Loading...
HomeMy WebLinkAboutB17-0069_G0-00-04_1498508400.pdfDRAWING ABBREVIATIONS GENERAL NOTES ROOM NAME XXXXX X X 1 A0.X X X A3 A3 ROOM NAME/NUMBER EXISTING COLUMN CENTERLINE COLUMN CENTERLINE ACCESSORY DEMOLITION NUMBERED NOTES BUILDING WALL SECTION ELEVATION SECTION DETAIL PLAN, BLOW-UP DETAIL PARTITION TYPE WITH NO SOUND ATTENUATION PARTITION TYPE WITH SOUND ATTENUATION SYMBOLS BUILDING EXPANSION JOINT GYP BD CEILING SUPPLY AIR RETURN AIR ACCESS PANEL FLUORESCENT LIGHT WALL MOUNTED FLUORESCENT FIXTURE EXIT SIGNS - HATCH INDICATES EXIT TEXT AND ARROW INDICATES DIRECTION SMOKE DETECTOR WALL WASHER PENDANT TYPE LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE DOWNLIGHT STRIP LIGHT SPEAKER S D 01 +9'-0" CEILING HEIGHT S EXHAUST AIR A0.X X 01 SUSPENDED LIGHT SUSPENDED FLUORESCENT LIGHT CHANDELIER PROJECTOR A0.X X 01 A0.X X AB ANCHOR BOLT ACT ACOUSTICAL TILE CEILING AFF ABOVE FINISH FLOOR ALUM ALUMINUM AP ACCESS PANEL APPROX APPROXIMATE ARCH ARCHITECTURE ASSOC ASSOCIATED BD BOARD BLDG BUILDING BLK BLOCK BO BOTTOM OF BOT BOTTOM BRG BEARING BSMT BASEMENT CJ CONTROL JOINT CL CENTERLINE CLG CEILING CLR CLEAR CMU CONCRETE MASONRY UNIT COL COLUMN CONC CONCRETE CONT CONTINUOUS COVR COVER CPT CARPET CT CERAMIC TILE CTR CENTER DEC DETENTION EQUIPMENT CONTRACTOR DET DETENTION DEMO DEMOLITION DIA DIAMETER DIM DIMENSION DF DRINKING FOUNTAIN DGB DETENTION GRAB BAR DR DOOR DWG DRAWING EA EACH EJ EXPANSION JOINT ELEC ELECTRICAL ELEV ELEVATOR EQ EQUAL EQUIP EQUIPMENT ER EPOXY RESIN EXT EXTERIOR FD FLOOR DRAIN FDN FOUNDATION FE FIRE EXTINGUISHER FF EL FINISH FLOOR ELEVATION FIN FINISH FRT FIRE RESISTANT TREATED FLR FLOOR FS FOOD SERVICE FT FOOT FTG FOOTING FUT FUTURE GA GUAGE GC GENERAL CONTRACTOR GL GLASS GR GRADE GYP BD GYPSUM BOARD HC HOLLOW CORE HT HEIGHT HM HOLLOW METAL HORIZ HORIZONTAL INT INTERIOR INSUL INSULTATION JAN JANITOR JST JOIST LAV LAVATORY MAX MAXIMUM MECH MECHANICAL 1. DO NOT SCALE DRAWINGS. LARGE SCALE DETAILS SHALL GOVERN OVER SMALL SCALE DETAILS. SPECIFICATIONS GOVERN ALL. 2. CONTRACTOR TO ISSUE COMPLETE SET OF CONTRACT DOCUMENTS TO EACH SUBCONTRACTOR FOR COORDINATION OF WORK AND DESCRIPTION OF SCOPE 3. THERE SHALL BE NO SUBSTITUTION OF MATERIALS WHERE A MANUFACTURER IS SPECIFIED. WHERE THE TERM "OR EQUAL" IS USED THE ARCHITECT ALONE SHALL DETERMINE EQUALITY BASED ON INFORMATION SUBMITTED BY THE CONTRACTOR. 4. REFER TO STRUCTURAL DRAWINGS FOR ALL REINFORCING. 5. ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND NON-STRUCTURAL SYSTEMS, COMPONENTS AND ELEMENTS PERMANENTLY ATTACHED TO STRUCTURES, INCLUDING SUPPORTING STRUCTURES AND ATTACHMENTS AND NON-BUILDING STRUCTURES THAT ARE SUPPORTED BY OTHER STRUCTURES, SHALL MEET THE REQUIREMENTS PER 2009 IBC CHAPTER 16 AND ASCE 7-02 SECTION 9.6 COORDINATE DESIGN WITH ARCHITECT AND ENGINEER OF RECORD. 6. STUCCO ASSEMBLY REQUIRES (2) AIR-INFILTRATION LAYERS AS A BOND BREAK BETWEEN THE WALL ASSEMBLY AND THE STUCCO APPLICATION. MEM MEMBRANE MFR MANUFACTURER MIN MINIMUM MR MOISTURE RESISTANT MTL METAL NIC NOT IN CONTRACT NO NUMBER NOM NOMINAL NTS NOT TO SCALE OA OVERALL OAM OVERALL MASONRY OC ON CENTER OH OVERHEAD ORD OVERFLOW ROOF DRAIN OS OVERFLOW SCUPPER OPG OPENING OPOI OWNER PROVIDED OWNER INSTALLED OPCI OWNER PROVIDED CONTRACTOR INSTALLED PC PRECAST PF PREFINISHED PJ PANEL JOINT PL PLATE PLAM PLASTIC LAMINATE PLMG PLUMBING PNL PANEL PT PRESSURE TREATED PTD PAPER TOWEL DISPENSER REINF REINFORCED REQ REQUIRED REV REVISED RD ROOF DRAIN RM ROOM RO ROUGH OPENING SAP SECURE PANEL ACCESS SC SEALED CONCRETE SCHED SCHEDULED SEC SECURITY SECT SECTION SHT SHEET SHWR SHOWER SK SINK SPEC SPECIFICATIONS SS STAINLESS STEEL STL STEEL STIFF STIFFENER STRUCT STRUCTURAL T&G TONGUE AND GROOVE TO TOP OF TOF TOP OF FOOTING TPH TOILET PAPER HOLDER TS TUBE STEEL TYP TYPICAL UNO UNLESS NOTED OTHERWISE VAR VARIES VB VAPOR BARRIER VCT VINYL COMPOSITE TILE VERT VERTICAL VIF VERIFY IN FIELD VT VINYL TILE VTR VENT THROUGH ROOF VWC VINYL WALL COVERING W WITH WC WATER CLOSET WD WOOD WDW WINDOW WP WATERPROOF WT WALL TYPE WWF WELDED WIRE FABRIC PROJECT TEAM LANDSCAPE OUTSIDE LA 2623 BURGESS CREEK ROAD STEAMBOAT SPRINGS, CO 80487 CONTACT: SANDI GIBSON OSLA@ME.COM MEP SGM ENGINEERS 118 W SIXTH ST, SUITE 200 GLENWOOD SPRINGS, CO 81601 CONTACT: MIKE SUHRBIER PHONE: (970) 384-9032 CIVIL MARTIN/MARTIN, INC. 0101 FAWCETT RD UNIT 260 PO BOX 8896 AVON, CO 81620 CONTACT: MASON TALKINGTON, PE PHONE: (970) 926-6007 ARCHITECTURE/INTERIORS 359 DESIGN, LLC 710 WEST COLFAX AVENUE DENVER, COLORADO 80204 CONTACT: WILLIAM HENTSCHEL WHENTSCHEL@359ARCH.COM PHONE: (303) 884-9131 DEVELOPER TRIUMPH DEVELOPMENT 12 VAIL ROAD SUITE 700 VAIL, CO 81657 CONTACT: MICHAEL O'CONNOR MICHAEL@TRIUMPHDEV.COM PHONE: (970) 688-5057 OWNER COMMUNITY DEVELOPMENT CONTACT: GEORGE RUTHER, AICP GRUTHER@VAILGOV.COM PHONE: (970) 479-2145 GEOTECHNICAL CESARE, INC. P.O. BOX 23052 CONTACT: IAN CESARE PHONE: (303) 520-1420 GENERAL CONTRACTOR R.A. NELSON 51 EAGLE ROAD #2 P.O. DRAWER 5400 AVON, CO 81620 CONTACT: MIKE CUTHBERTSON MCUTHBERTSON@RANELSON.COM PHONE: (970) 748-7662 STRUCTURAL SGM ENGINEERS 118 W SIXTH ST, SUITE 200 GLENWOOD SPRINGS, CO 81601 CONTACT: JOHN E. PARTCH MIKE SUHRBIER PHONE: (970)-384-9032 CONCRETE/ PRECAST CONCRETE SOIL SAND, EIFS FINISH COAT BRICK CMU STONE XPS RIGID INSULATION FIBERGLASS BATT INSULATION GYPSUM BOARD OR FIBERGLASS- REINFORCED GYPSUM BOARD PLYWOOD COVER BOARD MATERIALS CEILING SYMBOLS FOIL-FACED POLYISO RIGID INSULATION ccSPF - CLOSED CELL SPRAY POLYISO FOAM INSULATION INDEX OF DRAWINGS SYSTEMS BUILT MANUF. NASHUA BUILDERS 5200 S. FEDERAL WAY BOISE, ID 83716 CONTACT: SHAIN ZENOR SZENOR@NASHUABUILDERS.COM PHONE: (208) 345-0222 SPEC WRITER ARCHITECTURAL SPECIFICATION WRITER CONTACT: MARIA STONE STONEMARIA@Q.COM PHONE: (303) 681-3611 CHAMONIX - VAIL 2310 CHAMONIX RD VAIL, COLORADO 81657 PROJECT SITE 1"=400' PROJECT LOCATION TOWN OF VAIL PERMIT SET PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP 6/1/2017 2:20:01 PM C:\Users\lfrazier\Documents\CHAMONIX_Building Models_lfrazier.rvt G0.00-04 TITLE SHEET - BUILDING 04 14054.1 CHAMONIX - VAIL TOWN OF VAIL PERMIT SET MAY 31, 2017 ARCHITECUTRE - BUILDING 04 SHEET NUMBER SHEET NAME A0.01 STANDARD PARTITIONS & EXTERIOR ASSEMBLIES A0.04 ARCHITECTURAL SITE PLAN A2.01-04 BUILDING 04 - FLOOR PLANS A2.02-04 BUILDING 04 - FLOOR PLANS A3.01-04 BUILDING 04 - UNIT 2.1 A - LEVEL 01 A3.02-04 BUILDING 04 - UNIT 2.1 A - LEVEL 02 A3.03-04 BUILDING 04 - UNIT 3.2 A - LEVEL 01 A3.04-04 BUILDING 04 - UNIT 3.2 A - LEVEL 02 A3.05-04 BUILDING 04 - UNIT 3.2 A - LEVEL 03 A3.06-04 BUILDING 04 - UNIT 2.2 A - LEVEL 01 A3.07-04 BUILDING 04 - UNIT 2.2 A - LEVEL 02 A3.08-04 BUILDING 04 - UNIT 2.2 A - LEVEL 03 A4.01-04 BUILDING 04 - ELEVATIONS A5.01-04 BUILDING 04 - SECTIONS A5.02-04 BUILDING 04 - SECTIONS A6.01 INTERIOR ELEVATIONS & STAIRS - UNIT 2.1 A6.02 INTERIOR ELEVATIONS & STAIRS - UNIT 2.2 A6.04 INTERIOR ELEVATIONS & STAIRS - UNIT 3.2 A6.06 INTERIOR SCHEDULES A6.07 INTERIOR DETAILS A8.01-04 WINDOW AND DOOR - SCHEDULES A8.02 WINDOW AND DOOR - TYPICAL DETAILS A9.02 ROOF DETAILS A9.04 DEMISING WALL DETAILS A9.05 FOUNDATION DETAILS A6.08 INTERIOR DETAILS A9.01 EXTERIOR DETAILS A9.03 PLAN DETAILS ARCHITECUTRE - BUILDING 04 SHEET NUMBER SHEET NAME G0.00-04 TITLE SHEET - BUILDING 04 G0.01-04 CODE STUDY STRUCTURAL - BUILDING 04 SHEET NUMBER SHEET NAME S0.00-04 GENERAL STRUCTURAL NOTES & SCHEDULES S1.01-04 FOUNDATION & 1ST LEVEL WALL FRAMING PLANS S1.02-04 LEVEL 2 & 3 FLOOR & FRAMING PLANS S1.03-04 LEVEL 4 ROOF FRAMING & ROOF LOADING PLANS S5.00-04 CONCRETE DETAILS S5.01-04 FOUNDATION DETAILS S5.02-04 FOUNDATION DETAILS (2) S5.03-04 STEEL FRAMING DETAILS S5.04-04 WOOD FRAMING DETAILS S5.05-04 TRUSS LOADING DIAGRAMS S5.06-04 ROOF FRAMING DETAILS S5.07-04 ROOF FRAMING DETAILS (2) MEP - BUILDING 04 SHEET NUMBER SHEET NAME P-3.05-04 Building 04 - Unit 2.2A - Level 1 & Level 2 Plumbing Plans P-3.06-04 Building 04 - Unit 2.2A - Level 3 & Roof Level Plumbing Plans P-5.01-04 Plumbing Details P-6.01-04 Plumbing Schedules P-6.02-04 Plumbing Notes & Specifications MEP - BUILDING 04 SHEET NUMBER SHEET NAME P-0.01-1 MEP Site Plan M-2.01-04 Building 04 - Level 1 & Level 2 Mechanical Plans M-2.02-04 Building 04 - Level 3 & Roof Level Mechanical Plans M-3.01-04 Building 04 - Unit 2.1A - Level 1 & Level 2 Mechanical Plans M-3.02-04 Building 04 - Unit 2.1A - Level 3 & Roof Level Mechanical Plans M-3.03-04 Building 04 - Unit 3.2A - Level 1 & Level 2 Mechanical Plans M-3.04-04 Building 04 - Unit 3.2A - Level 3 & Roof Level Mechanical Plans M-3.05-04 Building 04 - Unit 2.2A - Level 1 & Level 2 Mechanical Plans M-3.06-04 Building 04 - Unit 2.2A - Level 3 & Roof Level Mechanical Plans M-5.01-04 Mechanical Details M-6.01-04 Mechanical Schedules M-6.02-04 Mechanical Notes E-2.01-04 Building 04 - Level 1 & Level 2 Electrical Plans E-2.02-04 Building 04 - Level 3 & Roof Level Electrical Plans E-3.01-04 Building 04 - Unit 2.1A - Level 1 & Level 2 Electrical Plans E-3.02-04 Building 04 - Unit 2.1A - Level 3 & Roof Level Electrical Plans E-3.03-04 Building 04 - Unit 3.2A - Level 1 & Level 2 Electrical Plans E-3.04-04 Building 04 - Unit 3.2A - Level 3 & Roof Level Electrical Plans E-3.05-04 Building 04 - Unit 2.2A - Level 1 & Level 2 Electrical Plans E-3.06-04 Building 04 - Unit 2.2A - Level 3 & Roof Level Electrical Plans E-5.01-04 Electrical Details E-5.02-04 Electrical Diagrams E-6.01-04 Electrical Schedules P-2.01-04 Building 04 - Level 1 & Level 2 Plumbing Plans P-2.02-04 Building 04 - Level 3 & Roof Level Plumbing Plans P-3.01-04 Building 04 - Unit 2.1A - Level 1 & Level 2 Plumbing Plans P-3.02-04 Building 04 - Unit 2.1A - Level 3 & Roof Level Plumbing Plans P-3.03-04 Building 04 - Unit 3.2A - Level 1 & Level 2 Plumbing Plans P-3.04-04 Building 04 - Unit 3.2A - Level 3 & Roof Level Plumbing Plans CIVIL SHEET NUMBER SHEET NAME C100 GRADING PLAN C101 GRADING PLAN CONT'D C102 GRADING PLAN CONT'D C104 GRADING DETAILS C106 UTILITY SITE WALLS C200 OVERALL UTILITY PLAN C213 PERIMETER DRAIN PLAN C214 PERIMETER DRAIN PLAN FIRE PROTECTION SHEET NUMBER SHEET NAME FP3.01 UNIT 2.1 A - FIRE PROTECTION & FIRE ALARM FP3.02 UNIT 2.2 A - FIRE PROTECTION & FIRE ALARM FP3.03 UNIT 3.1 A - FIRE PROTECTION & FIRE ALARM FP3.04 UNIT 3.2 A - FIRE PROTECTION & FIRE ALARM FP3.05 UNIT 3L.2 A - FIRE PROTECTION & FIRE ALARM BUILDING 04 LANDSCAPE SHEET NUMBER SHEET NAME L1.00 LANDSCAPE MASTER PLAN L1.01 LANDSCAPE PLAN WEST L1.02 LANDSCAPE PLAN EAST L2.00 LANDSCAPE NOTES & DETAILS IR1.01 IRRIGATION PLAN IR2.01 IRRIGATION DETAILS No. Description Date 06/26/17