SPEC.
013 GAS FIREPLACE, RE: SPEC
E002 RS-2 STANDING SEAM ROOF, LIGHT GREY; SEE A0-0 FOR
STANDARD ROOF ASSEMBLIES
E014 EXTERIOR STAINED DOUGLAS FUR TRELLIS AND
COLUMNS - OXFORD BROWN, SOLID STAIN; RE: SPEC &
STRUCT
E015 EXTERIOR STAINED DOUGLAS FUR TRELLIS AND
COLUMNS - MED CEDAR; RE: SPEC & STRUCT
E022 PRE-MANUFACTURED WINDOW WELL; RE: SPEC
No. Description Date
06/26/17