HomeMy WebLinkAboutB17-0069_A9-03_1498508428.pdfEACH SIDE OF DEMISING WALL TO BE DISCONTINUOUS SO EITHER SIDE CAN FAIL WITHOUT AFFECTING THE OTHER SIDE 2-HR UNIT DEMISING WALL; WALL TYPE E1, RE: A0.01 FOR ALL STANDARD WALL TYPES 1"x3" PT WOOD BLOCKING RAINSCREEN SYSTEM, RE: SPEC. 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR. 1" R-5 MIN. FOIL FACED POLYISO, RE: SPEC. HORZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC MIN. R-20 UNFACED BATT INSULATION, RE: SPEC. MEMBRANE FLASHING, WRAP CORNER MIN. 4" PREFINISHED ALUMINUM J CLOSURE 1"x3" PT WOOD BLOCKING RAINSCREEN SYSTEM, RE: SPEC. 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR. 1" R-5 MIN. FOIL FACED POLYISO, RE: SPEC. MIN. R-20 UNFACED BATT INSULATION, RE: SPEC. MEMBRANE FLASHING, WRAP CORNER MIN. 4" 2 COAT STUCCO SYSTEM OVER GALVANIZED METAL LATH, RE: SPEC 1"x3" PT WOOD BLOCKING RAINSCREEN SYSTEM, RE: SPEC. 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR. 1" R-5 MIN. FOIL FACED POLYISO, RE: SPEC. 11/16" HORZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC MIN. R-20 UNFACED BATT INSULATION, RE: SPEC. MEMBRANE FLASHING, WRAP CORNER MIN. 4" 5/4"x4" WOOD TRIM, RE: SPEC 2 COAT STUCCO SYSTEM OVER GALVANIZED METAL LATH, RE: SPEC EACH SIDE OF DEMISING WALL TO BE DISCONTINUOUS SO EITHER SIDE CAN FAIL WITHOUT AFFECTING THE OTHER SIDE DEMISING WALL; WALL TYPE E1 RE: A0-01 FOR ALL STANDARD WALL TYPES RAINSCREEN SYSTEM, RE: SPEC MEMBRANE FLASHING, WRAP CORNER MIN. 4" 1"x3" PT WOOD BLOCKING 1" R-5 MIN FOIL FACED POLYISO, RE: SPEC MIN. R-20 UNFACED BATT INSULATION, RE: SPEC 7/16" EXTERIOR OSB SHEATHER, RE: SYSTEMS BUILT MFR NOTE: DETAILS DO NOT REFLECT ALL EXTERIOR CLADDING CONDITIONS - SEE PLANS AND ELEVATIONS FOR BUILDING MATERIALS 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR. 2-HR DEMISING WALL; WALL TYPE E1, RE: A-0.01 FOR ALL STANDARD WALL TYPES EACH SIDE OF DEMISING WALL TO BE DISCONTINUOUS SO EITHER SIDE CAN FAIL WITHOUT AFFECTING THE OTHER SIDE 2 COAT STUCCO SYSTEM OVER GALVANIZED METAL LATH, RE: SPEC MIN. R-20 UNFACED BATT INSULATION. RE: SPEC. 1" R-5 MIN. FOIL FACED POLYISO, RE: SPEC RAINSCREEN SYSTEM, RE: SPEC EACH SIDE OF DEMISING WALL TO BE DISCONTINUOUS SO EITHER SIDE CAN FAIL WITHOUT AFFECTING THE OTHER SIDE 2-HR UNIT DEMISING WALL; WALL TYPE E1, RE: A0.01 FOR ALL STANDARD WALL TYPES 1"x3" PT WOOD BLOCKING RAINSCREEN SYSTEM, RE: SPEC. 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR. 2 COAT STUCCO SYSTEM OVER GALVANIZED METAL LATH, RE: SPEC 1" R-5 MIN. FOIL FACED POLYISO, RE: SPEC. HORZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC MIN. R-20 UNFACED BATT INSULATION, RE: SPEC. STUCCO J BEAD CLOSER MEMBRANE FLASHING, WRAP CORNER MIN. 4" PREFINISHED ALUMINUM J CLOSURE PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP 6/1/2017 2:19:54 PM C:\Users\lfrazier\Documents\CHAMONIX_Building Models_lfrazier.rvt A9.03 PLAN DETAILS 14054.1 CHAMONIX - VAIL TOWN OF VAIL PERMIT SET MAY 31, 2017 1 1/2" = 1'-0" 2 TYP. INSIDE CORNER @ WOOD SIDING 3" = 1'-0" 5 TYP. STUCCO SIDING OUTSIDE CORNER 3" = 1'-0" 6 TYP. WOOD SIDING OUTSIDE CORNER 1 1/2" = 1'-0"1 TYP. DETAIL INSIDE CORNER @ STUCCO 1 1/2" = 1'-0" 4 TYP. DETAL @ DEMISING WALL INTERSECTION 1 1/2" = 1'-0" 3 TYP. INSIDE CORNER @ WOOD SIDING & STUCCO No. Description Date 06/26/17