Loading...
HomeMy WebLinkAboutChamonix Air Infiltration Testing Report - Unit 19.pdf NORTPENFRGY formerly ACTIVE ENERGIES— Chamonix Development - Building 9, Unit 19 Air Infiltration Report Test Date: February 7, 2018 III [ Builder: RA Nelson re Contact: Jason Kiefer Site Address: 2373 Chamonix Road, Vail, CO 81657 Site Visit By: Jason Weingast Background The project goal is to undergo testing at the final point in construction to determine if the unit meets the 2015 IECC requirements for infiltration. Active Energies was contracted to perform a final blower door test to determine total air infiltration. The home is permitted under the Town of Vail and requires blower door testing per the IECC. The blower door testing must show a tested value of 3 ACH50 or lower in order to comply with the IECC. Site Observations Construction of the building envelope was complete. All exterior openings were shut and locked and interior doors were open. The ERV serves the unit continuously, so it was covered over per ICC guidelines to eliminate this infiltration. The blower door test was performed in the back patio door to the unit. The pressure probe was placed outside. Blower Door Test The unit was depressurized, utilizing blower door testing equipment to a pressure of-50 Pa. At the test pressure, the CFM50 was recorded, in order to determine the ACH5o. The blower door air leakage resulted in the following measurements: 3.0ACHso Please call with any questions or concerns. \*A\ Jason Weingast LEED for Homes Green Rater, HERS Rater NORTH 39 ENERGY/Active Energies, Inc. Expert Energy Consulting, Training &Verification Services Page 1 of 1 2/10/2018 P.O.Box 1434,Edwards,CO 81632 P: 970.306.4237