Loading...
HomeMy WebLinkAboutB17-0072_A9-04_1495578600.pdf(2) 2X6 SILL PLATE 2X6 SILL PLATE 1" X 4" BASE TRIM, RE: FINISH SCHEDULE 5/8" GYP BD 7/16" FIRE RATED OSB SHEATHING RE: SYSTEMS BUILT MFR 2" AIR GAP 5/8" GYP BD (2) 2X12 RIM JOISTS SPRAY FOAM INSULATION R-21 MIN. 7/8" T&G PLYWOOD SHEATHING RE: SYSTEMS BUILT MFR FINISH FLOOR, RE: FINISH SCHEDULE 5/8" GYP BD 7/16" FIRE RATED OSB SHEATHING, RE: SYSTEMS BUILT MFR 2" BATT INSULATION FOR FIREBLOCK BETWEEN MODULES 1-HR WALL 1-HR WALL 2-HR WALL 1-HR WALL (2) LAYERS 5/8" GYP BD. 7/16" FIRE RATED OSB SHEATHING, RE: SYSTEMS BUILT MFR 1 3/8" AIR GAP (2) 2X6 SILL PLATE 5/8" GYP BD. (2) 2X12 RIM JOISTS SPRAY FOAM INSULATION, R-21 MIN. 2X10 RIM JOIST 2X4 SILL PLATE SPRAY FOAM INSULATION, R-21 MIN. R-11 BLANKET INSULATION W/ NET REST FOR FIRE BLOCKING BETWEEN JOISTS 7/16" OSB SHEATHING, RE; SYSTEMS BUILT MFR 1"x4" BASE TRIM, RE: FINISH SCHEDULE FINISH FLOOR, RE: FINISH SCHEDULE 7/8" T&G PLYWOOD SHEATHING, RE: SYSTEMS BUILT MFR. 2X6 SILL PLATE 7/16" FIRE RATED OSB SHEATHING, RE: SYSTEMS BUILT MFR BATT INSULATION FOR FIREBLOCK BETWEEN MODULES (1) LAYER 5/8" GYP BD. (2) LAYERS 5/8" GYP BD. 7/16" OSB SHEATHING, RE; SYSTEMS BUILT MFR 2X4 PERIMETER BLOCKING FOR TRUSS BEARING TRUSS W/ CONTINUOUS 7/16" FIRE RATED SHEATHING AIR SPACE SIDE AND 5/8" GYP. BD. ATTIC SIDE. ALL JOINTS TO BE TAPED AND ALL PENETRATIONS TO BE FULLY FIRE CAULKED TRUSSED ROOF, RE: STRUCT. R-49 BATT INSULATION THROUGHOUT ENTIRE ATTIC SPACE VENTED ROOF 2" 2" BATT INSULATION FOR FIREBLOCK BETWEEN MODULES 5/8" GYP BD. 7/16" FIRE RATED OSB SHEATHING, RE: SYSTEMS BUILT MFR 2" AIR GAP (2) 2X6 SILL PLATE 5/8" GYP BD. (2) 2X12 RIM JOISTS SPRAY FOAM INSULATION, R-21 MIN. 2X10 RIM JOIST 2X4 SILL PLATE SPRAY FOAM INSULATION, R-21 MIN. R-11 BLANKET INSULATION W/ NET REST FOR FIRE BLOCKING BETWEEN JOISTS 7/16" OSB SHEATHING, RE; SYSTEMS BUILT MFR 1"x4" BASE TRIM, RE: FINISH SCHEDULE FINISH FLOOR, RE: FINISH SCHEDULE 7/8" T&G PLYWOOD SHEATHING, RE: SYSTEMS BUILT MFR. 2X6 SILL PLATE 2" 7/16" FIRE RATED OSB SHEATHING, RE: SYSTEMS BUILT MFR BATT INSULATION FOR FIREBLOCK BETWEEN MODULES 1-HR WALL 1-HR WALL 2" 5/8" GYP BD. 7/16" FIRE RATED OSB SHEATHING, RE: SYSTEMS BUILT MFR 2" AIR GAP (2) 2X6 SILL PLATE 5/8" GYP BD. 2X10 RIM JOIST 7/16" OSB SHEATHING, RE; SYSTEMS BUILT MFR 2X4 PERIMETER BLOCKING FOR TRUSS BEARING GIRDER TRUSS W/ CONTINUOUS 7/16" FIRE RATED SHEATHING AIR SPACE SIDE AND 5/8" GYP. BD. ATTIC SIDE. ALL JOINTS TO BE TAPED AND ALL PENETRATIONS TO BE FULLY FIRE CAULKED TRUSSED ROOF, RE: STRUCT. 7/16" FIRE RATED SHEATHING AND 5/8" GYP. BD. HELD TIGHT TO BOTTOM OF ROOF SHEATHING, FULLY FIRE CAULK ALL JOINTS PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. 2" BATT INSULATION FOR FIREBLOCK BETWEEN MODULES PROPERTY LINE 4'-0" 1-HR RATEDSHEATHIN G 4'-0"1-HR RATEDSHEATHING 1-HR RATED ROOF SHEATHING 4'-0" EITHER SIDE OF PROPERTY LINE R-49 BATT INSULATION THROUGHOUT ENTIRE ATTIC SPACE UNVENTED ROOF VENTED ROOF ROOF SHEATHING OVER R-5 CONTINUOUS RIGID INSULATION (VERT AND HORZ JOINTS OFFSET FROM ROOF SHEATHING) OVER ROOF SHEATHING R-19 BATT INSULATION INSTALLED W/ WIRE STAYS OR NETTED CELLULOSE CEMENT BOARD SOFFIT OVER 7/16" FIRE RATED SHEATHING ATTACHED TO BOTTOM OF TRUSS LAP ICE AND WATER SHIELD OVER PREFINISHED MTL FLASHING CONTINUOUS SUB-FASCIA, RE: STRUCTURAL CONTINUOUS 2X FASCIA CONTINUOUS 2X10 FASCIA TRIM ROOF TRUSS RE: STRUCT 2' - 0" PROPERTY LINE 4'-0" 1-HR RATED SHEATHING 1-HR RATED SHEATHING UNVENTED ROOF TRUSS W/ CONTINUOUS 7/16" FIRE RATED SHEATHING AIR SPACE SIDE AND 5/8" GYP. BD. ATTIC SIDE. ALL JOINTS TO BE TAPED AND ALL PENETRATIONS TO BE FULLY FIRE CAULKED TRUSSED ROOF, RE: STRUCT. RAINSCREEN SYSTEM LAP DN OVER DRIP FLASHING, RE: SPEC. MIN. 2" PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER OSB SHEATHING, RE: STRUCT. 1-HR RATED ROOF SHEATHING 4'-0" OF PROPERTY LINE DRIP FLASHING OVER SIDEWALL STEP FLASHING EXTEND ICE & WATER SHIELD MIN. 1'-0" UP WALL 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION OVER 5/8" EXT. GYP BD OVER 7/16" FIRE RATED SHEATHING, RE: SPEC. HORZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC PREFINISHED METAL FLASHING 1" FULLY BLOCK BETWEEN TRUSSES, 7/16" FIRE RATED SHEATHING AND 5/8" GYP. BD. HELD TIGHT TO BOTTOM OF ROOF SHEATHING, FULLY FIRE CAULK ALL JOINTS ROOF SHEATHING OVER R-5 CONTINUOUS RIGID INSULATION (VERT AND HORZ JOINTS OFFSET FROM ROOF SHEATHING) OVER ROOF SHEATHING PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF (2) LAYERS 5/8" GYP BD. SPRAY FOAM INSULATION, R-21 MIN. R-19 BATT INSULATION INSTALLED W/ WIRE STAYS OR NETTED CELLULOSE R-19 BATT INSULATION INSTALLED W/ WIRE STAYS OR NETTED CELLULOSE RIGID INSULATION HELD TIGHT TO BOTTOM OF ROOF SHEATHING (2) 2X6 SILL PLATE 5/8" GYP BD. 2X10 RIM JOIST (2) 2X6 SILL PLATE 2X6 SILL PLATE 1" X 4" BASE TRIM, RE: FINISH SCHEDULE (2) LAYERS 5/8" GYP BD 7/16" FIRE RATED OSB SHEATHING RE: SYSTEMS BUILT MFR 1 3/8" AIR GAP (1) LAYER 5/8" GYP BD (2) 2X12 RIM JOISTS SPRAY FOAM INSULATION R-21 MIN. 7/8" T&G PLYWOOD SHEATHING RE: SYSTEMS BUILT MFR FINISH FLOOR, RE: FINISH SCHEDULE 5/8" GYP BD 7/16" FIRE RATED OSB SHEATHING, RE: SYSTEMS BUILT MFR 2" BATT INSULATION FOR FIREBLOCK BETWEEN MODULES 2-HR WALL 1-HR WALL (2) LAYERS 5/8" GYP BD PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP FOR REFERENCE ONLY 4/26/2017 11:17:01 AM C:\Users\lfrazier\Documents\CHAMONIX_Building Models_lfrazier.rvt A9.04 DEMISING WALL DETAILS 14054.1 CHAMONIX - VAIL FOUNDATION PERMIT APRIL 26, 2017 1 1/2" = 1'-0" 3 1-HR DEMISING WALL @ LEVEL 2 1 1/2" = 1'-0" 5 2-HR DEMISING WALL @ LEVEL 3 1 1/2" = 1'-0" 2 1-HR DEMISING WALL @ FLOOR LEVEL 3 1 1/2" = 1'-0" 1 1-HR DEMISING WALL @ ROOF 1 1/2" = 1'-0" 4 2-HR DEMISING WALL @ LOWER/UPPER ROOF 1 1/2" = 1'-0" 9 2-HR DEMISING WALL @ LEVEL 2 No. Description Date 05/23/17