HomeMy WebLinkAboutB17-0068_A9-02_1508791947.pdfCONTINUOUS 2X8 FASCIA TRIM
ICE AND WATER SHIELD, LAP DN
OVER FASCIA
CONTINUOUS 2X FASCIA
CONTINUOUS SUB-FASCIA, RE: STRUCT.
ROOF TRUSS, RE: STRUCT.
HORIZ. STAINED CEDAR SHIP
LAP SIDING, RE: SPEC
7/16" EXTERIOR OSB SHEATHING,
RE: STRUCT.
VENTED
ROOF
2' - 0"
GIRDER TRUSS, RE: STRUCT.
RAINSCREEN SYSTEM LAP DN
OVER DRIP FLASHING, RE: SPEC.
PREMIUM ASHPHALT SHINGLES OVER ICE
AND WATER SHIELD OVER ENTIRE ROOF
OVER OSB SHEATHING, RE: STRUCT.
WRAP ICE AND WATER SHIELD OVER
HEADWALL VENT BLOCKING
DRIP FLASHING OVER PRE-
FINISHED METAL FLASHING
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
PRE-FINISHDED METAL FLASHING
TRUSSED ROOF, RE: STRUCT.
PERFORATED CEMENT BOARD SOFFIT
OVER ATTACHED TO BOTTOM OF
TRUSS, RE: SPEC AND ROOF PLAN
3"
MODULAR BOX MATE WALL
AIR SPACE, RE: PLAN.11 1/4"FULL HEIGHT BLOCKING
BETWEEN TRUSSES, RE:
STRUCT.MIN.2"2" MIN.EXTEND ICE & WATER SHIELD MIN. 1'-0" UP
WALL AND DN OVER HEADWALL VENT
DCI SMARTVENT HEADWALL APPLICATION.
INSTALL OVER FLASHING AND BLOCKING
AND LAYER OF SHINGLES OVER VENT
PRE-FINISHED FLASHING OVER BLOCKING.
3
DCI SMART RIDGE I RIDGE VENT
ASPHALT SHINGLE RIDGE VENT
PREMIUM ASPHALT SHINGLES
BASIS OF DESIGN IS CERTAINTEED
LANDMARK SOLARIS PLATINUM
SHEATHING OVER HIGH-HEEL
TRUSS RE: STRUCTURAL
LAP ICE AND WATER SHIELD INTO
OPENING
ICE AND WATER SHIELD INSTALLED
ON ENTIRE ROOF DECK
PER MFR.
HOLD BACK ROOF SHEATHING EACH
SIDE FULL LENGTH OF RIDGE VENT,
PER MFR. SPECIFICATIONS
EQ EQ
PERFORATED CEMENT BOARD SOFFIT
OVER ATTACHED TO BOTTOM OF
TRUSS, RE: SPEC AND ROOF PLAN
LAP ICE AND WATER SHIELD OVER
PRE-FINISHED MTL FLASHING
CONTINUOUS SUB-FASCIA,
RE: STRUCT.
CONTINUOUS 2X FASCIA
CONTINUOUS 2X8 FASCIA TRIM
ROOF TRUSS RE: STRUCT
VENTED
ROOF
TRUSSED ROOF, RE: STRUCT.
RAINSCREEN SYSTEM LAP DN
OVER DRIP FLASHING, RE: SPEC.
ROOF SHEATHING, RE: STRUCT.
DRIP FLASHING OVER SIDEWALL
STEP FLASHING
EXTEND ICE & WATER SHIELD MIN.
1'-0" UP WALL AND DN OVER
HEADWALL VENT
1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION OVER
7/16" EXT. SHEATHING, RE: SPEC.
HORZ. STAINED CEDAR SHIP
LAP SIDING, RE: SPEC
INSULATION BAFFLE, 2" MIN.
SPACE
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
(1) LAYER 5/8" GYP BD.
SPRAY FOAM INSULATION,
R-21 MIN.
RIGID INSULATION TO TOP OF
PERIMETER 2X PLATE
(2) 2X6 SILL PLATE
2X10 RIM JOISTHEEL HEIGHT1' - 0"11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER
STRIPPED IN ICE AND WATER SHIELD
5/8" GYP BD. OVER 7/16" OSB
SHEATHING
OSB COMPRESSION STRIPS
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE
AND 8" IN ATTIC SPACE
2' - 0"MIN
.2"FULL HEIGHT BLOCKING BETWEEN
TRUSSES, RE: STRUCT. 2" MIN.PREMIUM ASHPHALT SHINGLES OVER ICE
AND WATER SHIELD OVER ENTIRE ROOF
OVER OSB SHEATHING, RE: STRUCT.
WRAP ICE AND WATER SHIELD OVER
HEADWALL VENT BLOCKING
DCI SMARTVENT HEADWALL
APPLICATION. INSTALL OVER
FLASHING AND BLOCKING AND
LAYER OF SHINGLES OVER VENT
PRE-FINISHED FLASHING OVER BLOCKING.
GIRDER TRUSS, RE: STRUCT.
MODULAR BOX MATE WALL
AIR SPACE, RE: PLAN.
3
HORZ. SHIP LAP SIDING OVER
PRE-FINISHED MTL. FLASHING
OVER RAINSCREEN SYSTEM
HIGH TEMP ICE SHIELD
WATERPROOFING OVER
SHEATHING, LAP UP WALL
PER MFR. SPECS.
PRE-FINISHED STANDING SEAM
METAL ROOF LAP UP UNDER
FLASHING AND OVER SPLICE IN
MEMEBRANE FLASHING
LAP RAINSCREEN DN
OVER FLASHING
6X6 STAINED DF COLUMN BEYOND,
RE: STRUCT.
CEMENT BOARD SOFFIT
TIMBER SCREWS THROUGH 2X12
LEDGER BOARD TOP & BOTTOM
INTO BOX FRAMING @ 48" O.C., RE:
STRUCT.
GABLE ROOF FLASHING
OVER METAL CLEAT
CONT. 2X6 FASCIA TRIM
CONTINUOUS 2X FASCIA OVER
RE: PLAN
RE: PLAN
SEALANT, TYP.
STUCCO J BEAD CLOSER
WALL ASSEMBLY, RE: PLAN
WALL ASSEMBLY, RE: PLAN
LVL RAFTER, RE: STRUCT.
1"CEMENT BOARD SOFFIT OVER
RAINSCREEN SYSTEM
FLOOR SYSTEM, RE: SYSTEMS
BUILT MFR.
SPRAY FOAM, RE: SYSTEMS
BUILT MFR.
PACK OUT ENTIRE JOIST SPACE
WITH BATT INSULATION.
2" MIN.PERFORATED CEMENT BOARD SOFFIT
ATTACHED TO BOTTOM OF TRUSS, RE:
SPEC AND ROOF PLAN
LAP ICE AND WATER SHIELD OVER
PRE-FINISHED MTL FLASHING
CONTINUOUS SUB-FASCIA,
RE: STRUCT.
CONTINUOUS 2X FASCIA
CONTINUOUS 2X8 FASCIA TRIM
ROOF TRUSS RE: STRUCT
VENTED
ROOF
RAINSCREEN SYSTEM, RE: SPEC.
1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION OVER
7/16" EXT. SHEATHING, RE: SPEC.
INSULATION BAFFLE, 2" MIN.
SPACE
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
(1) LAYER 5/8" GYP BD.
SPRAY FOAM INSULATION,
R-21 MIN.
RIGID INSULATION TO TOP OF
PERIMETER 2X PLATE
(2) 2X6 SILL PLATE
2X10 RIM JOISTHEEL HEIGHT1' - 0"11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER
STRIPPED IN ICE AND WATER SHIELD
5/8" GYP BD. OVER 7/16" OSB
SHEATHING
OSB COMPRESSION STRIPS
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE
AND 8" IN ATTIC SPACE
2' - 0"MIN.2"FULL HEIGHT BLOCKING BETWEEN
TRUSSES, RE: STRUCT.
SEALANT, TYP.
STUCCO J BEAD CLOSER
2 COAT STUCCO SYSTEM OVER
GALVANIZED FURRED WIRE
MESH, RE: SPEC
LAP ICE AND WATER SHIELD
OVER COLLAR FLANGE
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD
OVER ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
STRIP IN MEMBRANE FLASHING,
EXTEND 4" MIN. BEYOND COLLAR
FLANGE
ATTACH VENT COLAR FLANGE
TO ROOF SHEATHING PER MFR.
REQUIREMENTS. PROVIDE
NECESSARY SUPPORTS UNDER
DECK AS REQUIRED.
CONT. SEALANT AROUND
VENT COLLAR
VENT COLLAR, RE:
MECH/PLUMBING
MECH/PLUMBING VENT
ROOF PENETRATION, RE:
MECH/PLUMBING
ROOF TRUSS, RE: STRUCT.
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
NOTE:
GRAY HATCH INDICATES SYSTEMS
BUILT SCOPE, TYP.
9/21/2017 4:26:21 PM C:\Users\rwilberger\Documents\CHAMONIX_Building
Models_rwilberger.rvt
A9.02
ROOF DETAILS
14054.1CHAMONIX - VAILTOWN OF VAIL PERMIT
SET
MAY 31, 2017
1 1/2" = 1'-0"2 TYP. SHED ROOF EAVE
1 1/2" = 1'-0"5 ROOF RIDGE VENT
1 1/2" = 1'-0" 3 TYP. UPPER ROOF EAVE OVER LOW ROOF
1 1/2" = 1'-0" 4 TYP. EYEBROW ROOF
No. Description Date
3 ASI 003 09-21-2017
1 1/2" = 1'-0"1 TYP. LOWER ROOF EAVE
1 1/2" = 1'-0" 6 TYP. ROOF PENETRATION
3
10/23/17