Loading...
HomeMy WebLinkAboutB17-0070_A3-07-05_1495578240.pdfUP BOILER REF. DW 05-A 05-B 05-1 05-2 05-3 05-4 EQ 7' - 6" EQ C 1' - 5 1/2" 1' - 3 1/2" D D 1' - 10" 3' - 6" 3' - 6" HOLD 3' - 0" KITCHEN LIVING BEDROOM MECH CLOSET BATH DINING 5' - 10" HOLD 3' - 0" HOLD 3' - 0" 11' - 1" 28' - 0" P J G 9' - 5" 2" 13' - 8" 4' - 0" 11" 3' - 0" 4 1/2" 5' - 0" 2.2-101 2.2-102 2.2-103 2.2-104 2.2-104 12 A6.02 11 A6.02 1 A5.01-05 2' - 5" 4' - 6" HOLD 3' - 0" 2' - 8 1/2" A6.02/ 8 A6.02/ 4 A6.02/ 3 A6.02/ 7 A6.02/ 6 A6.02/ 2 E1 E1 E1 C1C1 C1 A1A1A1 A1 A1 A1A1 WS-1 WS-1WS-1 WS-1 WS-2 WS-1 WS-1 WS-3 WS-1 C1 2' - 6" 7' - 8" 2' - 6" 1' - 9" G 5 G0.01-05 3' - 0" 5' - 0" 3' - 0" 3' - 4" 05-A 05-B 05-1 05-2 05-3 05-4 BATH CLOSET BEDROOM LIVING DINING KITCHEN CENTER OVER ISLAND EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ 3' - 3" 1' - 9" 6' - 0" EQ 6' - 0" EQ 3' - 0" EQ EQ 3' - 8" 3' - 6" EQ EQ EQ EQ WR MECH EQ EQ 05-A 05-B 05-1 05-2 05-3 05-4 LVT-01 CPT-01 CPT-01 T-01 BATH BEDROOM LIVING KITCHEN DINING MECH CLOSET LVT-01 T-01 CPT-01 LVT-01 CPT-01 LVT-01 PL-01 PL-03 PL-04 EQ-09 LVT-01 CN-02 CN-02 PL-05 EQ-02 EQ-01 EQ-04 EQ-03 FINISH PLAN GENERAL NOTES 1. REFER TO SHEET A3.01 FOR FINISH SCHEDULE 2. ALL WALLS TO BE P-01, EGGSHELL. ALL TRIM TO BE P-02, EGGSHELL. ALL CEILINGS TO BE P-02, FLAT. 3. ALL WALL BASE TO HAVE MITERED EDGES. FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O. 2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF STRUCTURE U.N.O. 3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET 4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O. 5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING, U.N.O. 6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT. 7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR DRAWINGS 8. FURNITURE IS SHOWN FOR REFERENCE ONLY 9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE FLOOR PLAN, REFLECTED CEILING PLAN AND FINISH PLANS FOR EACH UNIT AND LEVEL 10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND FOR DESIGNATIONS OF EXTERIOR MATERIALS. 11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL SECTIONS 12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW INFORMATION, SCHEDULES AND DETAILS 13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR FINISH INFORMATION AND SCHEDULES 14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY LOCATED COMMON AREA PER LOCAL CODE 15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD INSTALLATIONS THAT OCCUR AT SLAB ON GRADE CONDITIONS 16. ALL EXPOSED CONCRETE FOUNDATION WALLS, CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC 17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS 18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O. 19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING 20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE THERE IS A GRADE CHANGE OF 30" OR MORE REFLECTED CEILING NOTES: 1. NOTIFY ARCHITECT OF DISCREPANCY UPON DISCOVERY PRIOR TO PROCEEDING WITH SAID WORK. 2. ALL CEILING SHALL BE 9'-0" A.F.F, UNLESS NOTED OTHERWISE. 3. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATION OF SPRINKLER HEADS. CENTER FIRE SPRINKLER HEADS BOTH DIRECTIONS IN CEILING TILES. ALL CORRIDOR SPRINKLER HEADS SHALL BE ALIGNED AND CENTERED IN SAID SPACE. 4. SUBMIT LAYOUT OF ALL GYPSUM BOARD CEILING CONTROL JOINTS FOR REVIEW. 5. MINOR DISCREPANCIES BETWEEN MEP AND ARCHITECTURAL DOCUMENTS IN REGARD TO LOCATION OF CEILING MOUNTED COMPONENTS, ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN. 6. RE: MECHANICAL AND ELECTRICAL DRAWINGS FOR MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS REQUIRED OR INDICATED. 7. IN ALL MECHANICAL/BOILER ROOMS; CONTINUE PARTITION, WALL ASSEMBLY TO STRUCTURE OR BOTTOM OF CEILING WITH FIRE STOPS AS REQUIRED IN INTERSTICIAL SPACE. SEAL ALL JOINTS PER SYSTEM. PROVIDE FIRE SEALANT AT ALL PENETRATIONS AND HEADS OF WALL 8. CEILINGS ABOVE SHOWERS/BATHS WILL RECIEVE MOISTURE RESISTANT GYP. BD., TYPE 'X' 9. PENDANT LIGHTS ABOVE KITCHEN BAR TO BE SET 2'-6" ABOVE COUNTER HEIGHT. PRE-MARK AND VERIFY ALL LOCATIONS W/ INTERIORS. 10. PROVIDE BATT INSULATION IN ALL FLOORS, CEILING AND WALLS SURROUNDING BATH/SHOWER, MECHANICAL AND WASHER/DRYER ROOMS/CLOSETS. 11. CENTER ALL CEILING GRIDS IN EACH ROOM OR SPACE UNLESS OTHERWISE INDICATED WITH A GRID ORIGIN OR DIMENSION. 12. ACCESS DOOR LOCATIONS IN GYPSUM BOARD CEILINGS ARE INDICATED WHERE ARCHITECTURALLY SIGNIFICANT. 13. SPRINKLER SPRINKLER TO BE DESIGNED BY FIRE PROTECTION ENGINEER. COORDINATE ALL LOCATIONS WITH ARCHITECT. LIGHTING LEGEND 6" RECESSED LIGHT 2' X 4' FLOURESCENT LIGHT 6" DOWNLIGHT - WALL WASHER EXTERIOR WALL LAMP MOTION SCENSORED TUBE LIGHT (TYP. FOR CLOSETS) CEILING FAN W/ LIGHT BATHROOM CEILING FAN J JUNCTION BOX 4.8" PENDENT LIGHT 18" DRUMB PENDANT VANITY WALL LIGHT 1' X 4' FLOURESCENT LIGHT PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP FOR REFERENCE ONLY 4/26/2017 11:25:47 AM C:\Users\lfrazier\Documents\CHAMONIX_Building Models_lfrazier.rvt A3.07-05 BUILDING 05 - UNIT 2.2 B - LEVEL 02 14054.1 CHAMONIX - VAIL FOUNDATION PERMIT APRIL 26, 2017 1/4" = 1'-0" 1 UNIT 2.2 B - LEVEL 02 - FLOOR PLAN 1/4" = 1'-0" 2 UNIT 2.2 B - LEVEL 02 - RCP 1/4" = 1'-0" 3 UNIT 2.2 B - LEVEL 02 - FINISH PLAN No. Description Date 05/23/17