HomeMy WebLinkAboutB17-0068_A9-04_1498501146.pdf(2) 2X6 SILL PLATE
2X6 SILL PLATE
1" X 4" BASE TRIM, RE: FINISH SCHEDULE
5/8" TYPE X GYP. BD OVER 7/16"
OSB SHEATHING RE: SYSTEMS
BUILT MFR
3" AIR GAP
5/8" TYPE X GYP BD OVER 7/16"
OSB, RE: SPEC.
(2) 2X12 RIM JOISTS
SPRAY FOAM INSULATION R-21 MIN.
7/8" T&G PLYWOOD SHEATHING
RE: SYSTEMS BUILT MFR
FINISH FLOOR, RE: FINISH SCHEDULE
5/8" TYPE X GYP BD
7/16" FIRE RATED OSB SHEATHING,
RE: SYSTEMS BUILT MFR
2 1/8"
BATT INSULATION FOR FIREBLOCK
BETWEEN MODULES
1-HR COMMON WALL
3"
2-HR WALL 1-HR WALL
5/8" TYPE X GYP. BD OVER 7/16"
FIRE RATED OSB SHEATHING, RE:
SYSTEMS BUILT MFR
2 1/8" AIR GAP
(2) 2X6 SILL PLATE
5/8" GYP BD. OVER 7/16" OSB SHEATHING
(2) 2X12 RIM JOISTS
SPRAY FOAM INSULATION, R-21 MIN.
(2) 2X10 RIM JOIST
2X4 SILL PLATE
SPRAY FOAM INSULATION, R-21 MIN.
R-11 BLANKET INSULATION W/ NET REST
FOR FIRE BLOCKING BETWEEN JOISTS
7/16" OSB SHEATHING, RE;
SYSTEMS BUILT MFR
1"x4" BASE TRIM, RE: FINISH SCHEDULE
FINISH FLOOR, RE: FINISH SCHEDULE
7/8" T&G PLYWOOD SHEATHING,
RE: SYSTEMS BUILT MFR.
2X6 SILL PLATE
(2) LAYERS EXT. TYPE X GYP. BD.
5/8" TYPE X GYP BD. OVER 7/16" FIRE
RATED (2 SIDED) OSB SHEATING, RE:
SYSTEMS BUILT MFR.
7/16" OSB SHEATHING, RE;
SYSTEMS BUILT MFR
2X4 PERIMETER BLOCKING FOR
TRUSS BEARING
TRUSS W/ CONTINUOUS 7/16" FIRE
RATED SHEATHING AIR SPACE SIDE AND
5/8" GYP. BD. ATTIC SIDE. ALL JOINTS TO
BE TAPED AND ALL PENETRATIONS TO
BE FULLY FIRE CAULKED
TRUSSED ROOF, RE: STRUCT.
VENTED
ROOF
1 3/8"
2 1/8"
BATT INSULATION FOR FIREBLOCK
BETWEEN MODULES
7/16" OSB STRIPS FLOOR AND
CEILING, RE: SYSTEMS BUILT MFR
2-HR COMMON WALL
OSB COMPRESSION STRIPS
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE AND
8" IN ATTIC SPACE
5/8" TYPE X GYP. BD OVER 7/16"
OSB SHEATHING, RE: SYSTEMS
BUILT MFR
2 1/8" AIR GAP
(2) 2X6 SILL PLATE
5/8" TYPE X GYP BD. OVER 7/16"
OSB SHEATHING
(2) 2X12 RIM JOISTS
SPRAY FOAM INSULATION, R-21 MIN.
(2) 2X10 RIM JOIST
2X BEARING PLATE - SITE INSTALLED
SPRAY FOAM INSULATION, R-21 MIN.
R-11 BLANKET INSULATION W/ NET REST
FOR FIRE BLOCKING BETWEEN JOISTS
7/16" OSB SHEATHING, RE;
SYSTEMS BUILT MFR
1"x4" BASE TRIM, RE: FINISH SCHEDULE
FINISH FLOOR, RE: FINISH SCHEDULE
7/8" T&G PLYWOOD SHEATHING,
RE: SYSTEMS BUILT MFR.
2X6 SILL PLATE
2 1/8"
5/8" TYPE X GYP. BD OVER 7/16"
OSB SHEATHING, RE: SYSTEMS
BUILT MFR
BATT INSULATION FOR FIREBLOCK
BETWEEN MODULES
1-HR COMMON WALL
7/16" OSB STRIPS FLOOR AND
CEILING, RE: SYSTEMS BUILT MFR
OSB COMPRESSION STRIPS
2 1/8"
5/8" TYPE X GYP BD. OVER 7/16"
OSB SHEATHING, RE: SYSTEMS
BUILT MFR.
2 1/8" AIR GAP
(2) 2X6 SILL PLATE
(2) 2X10 RIM JOIST
7/16" OSB SHEATHING, RE;
SYSTEMS BUILT MFR
2X4 PERIMETER BLOCKING FOR
TRUSS BEARING
GIRDER TRUSS W/ CONTINUOUS
7/16" FIRE RATED SHEATHING AIR
SPACE SIDE AND 5/8" TYPE X GYP.
BD. ATTIC SIDE. ALL JOINTS TO BE
TAPED AND ALL PENETRATIONS TO
BE FULLY FIRE CAULKED
TRUSSED ROOF, RE: STRUCT.
7/16" FIRE RATED SHEATHING AND
5/8" GYP. BD. HELD TIGHT TO BOTTOM
OF ROOF SHEATHING, FULLY FIRE
CAULK ALL JOINTS
PREMIUM ASHPHALT SHINGLES OVER
ICE AND WATER SHIELD OVER ENTIRE
ROOF OVER ROOF SHEATHING, RE:
STRUCT.
2 1/8"
BATT INSULATION FOR FIREBLOCK
BETWEEN MODULES
PROPERTY
LINE
4'-0" FRT
SHEATHING
4'-0" FRT
SHEATHING
1-HR RATED ROOF SHEATHING 4'-0"
EITHER SIDE OF PROPERTY LINE
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE AND
8" IN ATTIC SPACE
VENTED
ROOF
7/16" OSB STRIPS FLOOR AND
CEILING, RE: SYSTEMS BUILT MFR
OSB COMPRESSION STRIPS
VENTED
ROOF
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
1 HR RATED SOFFIT: CEMENT BOARD
SOFFIT OVER 7/16" FIRE RATED SHEATHING
ATTACHED TO BOTTOM OF TRUSS
LAP ICE AND WATER SHIELD OVER
PREFINISHED MTL FLASHING
CONTINUOUS SUB-FASCIA,
RE: STRUCT
CONTINUOUS 2X FASCIA
CONTINUOUS 2X10 FASCIA TRIM
ROOF TRUSS RE: STRUCT
2' - 0"
PROPERTY
LINE
4'-0" FRT
SHEATHING
FRT SHEATHING
VENTED
ROOF
TRUSS W/ CONTINUOUS 7/16" FIRE
RATED SHEATHING AIR SPACE SIDE AND
5/8" GYP. BD. ATTIC SIDE. ALL JOINTS TO
BE TAPED AND ALL PENETRATIONS TO
BE FULLY FIRE CAULKED
TRUSSED ROOF, RE: STRUCT.
RAINSCREEN SYSTEM LAP DN
OVER DRIP FLASHING, RE: SPEC.
MIN.
2"
PREMIUM ASHPHALT SHINGLES OVER
ICE AND WATER SHIELD OVER ENTIRE
ROOF OVER OSB SHEATHING, RE:
STRUCT.
1-HR RATED ROOF SHEATHING
4'-0" OF PROPERTY LINE
DRIP FLASHING OVER SIDEWALL
STEP FLASHING
EXTEND ICE & WATER SHIELD MIN.
1'-0" UP WALL
1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION OVER
(2) LAYERS 5/8" EXT. GYP BD
OVER, RE: SYSTEMS BUILT MFR.
HORZ. STAINED CEDAR SHIP
LAP SIDING, RE: SPEC
PREFINISHED METAL FLASHING
FULLY BLOCK BETWEEN TRUSSES
(2) LAYERS, BLOCKING AND EXT.
GYP. BD. HELD TIGHT TO BOTTOM
OF ROOF SHEATHING, FULLY FIRE
CAULK ALL JOINTS
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT
SPRAY FOAM INSULATION, R-21 MIN.
RIGID INSULATION HELD TIGHT TO
BOTTOM OF ROOF SHEATHING
(2) 2X6 SILL PLATE
5/8" GYP BD. OVER 7/16" OSB SHEATHING
(2) 2X10 RIM JOIST 11 1/4"
2-HR WALL
1-HR WALL
(2) LAYERS EXT. TYPE X GYP. BD.
5/8" TYPE X GYP BD. OVER 7/16" FIRE
RATED (2 SIDED) OSB SHEATING, RE:
SYSTEMS BUILT MFR.
OSB COMPRESSION STRIPS
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE AND
8" IN ATTIC SPACE
HEEL HEIGHT
1' - 0"
(2) 2X6 SILL PLATE
2X6 SILL PLATE
1" X 4" BASE TRIM, RE: FINISH SCHEDULE
5/8" TYPE X GYP. BD OVER 7/16" FIRE
RATED OSB SHEATHING RE:
SYSTEMS BUILT MFR
3" AIR GAP
(2) 2X12 RIM JOISTS
SPRAY FOAM INSULATION R-21 MIN.
7/8" T&G PLYWOOD SHEATHING
RE: SYSTEMS BUILT MFR
FINISH FLOOR, RE: FINISH SCHEDULE
5/8" GYP BD
5/8" TYPE X GYP. BD. OVER 7/16"
FIRE RATED OSB SHEATHING, RE:
SYSTEMS BUILT MFR
2 1/8"
BATT INSULATION FOR FIREBLOCK
BETWEEN MODULES
2-HR COMMON WALL
7/16" OSB STRIPS, RE: SYSTEMS
BUILT MFR
CEMENT BOARD SOFFIT OVER
ATTACHED TO BOTTOM OF
TRUSS, RE: SPEC
LAP ICE AND WATER SHIELD OVER
PRE-FINISHED MTL FLASHING
CONTINUOUS SUB-FASCIA,
RE: STRUCT.
CONTINUOUS 2X FASCIA
CONTINUOUS 2X8 FASCIA TRIM
DROPPED CORD TRUSS RE: STRUCT
VENTED
ROOF
RAINSCREEN SYSTEM, RE: SPEC.
1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION OVER
7/16" EXT. SHEATHING, RE: SPEC.
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
(1) LAYER 5/8" GYP BD.
SPRAY FOAM INSULATION,
R-21 MIN.
RIGID INSULATION TO BOTTOM OF
LOOKOUT RAFTER
(2) 2X6 SILL PLATE
2X10 RIM JOIST
PRE-FINISHED MTL DRIP FLASHING OVER
STRIPPED IN ICE AND WATER SHIELD
5/8" GYP BD. OVER 7/16" OSB
SHEATHING
OSB COMPRESSION STRIPS
2' - 0"
SEALANT, TYP.
STUCCO J BEAD CLOSER
2 COAT STUCCO SYSTEM OVER
GALVANIZED FURRED WIRE
MESH, RE: SPEC
2 X12 LOOKOUT RAFTER RE: STRUCT
MIN.
2"
2X BLOCKING BETWEEN
TRUSSES, RE: STRUCT.
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE
AND 8" IN ATTIC SPACE
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
NOTE:
GRAY HATCH INDICATES SYSTEMS
BUILT SCOPE, TYP.
6/1/2017
2:15:51 PM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
A9.04
DEMISING WALL
DETAILS
14054.1
CHAMONIX - VAIL
TOWN OF VAIL PERMIT
SET
MAY 31, 2017
1 1/2" = 1'-0"
3 1-HR DEMISING WALL @ LEVEL 2
1 1/2" = 1'-0" 5 2-HR DEMISING WALL @ LEVEL 3
1 1/2" = 1'-0" 2 1-HR DEMISING WALL @ FLOOR LEVEL 3
1 1/2" = 1'-0"
1 1-HR DEMISING WALL @ ROOF
1 1/2" = 1'-0"4 2-HR DEMISING WALL @ LOWER/UPPER ROOF
1 1/2" = 1'-0" 6 2-HR DEMISING WALL @ LEVEL 2
No. Description Date
1 1/2" = 1'-0"7 TYP. GABLE END EAVE
06/26/17