Loading...
HomeMy WebLinkAboutB17-0075_A2-02-10_1495580100.pdfW D W D 10-A 10-B 10-C 10-D 10-1 10-2 10-3 10-4 10-E A4.01-10/ 2 A4.01-10/ 3 A4.01-10/ 1 A4.01-10/ 4 2 A5.01-10 26' - 2 1/2" 28' - 1" 28' - 1" 26' - 2 1/2" 3' - 0" 26' - 11" 2' - 0" 31' - 11" 108' - 7" UNIT TYPE 3.1A UNIT TYPE 3L.2A UNIT TYPE 3.1B UNIT TYPE 3L.2B 1 A5.01-10 A1/ 3 1 A5.02-10 2 A5.02-10 10-A 10-B 10-C 10-D 10-1 10-2 10-3 10-4 10-E 26' - 2 1/2" 28' - 1" 28' - 1" 26' - 2 1/2" 3' - 0" 26' - 11" 2' - 0" 31' - 11" 108' - 7" A4.01-10/ 2 A4.01-10/ 3 A4.01-10/ 1 A4.01-10/ 4 2 A5.01-10 3" / 12" 4" / 12" 4" / 12" 3" / 12" 3" / 12" 3" / 12" 3" / 12" 3" / 12" 3" / 12" 4" / 12" 4" / 12" 3" / 12" 3" / 12" 3" / 12" 3" / 12" 1 A5.01-10 A1/ 3 1 A5.02-10 2 A5.02-10 HATCHED AREA INDICATED 4'-0" OFF OF DEMISING WALL CENTERLINE, F.R.P. SHEATHING REQUIRED IN ROOF ASSEMBLY FOR THIS AREA 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0" SNOW CLEATS, TYP. FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O. 2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF STRUCTURE U.N.O. 3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET 4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O. 5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING, U.N.O. 6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT. 7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR DRAWINGS 8. FURNITURE IS SHOWN FOR REFERENCE ONLY 9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE FLOOR PLAN, REFLECTED CEILING PLAN AND FINISH PLANS FOR EACH UNIT AND LEVEL 10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND FOR DESIGNATIONS OF EXTERIOR MATERIALS. 11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL SECTIONS 12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW INFORMATION, SCHEDULES AND DETAILS 13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR FINISH INFORMATION AND SCHEDULES 14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY LOCATED COMMON AREA PER LOCAL CODE 15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD INSTALLATIONS THAT OCCUR AT SLAB ON GRADE CONDITIONS 16. ALL EXPOSED CONCRETE FOUNDATION WALLS, CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC 17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS 18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O. 19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING 20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE THERE IS A GRADE CHANGE OF 30" OR MORE ROOF PLAN GENERAL NOTES 1. ROOF TYPES ARE AS FOLLOWS: ROOF TYPE 1: ASPHALT SHINGLE ROOF, 30 YEAR ROOF TYPE 2: STANDING SEAM METAL ROOF 2. ALL ROOFING SURFACES TO SLOPE 1/4" VERTICAL PER 1' - 0" HORIZONTAL MINIMUM, U.N.O. 3. TOP OF INSULATION HEIGHTS, HIGH POINTS AND LOW POINTS, ARE INDICATED AS THE TOP OF ROOF SURFACE ABOVE THE ROOF DRAIN(S). (I.E. + 3.5" WHERE HIGH POINT OF ROOF DRAIN SUMP IS +0" 4. REFER TO SHEET A5.02 FOR TYPICAL ROOF DETAILS. 5. ALL ROOF TOP MECHANICAL, ELECTRICAL AND/OR PLUMBING EQUIPMENT SHOWN FOR INFORMATION ONLY. REFERENCE MECHANICAL, ELECTRICAL AND PLUMBING DOCUMENTS AND SPECIFICATIONS FOR SPECIFIC DESIGN INFORMATION. 6. ICE DAM BARRIER OF AT LEAST TWO LAYERS OF UNDERLAYMENT CEMENTED TOGETHER OR OF A SELF- ADHERING POLYMER MODIFIED BITUMEN SHEET SHALL EXTEND FROM THE ROOF EAVE EDGE AT LEAST SIX FEET INSIDE THE EXTERIOR WALL LINE AS MEASURED ALONG THE ROOF SURFACE, EIGHTEEN INCHES FROM THE CENTERLINE OF THE VALLEY AND UP TWENTY-FOUR INCHES ON THE VERTICAL WALL AT A ROOF AND WALL JUNCTURE. (ORDINANCE 31, 2001, PG 13) R905.2.7.1 ICE BARRIER 1 2 3 4 5 6 7 8 9 10 KEY PLAN PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP FOR REFERENCE ONLY 4/26/2017 10:57:37 AM C:\Users\lfrazier\Documents\CHAMONIX_Building Models_lfrazier.rvt A2.02-10 BUILDING 10 - FLOOR PLANS 14054.1 CHAMONIX - VAIL FOUNDATION PERMIT APRIL 26, 2017 3/16" = 1'-0" 1 BUILDING 10 - LEVEL 03 3/16" = 1'-0" 2 BUILDING 10 - ROOF PLAN No. Description Date 05/23/17