Loading...
HomeMy WebLinkAboutB08-0001TOAVN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 8 DEPARTMENT OF COMM DEVELOPMENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ADD/ALT COMM BUILD PERMT Permit # B08-0001 Project # PRJ08-0003 Job Address: 710 W LIONSHEAD CR VAIL Status ... Location.......: 710 W. LIONSHEAD CR. UNIT'A' Applied ... Parcel No....: 210106317056 Issued ... Expires.....: OWNER WEBB, KYLE & LORAINNE PO BOX 2630 EDWQARDS CO 81632 ARCHITECT K.H. WEBB ARCHITECTS PC 710 WEST LIONSHEAD CIR, VAIL CO 81657 License: 0000001627 APPLICANT T. HORN ENTERPRISES INC. PO BOX 552 EDWARDS COLORADO 81632 License: 926-B CONTRACTOR T. HORN ENTERPRISES INC. ,+ PO BOX 552 EDWARDS COLORADO 81632 License: 926-B 01/03/2008 ~o~ v~~ s ~ ~- ~~ ~. ISSUED O 1 /03/2008 03/27/2008 09/23/2008 01/03/2008 Phone: 970-477-2990 UNIT A 01/03/2008 Phone: (970) 390-5111 01/03/2008 Phone: (970) 390-5111 Desciption: VAIL SPA OFFICE SPACE CONVERSION-DEMO KITCHEN AND CONVERT TO OFFICE SPACE Occupancy: B Type Construction: IIA Valuation: $40,997.00 Revision Valuation: $0.00 Total Sq Ft Added: 0 ###################*##**#####*#########*##**####*#*####****#*####### FEE SUMMARY ########+#*########*#####*########*# ##*####**##############* Building------> $552.85 Restuarant Plan Review--> $0.00 Total Calculated Fees--> $916.20 Plan Check---> $ 3 5 9 . 3 5 Recreation Fee-------------> S o . 0 0 Additional Fees----------> $ 619.94 Investigation-> $ 0 . o o TOTAL FEES-------------> S 916 .2 0 Total Permit Fee---------> $1 , 5 3 6.14 Will Call-----> $4.00 Payments-----------------> $1, 536.14 BALANCE DUE---------> $0.00 ##########f#################f#-###tit########i###################f#########################################################################ti#### Approvals: Item: 05100 BUILDING DEPARTMENT 01/17/2008 jplano Action: DN see correction letter, F:\cdev\CHRIS\PERMIT~MMENTS\B08-0001\BOS-OOOl.DO 02/29/2008 jplano Action: CR Second letter sent.F:\cdev\CHRIS\PERMIT.COMMENTS\B08-0001\B08-0001.2.DOC 03/27/2008 jplano Action: AP Item: 05400 PLANNING DEPARTMENT 01/09/2008 RLF Action: AP Item: 05600 FIRE DEPARTMENT 01/09/2008 JJR Action: AP Provide stamped shop drawings for fire sprinkler and fire alarm systems. Item: 05500 PUBLIC WORKS #i####i####################################ii#################################################################################################### See the Conditions section of this Document for any conditions that may apply to this permit. DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM 4 PM• ~. SIGNATURE 4F OWNER OR CONTRACTOR FOR HIMSELF AND OWNI:K • L J ******************************************************************************************************** CONDITIONS OF APPROVAL Permit #: B08-0001 as of 03-27-2008 Status: ISSUED ******************************************************************************************************** Permit Type: ADD/ALT COMM BUILD PERMT Applicant: T. HORN ENTERPRISES INC. 03/27/2008 (970) 390-5111 Job Address: 710 W LIONSHEAD CR VAIL Location: 710 W. LIONSHEAD CR. UNIT'A' Parcel No: 210106317056 Description: VAIL SPA OFFICE SPACE CONVERSION-DEMO KITCHEN AND CONVERT TO OFFICE SPACE Applied: 01/03/2008 Issued: To Expire: 09/23/2008 ***********************************************Conditions:************************************************ Cond: 1 (FIRE): FIRE DEPARTMENT APPROVAL IS REQUIRED BEFORE ANY WORK CAN BE STARTED. Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. • TOWN OF VAIL, COLORADO Statement ***+****~***r********************************~******+****~********+**************+********** Statement Number: 8080000351 Amount: $1,536.14 03/27/200810:02 AM Payment Method: Check Init: LC Notation: #2775/T. HORN ENTERPRISES Permit No: B08-0001 Type: ADD/ALT COMM BUILD PERMT Parcel No: 2101-063-1705-6 Site Address: 710 W LIONSHEAD CR VAIL Location: 710 W. LIONSHEAD CR. UNIT 'A' Total Fees: $1,536.14 This Payment: $1,536.14 Total ALL Pmts: $1,536.14 Balance: $0.00 ************~*********************s**************************************+***+************** ACCOUNT ITEM LIST: Account Code Description Current Pmts -------------------- ------------------------------ ------------ BP 00100003111100 BUILDING PERMIT FEES 552.85 PF 00100003112300 PLAN CHECK FEES 359.35 UT 11000003106000 USE TAX 4$ 619.94 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 ~. u ~~ ~ ~ r ii ``~ APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR,UNSIG~~~ ,~ ~~ Froge Rd. Vail, Colorado 81657 Project#: Buiidin Permit #• • Separate etc.l Far Parcel # Contact Eagle County Assessors Office at 970-3ZB-864! or visit www.aa~le-countf~ com t© 6 Job Name: _ Job Address: ~qi L w Of-/`.`ct ~~{ ~!O w~:ows aws/ Ltd [t do •'( f fb Legal Descri~ion Lot: ~ Block: Filing: Subdivision: Owners. I game: f K Address: . o. Qo 3 O Fdl~or~ l o. Phone: mgr Address: P ~~ ~ l.'J f c 4~ 'Fec.'!-s )~ o W ~ ass .Ae.l G%~ >d s i f /4 t L (.~. ~1 0 Engineer: Address: Detailed descriptioJn o/f work: ADO rCRl~l ~V/R~~N,}O ~I~~~aG S .ate Work Class: New O Addition ( ) Remodel (~ Repair ( ) Demo ~ Other ( ) Work Type: Interior (pQ Exterior ( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( ) Type of Bkig.: Single-family ( )Two-family ( ) Mull-family ( ) .Commercial fp(~ Restaura )~ Q No. of Existing Dwelling Units in this building:. No. of Accommodation in this building: No/T of Fire laces Existin Gas A lances Gas L s Wood/Pellet Burnin Noll of Fire aces Pro sed: Gas A lances Gas Los Wood/Pellet WED Does a ire Alarm Exist: Yes pQ No ( ) Does a Fire Sprinkler Sys FOR OFFICE USE ONL ~- l 5 ~ ~C F:~adevlFORMS~Perrnits+9 i~.417-2007.DOC Page 1 of 7 04/17/2007 ~la~ik~ ~d'tn ,r -~ ~ 0 u ~~~~~ BUILDING PERMIT APPLICATION CHECKLIST r~nnnMGR['_1~1 TENANT FINISH/IMPROVEMENT This checklist is to be used with any tenant finish/improvement perrnn aNN~~~a~~~~ ~• ^ Town of Vail Design Review Board approval must first be obtained for any exterior modifications proposed ^ Plan Check Fee must be paid at the time of application for projects over $100,000 valuation (see attached schedule) The following information must be shown on all 4 sets of plans: ^ Construction plans stamped and signed by a Colorado State Licensed Architect. ^ Original building construction type per IBC chapter 6 ex. II-A, V-B ^ Tenant suite or tenant space number. ^ Tenant space location identification. Show location of the tenant space within the overall building. ^ Floor plans with existing and proposed walls. Show all wall assembly construction and proposed interior finishes with flamespread index. Proposed construction type must match existing building construction type. Clearly show proposed use of each room or space on the plans. ^ Reflected ceiling and finish plan. Type of materials must match the fire resistance/type of construction requirements in the existing building. Show all interior ceiling finishes and flamespread index ^ Door schedule. All doors shall be clearly identified with fire rating, size, hardware and swing. ^ Means of egress plan. Show all occupant loads and number of exits from the tenant space ^ Areas requiring two (2) exits: Exit doors shown to swing in the direction of exit travel, separation of exits comply with code, illuminated exit signs are shown. ^ Windows shall be labeled with size, operation, safety glass. ^ All areas and rooms of the tenant space are accessible per ANSI 117.1 requirements. ^ Accessible maneuvering clearances provided at all doors for accessibility per ANSI 117.1 ^ Service counter-tops and built-in work stations provided with accessible areas per ANSI 117.1 ^ Bathroom facilities. All accessible/adaptable features, clearances and turning spaces provided per ANSI 117.1 requirements must be shown. ^ Separate sex bathroom facilities provided if the number of occupants or employees exceeds (15). ^ Toilet room floorslwalls finish schedule. ^ Floors have a smooth, hard, nonabsorbent surface such as concrete, ceramic the or other approved material, extending upward onto the walls at least 5". ^ Walls within 2 feet of the front and sides of urinals and water closets must have a smooth, hard nonabsorbent surface to a height of 4 feet. ^ Occupancy separations for walls/ceilings between tenants clearly shown on the plans with fire resistive construction details and listings specified. ^ Fire-stopping. Fire-stopping penetration details for plumbing, mechanical and electrical components in all fire rated walls and ceilings. ^ Plumbing, Electrical and Mechanical Plans stamped by a Colorado State Licensed Engineer Mechanical HVAC plans, plumbing plans, electrical plans/panel schedules/load calculations. ^ Fire/smoke Dampers on mechanical plans at all duct penetrations into fire resistive walls and ceilings. ^ Fire sprinkler plans. Show all proposed work per Vail Fire and Emergency Services requirements ^ Fire alarm plans. Show all proposed work per Vail Fire and Emergency Services requirements I have read and understand the requirements of this checklist. If any required information is missing from the application, Iypfler nd the application will not be accepted. s Signature 2~~2 Date Page 3 of 7 04/17/2007 F:\cdev\FORMS\Permits\Building\buildi ng~ermit_4-17-2007. DOC ~~~ Department of community Deve%pment Building Safety and Inspection Services 75 South F~onbge Road fail, Co%rado 81657 970-479 2138 FAX 970-4792452 www. vailgov.com • S pM,~ ,ir/q. ~p ~~~ O't~ice ~opY BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: This is the second correction letter; please respond to the bold comment following the original comment. TO: Contractor/Applicant Architect T. Horn Enterprises K.H. Webb FAX/Email #: thorn@centrytel.net NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: proj# space (970)477-2965 3 John Plano, Building Plans Examiner 02/29/2008 B08-0001 Vail Spa Office 710 W. Lionshead Circle Unit A B IIA unknown unknown The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior to issuance of a bui/ding permit; For processing: • Please submit four complete sets of revised construction documents containing the reauested information with all plan revision items clouded or otherwise identified. • Please re~ond in writin~c to each comment by marking the attached list or creating a response letter Indicate which plan sheet detail specification or calculation shows the reauested information Please send revisions to the attention of the plans examiner with the building hermit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's'~wet" stamp, signature, registration number and date on the cover page of any structural calculations, all structural details and structural sheets of the plans For commercial or multi-family projects all sheets of theplans must be stamped. Architectural Comments: 1 Please refer to the Building Department Checklist for Commercial Tenant Finish/Improvement" for information required to be included to proceed with further review of this project. Provide all items on the list. 2 Provide an egress plan. From the tenant space to exit discharge. (IBC Chapter 10) 2.1 The Vail Spa Level Plan is not legible enough to determine what the uses are of the spaces. Please provide legible plans indicating occupancy classification of surrounding rooms and clearly show exit path to exit discharge. 2.2 Exit discharge is the means of egress system between the termination of an exit and the public way. The egress plan indicates a double door at the top of the page as exit discharge, this does not appear to be outside the building. (IBC 1002.1) 2.3 The door at the end of what is labeled as exit corridor appears to enter a parking garage, this does not constitute exit discharge. Exiting through a parking garage is not permitted. (IBC 1013.2) 2.4 Remove the exit sign from above 1/101. Door 1/102 appears to be the only legitimate exit door. The occupant load and travel distance in this space will indicate the need for one exit. See comment 2.1. (IBC 1014.1) 2.5 The corridor accessed from door 1/102 appears to be a rated corridor as it serves residential occupancies. Add the one hour wall type to the drawings and change door 1/102 to a 20 minute door. (IBC 1016.1) 3 Provide engineer stamped electrical plans and mechanical plans, provide a ComCheck compliance certificate for lighting. (see checklist) 3.1 Provide complete engineer stamped mechanical plans, demolition and new construction. These plans are also to include location of all fire dampers and smoke dampers where applicable. Please include the ventilation rates at each louver. 3.2 Provide engineer stamped plumbing demo plans. Indicate if any existing pipes in the space that have to stay to serve as vents for fixtures below. Provide fire-stop details to patch the holes in the or. (IBC 712) 3.3 Provi a the mechanical and electrical ComCheck report for verification with the energy code. (IBC Ch er 13) 7 The drawings are indicting two new doors, one is 20 minute and one is glass French. Sheet A20 indicates the glass French door leads to a common corridor. Please verify if the corridor is rated. (see checklist for egress plan and location identification within the overall building) (IBC 1016) 7.1 The "French door" 1/102 is to be rated to 20 minute. See comment 2.5. (IBC 715.3) 9 There appear to be glass adjacent to door 1/101. If the corridor, accessed by the new door, is rated the glass will be required to be 45 minute. (IBC Table 715.4) The response is referencing door 1/102. The comment indicates door 1/101, which is shown as 20 minute. Based on the existing floor plans supplied it appears that the corridor marked as Exit Corridor does not need to be rated. This will be confirmed with the legible existing plans requested in comment 2.1. • ~J Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. John Plano I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.479.2140 iplanoCwailg_ov.com ., . • ~'>) ~` i Q ~ a~ 3 a t v 03.20.06 BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS- REPLY (21: T0: John Plano, Building Plans Examiner FROM: Kyle Webb & Lauren Ford, K H. Webb Architects 910.411.2990 Building Permit #: 608-0001 OWNERS NAME: Vail Spa Office SITE ADDRESS: 110 West Lionshead Circle Unit A OCCUPANCY GROUP: B TYPE OF CONSTRUCTION: IIA Architectural Comments: I. Please refer to the "Building Dept. Checklist for Commercial Tenant Finish/ Improvement" for information required to be included to proceed with further review of this project. Ok. 2. Provide an egress plan. From the tenant space to discharge. (IBC chapter 10) See Code plan sheet A001, and attached Original Vail Spa Plan sheet. 2.1 See attached Vail Spa Level plan. 2.2 The double door exit leads to a loading dock; I have changed my notes to only reference the other exit. 2.3 I have changed my note on the code sheet. 2.4 Ok. 2.5 See plan and door schedule for changed note regarding the door and corridor. The existing walls between the new space and the corridor are one hour. 3. Provide engineer stamped electrical plans and mechanical plans, provide a ComCheck compliance certificate for lighting. See sheet EI for engineer stamp. See attached Mechanical and Plumbing sheets. 3.1 See attached Mechanical plans. 3.2 See attached Plumbing plans. 3.3 See attached Comfheck. 4. Provide a listed one hour roof/ ceiling or floor/ ceiling assembly above this space. If the membrane is part of the assembly, provide method of maintaining rating at the new lighting fixtures and mechanical penetrations. See sheet A300. 5. The reflected ceiling plan indicates the ceiling height at 1'-2" and 6'-10". The code minimum is 1'-6" please change accordingly. Ok, see sheet A104 for new ceiling heights. 6. What is the reason for a two hour wall between spaces? Is it a new wall? The UL design referenced requires the drywall to be proprietary; it is to be type "c" drywall not the typical type "x". Provide opening protection for the new door per IBC 115.3. The two hour wall between spaces is an existing wall. See sheet A300 for two hour wall detail with type "c" drywall. See door schedule on sheet A400 for opening protection. 1. The drawings are indicating two new doors, one is 20 min and one is glass French. Sheet A20 indicates the glass french door leads to a common corridor. Please verify if the corridor is rated. (See checklist for egress plan and location identification within the overall building) (IBC 1016) The common corridor is rated, see Code Plan sheet A001. See attached drawing for location in overall building. 1.1 See door schedule and plan for note regarding 20 min rated door, (no longer a French door). 8. The plans indicate to add a return louver over new door I/101. If this is a rated corridor, the louver will require a smoke damper. (IBC 1016, 116.5.4.1) I have changed the louver to be completely in the new office space and not at all in the rated corridor or wall, see Proposed RCP sheet A104. 9. There appear to be glass adjacent to door I/101. If the corridor accessed by the new door is rated the glass will be required to be 45 min. (IBC table 115.4) The door (1/102) will be 20 min rated. Door I/101 will be a reused 20 min door. 10. The electrical drawing indicates that power and lighting to meet IRC. This code does not apply to this project. This will be addressed by the electrical engineer. I have changed my note to reference the IBC, see electrical drawings. }10 WEST LIONSNEAD CIRCLE, SUITE A VAIL COLORADO 81651 910.411.2990 910.411.29651F) www.khwebb.com MEMBER OF THE dMERICA~Y INST)TUTf Of ARCHITECTS . ct3.29.2008 11 ~ 49AM N0. 161 P.1i3 Department of~Community De-~/opmenf Bu!/d/ng Safety and Inspec~bn Sert~lces 755ou1fi l~rnn~ge Road I/ail, Co%rado X1657 970.479-2138 I FAX 970179-Z+~SZ MnNw. vai/gov.c~m This is the second original oo~nment. TO: correction letter; please respond to the bold comment following the Contractor/Applicant T. Hom Enterprises FAX/Email~#: thorn@centrytel.net NUMBER PAGES: FROM: DATE: BUILDING PERMlI' #': OWNERS AME: SITE ADD ESS: OCCUPAN GROUP: TYPE OF CONSTRUCTION: NUMBER OAF STORIES: BUILDING (AREA: Archite K.H. Webb proj# space (970)477-2965 3 John Plano, Building Plans Examiner 02/Z9/z008 608-0001 Vail Spa Office 710 W. Lionshead Circle Unit A s IIA unknown unknown The docume is submitted for this project have been reviewed for compliance with the 2003 Intemationa Building Code, 2003 Intemational Residential Code, 2003 International Mechanical Code, 2003 i`ntemational Fuel Gas Code, 2003 International Plumbing Code, 2003 Intemational Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. Tfie For/ • • • c»ntments wi//need to be addressed prior In issaanae of a bui/ding permit; Please be sure to include on the resubmittal the engineer's or architect's "wet" stamu, sianature_ , registration number and date on the cover pane of any structural calculations, all structural details and structural sheets of the plans For commercial or multi-family oroiects all sheets of the plans must be stamped. FEB.29.2008 11~49AM ~ ~~ • Architectural Commentst 1 Please refer to the "Building Department Checklist fvr Commerdal Tenant Finish/Improvement" for information required to be induded to proceed with further review of this project. Provide all items on the list. z Provide an egress plan. From the tenant space to exit discharge. (IBC Chapter 10) 2.1 The Vail Spa Level Plan is not legible enough to determine what the uses are of the spaces. Please provide legible plans indicating ocwpancy classification of surrounding rooms and clearly show exit path to exit discharge. 2.2 Exit discharge is the means of egress system between the termination of an exit and the public way. The egress plan indicates a double door at the top of the page as exit discharge, this does not appear do be outside the building. (IBC 1002.1) 2.3 The door at the end of what is labeled as exit wrridor appears to enter a parking garage, this does not constitute exit discharge. Exiting through a parking garage is not permitted. (IBC 1013.2) Z.4 Remove the exit sign from above 1/101. Door 1/102 appears to be the only legitimate e~dt door. The occupant load and travel distance in this space will indicate the need for one exit. See comment 2.1. (IBC 1014.1) 2.5 The corridor accessed from door 1/102 appears to be a rated corridor as it serves residential occupancies. Add the one hour wall type to the drawings and change door 1/102 to a 20 minute door. (YBC 1016.1) 3 Provide engineer stamped electrical plans and mechanical plans, provide a ComCheck compliance certificate for lighting. (see checklist) 3.1 Provide complete engineer stamped mechanical plans, demolition and new construction. These plans are also to include location of all fire dampers and smoke dampers where applicable. Please include the ventilation rates at each lower. 3.2 Provide engineer stamped plumbing demo plans. Yndicate if any existing pipes in the space that have to stays to serve as vents for fixtures below. Provide fire-stop details to patd~ the holes in the floor. (IBC 712) 3.3 Provide the (mechanical and electrical ComChedc report for verification with the energy code. (IBC Chapter 13) 7 The drawings are indicting two new doors, one is 20 minute and one Is glass French. Sheet AZO indiptes the glass French door leads to a common corridor. Please verify if the corridor is rated. (see d~eckllst for egress plan and location Identification within the overall building) (IBC 1016) 7.1 The "French door" 1/102 is to be rated to ZO minute. See comment 2.5. (IBC 715.3) 9 There appear to be glass adjacent to door 1/101. If the comdor, accessed by the new door, is rated the glass will be required to be 45 minute. (IBC Table 715.4) The response is referencing door 1/102. The comment indicates door 1/101, which is shown as 20 minute. Based on the existing floor plans supplied it appears that the corridor marked as Exit Corridor does not Aeed to be rated. This will be confirmed with the legible existing plans requested irr comment 2.i. FEB.29.2008 11~49AM please refer to 1fie cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check all requested information is inducted with the resubmitted plans. please submit revised plans as a complete set Partial plan resubmittals will not be reviewed. John Plano I.C.C. Plans F~caminer Town of Vail Ouilding Safety and Inspection Services 970.479.2140 folanoC~vailaov.com BUILDING PERMIT APPLICATION CHECKLIST COMMERCIAL TENANT FINISH/IMPROVEMENT This checklist is to be used with any tenant finish/improvement permit application. Town of Vail Design Review Board approval must first be obtained for any exterior modifications proposed N~Pc Plan Check Fee must be paid at the time of application for projects over $100,000 valuation (see attached schedule) The following information must be shown on all 4 sets of plans: Construction plans stamped and signed by a Colorado State Licensed Architect. Original building construction type per IBC chapter 6 ex. II-A, V-B Tenant suite or tenant space number. Tenant space location identification. Show location of the tenant space within the overall building. Floor plans with existing and proposed walls. Show all wall assembly construction and proposed interior finishes with flamespread index. Proposed construction type must match existing building construction type. Clearly show proposed use of each room or space on the plans. Reflected ceiling and finish plan. Type of materials must match the fire resistance/type of construction requirements in the existing building. Show all interior ceiling finishes and flamespread index Door schedule. All doors shall be clearly identified with fire rating, size, hardware and swing. Means of egress plan. Show all occupant loads and number of exits from the tenant space Areas requiring two (2) exits: Exit doors shown to swing in the direction of exit travel, separation of exits comply with code, illuminated exit signs are shown. Windows shall be labeled with size, operation, safety glass. All areas and rooms of the tenant space are accessible per ANSI 117.1 requirements. Accessible maneuvering clearances provided at all doors for accessibility per ANSI 117.1 Service counter-tops and built-in work stations provided with accessible areas per ANSI 117.1 Bathroom facilities. All accessible/adaptable features, clearances and turning spaces provided per ANSI 117.1 requirements must be shown. t, `~ Separate sex bathroom facilities provided if the number of occupants or employees exceeds (15). N~T+ Toilet room floorslwalls finish schedule. N~/~ ^ Floors have a smooth, hard, nonabsorbent surface such as concrete, ceramic the or other approved material, extending upward onto the walls at least 5". ^ Walls within 2 feet of the front and sides of urinals and water closets must have a smooth, hard nonabsorbent surface to a height of 4 feet. Occupancy separations for walls/ceilings between tenants clearly shown on the plans with fire resistive construction details and listings specified. Fire-stopping. Fire-stopping penetration details for plumbing, mechanical and electrical components in all fire rated walls and ceilings. Plumbing, Electrical and Mechanical Plans stamped by a Colorado State Licensed Engineer Mechanical HVAC plans, plumbing plans, electrical plans/panel schedules/load calculations. Fire/smoke Dampers on mechanical plans at all duct penetrations into fire resistive walls and ceilings. Fire sprinkler plans. Show all proposed work per Vail Fire and Emergency Services requirements Fire alarm plans. Show all proposed work per Vail Fire and Emergency Services requirements I have read and understand the requirements of this checklist. If any required information is missing from the application, l understand the application will not be accepted. ~~~ 3 Applicant's Signature Date http://www.vailgov.com/dots/dl_forms/building~ermit_4-17-2007. DOC b~ Page 3 of 7 04/17/2007 • • ~s~ s~mw Aw Vk:Pws c-' ?YiWN(1FVA1I. 75 south Frontage Road I/ail, Co%rado 81657 970-479-2138 FAX 970-479-2452 www. vailgov.com Department of Community Deve%pment Building safety and Inspection Services ?~ ~~ } ~ ~¢~ BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS: TO: Contractor/Applicant T. Horn Enterprises FAX/Email #: thorn@centrytel.net NUMBER OF PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME: SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: Architect K.H. Webb proj# space (970)477-2965 3 John Plano, Building Plans Examiner 01/17/2007 B08-0001 Vail Spa Office 710 W. Lionshead Circle Unit A B IIA unknown unknown The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 International Mechanical Code, 2003 International Fuel Gas Code, 2003 International Plumbing Code, 2003 International Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. The fo/%wing comments wi//need to be addressed prior in issuance ofa but/ding permit: For processing: • Please submit four complete sets of revised construction documents containing the reauested information with all plan revision items clouded or otherwise identified. • Please respond in writing to each comment bx marking the attached list or creating a response letter Indicate which~lan sheet detail specification or calculation shows the reauested information Please send revisions to the attention of the plans examiner with the buildma permit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's'~wet" stamp, signature, registration number and date on the cover page of any structural calculations, all structural details and structural sheets of the,~lans For commercial or multi-family protects all sheets of the plans must be stamped. Architectural Comments: 1 Please refer to the "Building Department Checklist for Commercial Tenant Finish/Improvement" for information required to be included to proceed with further review of this project. 2 Provide an egress plan. From the tenant space to exit discharge. (IBC Chapter 10) 3 Provide engineer stamped electrical plans and mechanical plans, provide a ComCheck compliance certificate for lighting. (see checklist) 4 Provide a listed one hour roof/ceiling or floor/ceiling assembly above this space. If the membrane is part of the assembly, provide method of maintaining rating at the new light fixtures and mechanical penetrations.(Table 601) 5 The reflected ceiling plan indicates the ceiling height at 7' 2" and 6' 10". The code minimum is 7' 6". Please change accordingly. (IBC 1208.2) 6 What is the reason fora 2 hour wall between spaces. Is it a new wall? The UL design referenced re uires the d all to be ro rieta it is to be a "C" d all not the ical a "X". Provide q MN P P rY; tYP ~ tYP tYP opening protection for the new door per IBC 715.3. 7 The drawings are indicting two new doors, one is 20 minute and one is glass French. Sheet A20 indicates the glass French door leads to a common corridor. Please verify if the corridor is rated. (see checklist for egress plan and location identification within the overall building) (IBC 1016) 8 The plans indicate to add a return louver over new door 1/101. If this is a rated corridor, the louver will require a smoke damper. (IBC 1016, 716.5.4.1) 9 There appear to be glass adjacent to door 1/101. If the corridor accessed by the new door is rated the glass will be required to be 45 minute. (IBC Table 715.4) 10 The electrical drawing indicates that power and lighting to meet IRC. This code does not apply to this project. This will be addressed by the electrical engineer. (see checklist, 2005 NEC) Please refer to the cover sheet for information on resubmitting plans. In order to avoid delays in issuance of a permit, please check ~ requested information is included with the resubmitted plans. Please submit revised plans as a complete set. Partial plan resubmittals will not be reviewed. John Plano I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.479.2140 jplano@vailgov.com F•\cdev\CHRIS\PERMIT COMMENTS\608-0001\B08-000I.DOC 3~N{)FViI~ . BUILDING PERMIT APPLICATION CHECKLIST COMMERCIAL TENANT FINISH/IMPROVEMENT This checklist is to be used with any tenant finish/improvement permit application. ^ Town of Vail Design Review Board approval must first be obtained for any exterior modifications proposed ^ Plan Check Fee must be paid. at the time of application for projects over $100,000 valuation (see attached schedule) The following information must be shown on all 4 sets of plans: ^ Construction plans stamped and signed by a Colorado State Licensed Architect. ^ Original building construction type per IBC chapter 6 ex. II-A, V-B ^ Tenant suite or tenant space number. ^ Tenant space location identification. Show location of the tenant space within the overall building. ^ Floor plans with existing and proposed walls. Show all wall assembly construction and proposed interior finishes with flamespread index. Proposed construction type must match existing building construction type. Clearly show proposed use of each room or space on the plans. ^ Reflected ceiling and finish plan. Type of materials must match the fire resistance/type of construction requirements in the existing building. Show all interior ceiling finishes and flamespread index ^ Door schedule. All doors shall be clearly identified with fire rating, size, hardware and swing. ^ Means of egress plan. Show all occupant loads and number of exits from the tenant space ^ Areas requiring two (2) exits: Exit doors shown to swing in the direction of exit travel, separation of exits comply with code, illuminated exit signs are shown. ^ Windows shall be labeled with size, operation, safety glass. ^ All areas and rooms of the tenant space are accessible per ANSI 117.1 requirements. ^ Accessible maneuvering clearances provided at all doors for accessibility per ANSI 117.1 ^ Service counter-tops and built-in work stations provided with accessible areas per ANSI 117.1 ^ Bathroom facilities. All accessible/adaptable features, clearances and turning spaces provided per ANSI 117.1 requirements must be shown. ^ Separate sex bathroom facilities provided if the number of occupants or employees exceeds (15). ^ Toilet room floorslwalls finish schedule. ^ Floors have a smooth, hard, nonabsorbent surface such as concrete, ceramic the or other approved material, extending upward onto the walls at least 5". ^ Walls within 2 feet of the front and sides of urinals and water closets must have a smooth, hard nonabsorbent surface to a height of 4 feet. ^ Occupancy separations for walls/ceilings between tenants clearly shown on the plans with fire resistive construction details and listings specified. ^ Fire-stopping. Fire-stopping penetration details for plumbing, mechanical and electrical components in all fire rated walls and ceilings. ^ Plumbing, Electrical and Mechanical Plans stamped by a Colorado State Licensed Engineer Mechanical HVAC plans, plumbing plans, electrical plans/panel schedules/load calculations. ^ Fire/smoke Dampers on mechanical plans at all duct penetrations into fire resistive walls and ceilings. ^ Fire sprinkler plans. Show all proposed work per Vail Fire and Emergency Services requirements ^ Fire alarm plans. Show all proposed work per Vail Fire and Emergency Services requirements I have read and understand the requirements of this checklist. If any required information is missing from the application, I understand the application will not be accepted. Applicant's Signature Date P. 1 FILE MODE 133 MEMORY TX * ~ ~ C~UNICATION RESULT REPORT ( JAN.17~8 6~24PM ) ~ ~ ~ TTI OPTION ADDRESS (GROUP) RESULT PAGE ----------------- -------------------------9~772'?65 ----------- OK P. 3i3 REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO ANSWER E-2) BUSY E-4) NO FACSIMILE CONNECTION Department of Community Development 8ulld/ng Safety and Insp~e[#lon Services 75 South Frontage Road Vail, Colorado 81657 970479-21.38 FAX 970-479-Z4S7 1NFYW. vailgOV. COnl BUILDING SAFETY AND INSPECTION SERVICES PLAN REVIEW COMMENTS Tp; Contractor/Ap.Plicant T, Harn Enterprises FAX/E~nait #: thorn@centrytel,net NUMBER QF PAGES: PROM: DATE: ~ BUILDING PE~tMIT #: a OWNERS NAME: ~ SITE ADDRESS: OCCUPANCY GROIIp: rc itect K.H. Webb proj# space (970)477-2965 3 John Plano, Building Plans Examiner 01/17/2007 sas-oooi Vail Spa OfFice 710 W. Lionshead Circle Unit A R • 01.23.oa BUILDING SAFETI AND INSPECTION SERYKES PUN REVIEW tOMMENTS- REPIY: C~ T0: John Plano. Bolding Plans Exarniner FROM: KTIe Webb & Lauren Ford. K. N. Webb Architects 970.417.2990 Building Permit #: BOB-0001 OWNERS NAME: Val Spa OFfice SITE ADDRESS: 710 West Lionshead Circle Unit A ODUPANtY GROUP: B TYPE OF CONSTRUCTION: IIA Architectural tommenu: I. Please refer to tk "Building Dept Checklist For Commercial Tenant FinislJ Improranent" For intornntiop requrced to Ix inducted to proceed with further reviex of this project Ok. 2. Provide an egreu plan. From the tenant spas to disdlarge. (IBC dsapter IQ) See Code plan sheet A001. 3. Proride engineer stamped electrical plans and mechanical plans, provide a Comthedc canpfi:flce certlhnte for fightmg. See sheet E I for engineer stamp. Mechanical engineer to verify balance of air changes prior to occupanry. 4. Provide a listed one hour roof! ceiling or Door/ ceiling assembh above this spas. N the membrane is part of the asseroby, provide method of maintaining raring at the new fighting bxtures and mechanical penetraturus. See sheet A300. 5. The reflected ailing plan ~dirates the sling height at l'-2" and 6'-10". the code minimuns is T-6" please change accordin~y. Ole, see sheet A104 for new ceiling heights. 6. What is the reason For a two hour waU between spaces? Is it a new waU? The UL dessgn referenced rtquira the dryw>d to be proprietary; it is to be type "c" dryvraU not the typ'ial type "x". Provide opening protection For the new door per IBC 715.3. The two hour wall between spaces is an existing wall; it is no longer required to be rated. See sheet A300 for two hour wall detail with type "i' drywall. See door schedule on sheet A400 for opening protection. 7. The drawings are iad'scating two new doors. one is 20 min and one is glass french. Sheet A20 iod~icates the glass French ~ _ leads to a common corridor. Please verify i( the corridor is rated. (See checklist for egress plan and location identdication within the oreraN binding) (IBC 1016) The common corridor is not rated, see Code Plan sheet A001. See attached drawing for location in overall building. B. The phns indiate ro add a return buyer over new door I/141. K this is a rated wrridor, the lower wiB require a smola• damper. (Iflt 1016,116.5.4.1) I have changed the louver to be completely in the new office space and not at all in the rated corridor or wall, see Proposed RCP sheet A104. ~ 9, There appear to b! glass adjacent tO door 1!101. If the corridor accessed br the new door a rated the glass w~ b! reganTed to be 4S min. (IBC table 115.4) The glass French door (U102j leads to a non rated corridor. ~ 10. The electrial drawing ind'rates that pourer and fighting to meet tRC This code does not applf to tha project. This wi be addressed by the electrical engineer. (see checklist, 2005 NEC1 I have changed my note to reference the IBt, see electrical drawings. a, 110 .'ZEST EIE~tISHEk© CIRttE, 9TO.a11.2940 RTQ.aJT. SUITE A YA1t f{ILGR~DO 81651 294SfE~ rrr kirtii ta, JAN. 17.2008 6~23PM ,, . ' U f~ C~ IT A,PPL,ICATION CHE N0.133 This checklist is to be used with any tenant finishlimprovement permit application. [. Town of Vail Design Review Board approval must first be obtained for any exterior modifications proposed u Plan Check Fee must be paid at the time of application for projects over $100,000 valuation (see attached schedule) The following information must be shown on all 4 sets of plans: ~ Construction plans stamped and signed by a Colorado State Licensed Architect. u Original building construction type per IBC chapter 6 ex. II-A, V-B u Tenant suite or tenant space number. u Tenant space~location identification. Show location of the tenant space within the overall building. f1 Floor plans With existing and proposed walls. Show all wall assembly construction and proposed interior finishes with flamespread index_ Proposed construction type must match existing building construction type. Clearly show proposed use of each room or space on the plans. [ ~ Reflected ceiling and finish plan. Type of materials must match the fire resistance/type of construction requirements in the existing building. Show all interior ceiling finishes and flamespread index n Door schedule. All doors shall be clearly identified with fire rating, size, hardware and swing. fJ Means of egress plan. Show all occupant loads and number of exits from the tenant space u Areas requiring two (2) exits: Exit doors shown to swing in the direction of exit travel. separation of exits comply with code, illuminated exit signs are shown. u Windows shall be labeled with size, operation, safety glass. ~ All areas and rooms of the tenant space are accessible per ANSI 117.1 requirements, ~ Accessible maneuvering clearances provided at all doors for accessibility per ANSI 117.1 [~ Service countertops and built-in work stations provided with accessible areas per ANSI 117.1 [7 Bathroom facilities. All accessible/edaptablefoatures, dearances and turning spaces provided per ANSI 117.1 requirements must be shown. ~ Separate sex bathroom facilitiies provided if the number of occupants or employees exceeds (15). u Toilet room floorshnralls finish schedule. u Floors have a smooth, hard, nonabsorbent surface such as concrete, ceramio file or other approved material, extending upward onto the walls at least 5". u Walls within 2 feet of the front and sides of urinals and water dosets must have s smooth, hard nonabsorbent surface to a height of 4 feet. f' Occupancy separations for walls/ceilings between tenants clearly shown on the plans with fire resistive construction details and listings specified. I~ Fire~topping, Fire-stopping pen®tratfon details for plumbing, mechanical and electrical components in all fire rated walls and ceilings. ;~~ Plumbing, Electrical and Mechanical Plans stamped by a Colorado State Licensed Engineer Mechanical HVAC plans, plumbing plans, elect ' tans/ anel u d cula ' i.~ Fire/smoke Dampers on mechanical plan at all duct penetrations into fire resistive walls and ceilings. n Fire sprinkler plans. Show all proposed work per Vail Fire and Emergency Services requirements u Fire alarm plans. Show all proposed work per Vail Flre and Emergency Services requiremerts I have read and understand the requirements of this checklist. ff any required information is missing from the application, I understand the application will not be accepted. Applicant's Signature Date JAN. 17.2008 6~23PM ,~ ' ,. • N0.133 P.1i3 Depaib»ent of Community Development Bulld/ng Safety and Insp~ec~ion SeiYices 75South Fronbge Road I/ail, Colorado 81657 9701179 2138 PAX 970-479-Z45,Z www. vailgovcom BUILDING SAFETY AND INSPECTION 5ERVICES PLAN R.EVIIIe1M COMMENTS TO: Contractor/Applicant T. Horn Enterprises FAX/E~ttail #: thorn@centrytel.net NUMBER OP PAGES: FROM: DATE: BUILDING PERMIT #: OWNERS NAME; SITE ADDRESS: OCCUPANCY GROUP: TYPE OF CONSTRUCTION: NUMBER OF STORIES: BUILDING AREA: itect K.H. Webb proj# space (970)477-2965 3 John Plano, Building Plans Examiner 01/17/2007 608-0001 Vail Spa C+fFice 710 W. laonshead Circle Unit A B IIA unknown unknown The documents submitted for this project have been reviewed for compliance with the 2003 International Building Code, 2003 International Residential Code, 2003 Internataonai Mechanical Code, 2003 International Fuel Gas Code, 2003 Yntemational Plumbing Code, 2003 International Energy Conservation Code and 2005 National Electrical Code as modified and adopted by the Town of Vail. 7-'he fo/%wing comn-ent~ will need to be addriesaed prior M issuance of a bui/ding p~en»k: For processing: • Please submit four com.~lete sets of revised construction documents containing the n'tauested information with all plan revision items clouded or otherwise identified. • Jease respond in writing to each comment by marking the attached list or creatin4 a response Letter Indicate which plan sheet, detail, specification, or calculati n shows the requested information Please send revisions bo the attenfion of the plans examiner with the building permit application number noted. • Please be sure to include on the resubmittal the engineer's or architect's "wet" stamp, sianatur_e, registration number and date on the cover pace of anv structural calculations, all structural Mails and structural sheets of the olans. For commercial or multi-family projects all sheets of the plans must be stamped. JAN. 17.2008 6~23PM ~' '_• e~l~itectural Comments: 1 Please refer to the Building bepartment Checklist for Commercial Tenant Fnish/Improvement" for information required to be included to proceed with further review of this project. 2 Provide an egress plan. From the tenant space to exit discharge. (IBC Chapter 10) 3 .Provide engineer stamped electrical plans and mechanlcal plans, provide a ComCheck compliance certificate for lighting. (see checklist) 4 Provide a listed one hour roof/ceiling or floor/ceiling assembly above this space. If the membrane is part of the assembly, provide method of maintaining rating at the new light fixtures and mechanical penetrations.(Table 601) 5 The reflected ceiling plan indicates the ceiling height at 7' 2"and 6' 10". The code minimum is 7' 6". Please change accordingl~C. (IBC 1208.2) 6 What is the reason fora 2 hour wall between spaces. Is it a new wall? The UL design`referenced requires the drywall to be proprietary; it is to be type "C"drywall not the typical type X . Pr vide opening protection for the new door per IBC 715.3. 7 The drawings are indicting two new doors, one is 20 minute and one is glass French. Sheet A20 indicates the glass French door leads tQ a common corridor. Please verify if the corridor is rated. (see checklist for egress plan and location identification within the overall building) (IBC 1016) 8 The plans indicate to add a return louver over new door 1/101. If this is a rated corridor, the louver will require a smoke damper. (IBC 1016, 716.5.4.1) 9 There appear to be glass adjacent to door i/101. If the corridor accessed by the new door is rated the glass will be required to be 45 minute. (IBC Table 715.4) 10 The electrical dra}+ving indicates that power and lighting to meet IRC. This code does not apply to this project. This will be addressed by the electrical engineer. (see checklist, 2005 NEC) Please refer to the cover sheet for information on resubmitting plans. In order m avoid delays in issuance of a permi#, please check ~1_ requested information is induded with the resubmitted plans. Please submit revised plans as a complete set. Partlial plan resubmlttals will not be reviewed. ]ohn Plano I.C.C. Plans Examiner Town of Vail Building Safety and Inspection Services 970.479.2140 jplano@vailgov.rnm ~1~.~ r u ~ r n oE~y~,~p MM ENTS\808-0001\608-0001. DOC 13" Material FF 109 Weight 1.5 lb Notes UL Classified: R25019 FF109 Fire Rated Recessed Light Cover L~,t,7rtinaire Assemblies Classified for. Fire Resistance Fire Rated Classification (see UL Fire Resistance Directory) Fixture 1limensions (IC-rated). Up to 6-7/8" diam. ceiling opening Up to Height- 7.5 everall or 6-7/8 not including the flange .down to sheetrock Up to Weight 3.8 Lb (housing only) For more info about the Fire Rating visit" www.ul.com (click on Certi ications and look. for Tenmat) Rev.. Date Drauring Ntrr . o , Os os ~~ ctae~ ~ anon R25o-9 FF 10~ UL dome Date. O, 03 OB Scale- None Kate FF,09 T8 KA !nc 3 BJ 6 0 Divia{on: Fire Protection PART Y FF 109 13 "x 8 " Light .Cover TENMAT ,...~ r ...n w- .ra rw...... ~. Page 1 of 1 Spring Hinge, UL Listed ~ Qb By Emtek Products, Inc. rc~ware ~~a Part # 2039956 Price $26.00 Size Options 3'/z" x 3'~" Corner Options '/." Radius Finish Options Oil Rubbed Bronze Dimensions Description Spring Hinge Available in several sizes, corner and finish options Plated Steel 0.098" Thick Price is per pair All hinges supplied with screws http;//www.knobsandhardware.com/printlprint.aspx7sku=2039956 11/27!2007 u COMcheck Software Version 3.5.3 Envelope Compliance Certificate 2003 IECC Town of Vail Report Date: 04/10/08 ®~~~ spy Data filename: Untitled.cck Section 1: Project Information Project Type: Addition Project Title :Vail Spa Remodel Construction Site: 710 W. Lionshead Circle Unit A Vail, CO 81657 Permit No. B08-0001 Permit Date: 03/2702008 Owner/Agent: Kyle Webb k h webb architects 710 W. Lionshead Circle Unit A Vail, CO 81657 970.477.2990 lauren@khwebb.com Section 2: General Information Building Location (for weather data): Vail, Colorado Climate Zone: 15 Heating Degree Days (base 65 degrees F): 9248 Cooling Degree Days (base 65 degrees F): 44 Activiri Tvoefsl Floor Area Office 718 Section 3: Requirements Checklist ;,..,, TOWN OF VAIL Designer/Contractor: Todd Hom Todd Hom Enterprises po box 552 Edwards, CO 81632 970.390.5111 Climate-Specific Requirements: Component Name/Description Gross Area Cavity or Perimeter R-Value Cont. R-Value Proposed U-Factor Budget U-Factor Roof 1: Non-Wood JoisURafter/Truss 718 38.0 0.0 0.036 0.045 Skylight 1: Metal Frame with Thermal Break:Single Pane, Clear, 4 -- -- 0.400 0.045 SHGC 0.98 Skylight 2: Metal Frame with Thermal Break:Single Pane, Clear, 4 -- -- 0.400 0.045 SHGC 0.98 Skylight 3: Metal Frame with Thermal Break:Single Pane, Clear, 4 -- -- 0.400 0.045 SHGC 0.98 Floor 1: Non-Wood Joist/Truss 718 26.0 0.0 0.042 0.040 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor-permeable wrapping material installed in accordance with the manufacturer's installation instructions. 2. Windows, doors, and skylights certified as meeting leakage requirements. ~3. Component R-values 8~ U-factors labeled as certified. /~4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. ~. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. 8 0 r1 Project Title: Vail Spa Remodel Report date: 04/10/08 Data filename: Untitled.cck Page 1 of 2 ` 6. Cargo doors and loading doors are weather sealed. ^f~7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air-tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. Building entrance doors have a vestibule and equipped with closing devices. Exceptions: Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq. ft. in area. ~9. Vapor retarder installed. S`e'ction 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is wnsistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck Version 3.5.3 and to comply with the mandatory requirements in the Requirements Checklist. Nam -Title Signa ure Date __. Project Title: Vait Spa Remodel Report date: 04/10/0 Data filename: Untitled.cck Page 2 of 2 TOWN OF VAIL FIRE DEPARTMET~ 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-2135 NOTE ALARM PERMIT Job Address: 710 W LIONSHEAD CR VAIL Location.....: 710 W. LIONSHEAD CR. UNIT'A' Parcel No...: 210106317056 Project No ~~~ S 6~ - voo3 OWNER WEBB, KYLE & LORAINNE 04/30/2008 ', PO BOX 2630 EDWQARDS CO 81632 APPLICANT SIMPLEX TIME RECORDER COMPAN 04/30/2008 6240 SMITH ROAD DENVER COLORADO 80216 License: 105-5 CONTRACTOR SIMPLEX TIME RECORDER COMPAN 04/30/2008 6240 SMITH ROAD DENVER COLORADO 80216 License: 105-5 Desciption: VAIL SPA OFFICE SPACE CONVERSION Valuation: $2,000.00 Permit #: A08-0035 ^$6 ~ - dab ~ Status ...: ISSUED Applied ..: 04/30/2008 Issued . .. 05/05/2008 Expires . .: 11/01/2008 Phone: (303) 355-0500 Phone: (303) 355-0500 #*##*#*###########*###*####*##**#######**##**#*#**##*#***##*####**#* FEE SUMMARY ****##*#####**##*###**######**######**#***#**#*#*###*##**##* Electrical-----> $ O. o o Total Calculated Fees--> $ 3 0 7. 0 0 DRB Fee---------> $ 0 . o o Additional Fees-________> $ o . 0 0 Investigation---> $ o. o o Total Permit Fee-------> $ 3 0 7. 0 0 Will Call--------> $ 0. 0 0 Payments------------------> $ 3 0 7. 0 0 TOTAL FEES-> $ 3 0 7. 0 0 BALANCE DUE-______> $ o. o 0 ############f## ############;###################f##################################################################i############################## Approvals: Item: 056 00 FIRE DEPARTMENT 05/ 01/2008 JGG Action: AP Approved per Lt. Mike Vaughan, earlier review. #################################################################################################################################f############### CONDITIONS OF APPROVAL ################################################################################################################################################# DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. ~ _.. .,. REQUESTS FOR INSPECTION SHALL BE MADE SEVENTY-TWO HOURS IN ADVA~QE BY T EPHOIVE AT 970-479 R61Gt 8:00 AM - 5 PM. VAIL FIRE DEPARTMENT • THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES SIGNA O OWN ~ ONTRACTOR FOR HIMSELF'~1D OWNER • • TOWN OF VAIL, COLORADO Statement ****~***********++*+**+*************+**~****~**+****+*******************+****~*~**********r* Statement Number: 8080000613 Amount: $307.00 05/05/200810:47 AM Payment Method: Check Init: LC Notation: #2790/T HORN ENTERPRISES INC. Permit No: A08-0035 Type: ALARM PERMIT Parcel No: 2101-063-1705-6 Site Address: 710 W LIONSHEAD CR VAIL Location: 710 W. LIONSHEAD CR. UNIT 'A' Total Fees: $307.00 This Payment: $307.00 Total ALL Pmts: $307.00 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts ----------------------- BP 00100003111100 FIRE ALARM PERMIT FEES 75.00 PF 00100003112300 PLAN CHECK FEES 232.00 MAY. 1.2008 10~15AM N0.223 P.1i2 ..~ APPLICATION 1MtLL NOT BE ACCEPTED ~F INCOMhL^ETEAO~Rr ..UµµNSxGNED ~ ~~ Praaect'It•i r Building Permit #: Dft'-QCIfS,~, Alarm Permit #• ~D?~2 ,~ ~l~N(~~AII~ ~ TOWN ~F VAII,~F~RE ALARM FERMTT AP_PI,~~A'[~4~ commeraat ~ Residential sire Alarm shop drawings are required at time of 75 S. l=rontage Rd. application submittal and must indude information listed on the Vail, Colorado 81657 Z page of this farm, Application will not be accepted without l:his infonaation. ~ ON c41VTRAC70R YNFORMAI'I t ~ ~ r Fire Alarm Contractor: own of Vail Reg. Nor: Cp~Jtact Person and Phone #'s: E-Mail Address: f-? f A~ i~~tA~ S ie~c rr+~ 11,e~,~~ Fax#: d~, .. SS .. ~~$' Contractor Signature: , ,~~~ COMPLI=T~ VALUATIONS FOR ALARM PERMIT {Labor & Materials) Flre Alarm: ~ Zr~aa _ wrr__ _: w~rf s.'f 6_bCdA wr .d../F u.umi n~n~aMl)/9f'1/ IIC FAY ~311I'A~ ~ 4VI/i.GW. LQ /Q .rVMIlfr I7,7r7cOr7ar~a yq/w •+- rr r . _ - _ _ _ _ _ _ _ parcel # c~l~I D6 ~ Zob Name: A1~ ~ . I ]ob Address; 7ia ~ L,o • M~~~ ~ ~ . Legal Description lot; Block: ~. Filing: Subdivision: ~~QY7lS~[~ Owners Nama: Address: Phone: i"ngineer: Address; Phone: Detailed vocation of work: (i.e., floor, unit #, bldg, #) ~~' ~~ ~ ,~rri~C s7 ~ U betailed description of work: ~G~' ,, - cr ~ S~okr~ ~c."TUL.r ~~~ r~~c-~~ (1 Nc,~e,U .S~~u~1c, Work Class: New () Addltlon ( ) Remodel ~}Cj: Repair ( ) Retro-fit ( ) Other ( ) Type of Bldg.: Slagle-family ( ) i'wo-family ( ) Mul#i-family ( ) Commercial ~ Restaurane ( )other ( ) No. of Exisgng Dwelling units in this building: Nor of Accommodation units in this building: Does a • ' farm Exist: Yes No ( ) Does a dire Sprinkler System Exist: Yes (~` No ( ) `' .--r~~ 'kkttAkt0i4rtMk+kR~tl!'~Ck:UYF~ _~~ S wne...._. ~, L Si~~i1e. oth~~ ~ ~ is W. .' ~: °~~- ~~~ ~ ONLYxxka~r~a~r:rx~;*~~*.t~~~+a,a**e~*~r+~,vu*~:e~~taae~r MAY. 1.208 10~15RM "" Frre & Security ~inip/exGrinn®!~ Vail Fire and Emergency Services Attu, Mike McGee 42 West Meadow Urive Vaal, COS 1657 Re: Vail Spa Webb TI 710 W Lionshead Cir Vail, CQ 81657 N0.223 P.2/2 SirnplezGllnllelf LP 6240 Smah RDad Dem~er, Co B02iB Main: 303,355-0500 fax 303~55-0Bi5 Oirsq; 303-2825719 !=-MaU, mfamirola~sknplexgrinneu.com Dear Mr. McGee, Due to the minor scope of work for the above referenced project, SimplexGrinnell has prepared this letter, per your approval, to obtain a Fire Alarm permit. The work will be done on the 2"d Floor in the new office space. The project consists of replacing 3 smoke detector heads and relocating one hornlstrobe to an adjacent wa1118' away. There are two smoke detectors located in the room labeled Office 100 and one detector located in Storage closet 100. No devices are being added or removed firom the existing system, therefore all battery calculations and voltage drops will remain the same. The sequence of operations for this building wi11 also remain the same. Attached with this letter is a Permit Application, if there is any other information needed or if you have ariy questions, please contact me. Respectfully, ,Il~ihe Larnital~ project Manager SimplexGrinnell-Denver District 414 Office; 303.355.0500 Mobile:303.961.2556 ~~~.TM~~~ mlamitola~a7simplexgTinnelI.co p~ ~.~rr.. ~~ ~ ~,o---tt~~ ~~© ~~-~ --"" gy' `~ s ~ ~~_____ TtUe: Date: -,-~- information. ~ ` ~ CONTRACTORS FORMATION Fire Alarm Contractor: awn o~Vail Reg. No.: Contact Person and Phone #'s: . ~ ~ `~ /-~i c ~~ iYV - .303- 6Z-S7i9 E-Mail Address: /i'1 LAnn iTvi~®S, iex c ~,~+„e lI. c ~~~ Fax#: ~; .. 'j S~ .- (/5 Contractor Signature: ._..,•:,~:-~~ , ~-' J , ~` APPLICATION WILL NOT BE ACCEPTED IF INCOMPLETE OR UNSIGNED _ pao3 Project #: Building Permit #: '~ Alarm Permit #: ~'OWNOFVA~ ~ TOWN OF VAIL FIRE ALARM PERMIT APPLICATION Commercial & Residential Fire Alarm shop drawings are required at time of 75 S. Frontage Rd. application submittal and must include information listed on the Vail, Colorado 81657 2" page of this form. Application will not be accepted without this COMPLETE VALUATIONS FOR ALARM PERMIT (Labor & Materials} f r'.~5.~ ~(~7 v~- Fire Alarm: $ L~~f} ~~ t 970-328-8640 or visit ww ea /ecoun . us for Parcel # Contact Ea /e Counf Assessors Office a Parcel # a ~ p~ O ~ Job Name: I ~~ - i? ~l Job Address: y , p /~ 7j U t~~/ G i~n1' rf~-11a ~-^ ~ it'. . . tr i< Legal Description Lot: Block: 2. Filing: Subdivision: ~ L~C11'15 Owners Name: Address: Phone: ~ Engineer: ~ Address: ~ Phone: Detailed Location of work: (i.e., floor, unit #, bldg. #) ~~ ~v )lfi~C °R~~~. mU Detailed description of work:; / ~ Work Class: New (} Addition { } Remodel ~- p ( ) ( Other ( ) Re air Retro-fiC ) Type of Bldg.: Single-family ( ) Two-family { ) Multi-family ( ) Commercial ~'' Restaurant ( )Other ( ) No. of Existing Dwelling Units in this building: No. of Accommodation units in this building: Does a Fire Alarm Exist: Yes No ( ) Does a Fire Sprinkler System Exist: Yes (~' No { ) ,~ 3 FOR OFFICE USE ONLY**************k~~***~**~*****``~'"'"**~:'" ,a**~ ~t,v~r*** x,e*~,~*~r~~:****x*~e*~**~~~e~e~z***,u ~ ~ , r ``..// ~ r ii ~~ ~~~ Other Fees' Date Received: '-~' `~ ~ ' ~ i i' ~. V" ~' Public Wa ~ Permit Fee: Acce ted B ~ l~~ Occu arty Group: ~i I' ~ i ~~ ~ ~~ u~ F:\cdev\FORMS\PERMITS\Fire\alarm_perm 12-OS-05.doc Page 1 of 4 ~__ _ ~~.~~ ~V ~~~/N ~- _ ; -rt o ~ Fire & Security Situp/ex6rinne// Vail Fire and Emergency Services Attn: Mike McGee 42 West Meadow Drive Vail, CO 81657 Re: Vail Spa Webb TI 710 W Lionshead Cir Vail, CO 81657 • SimplexGrinneU lP 6240 Smith Road Denver, CO ao21s Main: 303-355-0500 Fax: 303-355-0615 Direct: 303-262-5719 E-Mail: mlamitola@simplexgrinnell.com Dear Mr. McGee, Due to the minor scope of work for the above referenced project, SimplexGrinnell has prepared this letter, per your approval, to obtain a Fire Alarm permit. The work will be done on the 2nd Floor in the new office space. The project consists of replacing 3 smoke detector heads and relocating one horn strobe to an adjacent wall 18' away. There aze two smoke detectors located in the room labeled Office 100 and one detector located in Storage closet 100. No devices aze being added or removed from the existing system, therefore all battery calculations and voltage drops will remain the same. The sequence of operations for this building will also remain the same. Attached with this letter is a Permit Application, if there is any other information needed or if you have any questions, please contact me. Respectfully, Mike Lamitola Project Manager SimplexGrinnell-Denver District 419 Office: 303.355.0500 Mobile:303.961.2556 mlamitola@simplexgrinnell.com TOWN OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 8 NOTE ~ARTMENT OF COMMUNITY DEVEL~MENT THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES ELECTRICAL PERMIT Job Address: 710 W LIONSHEAD CR VAIL Location.....: 710 W. LIONSHEAD CR. UNIT'A' Parcel No...: 210106317056 Legal Description: ~ ~~~ -0063 Project No OWNER WEBB, KYLE & LORAINNE PO BOX 2630 EDWQARDS CO 81632 APPLICANT MD MOLLER CO PO BOX 1508 EDWARDS CO 81632 License: 355-E CONTRACTOR MD MOLLER CO PO BOX 1508 EDWARDS CO 81632 License: 355-E 03/28/2008 Permit #: E08-0044 ~ -O d0` Status . ..: ISSUED Applied ..: 03/28/2008 Issued . .: 03/31/2008 Expires . .: 09/27/2008 03/28/2008 Phone: (970) 569-3913 03/28/2008 Phone: (970) 569-3913 Desciption: VAIL SPA OFFICE SPACE CONVERSION- electrical permit Valuation: $10,000.00 Square feet: 2000 ################################################################### FEE Electrical-------> $ 218.5 o Investigation----> $ o. 0 0 Will Call------> $ 4 . 0 0 TOTAL FEES--> $ 2 2 2. 5 0 SUMMARY ############### Total Calculated Fees--> Additional Fees---------> Total Permit Fee--------> Payments-----------------> ####################################+######## $ 2 z 2.5 0 $ o. o 0 $ 2 2 2 .5 0 $ 2 2 2. 5 0 BALANCE DUE--------> $o . 00 ##################f################4########################################+k##################### #########;##################################### Approvals: Item: 06000 ELECTRICAL DEPARTMENT 03/28/2008 SHAHN Action: AP Item: 05600 FIRE DEPARTMENT ######################################################################i#########################i################################################ CONDITIONS OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. ###########i#####################################+F#######################-##########i#####-###################################################### DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN u BY TELEPbIONE AT 479-2 ] 49 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER • TOWN OF VAIL, COLORADO Statement Statement Number: 8080000365 Amount: $222.50 03/31/200811:37 AM Payment Method: Check Init: DDG Notation: MD Moller Company 8077 Permit No: E08-0044 Type: ELECTRICAL PERMIT Parcel No: 2101-063-1705-6 Site Address: 710 W LIONSHEAD CR VAIL Location: 710 W. LIONSHEAD CR. UNIT 'A' Total Fees: $222.50 This Payment: $222.50 Total ALL Pmts: $222.50 Balance: $0.00 ACCOUNT ITEM LIST: Account Code Description Current Pmts ----------------------- EP 00100003111100 ELECTRICAL PERMIT FEES 218.50 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 (I M (~ ~ FROM ~ ~ - 1+ c ~ ~ APPLI ON ~L~NbT~e• CI TOWN OF VAIt_. ~~~~ 75 S. Frontage Rd. Vail, Colorado 81657 t3 2008 0 ' 12/ST. 7:11 P0~ ~ J D IF INCOMPLETE OR UN E , O Project #: Building Permit #: Electrical Permit #:~08 -Oo4 N ~ `~ ~ 970-479-2149 (Inspections) Electrical Contractor: Town GVail Reg~No.: Contact Person Phone #'s: ! i~~~ E-Mail Address: ` 1 ~ , (Fax#: l~ Contractor Si re• COMPLETE SQ. FOOTAGE FOR AREA OF WORK AND VALUATION OF WORK (Labor & Materials) AMOUNT OF SQ FT IN STRUCTURE: ~ ~~~~ ELECTRICAL VALUATION: $ _r_ ..~,~...,.•.~ ~inr Ogre/ ~ Contact Ea /e Coun .4ssessers ofiyc~e ar9iu-sca-av~.v ~, .•..~.~ ~...•• ~~ .~ ~ -- - -- - Parcel # ~ ~Q ~ ~ ~h ~ l : ~i ~ ~ Add Job Name: o ~ ~~ 1L~ - ress Job Legal Descripfpon Lot: Block: Filing: Subdivision: " Owners Name:' ,~ Ad ness• -1lQ 1 0~ Phane . Address: Engineer: Phone: Detailed description of work:() ~ 10~ n ~ ~~ Work Class: New () Addition ( ) Remodel ( ) Repair ( ) Temp Power ( ) Other ( ) Work Type: Interior ( F~cterlor ( ) Both ( ) Does an EHU exist at this location: Yes ( ) No ( ) Type of Bldg.: Single-family ( ) Duplex ( ) Multi-family ( ) Commercial ) Restaurant ( )Other ( ) No. of Existing Dwellir~ Units in this building: No. of Accommodation Units in this building: Is this ermit for a hot tub: Yes No No ( ) Y Does a Fire Sprinkler System Exist: Yes No ( ) es Does a Fire Alarm Exist: *tt**aw,ww*ww,r+r*r~w,-**~+~+-.*+++**+i*ww+rt+*FOR OFFICE USE ONLY'"`~*'"wwwrw«*w+rw~w,~ww+~+~+rw*www*r+www~~ra ' ~ ~Othelr• •Fees: ,.: ~... ;., ..:•...•;..•.....;.:..:. Date •Received::~•.•.`:• ~'~. •.:• • •......•.. • ,..•::: ,. ,; .: t ......:.... ..::.:.:• .Acre . . DRB Fees: ~::~:•.~<:. •~;::-. • •.::~: .. Page 1 of 2 11/23/2005 r:\cdev\FORMS\Permits\Dullding\electlcal~ennlC 11-23-2005.DOC CONTRACTOR INFORMATION tTOWl~ OF VAIL 75 S. FRONTAGE ROAD VAIL, CO 81657 970-479-213 8 ~ARTMENT OF COMMUNITY DEVEL~ENT NOTE: THIS PERMIT MUST BE POSTED ON JOBSITE AT ALL TIMES MECHANICAL PERMIT Permit #: M08-0069 "70~5-bdb( Job Address: 710 W LIONSHEAD CR VAIL ' ' Status ...: : Applied ISSUED 04/11/2008 Location.....: A 710 W. LIONSHEAD CR. UNIT .. .. Issued 04/14/2008 Parcel No...: 210106317056 . Expires . .: 10/11/2008 Legal Description: 066 ~ Project No OWNER WEBB, KYLE & LORAINNE PO BOX 2630 EDWQARDS CO 81632 APPLICANT SKYLINE MECHANICAL P.O. BOX 1258 GYPSUM CO 81637 License: 121-M CONTRACTOR SKYLINE MECHANICAL P.O. BOX 1258 GYPSUM CO 81637 License: 121-M 04/11/2008 04/11/2008 Phone: 970-524-6809 04/11/2008 Phone: 970-524-6809 Desciption: VAIL SPA OFFICE SPACE CONVERSION- MECHANICAL Valuation: $4,500.00 # of Gas A liances: 0 # of Gas Logs: 0 # of Wood Pellet: 0 Fireplace Information: Restricted: pp FEE SUMMARY *****************#**#*##*##*####**#*######*###*#*#*##*##*#*# ###*################*s############################*###s############# Mechanical--> S i o 0 .0 0 Restuarant Plan Review--> $ o. 0 o Total Calculated Fees-_> $ i z 9.0 0 Plan Check--> $ 2 5.0 0 TOTAL FEES--------------> $12 9.0 0 Additional Fees-----------> $ 0.0 0 Total Permit Fee---------> $1 z 9.0 0 lnvesti anon-> $ o . 0 0 g Will Call----> $ 4. o o Payments-----------------> $ i 2 9. 0 0 BALANCE DUE--------> $ o . 0 0 #####################################################################################################################################f########### Item: 05100 BUILDING DEPARTMENT 04/11/2008 cgunion Action: AP Item: 05600 FIRE DEPARTMENT CONDITION OF APPROVAL Cond: 12 (BLDG.): FIELD INSPECTIONS ARE REQUIRED TO CHECK FOR CODE COMPLIANCE. Cond: 22 (BLDG.): COMBUSTION AIR IS REQUIRED PER CHAPTER 7 OF THE 2003 IMC AND SECTION 304 OF THE 2003 IFGC AS MODIFIED BY TOWN OF VAIL. Cond: 23 (BLDG.): BOIILER INSTALLATION MUST CONFORM TO MANUFACTURER'S INSTRUCTIONS AND CHAPTER 10 OF THE 2003 IMC. :ConC": 25 (BLDG.): GAS APPLIANCES SHALL BE VENTED ACCORDING TO CHAPTER 5 OF THE 2003 IFGC. Cond: 29 (BLDG.): ACCESS TO MECHANICAL EQUIPMENT MUST COMPLY WITH CHAPTER 3 OF THE 2003 IMC AND CHAPTER 3 OF THE 2003 IFGC . Cond: 31 (BLDG.): BOILERS SHALL BE MOUNTED ON FLOORS OF NONCOMBUSTIBLE CONST. UNLESS LISTED FOR MOUNTING ON COMBUSTIBLE FLOORING. Cond: 32 (BLDG.): PERMIT,PLANS AND CODE ANALYSIS MUST BE POSTED IN MECHANICAL ROOM PRIOR TO AN INSPECTION REQUEST. Cond: 30 (BLDG.): BOILER ROOMS SHALL BE EQUIPPPED WITH A FLOOR DRAIN OR OTHER APPROVED MEANS FOR DISPOSING OF LIQUID WASTE PER SECTION 1004.6. #############################################f##############4#####;######f########################;###################################f#########i DECLARATIONS I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate plot plan, and state that all the information as required is correct. I agree to comply with the information and plot plan, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approved, International Building and Residential Codes and other ordinances of the Town applicable thereto. REQUESTS FOR INSPECTION SHALL BE MADE TWENTY-FOUR HOURS IN ADVANCE BY TELEPHONE AT 479-2149 OR AT OUR OFFICE FROM 8:00 AM - 4 PM. SIGNATURE OF OWNER OR CONTRACTOR FOR HIMSELF AND OWNER 04/14/2008 TOWN OF VAIL, COLORADOCopy Reprinted on 04-14-2008 at 09:15:31 Statement *************s*****************************~*******~********+**************+***+*********+** Statement Number: 8080000433 Amount: $129.00 04/14/200809:14 AM Payment Method: Check Init: RLF Notation: 12527 skyline mechanical Permit No: M08-0069 Type: MECHANICAL PERMIT Parcel No: 2101-063-1705-6 Site Address: 710 W LIONSHEAD CR VAIL Location: 710 W. LIONSHEAD CR. UNIT 'A' Total Fees: $129.00 This Payment: $129.00 Total ALL Pmts: $129.00 Balance: $0.00 ACCOUNT ITEM LIST: Current Pmts Account Code Description ----------------------- -------------------- MP 00100003111100 MECHANICAL PERMIT FEES 100.00 PF 00100003112300 PLAN CHECK FEES 25.00 WC 00100003112800 WILL CALL INSPECTION FEE 4.00 R r 10 2008 3:55PM kyline Mechanical IMC. 970-524-6810 P•1 P ~nwxoFx~u T5 5. Frontage Rd. vail_ Colorado 81657 ED IF INCOMPI.Ei'E OR UNSoG~ DR ~ 00 ~~~~~ Project #. ~~ Building Permit #~ ~" Mechanical Peririt #: ,~, ~ ~~~~ 970-479-2149 (Inspe~tifons) ' g70••g79 -~1 ~' cPh!~rK~ - -~ permit will not ~e accepted without the following: ___ _~_ ..~.•4.anicai Room ~yput drawn to scale tv indude: MECHANICAL: $ SDO.OD CONTRACTOR INFORMATION Town of Vail Reg. No.: Contact and Phone #'s: Mechanical Contractor: I ^ , _ ~ ` cr 1 ContradJOr Signature: **** OFFICE USE ONLY***************************** **~*~*************** i:OR,p~annerSi =off:. .. ..<. €~' .. ~ ~at~~ l~ereir+ed~ ~ ' ~•, 4~ F:/everyone/iormsl mechperrn I COIF°i-~TE VALUATION FQR thtc,n~u.aw~ • ...-- -- - - • 06- 4:2 .~ Inspection Request Re~or'tling Requested Inspect Date: Friday, June 13, 2008 Inspection Area: JP Site Address: X10 W. L O 3HEAD CRVUNIT'A' A/P/D Information Status: ISSUED T e A-COMM Sub Type: ACOM Activity: 608-0001 YP Use: IIA Insp Area: JP Const Type: Occupancy. Owner: WEBB, KYLE & LORAINNE Phone: 970-477-2990 Architect: K.H. WEBB ARCHITECTS PC phone: (970) 390-5111 Contractor: T. HORN ENTERPRISES INC. Description: VAIL SPA OFFICE SPACE CONVERSION-DEMO KITCHEN AND CONVERT TO OFFICE SPACE '~ ~ Requested Inspection(s1 ~ , ; , Item: 90 BLDG-Final ~ ~ Requested Time: 02:30 PM Phone: (970)yy390-pp5111 Requestor: T. HORN ENTERPRISES ANC. Entered By: DGOLDEN K Comments: building and mechanical finals are scheduled -will call Todd 390-5111, #A , as ear as ossible Assigned To: JMONDRAGON Time Exp: Action: 4 Inspection History Item: 501 PW-Temp access/drainage "* Approved ** I Action: AP APPROVED s 04/07/08 Inspector: Item: Comment: ** Approved *" 30 BLDG-Framing Action: AP APPROVED 05/06/08 Inspector: shahn d in 5/8" to maintain ceiling rating. inspect at insulation inspection. Item: e Comment: , skylights to be wrapp ** 50 BLDG-Insulation Approved ~N Action: AP APPROVED 05/09/08 Inspector: SHA Item: Comment: ** A roved "" S 5 60 BLD~ ~$ ° I GCD pp spec Action: AP APPROVED 5 / tor: n Comment: Item: 70 BLDG-Misc. Item: 90 BLDG-Final O C DG Fina Item: / l 540 BL Run Id: 8049 REPT131 age 30 Inspection Request rz~ny June 03, 2008 Requested Inspect Date: Tuesday, Inspection Area: CG Site Address: 710 W LLIONSHEAD CR UNIT 'A' AIPID Information Sub Type: ACOM Type: B-ELEC Use: Activity: E08-0044 pccu ancy: Const Type: Owner: WEBB, KYLE & LORAINN Phone: (970) 569-3913 Contractor: MD MOLLER CO Description: VAIL SPA OFFICE SPACE CONVERSION- electrical permit Requested Inspec Item: Requestor: Comments: Assig Action: Comment: Status: ISSUED Insp Area: CG tion(s) ~~ Requested Time: 08:30 AM 190 ELEC-Final Phone: 845-8039 MD MOLLER 0688-1154 Entered By: DGOLDEN K S~HAHNRandy Time Exp: TED AHEAD OF THE SWITCH AND OPERATE WHEN M LIGHTING TO BE~IIIQIQEC AREA LIGHTING FAILS. ~~ Inspection History Item: 110 ELEC-Service *• Approved "' Action: AP APPROVED Item: 120 ELEC-Rough 04/08/08 Inspector: shahn Comment: Item: 130 ELEC-Conduit Item: 140 ELEC-Misc. Action: CR CORRECTION REQUIRED Item: 190 ELEC-Final 06/02/08 Ins ector: shahn Comment: TH~ EXITS AND EMING FANS.TO BE CONNECTED AHEAD OF THE SWITCH AND OPERA WHEN AREA LIGHT Run Id: 8004 REPT131 06-12-2008 Inspection Request Re~olrting Page 63 .. .. /1 .L . ., Requested Inspect Date: Friday, June 13, 2008 Inspection Area: GD Site Address: ~~~ W LLION3HEAD CRVUNIT'A' A/P/D Information T e: B-MECH Sub Type: ACOM Status: ISSUED Activity: M08-0069 yp Use: Insp Area: GD Const Type: Occupancy: Owner: WEBS, KYLE & LORAINNE Contractor: SKYLINE MECHANICAL Phone: 970-524-6809 Description: VAIL SPA OFFICE SPACE CONVERSION- MECHANICAL Requested Insaection(sl /1 Item: 390 MECH-Final ~ ` Requested Time: 03:30 PM Requestor: SKYLINE MECHANICA Phone: 970-5yy24-6pp809, Comments: building and mechanical finals are scheduled -will call Todd 390-Entered By a DGOLDENoK able Assigned To: JMONDRAGON Time Exp: Action: ONTRACTOR Comment: ~~ Inspection Histo Item: 200 MECH-Rough Action: CR CORRECTION REQUIRED 04/30/08 Ins ector: GCD Comment: 1.PpROVIDE FIRE DAMPER AS NOT ON PLANS. 2.SEAL PENETRATIONS TO MAINTAIN 2 HOUR CONSTRUCTION AT BLOCK WALL. 4.PROVIDE ERV INISPTRUCTIONSUAT FGNAL CORRIDOR SUPPLY AIR. Item: 310 MECH-Heating_ Item: 315 PLMB-Gas Piping Item: 320 MECH-Exha~ sA9oods Item: 330 MECH-Supp y Item: 340 MECH-Misc. Item: 390 MECH-Final Action: NO NOTIFIED 06/06/08 Inspector: GCD Comment: CANCELED BY CONTRACTOR REPT131 Run Id: 8049