HomeMy WebLinkAboutB17-0074_A2-02-09_1498503102.pdfW
D
09-A 09-B 09-C 09-D
09-1
09-3
09-4
09-5
09-6
09-2
A4.01-09/ 2
A4.01-09/ 3
A4.01-09/ 1 A4.01-09/ 4
26' - 2 1/2" 28' - 1" 26' - 2 1/2"
3' - 0"
1' - 0" 25' - 11" 1' - 0" 1' - 0" 31' - 11"
80' - 6"
UNIT TYPE 3.1A
UNIT TYPE 3L.2A
UNIT TYPE 3.1B
1
A5.01-09
2
A5.01-09
1
A5.02-09
2
A5.02-09
13' - 8" 2"
MODULAR BOX DIMENSION STRING
12' - 1" 2" 15' - 8" 2" 13' - 8"
TO FACE OF SHEATHING
MODULAR BOX DIM
29' - 0"
MODULAR BOX DIM
32' - 0"
MODULAR BOX DIM
33' - 0"
MODULAR BOX DIM
29' - 0"
TO FACE OF SHEATHING
TO FACE OF SHEATHING
TO FACE OF SHEATHING
TO FACE OF SHEATHING
09-A 09-B 09-C 09-D
09-1
09-3
09-4
09-5
26' - 2 1/2" 28' - 1" 26' - 2 1/2"
3' - 0"
1' - 0" 25' - 11" 1' - 0" 1' - 0" 31' - 11"
80' - 6"
09-6
09-2
A4.01-09/ 2 A4.01-09/ 3
A4.01-09/ 1 A4.01-09/ 4
3" / 12" 3" / 12" 3" / 12" 4" / 12"
4" / 12" 3" / 12"
3" / 12"
3" / 12" 3" / 12" 3" / 12"
1
A5.01-09
2
A5.01-09
1
A5.02-09
2
A5.02-09
HATCHED AREA INDICATED 4'-0" OFF
OF DEMISING WALL CENTERLINE,
F.R.P. SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA
SNOW CLEATS, TYP.
RIDGE
RIDGE
4" / 12" 4" / 12" PITCH BREAK
PITCH BREAK
E016
E016
E016
E025E025
E001E001
E001
E025E025
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/150
- 1026 SF / 150 = 7.5 SF
- PROVIDE 3.75 SF SOFFIT AND
GABLE END INTAKE AND 3.75
SF RIDGE VENT EXHAUST
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/150
- 533 SF / 150 = 3.5 SF
- PROVIDE 1.75 SF SOFFIT INTAKE
AND 1.75 SF CAP VENT EXHAUST
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/150
- 478 SF / 150 = 3 SF
- PROVIDE 1.5 SF SOFFIT INTAKE
AND 1.5 SF HEADWALL VENT
EXHAUST
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/150
- 519 SF / 150 = 3.5 SF
- PROVIDE 1.75 SF SOFFIT INTAKE
AND 1.75 SF CAP VENT EXHAUST
ROOF VENTING IRC 1203.2
- NET FREE VENT AREA 1/150
- 478 SF / 150 = 3 SF
- PROVIDE 1.5 SF SOFFIT INTAKE
AND 1.5 SF HEADWALL VENT
EXHAUST
E001
E002
E001
E001
E001
016
015
E001
E001
E001
E001
FLOOR PLAN GENERAL NOTES
1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O.
2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF
STRUCTURE U.N.O.
3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET
4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O.
5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING,
U.N.O.
6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS
BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT.
7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR
DRAWINGS
8. FURNITURE IS SHOWN FOR REFERENCE ONLY
9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE
FLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT
LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL
10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND
FOR DESIGNATIONS OF EXTERIOR MATERIALS.
11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL
SECTIONS
12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW
INFORMATION, SCHEDULES AND DETAILS
13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR
FINISH INFORMATION AND SCHEDULES
14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE
DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY
LOCATED COMMON AREA PER LOCAL CODE
15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD
INSTALLATIONS THAT OCCUR AT SLAB ON GRADE
CONDITIONS
16. ALL EXPOSED CONCRETE FOUNDATION WALLS,
CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR
ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC
17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS
18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O.
19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL
FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING
20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE
THERE IS A GRADE CHANGE OF 30" OR MORE
ROOF PLAN GENERAL NOTES
1. ROOF TYPES ARE AS FOLLOWS:
ROOF TYPE 001: ASPHALT SHINGLE ROOF, 30 YEAR
ROOF TYPE 002: ASHALT SHINGLE ROOF, 30 YEAR
ROOF TYPE 003: STANDING SEAM METAL ROOF
2. ROOF SLOPES ARE MIN. 3/12 FOR ASPHALT SHINGLE AND 1/2
FOR STANDING SEAM, RE: PLAN.
3. ICE AND WATER SHEILD TO BE INSTALLED OVER ENTIRE ROOF
AREA UNDER ASPHALT SHINGLES.. HIGH TEMP ICE AND WATER
SHIELD TO BE INSTALLED OVER ENTIRE ROOF AREA UNDER
STANDING SEAM METAL ROOFS.
4. SNOWGUARDS BASIS OF DESIGN ARE ROCKY MOUNTAIN
SNOWGUARDS, RE: SPEC. SEE PLAN FOR LOCATIONS AND
COORDINATE WITH MFR. FOR TYPICAL SPACING.
4. ROOF DRAWINGS ARE DIAGRAMITC ONLY. REFERENCE
MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AND
SPECIFICATIONS FOR SPECIFIC DESIGN INFORMATION.
5. REFERENCE ROOF PLANS FOR LOCATIONS OF REQUIRED FRT
SHEATHING ON EITHER SIDE OF PROPERTY LINE. REFERENCE
DEMISING WALLS DETAILS FOR SPECIFIC INFORMATION.
6. PRE-FINISHED ALUMINUM GUTTERS WITH HEAT TRACE TO BE
PROVIDED ON ALL EAVES AS SHOWN, REFERENCE
ELECTRICAL DRAWINGS FOR POWER LOCAITONS.
1
2
3
4
5
6 7
8
9
10
KEY PLAN
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
NOTE:
GRAY HATCH INDICATES SYSTEMS
BUILT SCOPE, TYP.
6/1/2017
2:35:01 PM C:\Revit
Local\CHAMONIX_Building
Models_joecoleman6.rvt
A2.02-09
BUILDING 09 - FLOOR
PLANS
14054.1
CHAMONIX - VAIL
TOWN OF VAIL PERMIT
SET
MAY 31, 2017
3/16" = 1'-0"
1 BUILDING 09 - LEVEL 03
3/16" = 1'-0"
2 BUILDING 09 - ROOF PLAN
KEYNOTE LEGEND - BUILDING
KEY NOTE
015 DCI PRODUCTS SMARTRIDGE II RIDGE VENT, RE: SPEC.
VERIFY QUANTITY AND LOCATIONS WITH ROOF VENTING
CALCULATIONS.
016 GAF PRODUCTS RT65 SQUARE TOP ROOF LOUVER VENT,
RE:SPEC. VERIFY QUANTITY AND LOCATIONS WITH ROOF
VENTING CALCULATIONS.
E001 RS-1 ASPHALT SHINGLE ROOF, DARK GREY; SEE A0-0 FOR
STANDARD ROOF ASSEMBLIES
E002 RS-2 STANDING SEAM ROOF, LIGHT GREY; SEE A0-0 FOR
STANDARD ROOF ASSEMBLIES
E016 PRE-FINISHED METAL GUTTER AND DOWNSPOUT, TO MATCH
ROOF FASCIA; RE: SPEC
E025 RS-1 ASPHALT SHINGLE ROOF, LIGHT GRAY; SEE A0-0 FOR
STANDARD ROOF ASSEMBLIES
No. Description Date
06/26/17