Loading...
HomeMy WebLinkAboutB17-0069_A9-02_1498508400.pdfCONTINUOUS 2X8 FASCIA TRIM ICE AND WATER SHIELD, LAP DN OVER FASCIA CONTINUOUS 2X FASCIA CONTINUOUS SUB-FASCIA, RE: STRUCT. ROOF TRUSS, RE: STRUCT. HORIZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC 7/16" EXTERIOR OSB SHEATHING, RE: STRUCT. VENTED ROOF 2' - 0" GIRDER TRUSS, RE: STRUCT. RAINSCREEN SYSTEM LAP DN OVER DRIP FLASHING, RE: SPEC. PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER OSB SHEATHING, RE: STRUCT. DRIP FLASHING OVER PRE- FINISHED METAL FLASHING PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. PRE-FINISHDED METAL FLASHING TRUSSED ROOF, RE: STRUCT. PERFORATED CEMENT BOARD SOFFIT OVER ATTACHED TO BOTTOM OF TRUSS, RE: SPEC AND ROOF PLAN 3" MODULAR BOX MATE WALL AIR SPACE, RE: PLAN. 11 1/4" FULL HEIGHT BLOCKING BETWEEN TRUSSES, RE: STRUCT. MIN. 2" 2" MIN. EXTEND ICE & WATER SHIELD MIN. 1'-0" UP WALL AND DN OVER HEADWALL VENT DCI SMARTVENT HEADWALL APPLICATION. INSTALL OVER SHINGLES AND LAYER OF SHINGLES OVER VENT DCI SMART RIDGE I RIDGE VENT ASPHALT SHINGLE RIDGE VENT PREMIUM ASPHALT SHINGLES BASIS OF DESIGN IS CERTAINTEED LANDMARK SOLARIS PLATINUM SHEATHING OVER HIGH-HEEL TRUSS RE: STRUCTURAL LAP ICE AND WATER SHIELD INTO OPENING ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF DECK PER MFR. HOLD BACK ROOF SHEATHING EACH SIDE FULL LENGTH OF RIDGE VENT, PER MFR. SPECIFICATIONS EQ EQ PERFORATED CEMENT BOARD SOFFIT OVER ATTACHED TO BOTTOM OF TRUSS, RE: SPEC AND ROOF PLAN LAP ICE AND WATER SHIELD OVER PRE-FINISHED MTL FLASHING CONTINUOUS SUB-FASCIA, RE: STRUCT. CONTINUOUS 2X FASCIA CONTINUOUS 2X8 FASCIA TRIM ROOF TRUSS RE: STRUCT VENTED ROOF TRUSS W/ CONTINUOUS 7/16" FIRE RATED SHEATHING AIR SPACE SIDE AND 5/8" GYP. BD. ATTIC SIDE. ALL JOINTS TO BE TAPED AND ALL PENETRATIONS TO BE FULLY FIRE CAULKED TRUSSED ROOF, RE: STRUCT. RAINSCREEN SYSTEM LAP DN OVER DRIP FLASHING, RE: SPEC. PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER OSB SHEATHING, RE: STRUCT. ROOF SHEATHING, RE: STRUCT. DRIP FLASHING OVER SIDEWALL STEP FLASHING EXTEND ICE & WATER SHIELD MIN. 1'-0" UP WALL AND DN OVER HEADWALL VENT 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION OVER 7/16" EXT. SHEATHING, RE: SPEC. HORZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC DCI SMARTVENT HEADWALL APPLICATION. INSTALL OVER SHINGLES AND LAYER OF SHINGLES OVER VENT INSULATION BAFFLE, 2" MIN. SPACE PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. (1) LAYER 5/8" GYP BD. SPRAY FOAM INSULATION, R-21 MIN. RIGID INSULATION TO TOP OF PERIMETER 2X PLATE (2) 2X6 SILL PLATE 2X10 RIM JOIST HEEL HEIGHT 1' - 0" 11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER STRIPPED IN ICE AND WATER SHIELD 5/8" GYP BD. OVER 7/16" OSB SHEATHING OSB COMPRESSION STRIPS EPDM MEMBRANE, RE; SYSTEMS BUILT MFR R-49 BATT INSULATION - 8" IN MODULAR CEILING STRUCTURE AND 8" IN ATTIC SPACE 2" MIN. 2' - 0" MIN. 2" FULL HEIGHT BLOCKING BETWEEN TRUSSES, RE: STRUCT. HORZ. SHIP LAP SIDING OVER PRE-FINISHED MTL. FLASHING OVER RAINSCREEN SYSTEM HIGH TEMP ICE SHIELD WATERPROOFING OVER SHEATHING, LAP UP WALL PER MFR. SPECS. PRE-FINISHED STANDING SEAM METAL ROOF LAP UP UNDER FLASHING AND OVER SPLICE IN MEMEBRANE FLASHING LAP RAINSCREEN DN OVER FLASHING 6X6 STAINED DF COLUMN BEYOND, RE: STRUCT. CEMENT BOARD SOFFIT TIMBER SCREWS THROUGH 2X12 LEDGER BOARD TOP & BOTTOM INTO BOX FRAMING @ 48" O.C., RE: STRUCT. GABLE ROOF FLASHING OVER METAL CLEAT CONT. 2X6 FASCIA TRIM CONTINUOUS 2X FASCIA OVER RE: PLAN RE: PLAN SEALANT, TYP. STUCCO J BEAD CLOSER WALL ASSEMBLY, RE: PLAN WALL ASSEMBLY, RE: PLAN LVL RAFTER, RE: STRUCT. 1" CEMENT BOARD SOFFIT OVER RAINSCREEN SYSTEM FLOOR SYSTEM, RE: SYSTEMS BUILT MFR. SPRAY FOAM, RE: SYSTEMS BUILT MFR. PACK OUT ENTIRE JOIST SPACE WITH BATT INSULATION. 2" MIN. PERFORATED CEMENT BOARD SOFFIT OVER ATTACHED TO BOTTOM OF TRUSS, RE: SPEC AND ROOF PLAN LAP ICE AND WATER SHIELD OVER PRE-FINISHED MTL FLASHING CONTINUOUS SUB-FASCIA, RE: STRUCT. CONTINUOUS 2X FASCIA CONTINUOUS 2X8 FASCIA TRIM ROOF TRUSS RE: STRUCT VENTED ROOF RAINSCREEN SYSTEM, RE: SPEC. 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION OVER 7/16" EXT. SHEATHING, RE: SPEC. INSULATION BAFFLE, 2" MIN. SPACE PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. (1) LAYER 5/8" GYP BD. SPRAY FOAM INSULATION, R-21 MIN. RIGID INSULATION TO TOP OF PERIMETER 2X PLATE (2) 2X6 SILL PLATE 2X10 RIM JOIST HEEL HEIGHT 1' - 0" 11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER STRIPPED IN ICE AND WATER SHIELD 5/8" GYP BD. OVER 7/16" OSB SHEATHING OSB COMPRESSION STRIPS EPDM MEMBRANE, RE; SYSTEMS BUILT MFR R-49 BATT INSULATION - 8" IN MODULAR CEILING STRUCTURE AND 8" IN ATTIC SPACE 2' - 0" MIN. 2"FULL HEIGHT BLOCKING BETWEEN TRUSSES, RE: STRUCT. SEALANT, TYP. STUCCO J BEAD CLOSER 2 COAT STUCCO SYSTEM OVER GALVANIZED FURRED WIRE MESH, RE: SPEC PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP NOTE: GRAY HATCH INDICATES SYSTEMS BUILT SCOPE, TYP. 6/1/2017 2:19:53 PM C:\Users\lfrazier\Documents\CHAMONIX_Building Models_lfrazier.rvt A9.02 ROOF DETAILS 14054.1 CHAMONIX - VAIL TOWN OF VAIL PERMIT SET MAY 31, 2017 1 1/2" = 1'-0" 2 TYP. SHED ROOF EAVE 1 1/2" = 1'-0" 5 ROOF RIDGE VENT 1 1/2" = 1'-0" 3 TYP. UPPER ROOF EAVE OVER LOW ROOF 1 1/2" = 1'-0" 4 TYP. EYEBROW ROOF No. Description Date 1 1/2" = 1'-0" 1 TYP. LOWER ROOF EAVE 06/26/17