HomeMy WebLinkAboutB17-0072_REV2 Approved plans_1510762566.pdfBuilding 7 - Foundation
Details
2015-453.001
05/30/17
S5.01-07CHAMONIX - VAIL.TOWN OF VAIL
PERMIT SET
DISCIPLINE STAMP
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
TOWN STAMP
CONSULTANT
DRAWN BY:
CHECKED BY:3/1/2017 2:04:54 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvt118 West Sixth Street, Suite 200
Glenwood Springs, CO 81601
970.945.1004 www.sgm-inc.com
JJP
MN
Town of Vail Permit Set
2 Demising Wall Revisions 9/21/2017
09/21/17
provide
fire
rated
assem
bly
type
11/15/17
MIN.6"2 COAT STUCCO SYSTEM
OVER GALVANIZED FURRED
WIRE MESH, RE: SPEC
RAINSCREEN SYSTEM LAP DN
OVER METAL DRIP FLASHING,
RE: SPEC
1" R-5 MIN. FOIL FACED POLYSTYRENE
INSULATION, RE: SPEC
STUCCO J BEAD CLOSER
TUFF-N-DRI FOUNDATION DRAINAGE
SYSTEM - PROTECTION BOARD
OVER DRAINAGE MATT OVER RIGID
INSULATION, RE: SPEC.
T.O. CONC. @ LEVEL 1
2" INSULATION BOARD
4" CONC. SLAB, RE: STRUCT.
CONC. FOUNDATION
WALL, RE: STRUCT.
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR
PRE-FINISHED METAL FLASHING
5/8" GYP. BD.
2X6 PT WOOD SILL OVER
FOAM GASKET
R-21 MIN. UNFACED BATT
INSULATION, RE: SPEC
UNDER SLAB VAPOR BARRIER,
RE: SPEC.
1/2" EXPANSION JOINT, RE: STRUCT
NUDO WRAP - GROUND
BREAKER, RE: SPEC.
FLUID APPLIED MEMBRANE AIR
BARRIER, RE: SPEC.
GRANULAR FILL, RE: STRUCT.
FINISH FLOOR, RE: FINISH
SCHEDULE
CONTINUOUS BEAD OF SEALANT
GARAGE T.O. CONC.
FIBEROUS EXPANSION
MATERIAL, RE: CIVIL
EXTERIOR WALL
BEYOND. RE. PLAN
TUFF-N-DRI FOUNDATION
DRAINAGE SYSTEM - PROTECTION
BOARD OVER DRAINAGE MATT
OVER RIGID INSULATION, RE: SPEC.
CONC. FOUNDATION
WALL, RE: STRUCT.
4" ASPHALT DRIVEWAY OVER
OVER GRANULAR FILL, RE: CIVIL.
FLUID APPLIED MEMBRANE AIR
BARRIER, RE: SPEC.
CONC. SLAB @ GARAGE DOOR
OPENING, RE: STRUCT.
UNDER SLAB VAPOR
BARRIER, RE: SPEC.
GRANULAR FILL, RE: STRUCT.
SEALED CONC. GARAGE FLOOR,
RE: FINISH SCHEDULE
2" INSULATION BOARD
NOTE: DETAILS DO NOT
REFLECT ALL FINISH
CONDITIONS - SEE PLANS AND
FINISH PLANS FOR BUILDING
MATERIALS
NOTE: SEE STRUCUTRAL
DETAILS FOR INFORMATION
REGARDING DIMENSIONS, ETC.
4" CONCRETE SLAB OVER 10 MIL
VAPOR BARRIER OVER 2" RIGIDN
INSULATION OVER GRANULAR
FILL, RE: STRUCT.
UNIT DEMISING WALL, RE:
PLAN AND PARTITION TYPES
A0.01 FOR WALL TYPE
2X6 PT SILL SILL PLATES OVER
FOAM GASKET W/ ANCHOR
BOLTS, RE: STRUCT
FINISH FLOOR, RE:
PLAN AND FINISH
SCHEDULE
CONTINUOUS BEAD OF SEALANT
FILTER FABRIC
PERFORATED DRAIN PIPE -
PERIMETER DRAIN RE: CIVIL
FURRING WALL W/ MIN. R-13
UNFACED BATT INSULATION
@ FINISHED SPACE, RE: PLAN
TUFF-N-DRI FOUNDATION
DRAINAGE SYSTEM -
PROTECTION BOARD OVER
DRAINAGE MATT OVER RIGID
INSULATION, RE: SPEC.
CONC. FOUNDATION
WALL, RE: STRUCT.
FLUID APPLIED MEMBRANE
AIR BARRIER, RE: SPEC.
2" INSULATION BOARD
4" CONC. SLAB, RE: STRUCT.
2X4 PT WOOD SILL OVER
FOAM GASKET
UNDER SLAB VAPOR
BARRIER, RE: SPEC.
GRANULAR FILL, RE: STRUCT.
FINISH FLOOR, RE: FINISH
SCHEDULE
1/2"
1/2" EXPANSION JOINT, RE:
STRUCT.
T.O. CONC. @ LEVEL 1
PERIMETER DRAIN
RE: CIVIL 6" MIN.WINDOW PER SCHEDULE,
RE: SPEC.
PVC PIPE DISCHARGED
ONTO GRAVEL, RE: CIVIL
2" INSULATION BOARD
4" CONC. SLAB, RE: STRUCT.
5/8" GYP. BD.
2X4 PT WOOD SILL OVER
FOAM GASKET
R-13 MIN. UNFACED BATT
INSULATION, RE: SPEC
UNDER SLAB VAPOR BARRIER,
RE: SPEC.
1/2" EXPANSION JOINT, RE:
STRUCT
GRANULAR FILL, RE: STRUCT.
FINISH FLOOR, RE: FINISH
SCHEDULE
LOOSE GRAVEL, RE: CIVIL
WINDOW WELL
DRAIN, RE: CIVIL
WINDOW WELL RE: SPEC: 7/8"
BACKER ROD AND SEALANT
PRE-FINISHED METAL FLASHING
NUDO WRAP - GROUND
BREAKER, RE: SPEC
TUFF-N-DRI FOUNDATION DRAINAGE
SYSTEM - PROTECTION BOARD
OVER DRAINAGE MATT OVER RIGID
INSULATION, RE: SPEC.
FLUID APPLIED MEMBRANE
AIR BARRIER, RE: SPEC
CONC. FOUNDATION
WALL, RE: STRUCT.
PT 2X BLOCKING
5/4" PAINTED WOOD TRIM
RE: FINISH SCHEDULE
RAINSCREEN SYSTEM, RE: SPEC.
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR.
2X6 SILL PLATE
5/4" x 4" STAINED CEDAR
TRIM, RE: SPEC.
STUCCO J BEAD CLOSER
BACKER ROD AND SEALANT
2 COAT STUCCO SYSTEM OVER
GALVANIZED FURRED WIRE MESH,
RE: SPEC
1 1/2" R-7.5 MIN. POLYSTYRENE
INSULATION, RE: SPEC.3"1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION,
RE: SPEC.
1'X4" BASE TRIM, RE:
FINISH SCHEDULE
5/8" GYP. BD.HORZ. STAINED CEDAR SHIP
LAP SIDING, RE: SPEC
(2) 2X12 RIM JOISTS
SPRAY FOAM INSULATION, R-21
MIN.
(2) 2X6 SILL PLATES
PREFINISHED METAL FLASHING
5/8" GYP. BD.
CONC. FOUNDATION WALL,
RE: STRUCT.
7/8" T&G PLYWOOD SHEATHING,
RE: SYSTEMS BUILT MFR.
NOTE: DETAILS DO NOT
REFLECT ALL FINISH
CONDITIONS - SEE PLANS AND
FINISH PLANS FOR BUILDING
MATERIALS
NOTE: SEE STRUCUTRAL
DETAILS FOR INFORMATION
REGARDING DIMENSIONS, ETC.
4" CONCRETE SLAB OVER 10
MIL VAPOR BARRIER OVER 2"
RIGID INSULATION OVER
GRANULAR FILL, RE: STRUCT.
UNIT DEMISING WALL, RE:
PLAN AND PARTITION TYPES
A0.01 FOR WALL TYPE
2X6 PT SILL SILL PLATES OVER
FOAM GASKET W/ ANCHOR
BOLTS, RE: STRUCT
CONTINUOUS BEAD OF SEALANT
FINISH FLOOR, RE:
PLAN AND FINISH
SCHEDULE SLAB SLOPEVARIES WITH1"2 COAT STUCCO SYSTEM
OVER GALVANIZED FURRED
WIRE MESH, RE: SPEC
RAINSCREEN SYSTEM LAP DN
OVER METAL DRIP FLASHING,
RE: SPEC
1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION,
RE: SPEC
STUCCO J BEAD CLOSER
TUFF-N-DRI FOUNDATION
DRAINAGE SYSTEM -
PROTECTION BOARD OVER
DRAINAGE MATT OVER RIGID
INSULATION, RE: SPEC.
T.O. CONC. @ LEVEL 1
CONC. FOUNDATION
WALL, RE: STRUCT.
7/16" EXTERIOR OSB SHEATHING,
RE: SYSTEMS BUILT MFR
PRE-FINISHED METAL
FLASHING
4" CONC. ENTRY PATIO OVER
GRANULAR FILL, RE: STRUCT.
FLUID APPLIED MEMBRANE AIR
BARRIER, RE: SPEC.
2" INSULATION BOARD
4" CONC. SLAB, RE: STRUCT.
5/8" GYP. BD.
2X6 PT WOOD SILL OVER
FOAM GASKET
R-21 MIN. UNFACED BATT
INSULATION, RE: SPEC
UNDER SLAB VAPOR BARRIER,
RE: SPEC.
1/2" EXPANSION JOINT, RE: STRUCT
GRANULAR FILL, RE: STRUCT.
FINISH FLOOR, RE: FINISH
SCHEDULE
CONTINUOUS BEAD OF SEALANT
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
NOTE:
GRAY HATCH INDICATES SYSTEMS
BUILT SCOPE, TYP.9/21/2017 12:41:44 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvtA9.05
FOUNDATION DETAILS
14054.1CHAMONIX - VAILTOWN OF VAIL PERMIT
SET
MAY 31, 2017
1 1/2" = 1'-0"8
FOUNDATION WALL TRANSITION
@ SLAB ON GRADE - GRADE
1 1/2" = 1'-0"1
FOUNDATION WALL TRANSITION
@ SLAB ON GRADE AT GARAGE
1 1/2" = 1'-0" 5 UNIT DEMISING WALL @ SLAB
1 1/2" = 1'-0"9 FOUNDATION @ FOOTING
1 1/2" = 1'-0"2 WINDOW WELL DRAIN
1 1/2" = 1'-0"7 TYP.TRANSITION DETAIL STUCCO/WOOD
1 1/2" = 1'-0"6 DEMISING WALL @ STEPPED SLAB
1 1/2" = 1'-0"3
FOUNDATION WALL TRANSITION
@ SLAB ON GRADE - SIDEWALK
No. Description Date
1 ASI 001 08-28-2017
1
11/15/17
W/D07-A 07-B 07-C 07-D
07-1
07-2
07-3
07-4
A4.01-07/ 2A4.01-07/ 4A4.01-07/ 1
A4.01-07/ 326' - 2 1/2" 26' - 4" 26' - 2 1/2"4' - 0"22' - 11"4' - 0" 30' - 11"78' - 9"
UNIT TYPE 3.1AUNIT TYPE 3.2B
UNIT TYPE 3.1B
13' - 8" 2"
MODULAR BOX DIMENSION STRING
12' - 4" 2" 13' - 8" 2" 13' - 8"
TO FACE OF SHEATHINGMODULAR BOX DIM29' - 0"MODULAR BOX DIM28' - 0"MODULAR BOX DIM29' - 0"MODULAR BOX DIM29' - 0"TO FACE OF SHEATHINGTO FACE OF SHEATHINGTO FACE OF SHEATHINGTO FACE OF SHEATHINGA9.03
6
A9.03
3
A9.03
4
A9.03
2
A9.03
5
07-A 07-B 07-C 07-D
07-1
07-2
07-3
07-4
26' - 2 1/2" 26' - 4" 26' - 2 1/2"4' - 0" 22' - 11"4' - 0" 30' - 11"78' - 9"
A4.01-07/ 2A4.01-07/ 4 A4.01-07/ 1
A4.01-07/ 3 3" / 12" 3" / 12"3" / 12" 3" / 12"
1
A5.01-07
2
A5.02-07
1
A5.02-07
2
A5.01-07
4' - 0" 4' - 0" 4' - 0" 4' - 0"
HATCHED AREA INDICATED 4'-0" OFF
OF DEMISING WALL CENTERLINE,
F.R.P. SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA RIDGEE001
011
015
016
E001 E001
TYP.
3' - 0"TYP.3' - 0"017
017
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/125
- 984 SF / 125 = 7.8 SF W/ 60/40 SPLIT
-PROVIDE 4.8 SF INTAKE W/ (4) GABLE END
VENTS ONE EACH CORNER OF UNIT FRONT
AND BACK. COORDINATE WITH TRUSS AND
INSULATION.
- PROVIDE 3 SF EXHAUST W/ RIDGE VENT
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/125
- 519 SF / 125 = 4.2 SF W/ 60/40 SPLIT
- PROVIDE 2.5 SF INTAKE W/ 1 SF
PERFORATED SOFFIT VENT AND 1.5
SF W/ CONTINUOUS SOFFIT VENT
- PROVIDE 1.8 SF EXHAUST W/ (4)
CAP VENTS
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/125
- 478 SF / 125 = 3.8 SF W/ 60/40 SPLIT
- PROVIDE 2.2 SF INTAKE W/ 1 SF
PERFORATED SOFFIT VENT AND 1.5
SF CONTINUOUS SOFFIT VENT
- PROVIDE 1.5 SF EXHAUST W/
HEADWALL VENT
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/125
- 519 SF / 125 = 4.2 SF W/ 60/40 SPLIT
- PROVIDE 2.5 SF INTAKE W/ 1 SF
PERFORATED SOFFIT VENT AND 1.5
SF W/ CONTINUOUS SOFFIT VENT
- PROVIDE 1.8 SF EXHAUST W/ (4)
CAP VENTS
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/125
- 478 SF / 125 = 3.8 SF W/ 60/40 SPLIT
- PROVIDE 2.2 SF INTAKE W/ 1 SF
PERFORATED SOFFIT VENT AND 1.5
SF CONTINUOUS SOFFIT VENT
- PROVIDE 1.5 SF EXHAUST W/
HEADWALL VENT
3
3
3
HATCHED AREA INDICATES
LOCATIONS OF PERFORATED
SOFFIT VENTS AND CONTINUOUS
SOFFIT VENTS
3
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O.
2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF
STRUCTURE U.N.O.
3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET
4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O.
5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING,
U.N.O.
6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS
BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT.
7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR
DRAWINGS
8. FURNITURE IS SHOWN FOR REFERENCE ONLY
9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE
FLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT
LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL
10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND
FOR DESIGNATIONS OF EXTERIOR MATERIALS.
11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL
SECTIONS
12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW
INFORMATION, SCHEDULES AND DETAILS
13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR
FINISH INFORMATION AND SCHEDULES
14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE
DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY
LOCATED COMMON AREA PER LOCAL CODE
15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD
INSTALLATIONS THAT OCCUR AT SLAB ON GRADE
CONDITIONS
16. ALL EXPOSED CONCRETE FOUNDATION WALLS,
CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR
ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC
17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS
18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O.
19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL
FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING
20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE
THERE IS A GRADE CHANGE OF 30" OR MORE
ROOF PLAN GENERAL NOTES
1. ROOF TYPES ARE AS FOLLOWS:
ROOF TYPE 001: ASPHALT SHINGLE ROOF, 30 YEAR
ROOF TYPE 002: ASHALT SHINGLE ROOF, 30 YEAR
ROOF TYPE 003: STANDING SEAM METAL ROOF
2. ROOF SLOPES ARE MIN. 3/12 FOR ASPHALT SHINGLE AND 1/2
FOR STANDING SEAM, RE: PLAN.
3. ICE AND WATER SHEILD TO BE INSTALLED OVER ENTIRE ROOF
AREA UNDER ASPHALT SHINGLES.. HIGH TEMP ICE AND WATER
SHIELD TO BE INSTALLED OVER ENTIRE ROOF AREA UNDER
STANDING SEAM METAL ROOFS.
4. SNOWGUARDS BASIS OF DESIGN ARE ROCKY MOUNTAIN
SNOWGUARDS, RE: SPEC. SEE PLAN FOR LOCATIONS AND
COORDINATE WITH MFR. FOR TYPICAL SPACING.
4. ROOF DRAWINGS ARE DIAGRAMITC ONLY. REFERENCE
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AND
SPECIFICATIONS FOR SPECIFIC DESIGN INFORMATION.
5. REFERENCE ROOF PLANS FOR LOCATIONS OF REQUIRED FRT
SHEATHING ON EITHER SIDE OF PROPERTY LINE. REFERENCE
DEMISING WALLS DETAILS FOR SPECIFIC INFORMATION.
6. PRE-FINISHED ALUMINUM GUTTERS WITH HEAT TRACE TO BE
PROVIDED ON ALL EAVES AS SHOWN, REFERENCE
ELECTRICAL DRAWINGS FOR POWER LOCAITONS.
1
2
3
4
56 7
8
9
10
KEY PLAN
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
NOTE:
GRAY HATCH INDICATES SYSTEMS
BUILT SCOPE, TYP.9/21/2017 4:28:19 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvtA2.02-07
BUILDING 07 - FLOOR
PLANS
14054.1CHAMONIX - VAILTOWN OF VAIL PERMIT
SET
MAY 31, 2017
3/16" = 1'-0"1 BUILDING 07 - LEVEL 03
3/16" = 1'-0"2 BUILDING 07 - ROOF PLAN
KEYNOTE LEGEND - BUILDING
KEY NOTE
011 SNOW CLEATS, RE: SPEC.
015 DCI PRODUCTS SMARTRIDGE II RIDGE VENT, RE: SPEC.
VERIFY QUANTITY AND LOCATIONS WITH ROOF VENTING
CALCULATIONS.
016 GAF PRODUCTS RT65 SQUARE TOP ROOF LOUVER VENT,
RE:SPEC. VERIFY QUANTITY AND LOCATIONS WITH ROOF
VENTING CALCULATIONS.
017 3'-0" MIN. REQUIRED SETBACK FOR PV ROOF PANELS FROM
EDGE OF ROOF AND RIDGE, TYP. ALL MEP ROOF
PENETRATIONS TO BE INSTALLED OUTSIDE OF THE PV ROOF
PANEL AREA.
E001 RS-1 ASPHALT SHINGLE ROOF, DARK GREY; SEE A0-0 FOR
STANDARD ROOF ASSEMBLIES
No. Description Date
3 ASI 003 09-21-2017
3
11/15/17
CONTINUOUS 2X8 FASCIA TRIM
ICE AND WATER SHIELD, LAP DN
OVER FASCIA
CONTINUOUS 2X FASCIA
CONTINUOUS SUB-FASCIA, RE: STRUCT.
ROOF TRUSS, RE: STRUCT.
HORIZ. STAINED CEDAR SHIP
LAP SIDING, RE: SPEC
7/16" EXTERIOR OSB SHEATHING,
RE: STRUCT.
VENTED
ROOF
2' - 0"
GIRDER TRUSS, RE: STRUCT.
RAINSCREEN SYSTEM LAP DN
OVER DRIP FLASHING, RE: SPEC.
PREMIUM ASHPHALT SHINGLES OVER ICE
AND WATER SHIELD OVER ENTIRE ROOF
OVER OSB SHEATHING, RE: STRUCT.
WRAP ICE AND WATER SHIELD OVER
HEADWALL VENT BLOCKING
DRIP FLASHING OVER PRE-
FINISHED METAL FLASHING
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
PRE-FINISHDED METAL FLASHING
TRUSSED ROOF, RE: STRUCT.
PERFORATED CEMENT BOARD SOFFIT
OVER ATTACHED TO BOTTOM OF
TRUSS, RE: SPEC AND ROOF PLAN
3"
MODULAR BOX MATE WALL
AIR SPACE, RE: PLAN.11 1/4"FULL HEIGHT BLOCKING
BETWEEN TRUSSES, RE:
STRUCT.MIN.2"2" MIN.EXTEND ICE & WATER SHIELD MIN. 1'-0" UP
WALL AND DN OVER HEADWALL VENT
DCI SMARTVENT HEADWALL APPLICATION.
INSTALL OVER FLASHING AND BLOCKING
AND LAYER OF SHINGLES OVER VENT
PRE-FINISHED FLASHING OVER BLOCKING.
3
DCI SMART RIDGE I RIDGE VENT
ASPHALT SHINGLE RIDGE VENT
PREMIUM ASPHALT SHINGLES
BASIS OF DESIGN IS CERTAINTEED
LANDMARK SOLARIS PLATINUM
SHEATHING OVER HIGH-HEEL
TRUSS RE: STRUCTURAL
LAP ICE AND WATER SHIELD INTO
OPENING
ICE AND WATER SHIELD INSTALLED
ON ENTIRE ROOF DECK
PER MFR.
HOLD BACK ROOF SHEATHING EACH
SIDE FULL LENGTH OF RIDGE VENT,
PER MFR. SPECIFICATIONS
EQ EQ
PERFORATED CEMENT BOARD SOFFIT
OVER ATTACHED TO BOTTOM OF
TRUSS, RE: SPEC AND ROOF PLAN
LAP ICE AND WATER SHIELD OVER
PRE-FINISHED MTL FLASHING
CONTINUOUS SUB-FASCIA,
RE: STRUCT.
CONTINUOUS 2X FASCIA
CONTINUOUS 2X8 FASCIA TRIM
ROOF TRUSS RE: STRUCT
VENTED
ROOF
TRUSSED ROOF, RE: STRUCT.
RAINSCREEN SYSTEM LAP DN
OVER DRIP FLASHING, RE: SPEC.
ROOF SHEATHING, RE: STRUCT.
DRIP FLASHING OVER SIDEWALL
STEP FLASHING
EXTEND ICE & WATER SHIELD MIN.
1'-0" UP WALL AND DN OVER
HEADWALL VENT
1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION OVER
7/16" EXT. SHEATHING, RE: SPEC.
HORZ. STAINED CEDAR SHIP
LAP SIDING, RE: SPEC
INSULATION BAFFLE, 2" MIN.
SPACE
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
(1) LAYER 5/8" GYP BD.
SPRAY FOAM INSULATION,
R-21 MIN.
RIGID INSULATION TO TOP OF
PERIMETER 2X PLATE
(2) 2X6 SILL PLATE
2X10 RIM JOISTHEEL HEIGHT1' - 0"11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER
STRIPPED IN ICE AND WATER SHIELD
5/8" GYP BD. OVER 7/16" OSB
SHEATHING
OSB COMPRESSION STRIPS
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE
AND 8" IN ATTIC SPACE
2' - 0"MIN
.2"
FULL HEIGHT BLOCKING BETWEEN
TRUSSES, RE: STRUCT.2" MIN.PREMIUM ASHPHALT SHINGLES OVER ICE
AND WATER SHIELD OVER ENTIRE ROOF
OVER OSB SHEATHING, RE: STRUCT.
WRAP ICE AND WATER SHIELD OVER
HEADWALL VENT BLOCKING
DCI SMARTVENT HEADWALL
APPLICATION. INSTALL OVER
FLASHING AND BLOCKING AND
LAYER OF SHINGLES OVER VENT
PRE-FINISHED FLASHING OVER BLOCKING.
GIRDER TRUSS, RE: STRUCT.
MODULAR BOX MATE WALL
AIR SPACE, RE: PLAN.
3
HORZ. SHIP LAP SIDING OVER
PRE-FINISHED MTL. FLASHING
OVER RAINSCREEN SYSTEM
HIGH TEMP ICE SHIELD
WATERPROOFING OVER
SHEATHING, LAP UP WALL
PER MFR. SPECS.
PRE-FINISHED STANDING SEAM
METAL ROOF LAP UP UNDER
FLASHING AND OVER SPLICE IN
MEMEBRANE FLASHING
LAP RAINSCREEN DN
OVER FLASHING
6X6 STAINED DF COLUMN BEYOND,
RE: STRUCT.
CEMENT BOARD SOFFIT
TIMBER SCREWS THROUGH 2X12
LEDGER BOARD TOP & BOTTOM
INTO BOX FRAMING @ 48" O.C., RE:
STRUCT.
GABLE ROOF FLASHING
OVER METAL CLEAT
CONT. 2X6 FASCIA TRIM
CONTINUOUS 2X FASCIA OVER
RE: PLAN
RE: PLAN
SEALANT, TYP.
STUCCO J BEAD CLOSER
WALL ASSEMBLY, RE: PLAN
WALL ASSEMBLY, RE: PLAN
LVL RAFTER, RE: STRUCT.1"CEMENT BOARD SOFFIT OVER
RAINSCREEN SYSTEM
FLOOR SYSTEM, RE: SYSTEMS
BUILT MFR.
SPRAY FOAM, RE: SYSTEMS
BUILT MFR.
PACK OUT ENTIRE JOIST SPACE
WITH BATT INSULATION.2" MIN.PERFORATED CEMENT BOARD SOFFIT
ATTACHED TO BOTTOM OF TRUSS, RE:
SPEC AND ROOF PLAN
LAP ICE AND WATER SHIELD OVER
PRE-FINISHED MTL FLASHING
CONTINUOUS SUB-FASCIA,
RE: STRUCT.
CONTINUOUS 2X FASCIA
CONTINUOUS 2X8 FASCIA TRIM
ROOF TRUSS RE: STRUCT
VENTED
ROOF
RAINSCREEN SYSTEM, RE: SPEC.
1" R-5 MIN. FOIL FACED
POLYSTYRENE INSULATION OVER
7/16" EXT. SHEATHING, RE: SPEC.
INSULATION BAFFLE, 2" MIN.
SPACE
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD OVER
ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
(1) LAYER 5/8" GYP BD.
SPRAY FOAM INSULATION,
R-21 MIN.
RIGID INSULATION TO TOP OF
PERIMETER 2X PLATE
(2) 2X6 SILL PLATE
2X10 RIM JOISTHEEL HEIGHT1' - 0"11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER
STRIPPED IN ICE AND WATER SHIELD
5/8" GYP BD. OVER 7/16" OSB
SHEATHING
OSB COMPRESSION STRIPS
EPDM MEMBRANE, RE;
SYSTEMS BUILT MFR
R-49 BATT INSULATION - 8" IN
MODULAR CEILING STRUCTURE
AND 8" IN ATTIC SPACE
2' - 0"MIN
.2"FULL HEIGHT BLOCKING BETWEEN
TRUSSES, RE: STRUCT.
SEALANT, TYP.
STUCCO J BEAD CLOSER
2 COAT STUCCO SYSTEM OVER
GALVANIZED FURRED WIRE
MESH, RE: SPEC
LAP ICE AND WATER SHIELD
OVER COLLAR FLANGE
PREMIUM ASHPHALT SHINGLES
OVER ICE AND WATER SHIELD
OVER ENTIRE ROOF OVER ROOF
SHEATHING, RE: STRUCT.
STRIP IN MEMBRANE FLASHING,
EXTEND 4" MIN. BEYOND COLLAR
FLANGE
ATTACH VENT COLAR FLANGE
TO ROOF SHEATHING PER MFR.
REQUIREMENTS. PROVIDE
NECESSARY SUPPORTS UNDER
DECK AS REQUIRED.
CONT. SEALANT AROUND
VENT COLLAR
VENT COLLAR, RE:
MECH/PLUMBING
MECH/PLUMBING VENT
ROOF PENETRATION, RE:
MECH/PLUMBING
ROOF TRUSS, RE: STRUCT.
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
NOTE:
GRAY HATCH INDICATES SYSTEMS
BUILT SCOPE, TYP.9/21/2017 4:26:21 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvtA9.02
ROOF DETAILS
14054.1CHAMONIX - VAILTOWN OF VAIL PERMIT
SET
MAY 31, 2017
1 1/2" = 1'-0"2 TYP.SHED ROOF EAVE
1 1/2" = 1'-0"5 ROOF RIDGE VENT
1 1/2" = 1'-0"3 TYP.UPPER ROOF EAVE OVER LOW ROOF
1 1/2" = 1'-0"4 TYP.EYEBROW ROOF
No. Description Date
3 ASI 003 09-21-2017
1 1/2" = 1'-0"1 TYP. LOWER ROOF EAVE
1 1/2" = 1'-0"6 TYP.ROOF PENETRATION
3
11/15/17