HomeMy WebLinkAboutB17-0068_G0-01-03_1498501154.pdfPARTITION LEGEND
1 HR BARRIER
(RATED 1HR FROM
EACH SIDE)
2 HR BARRIER
(RATED 2HR FROM
EACH SIDE)
REFERENCE A0.01 FOR WALL TYPES
5/8" TYPE "X" GYP. BD.
1 HR RATING THIS
SECTION OF WALL
NOTE: ALL GARAGE CEILINGS
ARE REQUIRED TO HAVE 5/8"
TYPE 'X' GYPSUM BOARD
1 HR RATING WITH
SPRINKLER REDUCTION
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING WITH
SPRINKLER REDUCTION
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING WITH
SPRINKLER REDUCTION
HATCHED AREA INDICATES 4'-0" OFF
OF DEMISING WALL CENTERLINE.
FRT SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA
LEVEL 1
100' - 0"
LEVEL 2
111' - 0"
03-A 03-B 03-C 03-D 03-E
LEVEL 3
122' - 0"
LEVEL 4
133' - 0"
2 CAR GARAGE
LIVING BEDROOM
LIVING
CLOSET
MASTER
BEDROOM
MASTER
BEDROOM
TOILET
2 CAR GARAGE 2 CAR GARAGE
1 CAR GARAGE ENTRY BATH
BEDROOM
LIVING
TOILET MASTER
BATH
MASTER
BEDROOM
MASTER BATH
LIVING
MECH
CLOSET
BEDROOM 11' - 0"
11' - 0" 11' - 0" 9" 1' - 0" 1 HR HORIZONTAL RATING 4'-0"
EITHER SIDE OF DEMISING WALL
CENTERLINE. FRT SHEATHING
REQUIRED IN ROOF ASSEMBLY FOR
THIS AREA
1 HR RATED SOFFIT
1 HR HORIZONTAL
RATING 4'-0"
1 HR RATING TO
UNDERSIDE OF LOWER
ROOF
1 HR RATING TO
UNDERSIDE OF UPPER
ROOF
TYPICAL 1 HR VERTICAL UNIT
DEMISING WALL RATING WITH
SPRINKLER REDUCTION
5/8" TYPE "X" GYP BD AT ALL GARAGE
WALLS AND CEILINGS ADJACENT TO OR
UNDER FINISHED SPACE AND AT
STRUCTRUAL STEEL BEAM SOFFITS.
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
6/1/2017
2:16:01 PM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
G0.01-03
CODE STUDY
14054.1
CHAMONIX - VAIL
TOWN OF VAIL PERMIT
SET
MAY 31, 2017
1/16" = 1'-0"
1 LEVEL 01
1/16" = 1'-0"
2 LEVEL 02
1/16" = 1'-0"
3 LEVEL 03
1/16" = 1'-0"
4 ROOF
1/8" = 1'-0" 5 CODE SECTION 1-3
No. Description Date
06/26/17