HomeMy WebLinkAboutB17-0068_G0-01-03_1495580626.pdfPARTITION LEGEND
1 HR BARRIER
2 HR BARRIER
(1 HR EA. SIDE)
REFERENCE A0.01 FOR WALL TYPES
1 HR BARRIER ONE SIDE
2 HR BARRIER ONE SIDE
5/8" TYPE "X" GYP. BD.
1 HR RATING THIS
SECTION OF WALL
NOTE: ALL GARAGE CEILINGS
ARE REQUIRED TO HAVE 5/8"
TYPE 'X' GYPSUM BOARD
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
HATCHED AREA INDICATES 4'-0" OFF
OF DEMISING WALL CENTERLINE.
F.R.P. SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA
LEVEL 1
100' - 0"
LEVEL 2
111' - 0"
03-A 03-B 03-C 03-D 03-E
LEVEL 3
122' - 0"
LEVEL 4
133' - 0"
2 CAR GARAGE
LIVING BEDROOM
LIVING
CLOSET
MASTER
BEDROOM
MASTER
BEDROOM
TOILET
2 CAR GARAGE 2 CAR GARAGE
1 CAR GARAGE ENTRY BATH
BEDROOM
LIVING
TOILET MASTER
BATH
MASTER
BEDROOM
MASTER BATH
LIVING
MECH
CLOSET
BEDROOM 11' - 0"
11' - 0" 11' - 0" 9" 1' - 0" 1 HR HORIZONTAL RATING 4'-0" EITHER
SIDE OF DEMISING WALL CENTERLINE.
F.R.P. SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA
1 HR RATED SOFFIT
1 HR HORIZONTAL
RATING 4'-0"
1 HR RATING TO
UNDERSIDE OF LOWER
ROOF
1 HR RATING TO
UNDERSIDE OF UPPER
ROOF
1 HR VERTICAL RATING BETWEEN GARAGE
AND FINISHED SPACE AND 1HR HORIZONAL
RATING AT GARAGE CEILING TO FINISHED
SPACE ABOVE
TYPICAL 2 HR VERTICAL UNIT
DEMISING WALL RATING
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
FOR REFERENCE
ONLY
4/26/2017
11:37:12 AM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
G0.01-03
CODE STUDY
14054.1
CHAMONIX - VAIL
FOUNDATION PERMIT
APRIL 26, 2017
1/16" = 1'-0"
1 LEVEL 01
1/16" = 1'-0"
2 LEVEL 02
1/16" = 1'-0"
3 LEVEL 03
1/16" = 1'-0"
4 ROOF
1/8" = 1'-0"
5 CODE SECTION 1-3
No. Description Date
1
1
1 FOUNDATION PERMIT COMMENTS 05/17/17