HomeMy WebLinkAboutB17-0069_G0-01-04_1495580715.pdf1 HR RATING THIS
SECTION OF WALL
NOTE: ALL GARAGE CEILINGS
ARE REQUIRED TO HAVE 5/8"
TYPE 'X' GYPSUM BOARD
1 HR RATING THIS
SECTION OF WALL
1 HR RATING WITH
SPRINKLER REDUCTION
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING WITH
SPRINKLER REDUCTION
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING WITH
SPRINKLER REDUCTION
HATCHED AREA INDICATES 4'-0" OFF
OF DEMISING WALL CENTERLINE.
F.R.P. SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA
PARTITION LEGEND
1 HR BARRIER
2 HR BARRIER
(1 HR EA. SIDE)
REFERENCE A0.01 FOR WALL TYPES
1 HR BARRIER ONE SIDE
2 HR BARRIER ONE SIDE
5/8" TYPE "X" GYP. BD.
LEVEL 1
100' - 0"
LEVEL 2
111' - 0"
04-A 04-B 04-C 04-D
LEVEL 3
122' - 0"
LEVEL 4
133' - 0"
2 CAR GARAGE
2 CAR GARAGE ENTRY 1 CAR GARAGE BATH ENTRY
CLOSET DINING BEDROOM LIVING
DINING
CLOSET
LAUNDRY MASTER
BATH
MASTER
BEDROOM
1 HR HORIZONTAL RATING 4'-0"
EITHER SIDE OF DEMISING WALL
CENTERLINE. F.R.P. SHEATHING
REQUIRED IN ROOF ASSEMBLY
FOR THIS AREA
2 HR RATING TO UNDERSIDE OF
UPPER ROOF
1 HR RATED SOFFIT
1 HR HORIZONTAL RATING 4'-0"
1 HR RATING TO UNDERSIDE OF
LOWER ROOF
TYPICAL 1 HR VERTICAL UNIT
DEMISING WALL RATING WITH
SPRINKLER REDUCTION
HATCH REPRESENTS UNVENTED
ROOF ASSEMBLY
5/8" GYP. BD. BETWEEN GARAGE AND
FINISHED SPACE AT WALLS AND CEILING
A9.04
3
A9.04
3
A9.04
1
A9.04
9
A9.04
5
A9.04
4
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
FOR REFERENCE
ONLY
4/26/2017
11:32:21 AM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
G0.01-04
CODE STUDY
14054.1
CHAMONIX - VAIL
FOUNDATION PERMIT
APRIL 26, 2017
1/16" = 1'-0" 1 LEVEL 01
1/16" = 1'-0"
2 LEVEL 02
1/16" = 1'-0"
3 LEVEL 03
1/16" = 1'-0"
4 ROOF
1/8" = 1'-0" 5 CODE SECTION 1-4
No. Description Date
1
1
1 FOUNDATION PERMIT COMMENTS 05/17/17
05/23/17