HomeMy WebLinkAboutB17-0068_A9-03_1498501146.pdfEACH SIDE OF DEMISING WALL TO BE
DISCONTINUOUS SO EITHER SIDE CAN FAIL
WITHOUT AFFECTING THE OTHER SIDE
2-HR UNIT DEMISING WALL; WALL TYPE
E1, RE: A0.01 FOR ALL STANDARD WALL
TYPES
1"x3" PT WOOD BLOCKING
RAINSCREEN SYSTEM, RE: SPEC.
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR.
1" R-5 MIN. FOIL FACED
POLYISO, RE: SPEC.
HORZ. STAINED CEDAR
SHIP LAP SIDING, RE: SPEC
MIN. R-20 UNFACED BATT INSULATION,
RE: SPEC.
MEMBRANE FLASHING, WRAP
CORNER MIN. 4"
PREFINISHED ALUMINUM J CLOSURE
1"x3" PT WOOD BLOCKING
RAINSCREEN SYSTEM,
RE: SPEC.
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR.
1" R-5 MIN. FOIL FACED
POLYISO, RE: SPEC.
MIN. R-20 UNFACED BATT
INSULATION, RE: SPEC.
MEMBRANE FLASHING, WRAP
CORNER MIN. 4"
2 COAT STUCCO SYSTEM
OVER GALVANIZED METAL
LATH, RE: SPEC
1"x3" PT WOOD BLOCKING
RAINSCREEN SYSTEM,
RE: SPEC.
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR.
1" R-5 MIN. FOIL FACED
POLYISO, RE: SPEC.
11/16" HORZ. STAINED CEDAR
SHIP LAP SIDING, RE: SPEC
MIN. R-20 UNFACED BATT
INSULATION, RE: SPEC.
MEMBRANE FLASHING, WRAP
CORNER MIN. 4"
5/4"x4" WOOD TRIM, RE: SPEC
2 COAT STUCCO SYSTEM OVER
GALVANIZED METAL LATH, RE: SPEC
EACH SIDE OF DEMISING WALL TO
BE DISCONTINUOUS SO EITHER
SIDE CAN FAIL WITHOUT
AFFECTING THE OTHER SIDE
DEMISING WALL; WALL TYPE E1
RE: A0-01 FOR ALL STANDARD
WALL TYPES
RAINSCREEN SYSTEM, RE: SPEC
MEMBRANE FLASHING, WRAP
CORNER MIN. 4"
1"x3" PT WOOD BLOCKING
1" R-5 MIN FOIL FACED POLYISO,
RE: SPEC
MIN. R-20 UNFACED BATT
INSULATION, RE: SPEC
7/16" EXTERIOR OSB SHEATHER,
RE: SYSTEMS BUILT MFR
NOTE: DETAILS DO NOT REFLECT ALL
EXTERIOR CLADDING CONDITIONS -
SEE PLANS AND ELEVATIONS FOR
BUILDING MATERIALS
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR.
2-HR DEMISING WALL; WALL
TYPE E1, RE: A-0.01 FOR ALL
STANDARD WALL TYPES
EACH SIDE OF DEMISING WALL
TO BE DISCONTINUOUS SO
EITHER SIDE CAN FAIL WITHOUT
AFFECTING THE OTHER SIDE
2 COAT STUCCO SYSTEM OVER
GALVANIZED METAL LATH, RE:
SPEC
MIN. R-20 UNFACED BATT
INSULATION. RE: SPEC.
1" R-5 MIN. FOIL FACED POLYISO,
RE: SPEC
RAINSCREEN SYSTEM, RE: SPEC
EACH SIDE OF DEMISING WALL TO BE
DISCONTINUOUS SO EITHER SIDE CAN FAIL
WITHOUT AFFECTING THE OTHER SIDE
2-HR UNIT DEMISING WALL; WALL TYPE
E1, RE: A0.01 FOR ALL STANDARD WALL
TYPES
1"x3" PT WOOD BLOCKING
RAINSCREEN SYSTEM, RE: SPEC.
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR.
2 COAT STUCCO SYSTEM OVER
GALVANIZED METAL LATH, RE: SPEC
1" R-5 MIN. FOIL FACED
POLYISO, RE: SPEC.
HORZ. STAINED CEDAR
SHIP LAP SIDING, RE: SPEC
MIN. R-20 UNFACED BATT INSULATION,
RE: SPEC.
STUCCO J BEAD CLOSER
MEMBRANE FLASHING, WRAP
CORNER MIN. 4"
PREFINISHED ALUMINUM J CLOSURE
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
6/1/2017
2:15:48 PM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
A9.03
PLAN DETAILS
14054.1
CHAMONIX - VAIL
TOWN OF VAIL PERMIT
SET
MAY 31, 2017
1 1/2" = 1'-0"
2 TYP. INSIDE CORNER @ WOOD SIDING
3"
= 1'-0"
5 TYP. STUCCO SIDING OUTSIDE CORNER
3" = 1'-0" 6 TYP. WOOD SIDING OUTSIDE CORNER
1 1/2" = 1'-0"1 TYP. DETAIL INSIDE CORNER @ STUCCO
1 1/2" = 1'-0"
4 TYP. DETAL @ DEMISING WALL INTERSECTION
1 1/2" = 1'-0" 3 TYP. INSIDE CORNER @ WOOD SIDING & STUCCO
No. Description Date
06/26/17