Loading...
HomeMy WebLinkAboutB17-0074_A2-02-09_1498503102.pdfW D 09-A 09-B 09-C 09-D 09-1 09-3 09-4 09-5 09-6 09-2 A4.01-09/ 2 A4.01-09/ 3 A4.01-09/ 1 A4.01-09/ 4 26' - 2 1/2" 28' - 1" 26' - 2 1/2" 3' - 0" 1' - 0" 25' - 11" 1' - 0" 1' - 0" 31' - 11" 80' - 6" UNIT TYPE 3.1A UNIT TYPE 3L.2A UNIT TYPE 3.1B 1 A5.01-09 2 A5.01-09 1 A5.02-09 2 A5.02-09 13' - 8" 2" MODULAR BOX DIMENSION STRING 12' - 1" 2" 15' - 8" 2" 13' - 8" TO FACE OF SHEATHING MODULAR BOX DIM 29' - 0" MODULAR BOX DIM 32' - 0" MODULAR BOX DIM 33' - 0" MODULAR BOX DIM 29' - 0" TO FACE OF SHEATHING TO FACE OF SHEATHING TO FACE OF SHEATHING TO FACE OF SHEATHING 09-A 09-B 09-C 09-D 09-1 09-3 09-4 09-5 26' - 2 1/2" 28' - 1" 26' - 2 1/2" 3' - 0" 1' - 0" 25' - 11" 1' - 0" 1' - 0" 31' - 11" 80' - 6" 09-6 09-2 A4.01-09/ 2 A4.01-09/ 3 A4.01-09/ 1 A4.01-09/ 4 3" / 12" 3" / 12" 3" / 12" 4" / 12" 4" / 12" 3" / 12" 3" / 12" 3" / 12" 3" / 12" 3" / 12" 1 A5.01-09 2 A5.01-09 1 A5.02-09 2 A5.02-09 HATCHED AREA INDICATED 4'-0" OFF OF DEMISING WALL CENTERLINE, F.R.P. SHEATHING REQUIRED IN ROOF ASSEMBLY FOR THIS AREA SNOW CLEATS, TYP. RIDGE RIDGE 4" / 12" 4" / 12" PITCH BREAK PITCH BREAK E016 E016 E016 E025E025 E001E001 E001 E025E025 ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/150 - 1026 SF / 150 = 7.5 SF - PROVIDE 3.75 SF SOFFIT AND GABLE END INTAKE AND 3.75 SF RIDGE VENT EXHAUST ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/150 - 533 SF / 150 = 3.5 SF - PROVIDE 1.75 SF SOFFIT INTAKE AND 1.75 SF CAP VENT EXHAUST ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/150 - 478 SF / 150 = 3 SF - PROVIDE 1.5 SF SOFFIT INTAKE AND 1.5 SF HEADWALL VENT EXHAUST ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/150 - 519 SF / 150 = 3.5 SF - PROVIDE 1.75 SF SOFFIT INTAKE AND 1.75 SF CAP VENT EXHAUST ROOF VENTING IRC 1203.2 - NET FREE VENT AREA 1/150 - 478 SF / 150 = 3 SF - PROVIDE 1.5 SF SOFFIT INTAKE AND 1.5 SF HEADWALL VENT EXHAUST E001 E002 E001 E001 E001 016 015 E001 E001 E001 E001 FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O. 2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF STRUCTURE U.N.O. 3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET 4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O. 5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING, U.N.O. 6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT. 7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR DRAWINGS 8. FURNITURE IS SHOWN FOR REFERENCE ONLY 9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE FLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL 10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND FOR DESIGNATIONS OF EXTERIOR MATERIALS. 11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL SECTIONS 12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW INFORMATION, SCHEDULES AND DETAILS 13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR FINISH INFORMATION AND SCHEDULES 14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY LOCATED COMMON AREA PER LOCAL CODE 15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD INSTALLATIONS THAT OCCUR AT SLAB ON GRADE CONDITIONS 16. ALL EXPOSED CONCRETE FOUNDATION WALLS, CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC 17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS 18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O. 19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING 20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE THERE IS A GRADE CHANGE OF 30" OR MORE ROOF PLAN GENERAL NOTES 1. ROOF TYPES ARE AS FOLLOWS: ROOF TYPE 001: ASPHALT SHINGLE ROOF, 30 YEAR ROOF TYPE 002: ASHALT SHINGLE ROOF, 30 YEAR ROOF TYPE 003: STANDING SEAM METAL ROOF 2. ROOF SLOPES ARE MIN. 3/12 FOR ASPHALT SHINGLE AND 1/2 FOR STANDING SEAM, RE: PLAN. 3. ICE AND WATER SHEILD TO BE INSTALLED OVER ENTIRE ROOF AREA UNDER ASPHALT SHINGLES.. HIGH TEMP ICE AND WATER SHIELD TO BE INSTALLED OVER ENTIRE ROOF AREA UNDER STANDING SEAM METAL ROOFS. 4. SNOWGUARDS BASIS OF DESIGN ARE ROCKY MOUNTAIN SNOWGUARDS, RE: SPEC. SEE PLAN FOR LOCATIONS AND COORDINATE WITH MFR. FOR TYPICAL SPACING. 4. ROOF DRAWINGS ARE DIAGRAMITC ONLY. REFERENCE MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS AND SPECIFICATIONS FOR SPECIFIC DESIGN INFORMATION. 5. REFERENCE ROOF PLANS FOR LOCATIONS OF REQUIRED FRT SHEATHING ON EITHER SIDE OF PROPERTY LINE. REFERENCE DEMISING WALLS DETAILS FOR SPECIFIC INFORMATION. 6. PRE-FINISHED ALUMINUM GUTTERS WITH HEAT TRACE TO BE PROVIDED ON ALL EAVES AS SHOWN, REFERENCE ELECTRICAL DRAWINGS FOR POWER LOCAITONS. 1 2 3 4 5 6 7 8 9 10 KEY PLAN PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP NOTE: GRAY HATCH INDICATES SYSTEMS BUILT SCOPE, TYP. 6/1/2017 2:35:01 PM C:\Revit Local\CHAMONIX_Building Models_joecoleman6.rvt A2.02-09 BUILDING 09 - FLOOR PLANS 14054.1 CHAMONIX - VAIL TOWN OF VAIL PERMIT SET MAY 31, 2017 3/16" = 1'-0" 1 BUILDING 09 - LEVEL 03 3/16" = 1'-0" 2 BUILDING 09 - ROOF PLAN KEYNOTE LEGEND - BUILDING KEY NOTE 015 DCI PRODUCTS SMARTRIDGE II RIDGE VENT, RE: SPEC. VERIFY QUANTITY AND LOCATIONS WITH ROOF VENTING CALCULATIONS. 016 GAF PRODUCTS RT65 SQUARE TOP ROOF LOUVER VENT, RE:SPEC. VERIFY QUANTITY AND LOCATIONS WITH ROOF VENTING CALCULATIONS. E001 RS-1 ASPHALT SHINGLE ROOF, DARK GREY; SEE A0-0 FOR STANDARD ROOF ASSEMBLIES E002 RS-2 STANDING SEAM ROOF, LIGHT GREY; SEE A0-0 FOR STANDARD ROOF ASSEMBLIES E016 PRE-FINISHED METAL GUTTER AND DOWNSPOUT, TO MATCH ROOF FASCIA; RE: SPEC E025 RS-1 ASPHALT SHINGLE ROOF, LIGHT GRAY; SEE A0-0 FOR STANDARD ROOF ASSEMBLIES No. Description Date 06/26/17