HomeMy WebLinkAboutB17-0071_A3-09-06_1495578420.pdf06-C
06-D
06-1
06-2
06-3
06-4
1
A5.01-06
MASTER
BEDROOM
CLOSET
MASTER BATH
CLOSET
HALLWAY
EQ 7' - 6" EQ
29' - 0"
C
L 4' - 7" 6' - 5" 5' - 5 1/2"
HOLD
3' - 0"
3' - 9"
13' - 9"
1' - 11" 4' - 0" 2' - 0" 3' - 10"
3.1-202
3.1-203
3.1-201
2
A5.01-06
2
A5.01-07
HOLD
3' - 0"
3 1/2"
ALIGN
8' - 1 1/2"
A6.03/ 5
A6.03/ 1
E1
H 6' - 0"
3' - 3 1/2" K
WS-4
WS-3
WS-3
WS-3WS-3
WS-3
A1
A1
5
G0.01-06
06-C 06-D
06-1
06-2
06-3
06-4
MASTER
BEDROOM
CLOSET
CLOSET
MASTER BATH
HALLWAY
EQ EQ
EQ
EQ EQ EQ
EQ EQ
EQ 5' - 0" EQ 1' - 6"
6' - 0"
EQ EQ
EQ EQ
1' - 8"
2' - 2"
EQ EQ
WR
06-C 06-D
06-1
06-2
06-3
06-4
MASTER
BEDROOM
CLOSET
CLOSET
MASTER BATH
HALLWAY
CPT-01
CPT-01
T-02
PL-03
PL-02
PL-04
PL-04 T-02CPT-01
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O.
2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF
STRUCTURE U.N.O.
3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET
4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O.
5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING,
U.N.O.
6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS BUILT
MFR. STANDARDS TO BE REVIEWED BY ARCHITECT.
7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR
DRAWINGS
8. FURNITURE IS SHOWN FOR REFERENCE ONLY
9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE
FLOOR PLAN, REFLECTED CEILING PLAN AND FINISH PLANS
FOR EACH UNIT AND LEVEL
10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND
FOR DESIGNATIONS OF EXTERIOR MATERIALS.
11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL
SECTIONS
12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW
INFORMATION, SCHEDULES AND DETAILS
13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR
FINISH INFORMATION AND SCHEDULES
14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE
DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY
LOCATED COMMON AREA PER LOCAL CODE
15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD
INSTALLATIONS THAT OCCUR AT SLAB ON GRADE
CONDITIONS
16. ALL EXPOSED CONCRETE FOUNDATION WALLS,
CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR
ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC
17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS
18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O.
19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL
FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING
20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE
THERE IS A GRADE CHANGE OF 30" OR MORE
REFLECTED CEILING NOTES:
1. NOTIFY ARCHITECT OF DISCREPANCY UPON DISCOVERY
PRIOR TO PROCEEDING WITH SAID WORK.
2. ALL CEILING SHALL BE 9'-0" A.F.F, UNLESS NOTED
OTHERWISE.
3. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATION
OF SPRINKLER HEADS. CENTER FIRE SPRINKLER HEADS
BOTH DIRECTIONS IN CEILING TILES. ALL CORRIDOR
SPRINKLER HEADS SHALL BE ALIGNED AND CENTERED IN
SAID SPACE.
4. SUBMIT LAYOUT OF ALL GYPSUM BOARD CEILING
CONTROL JOINTS FOR REVIEW.
5. MINOR DISCREPANCIES BETWEEN MEP AND
ARCHITECTURAL DOCUMENTS IN REGARD TO LOCATION
OF CEILING MOUNTED COMPONENTS, ARCHITECTURAL
REFLECTED CEILING PLAN SHALL GOVERN.
6. RE: MECHANICAL AND ELECTRICAL DRAWINGS FOR
MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS
REQUIRED OR INDICATED.
7. IN ALL MECHANICAL/BOILER ROOMS; CONTINUE
PARTITION, WALL ASSEMBLY TO STRUCTURE OR BOTTOM
OF CEILING WITH FIRE STOPS AS REQUIRED IN
INTERSTICIAL SPACE. SEAL ALL JOINTS PER SYSTEM.
PROVIDE FIRE SEALANT AT ALL PENETRATIONS AND
HEADS OF WALL
8. CEILINGS ABOVE SHOWERS/BATHS WILL RECIEVE
MOISTURE RESISTANT GYP. BD., TYPE 'X'
9. PENDANT LIGHTS ABOVE KITCHEN BAR TO BE SET 2'-6"
ABOVE COUNTER HEIGHT. PRE-MARK AND VERIFY ALL
LOCATIONS W/ INTERIORS.
10. PROVIDE BATT INSULATION IN ALL FLOORS, CEILING AND
WALLS SURROUNDING BATH/SHOWER, MECHANICAL AND
WASHER/DRYER ROOMS/CLOSETS.
11. CENTER ALL CEILING GRIDS IN EACH ROOM OR SPACE
UNLESS OTHERWISE INDICATED WITH A GRID ORIGIN OR
DIMENSION.
12. ACCESS DOOR LOCATIONS IN GYPSUM BOARD CEILINGS
ARE INDICATED WHERE ARCHITECTURALLY SIGNIFICANT.
13. SPRINKLER SPRINKLER TO BE DESIGNED BY FIRE
PROTECTION ENGINEER. COORDINATE ALL LOCATIONS
WITH ARCHITECT.
LIGHTING LEGEND
6" RECESSED LIGHT 2' X 4' FLOURESCENT
LIGHT
6" DOWNLIGHT - WALL WASHER
EXTERIOR WALL LAMP
MOTION SCENSORED TUBE LIGHT
(TYP. FOR CLOSETS)
CEILING FAN W/
LIGHT
BATHROOM CEILING FAN
J JUNCTION BOX
4.8" PENDENT LIGHT 18" DRUMB PENDANT
VANITY WALL LIGHT
1' X 4' FLOURESCENT
LIGHT
FINISH PLAN GENERAL NOTES
1. REFER TO SHEET A3.01 FOR FINISH SCHEDULE
2. ALL WALLS TO BE P-01, EGGSHELL. ALL TRIM TO BE P-02,
EGGSHELL. ALL CEILINGS TO BE P-02, FLAT.
3. ALL WALL BASE TO HAVE MITERED EDGES.
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
FOR REFERENCE
ONLY
4/26/2017
11:20:40 AM C:\Users\lfrazier\Documents\CHAMONIX_Building
Models_lfrazier.rvt
A3.09-06
BUILDING 06 - UNIT 3.1
A - LEVEL 03
14054.1
CHAMONIX - VAIL
FOUNDATION PERMIT
APRIL 26, 2017
1/4" = 1'-0"
1 UNIT 3.1 A - LEVEL 03 - FLOOR PLAN
1/4" = 1'-0"
2 UNIT 3.1 A - LEVEL 03 - RCP
1/4" = 1'-0"
3 UNIT 3.1 A - LEVEL 03 - FINISH PLAN
T-02
CPT-01
No. Description Date
05/23/17