HomeMy WebLinkAboutB17-0071_A2-02-06_1495578420.pdfW D
06-A 06-B 06-C 06-D
06-1
06-2
06-3
06-4
A4.01-06/ 2
A4.01-06/ 4
A4.01-06/ 1
A4.01-06/ 3
26' - 2 1/2" 26' - 4" 26' - 2 1/2"
4' - 0"
22' - 11" 4' - 0" 30' - 11"
78' - 9"
UNIT TYPE 3.1A
UNIT TYPE 3.2B UNIT TYPE 3.1B
1
A5.01-06
A2/ 1
2
A5.01-06
1
A5.02-06
2
A5.02-06
06-A 06-B 06-C 06-D
06-1
06-2
06-3
06-4
26' - 2 1/2" 26' - 4" 26' - 2 1/2"
4' - 0" 22' - 11" 4' - 0" 30' - 11" 78' - 9"
A4.01-06/ 2 A4.01-06/ 4 A4.01-06/ 1
A4.01-06/ 3 3" / 12" 3" / 12" 3" / 12" 3" / 12"
1
A5.01-06
A2/ 1
2
A5.01-06
1
A5.02-06
2
A5.02-06
HATCHED AREA INDICATED 4'-0" OFF
OF DEMISING WALL CENTERLINE,
F.R.P. SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA
4' - 0" 4' - 0" 4' - 0" 4' - 0"
SNOW CLEATS, TYP.
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O.
2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF
STRUCTURE U.N.O.
3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET
4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O.
5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING,
U.N.O.
6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS BUILT
MFR. STANDARDS TO BE REVIEWED BY ARCHITECT.
7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR
DRAWINGS
8. FURNITURE IS SHOWN FOR REFERENCE ONLY
9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE
FLOOR PLAN, REFLECTED CEILING PLAN AND FINISH PLANS
FOR EACH UNIT AND LEVEL
10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND
FOR DESIGNATIONS OF EXTERIOR MATERIALS.
11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL
SECTIONS
12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW
INFORMATION, SCHEDULES AND DETAILS
13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR
FINISH INFORMATION AND SCHEDULES
14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE
DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY
LOCATED COMMON AREA PER LOCAL CODE
15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD
INSTALLATIONS THAT OCCUR AT SLAB ON GRADE
CONDITIONS
16. ALL EXPOSED CONCRETE FOUNDATION WALLS,
CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR
ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC
17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS
18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O.
19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL
FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING
20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE
THERE IS A GRADE CHANGE OF 30" OR MORE
ROOF PLAN GENERAL NOTES
1. ROOF TYPES ARE AS FOLLOWS:
ROOF TYPE 1: ASPHALT SHINGLE ROOF, 30 YEAR
ROOF TYPE 2: STANDING SEAM METAL ROOF
2. ALL ROOFING SURFACES TO SLOPE 1/4" VERTICAL PER 1' - 0"
HORIZONTAL
MINIMUM, U.N.O.
3. TOP OF INSULATION HEIGHTS, HIGH POINTS AND LOW POINTS,
ARE INDICATED
AS THE TOP OF ROOF SURFACE ABOVE THE ROOF DRAIN(S).
(I.E. + 3.5"
WHERE HIGH POINT OF ROOF DRAIN SUMP IS +0"
4. REFER TO SHEET A5.02 FOR TYPICAL ROOF DETAILS.
5. ALL ROOF TOP MECHANICAL, ELECTRICAL AND/OR PLUMBING
EQUIPMENT SHOWN FOR INFORMATION ONLY. REFERENCE
MECHANICAL, ELECTRICAL AND PLUMBING DOCUMENTS AND
SPECIFICATIONS FOR SPECIFIC DESIGN INFORMATION.
6. ICE DAM BARRIER OF AT LEAST TWO LAYERS OF
UNDERLAYMENT CEMENTED TOGETHER OR OF A SELF-
ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL
EXTEND FROM THE ROOF EAVE EDGE AT LEAST SIX FEET
INSIDE THE EXTERIOR WALL LINE AS MEASURED ALONG THE
ROOF SURFACE, EIGHTEEN INCHES FROM THE CENTERLINE
OF THE VALLEY AND UP TWENTY-FOUR INCHES ON THE
VERTICAL WALL AT A ROOF AND WALL JUNCTURE.
(ORDINANCE 31, 2001, PG 13) R905.2.7.1 ICE BARRIER
1
2
3
4
5
6 7
8
9
10
KEY PLAN
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
FOR REFERENCE
ONLY
4/26/2017
11:20:22 AM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
A2.02-06
BUILDING 06 - FLOOR
PLANS
14054.1
CHAMONIX - VAIL
FOUNDATION PERMIT
APRIL 26, 2017
3/16" = 1'-0"
1 BUILDING 06 - LEVEL 03
3/16" = 1'-0"
2 BUILDING 06 - ROOF PLAN
No. Description Date
05/23/17