Loading...
HomeMy WebLinkAboutB17-0072_REV2 Approved plans_1510762566.pdfBuilding 7 - Foundation Details 2015-453.001 05/30/17 S5.01-07CHAMONIX - VAIL.TOWN OF VAIL PERMIT SET DISCIPLINE STAMP PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. TOWN STAMP CONSULTANT DRAWN BY: CHECKED BY:3/1/2017 2:04:54 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvt118 West Sixth Street, Suite 200 Glenwood Springs, CO 81601 970.945.1004 www.sgm-inc.com JJP MN Town of Vail Permit Set 2 Demising Wall Revisions 9/21/2017 09/21/17 provide fire rated assem bly type 11/15/17 MIN.6"2 COAT STUCCO SYSTEM OVER GALVANIZED FURRED WIRE MESH, RE: SPEC RAINSCREEN SYSTEM LAP DN OVER METAL DRIP FLASHING, RE: SPEC 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION, RE: SPEC STUCCO J BEAD CLOSER TUFF-N-DRI FOUNDATION DRAINAGE SYSTEM - PROTECTION BOARD OVER DRAINAGE MATT OVER RIGID INSULATION, RE: SPEC. T.O. CONC. @ LEVEL 1 2" INSULATION BOARD 4" CONC. SLAB, RE: STRUCT. CONC. FOUNDATION WALL, RE: STRUCT. 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR PRE-FINISHED METAL FLASHING 5/8" GYP. BD. 2X6 PT WOOD SILL OVER FOAM GASKET R-21 MIN. UNFACED BATT INSULATION, RE: SPEC UNDER SLAB VAPOR BARRIER, RE: SPEC. 1/2" EXPANSION JOINT, RE: STRUCT NUDO WRAP - GROUND BREAKER, RE: SPEC. FLUID APPLIED MEMBRANE AIR BARRIER, RE: SPEC. GRANULAR FILL, RE: STRUCT. FINISH FLOOR, RE: FINISH SCHEDULE CONTINUOUS BEAD OF SEALANT GARAGE T.O. CONC. FIBEROUS EXPANSION MATERIAL, RE: CIVIL EXTERIOR WALL BEYOND. RE. PLAN TUFF-N-DRI FOUNDATION DRAINAGE SYSTEM - PROTECTION BOARD OVER DRAINAGE MATT OVER RIGID INSULATION, RE: SPEC. CONC. FOUNDATION WALL, RE: STRUCT. 4" ASPHALT DRIVEWAY OVER OVER GRANULAR FILL, RE: CIVIL. FLUID APPLIED MEMBRANE AIR BARRIER, RE: SPEC. CONC. SLAB @ GARAGE DOOR OPENING, RE: STRUCT. UNDER SLAB VAPOR BARRIER, RE: SPEC. GRANULAR FILL, RE: STRUCT. SEALED CONC. GARAGE FLOOR, RE: FINISH SCHEDULE 2" INSULATION BOARD NOTE: DETAILS DO NOT REFLECT ALL FINISH CONDITIONS - SEE PLANS AND FINISH PLANS FOR BUILDING MATERIALS NOTE: SEE STRUCUTRAL DETAILS FOR INFORMATION REGARDING DIMENSIONS, ETC. 4" CONCRETE SLAB OVER 10 MIL VAPOR BARRIER OVER 2" RIGIDN INSULATION OVER GRANULAR FILL, RE: STRUCT. UNIT DEMISING WALL, RE: PLAN AND PARTITION TYPES A0.01 FOR WALL TYPE 2X6 PT SILL SILL PLATES OVER FOAM GASKET W/ ANCHOR BOLTS, RE: STRUCT FINISH FLOOR, RE: PLAN AND FINISH SCHEDULE CONTINUOUS BEAD OF SEALANT FILTER FABRIC PERFORATED DRAIN PIPE - PERIMETER DRAIN RE: CIVIL FURRING WALL W/ MIN. R-13 UNFACED BATT INSULATION @ FINISHED SPACE, RE: PLAN TUFF-N-DRI FOUNDATION DRAINAGE SYSTEM - PROTECTION BOARD OVER DRAINAGE MATT OVER RIGID INSULATION, RE: SPEC. CONC. FOUNDATION WALL, RE: STRUCT. FLUID APPLIED MEMBRANE AIR BARRIER, RE: SPEC. 2" INSULATION BOARD 4" CONC. SLAB, RE: STRUCT. 2X4 PT WOOD SILL OVER FOAM GASKET UNDER SLAB VAPOR BARRIER, RE: SPEC. GRANULAR FILL, RE: STRUCT. FINISH FLOOR, RE: FINISH SCHEDULE 1/2" 1/2" EXPANSION JOINT, RE: STRUCT. T.O. CONC. @ LEVEL 1 PERIMETER DRAIN RE: CIVIL 6" MIN.WINDOW PER SCHEDULE, RE: SPEC. PVC PIPE DISCHARGED ONTO GRAVEL, RE: CIVIL 2" INSULATION BOARD 4" CONC. SLAB, RE: STRUCT. 5/8" GYP. BD. 2X4 PT WOOD SILL OVER FOAM GASKET R-13 MIN. UNFACED BATT INSULATION, RE: SPEC UNDER SLAB VAPOR BARRIER, RE: SPEC. 1/2" EXPANSION JOINT, RE: STRUCT GRANULAR FILL, RE: STRUCT. FINISH FLOOR, RE: FINISH SCHEDULE LOOSE GRAVEL, RE: CIVIL WINDOW WELL DRAIN, RE: CIVIL WINDOW WELL RE: SPEC: 7/8" BACKER ROD AND SEALANT PRE-FINISHED METAL FLASHING NUDO WRAP - GROUND BREAKER, RE: SPEC TUFF-N-DRI FOUNDATION DRAINAGE SYSTEM - PROTECTION BOARD OVER DRAINAGE MATT OVER RIGID INSULATION, RE: SPEC. FLUID APPLIED MEMBRANE AIR BARRIER, RE: SPEC CONC. FOUNDATION WALL, RE: STRUCT. PT 2X BLOCKING 5/4" PAINTED WOOD TRIM RE: FINISH SCHEDULE RAINSCREEN SYSTEM, RE: SPEC. 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR. 2X6 SILL PLATE 5/4" x 4" STAINED CEDAR TRIM, RE: SPEC. STUCCO J BEAD CLOSER BACKER ROD AND SEALANT 2 COAT STUCCO SYSTEM OVER GALVANIZED FURRED WIRE MESH, RE: SPEC 1 1/2" R-7.5 MIN. POLYSTYRENE INSULATION, RE: SPEC.3"1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION, RE: SPEC. 1'X4" BASE TRIM, RE: FINISH SCHEDULE 5/8" GYP. BD.HORZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC (2) 2X12 RIM JOISTS SPRAY FOAM INSULATION, R-21 MIN. (2) 2X6 SILL PLATES PREFINISHED METAL FLASHING 5/8" GYP. BD. CONC. FOUNDATION WALL, RE: STRUCT. 7/8" T&G PLYWOOD SHEATHING, RE: SYSTEMS BUILT MFR. NOTE: DETAILS DO NOT REFLECT ALL FINISH CONDITIONS - SEE PLANS AND FINISH PLANS FOR BUILDING MATERIALS NOTE: SEE STRUCUTRAL DETAILS FOR INFORMATION REGARDING DIMENSIONS, ETC. 4" CONCRETE SLAB OVER 10 MIL VAPOR BARRIER OVER 2" RIGID INSULATION OVER GRANULAR FILL, RE: STRUCT. UNIT DEMISING WALL, RE: PLAN AND PARTITION TYPES A0.01 FOR WALL TYPE 2X6 PT SILL SILL PLATES OVER FOAM GASKET W/ ANCHOR BOLTS, RE: STRUCT CONTINUOUS BEAD OF SEALANT FINISH FLOOR, RE: PLAN AND FINISH SCHEDULE SLAB SLOPEVARIES WITH1"2 COAT STUCCO SYSTEM OVER GALVANIZED FURRED WIRE MESH, RE: SPEC RAINSCREEN SYSTEM LAP DN OVER METAL DRIP FLASHING, RE: SPEC 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION, RE: SPEC STUCCO J BEAD CLOSER TUFF-N-DRI FOUNDATION DRAINAGE SYSTEM - PROTECTION BOARD OVER DRAINAGE MATT OVER RIGID INSULATION, RE: SPEC. T.O. CONC. @ LEVEL 1 CONC. FOUNDATION WALL, RE: STRUCT. 7/16" EXTERIOR OSB SHEATHING, RE: SYSTEMS BUILT MFR PRE-FINISHED METAL FLASHING 4" CONC. ENTRY PATIO OVER GRANULAR FILL, RE: STRUCT. FLUID APPLIED MEMBRANE AIR BARRIER, RE: SPEC. 2" INSULATION BOARD 4" CONC. SLAB, RE: STRUCT. 5/8" GYP. BD. 2X6 PT WOOD SILL OVER FOAM GASKET R-21 MIN. UNFACED BATT INSULATION, RE: SPEC UNDER SLAB VAPOR BARRIER, RE: SPEC. 1/2" EXPANSION JOINT, RE: STRUCT GRANULAR FILL, RE: STRUCT. FINISH FLOOR, RE: FINISH SCHEDULE CONTINUOUS BEAD OF SEALANT PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP NOTE: GRAY HATCH INDICATES SYSTEMS BUILT SCOPE, TYP.9/21/2017 12:41:44 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvtA9.05 FOUNDATION DETAILS 14054.1CHAMONIX - VAILTOWN OF VAIL PERMIT SET MAY 31, 2017 1 1/2" = 1'-0"8 FOUNDATION WALL TRANSITION @ SLAB ON GRADE - GRADE 1 1/2" = 1'-0"1 FOUNDATION WALL TRANSITION @ SLAB ON GRADE AT GARAGE 1 1/2" = 1'-0" 5 UNIT DEMISING WALL @ SLAB 1 1/2" = 1'-0"9 FOUNDATION @ FOOTING 1 1/2" = 1'-0"2 WINDOW WELL DRAIN 1 1/2" = 1'-0"7 TYP.TRANSITION DETAIL STUCCO/WOOD 1 1/2" = 1'-0"6 DEMISING WALL @ STEPPED SLAB 1 1/2" = 1'-0"3 FOUNDATION WALL TRANSITION @ SLAB ON GRADE - SIDEWALK No. Description Date 1 ASI 001 08-28-2017 1 11/15/17 W/D07-A 07-B 07-C 07-D 07-1 07-2 07-3 07-4 A4.01-07/ 2A4.01-07/ 4A4.01-07/ 1 A4.01-07/ 326' - 2 1/2" 26' - 4" 26' - 2 1/2"4' - 0"22' - 11"4' - 0" 30' - 11"78' - 9" UNIT TYPE 3.1AUNIT TYPE 3.2B UNIT TYPE 3.1B 13' - 8" 2" MODULAR BOX DIMENSION STRING 12' - 4" 2" 13' - 8" 2" 13' - 8" TO FACE OF SHEATHINGMODULAR BOX DIM29' - 0"MODULAR BOX DIM28' - 0"MODULAR BOX DIM29' - 0"MODULAR BOX DIM29' - 0"TO FACE OF SHEATHINGTO FACE OF SHEATHINGTO FACE OF SHEATHINGTO FACE OF SHEATHINGA9.03 6 A9.03 3 A9.03 4 A9.03 2 A9.03 5 07-A 07-B 07-C 07-D 07-1 07-2 07-3 07-4 26' - 2 1/2" 26' - 4" 26' - 2 1/2"4' - 0" 22' - 11"4' - 0" 30' - 11"78' - 9" A4.01-07/ 2A4.01-07/ 4 A4.01-07/ 1 A4.01-07/ 3 3" / 12" 3" / 12"3" / 12" 3" / 12" 1 A5.01-07 2 A5.02-07 1 A5.02-07 2 A5.01-07 4' - 0" 4' - 0" 4' - 0" 4' - 0" HATCHED AREA INDICATED 4'-0" OFF OF DEMISING WALL CENTERLINE, F.R.P. SHEATHING REQUIRED IN ROOF ASSEMBLY FOR THIS AREA RIDGEE001 011 015 016 E001 E001 TYP. 3' - 0"TYP.3' - 0"017 017 ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/125 - 984 SF / 125 = 7.8 SF W/ 60/40 SPLIT -PROVIDE 4.8 SF INTAKE W/ (4) GABLE END VENTS ONE EACH CORNER OF UNIT FRONT AND BACK. COORDINATE WITH TRUSS AND INSULATION. - PROVIDE 3 SF EXHAUST W/ RIDGE VENT ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/125 - 519 SF / 125 = 4.2 SF W/ 60/40 SPLIT - PROVIDE 2.5 SF INTAKE W/ 1 SF PERFORATED SOFFIT VENT AND 1.5 SF W/ CONTINUOUS SOFFIT VENT - PROVIDE 1.8 SF EXHAUST W/ (4) CAP VENTS ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/125 - 478 SF / 125 = 3.8 SF W/ 60/40 SPLIT - PROVIDE 2.2 SF INTAKE W/ 1 SF PERFORATED SOFFIT VENT AND 1.5 SF CONTINUOUS SOFFIT VENT - PROVIDE 1.5 SF EXHAUST W/ HEADWALL VENT ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/125 - 519 SF / 125 = 4.2 SF W/ 60/40 SPLIT - PROVIDE 2.5 SF INTAKE W/ 1 SF PERFORATED SOFFIT VENT AND 1.5 SF W/ CONTINUOUS SOFFIT VENT - PROVIDE 1.8 SF EXHAUST W/ (4) CAP VENTS ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/125 - 478 SF / 125 = 3.8 SF W/ 60/40 SPLIT - PROVIDE 2.2 SF INTAKE W/ 1 SF PERFORATED SOFFIT VENT AND 1.5 SF CONTINUOUS SOFFIT VENT - PROVIDE 1.5 SF EXHAUST W/ HEADWALL VENT 3 3 3 HATCHED AREA INDICATES LOCATIONS OF PERFORATED SOFFIT VENTS AND CONTINUOUS SOFFIT VENTS 3 FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O. 2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF STRUCTURE U.N.O. 3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET 4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O. 5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING, U.N.O. 6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT. 7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR DRAWINGS 8. FURNITURE IS SHOWN FOR REFERENCE ONLY 9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE FLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL 10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND FOR DESIGNATIONS OF EXTERIOR MATERIALS. 11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL SECTIONS 12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW INFORMATION, SCHEDULES AND DETAILS 13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR FINISH INFORMATION AND SCHEDULES 14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY LOCATED COMMON AREA PER LOCAL CODE 15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD INSTALLATIONS THAT OCCUR AT SLAB ON GRADE CONDITIONS 16. ALL EXPOSED CONCRETE FOUNDATION WALLS, CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC 17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS 18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O. 19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING 20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE THERE IS A GRADE CHANGE OF 30" OR MORE ROOF PLAN GENERAL NOTES 1. ROOF TYPES ARE AS FOLLOWS: ROOF TYPE 001: ASPHALT SHINGLE ROOF, 30 YEAR ROOF TYPE 002: ASHALT SHINGLE ROOF, 30 YEAR ROOF TYPE 003: STANDING SEAM METAL ROOF 2. ROOF SLOPES ARE MIN. 3/12 FOR ASPHALT SHINGLE AND 1/2 FOR STANDING SEAM, RE: PLAN. 3. ICE AND WATER SHEILD TO BE INSTALLED OVER ENTIRE ROOF AREA UNDER ASPHALT SHINGLES.. HIGH TEMP ICE AND WATER SHIELD TO BE INSTALLED OVER ENTIRE ROOF AREA UNDER STANDING SEAM METAL ROOFS. 4. SNOWGUARDS BASIS OF DESIGN ARE ROCKY MOUNTAIN SNOWGUARDS, RE: SPEC. SEE PLAN FOR LOCATIONS AND COORDINATE WITH MFR. FOR TYPICAL SPACING. 4. ROOF DRAWINGS ARE DIAGRAMITC ONLY. REFERENCE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AND SPECIFICATIONS FOR SPECIFIC DESIGN INFORMATION. 5. REFERENCE ROOF PLANS FOR LOCATIONS OF REQUIRED FRT SHEATHING ON EITHER SIDE OF PROPERTY LINE. REFERENCE DEMISING WALLS DETAILS FOR SPECIFIC INFORMATION. 6. PRE-FINISHED ALUMINUM GUTTERS WITH HEAT TRACE TO BE PROVIDED ON ALL EAVES AS SHOWN, REFERENCE ELECTRICAL DRAWINGS FOR POWER LOCAITONS. 1 2 3 4 56 7 8 9 10 KEY PLAN PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP NOTE: GRAY HATCH INDICATES SYSTEMS BUILT SCOPE, TYP.9/21/2017 4:28:19 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvtA2.02-07 BUILDING 07 - FLOOR PLANS 14054.1CHAMONIX - VAILTOWN OF VAIL PERMIT SET MAY 31, 2017 3/16" = 1'-0"1 BUILDING 07 - LEVEL 03 3/16" = 1'-0"2 BUILDING 07 - ROOF PLAN KEYNOTE LEGEND - BUILDING KEY NOTE 011 SNOW CLEATS, RE: SPEC. 015 DCI PRODUCTS SMARTRIDGE II RIDGE VENT, RE: SPEC. VERIFY QUANTITY AND LOCATIONS WITH ROOF VENTING CALCULATIONS. 016 GAF PRODUCTS RT65 SQUARE TOP ROOF LOUVER VENT, RE:SPEC. VERIFY QUANTITY AND LOCATIONS WITH ROOF VENTING CALCULATIONS. 017 3'-0" MIN. REQUIRED SETBACK FOR PV ROOF PANELS FROM EDGE OF ROOF AND RIDGE, TYP. ALL MEP ROOF PENETRATIONS TO BE INSTALLED OUTSIDE OF THE PV ROOF PANEL AREA. E001 RS-1 ASPHALT SHINGLE ROOF, DARK GREY; SEE A0-0 FOR STANDARD ROOF ASSEMBLIES No. Description Date 3 ASI 003 09-21-2017 3 11/15/17 CONTINUOUS 2X8 FASCIA TRIM ICE AND WATER SHIELD, LAP DN OVER FASCIA CONTINUOUS 2X FASCIA CONTINUOUS SUB-FASCIA, RE: STRUCT. ROOF TRUSS, RE: STRUCT. HORIZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC 7/16" EXTERIOR OSB SHEATHING, RE: STRUCT. VENTED ROOF 2' - 0" GIRDER TRUSS, RE: STRUCT. RAINSCREEN SYSTEM LAP DN OVER DRIP FLASHING, RE: SPEC. PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER OSB SHEATHING, RE: STRUCT. WRAP ICE AND WATER SHIELD OVER HEADWALL VENT BLOCKING DRIP FLASHING OVER PRE- FINISHED METAL FLASHING PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. PRE-FINISHDED METAL FLASHING TRUSSED ROOF, RE: STRUCT. PERFORATED CEMENT BOARD SOFFIT OVER ATTACHED TO BOTTOM OF TRUSS, RE: SPEC AND ROOF PLAN 3" MODULAR BOX MATE WALL AIR SPACE, RE: PLAN.11 1/4"FULL HEIGHT BLOCKING BETWEEN TRUSSES, RE: STRUCT.MIN.2"2" MIN.EXTEND ICE & WATER SHIELD MIN. 1'-0" UP WALL AND DN OVER HEADWALL VENT DCI SMARTVENT HEADWALL APPLICATION. INSTALL OVER FLASHING AND BLOCKING AND LAYER OF SHINGLES OVER VENT PRE-FINISHED FLASHING OVER BLOCKING. 3 DCI SMART RIDGE I RIDGE VENT ASPHALT SHINGLE RIDGE VENT PREMIUM ASPHALT SHINGLES BASIS OF DESIGN IS CERTAINTEED LANDMARK SOLARIS PLATINUM SHEATHING OVER HIGH-HEEL TRUSS RE: STRUCTURAL LAP ICE AND WATER SHIELD INTO OPENING ICE AND WATER SHIELD INSTALLED ON ENTIRE ROOF DECK PER MFR. HOLD BACK ROOF SHEATHING EACH SIDE FULL LENGTH OF RIDGE VENT, PER MFR. SPECIFICATIONS EQ EQ PERFORATED CEMENT BOARD SOFFIT OVER ATTACHED TO BOTTOM OF TRUSS, RE: SPEC AND ROOF PLAN LAP ICE AND WATER SHIELD OVER PRE-FINISHED MTL FLASHING CONTINUOUS SUB-FASCIA, RE: STRUCT. CONTINUOUS 2X FASCIA CONTINUOUS 2X8 FASCIA TRIM ROOF TRUSS RE: STRUCT VENTED ROOF TRUSSED ROOF, RE: STRUCT. RAINSCREEN SYSTEM LAP DN OVER DRIP FLASHING, RE: SPEC. ROOF SHEATHING, RE: STRUCT. DRIP FLASHING OVER SIDEWALL STEP FLASHING EXTEND ICE & WATER SHIELD MIN. 1'-0" UP WALL AND DN OVER HEADWALL VENT 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION OVER 7/16" EXT. SHEATHING, RE: SPEC. HORZ. STAINED CEDAR SHIP LAP SIDING, RE: SPEC INSULATION BAFFLE, 2" MIN. SPACE PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. (1) LAYER 5/8" GYP BD. SPRAY FOAM INSULATION, R-21 MIN. RIGID INSULATION TO TOP OF PERIMETER 2X PLATE (2) 2X6 SILL PLATE 2X10 RIM JOISTHEEL HEIGHT1' - 0"11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER STRIPPED IN ICE AND WATER SHIELD 5/8" GYP BD. OVER 7/16" OSB SHEATHING OSB COMPRESSION STRIPS EPDM MEMBRANE, RE; SYSTEMS BUILT MFR R-49 BATT INSULATION - 8" IN MODULAR CEILING STRUCTURE AND 8" IN ATTIC SPACE 2' - 0"MIN .2" FULL HEIGHT BLOCKING BETWEEN TRUSSES, RE: STRUCT.2" MIN.PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER OSB SHEATHING, RE: STRUCT. WRAP ICE AND WATER SHIELD OVER HEADWALL VENT BLOCKING DCI SMARTVENT HEADWALL APPLICATION. INSTALL OVER FLASHING AND BLOCKING AND LAYER OF SHINGLES OVER VENT PRE-FINISHED FLASHING OVER BLOCKING. GIRDER TRUSS, RE: STRUCT. MODULAR BOX MATE WALL AIR SPACE, RE: PLAN. 3 HORZ. SHIP LAP SIDING OVER PRE-FINISHED MTL. FLASHING OVER RAINSCREEN SYSTEM HIGH TEMP ICE SHIELD WATERPROOFING OVER SHEATHING, LAP UP WALL PER MFR. SPECS. PRE-FINISHED STANDING SEAM METAL ROOF LAP UP UNDER FLASHING AND OVER SPLICE IN MEMEBRANE FLASHING LAP RAINSCREEN DN OVER FLASHING 6X6 STAINED DF COLUMN BEYOND, RE: STRUCT. CEMENT BOARD SOFFIT TIMBER SCREWS THROUGH 2X12 LEDGER BOARD TOP & BOTTOM INTO BOX FRAMING @ 48" O.C., RE: STRUCT. GABLE ROOF FLASHING OVER METAL CLEAT CONT. 2X6 FASCIA TRIM CONTINUOUS 2X FASCIA OVER RE: PLAN RE: PLAN SEALANT, TYP. STUCCO J BEAD CLOSER WALL ASSEMBLY, RE: PLAN WALL ASSEMBLY, RE: PLAN LVL RAFTER, RE: STRUCT.1"CEMENT BOARD SOFFIT OVER RAINSCREEN SYSTEM FLOOR SYSTEM, RE: SYSTEMS BUILT MFR. SPRAY FOAM, RE: SYSTEMS BUILT MFR. PACK OUT ENTIRE JOIST SPACE WITH BATT INSULATION.2" MIN.PERFORATED CEMENT BOARD SOFFIT ATTACHED TO BOTTOM OF TRUSS, RE: SPEC AND ROOF PLAN LAP ICE AND WATER SHIELD OVER PRE-FINISHED MTL FLASHING CONTINUOUS SUB-FASCIA, RE: STRUCT. CONTINUOUS 2X FASCIA CONTINUOUS 2X8 FASCIA TRIM ROOF TRUSS RE: STRUCT VENTED ROOF RAINSCREEN SYSTEM, RE: SPEC. 1" R-5 MIN. FOIL FACED POLYSTYRENE INSULATION OVER 7/16" EXT. SHEATHING, RE: SPEC. INSULATION BAFFLE, 2" MIN. SPACE PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. (1) LAYER 5/8" GYP BD. SPRAY FOAM INSULATION, R-21 MIN. RIGID INSULATION TO TOP OF PERIMETER 2X PLATE (2) 2X6 SILL PLATE 2X10 RIM JOISTHEEL HEIGHT1' - 0"11 1/4" PRE-FINISHED MTL DRIP FLASHING OVER STRIPPED IN ICE AND WATER SHIELD 5/8" GYP BD. OVER 7/16" OSB SHEATHING OSB COMPRESSION STRIPS EPDM MEMBRANE, RE; SYSTEMS BUILT MFR R-49 BATT INSULATION - 8" IN MODULAR CEILING STRUCTURE AND 8" IN ATTIC SPACE 2' - 0"MIN .2"FULL HEIGHT BLOCKING BETWEEN TRUSSES, RE: STRUCT. SEALANT, TYP. STUCCO J BEAD CLOSER 2 COAT STUCCO SYSTEM OVER GALVANIZED FURRED WIRE MESH, RE: SPEC LAP ICE AND WATER SHIELD OVER COLLAR FLANGE PREMIUM ASHPHALT SHINGLES OVER ICE AND WATER SHIELD OVER ENTIRE ROOF OVER ROOF SHEATHING, RE: STRUCT. STRIP IN MEMBRANE FLASHING, EXTEND 4" MIN. BEYOND COLLAR FLANGE ATTACH VENT COLAR FLANGE TO ROOF SHEATHING PER MFR. REQUIREMENTS. PROVIDE NECESSARY SUPPORTS UNDER DECK AS REQUIRED. CONT. SEALANT AROUND VENT COLLAR VENT COLLAR, RE: MECH/PLUMBING MECH/PLUMBING VENT ROOF PENETRATION, RE: MECH/PLUMBING ROOF TRUSS, RE: STRUCT. PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP NOTE: GRAY HATCH INDICATES SYSTEMS BUILT SCOPE, TYP.9/21/2017 4:26:21 PM C:\Users\rwilberger\Documents\CHAMONIX_Building Models_rwilberger.rvtA9.02 ROOF DETAILS 14054.1CHAMONIX - VAILTOWN OF VAIL PERMIT SET MAY 31, 2017 1 1/2" = 1'-0"2 TYP.SHED ROOF EAVE 1 1/2" = 1'-0"5 ROOF RIDGE VENT 1 1/2" = 1'-0"3 TYP.UPPER ROOF EAVE OVER LOW ROOF 1 1/2" = 1'-0"4 TYP.EYEBROW ROOF No. Description Date 3 ASI 003 09-21-2017 1 1/2" = 1'-0"1 TYP. LOWER ROOF EAVE 1 1/2" = 1'-0"6 TYP.ROOF PENETRATION 3 11/15/17