Loading...
HomeMy WebLinkAboutB17-0075_A3-03-10_1498503319.pdfDN HOLD 3' - 1" HOLD 3' - 1" EQ 7' - 6" EQ 4' - 0" 1' - 10 3/4" 3' - 9 3/4" 2' - 0" 2' - 8" 3' - 8 3/4" 4' - 7" C L K 3.1-201 3.1-203 3.1-202 12 A6.03 MASTER BEDROOM CLOSET MASTER BATH CLOSET HALLWAY 13 A6.03 ALIGN 3' - 8 3/4" 2' - 6" A6.03/ 5 A6.03/ 1 E1 H 6' - 0" 3' - 3 5/8" A1 A1 WS-3 WS-3 WS-3 WS-4 WS-3 WS-3 WS-3 HOLD 3' - 1" VERIFY W/ PL 5' - 0" 1 A5.01-10 2 A5.02-10 MASTER BEDROOM CLOSET MASTER BATH HALLWAY CLOSET EQ EQ EQ EQ EQ EQ EQ EQ EQ 5' - 0" EQ 2' - 2" 1' - 6" EQ EQ EQ EQ EQ EQ 1' - 8" 6' - 0" EQ EQ WR EQ EQ 002 MASTER BEDROOM CLOSET CLOSET MASTER BATH HALLWAY CPT-01 CPT-01 T-02 CPT-01 T-02 PL-02 PL-03 PL-04 PL-04 LIGHTING LEGEND 6" RECESSED LIGHT EXTERIOR WALL LAMP CEILING FAN W/ LIGHT BATHROOM CEILING FAN J JUNCTION BOX 4.8" PENDENT LIGHT 18" DRUMB PENDANT VANITY WALL LIGHT 1' X 4' FLOURESCENT LIGHT FLUSH MOUNT CEILING LIGHT GARAGE DOOR OPERATOR FINISH PLAN GENERAL NOTES 1. REFER TO SHEET A3.01 FOR FINISH SCHEDULE 2. ALL WALLS TO BE P-01, EGGSHELL. ALL TRIM TO BE P-02, EGGSHELL. ALL CEILINGS TO BE P-02, FLAT. 3. ALL WALL BASE TO HAVE MITERED EDGES. 4. EQ-05 & EQ-06 WASHER AND DRYER ARE SIDE-BY-SIDE OR STABKABLE UNITS. REFER TO PLANS FOR INSTALL TYPE. REFLECTED CEILING NOTES: 1. NOTIFY ARCHITECT OF DISCREPANCY UPON DISCOVERY PRIOR TO PROCEEDING WITH SAID WORK. 2. ALL CEILING SHALL BE 9'-0" A.F.F, UNLESS NOTED OTHERWISE. 3. REFER TO FIRE PROTECTION DRAWINGS FOR LOCATION OF SPRINKLER HEADS. CENTER FIRE SPRINKLER HEADS BOTH DIRECTIONS IN CEILING TILES. ALL CORRIDOR SPRINKLER HEADS SHALL BE ALIGNED AND CENTERED IN SAID SPACE. 4. SUBMIT LAYOUT OF ALL GYPSUM BOARD CEILING CONTROL JOINTS FOR REVIEW. 5. MINOR DISCREPANCIES BETWEEN MEP AND ARCHITECTURAL DOCUMENTS IN REGARD TO LOCATION OF CEILING MOUNTED COMPONENTS, ARCHITECTURAL REFLECTED CEILING PLAN SHALL GOVERN. 6. RE: MECHANICAL AND ELECTRICAL DRAWINGS FOR MOUNTING LOCATIONS OF ITEMS WHERE NO CEILING IS REQUIRED OR INDICATED. 7. IN ALL MECHANICAL/BOILER ROOMS; CONTINUE PARTITION, WALL ASSEMBLY TO STRUCTURE OR BOTTOM OF CEILING WITH FIRE STOPS AS REQUIRED IN INTERSTICIAL SPACE. SEAL ALL JOINTS PER SYSTEM. PROVIDE FIRE SEALANT AT ALL PENETRATIONS AND HEADS OF WALL 8. CEILINGS ABOVE SHOWERS/BATHS WILL RECIEVE MOISTURE RESISTANT GYP. BD., TYPE 'X' 9. PENDANT LIGHTS ABOVE KITCHEN BAR TO BE SET 2'-6" ABOVE COUNTER HEIGHT. PRE-MARK AND VERIFY ALL LOCATIONS W/ INTERIORS. 10. PROVIDE BATT INSULATION IN ALL FLOORS, CEILING AND WALLS SURROUNDING BATH/SHOWER, MECHANICAL AND WASHER/DRYER ROOMS/CLOSETS. 11. CENTER ALL CEILING GRIDS IN EACH ROOM OR SPACE UNLESS OTHERWISE INDICATED WITH A GRID ORIGIN OR DIMENSION. 12. ACCESS DOOR LOCATIONS IN GYPSUM BOARD CEILINGS ARE INDICATED WHERE ARCHITECTURALLY SIGNIFICANT. 13. SPRINKLER SPRINKLER TO BE DESIGNED BY FIRE PROTECTION ENGINEER. COORDINATE ALL LOCATIONS WITH ARCHITECT. 14. ALL LIGHT FIXTURES IN MECH, CLOSETS AND LAUNDRY SHOULD BE CENTERED IN ROOM IN BOTH DIRECTIONS, UNO. FLOOR PLAN GENERAL NOTES 1. ALL DIMENSIONS ARE TAKEN FROM FACE OF STUD, U.N.O. 2. ALL GRIDLINES ALIGN WITH FACE OF STUD OR FACE OF STRUCTURE U.N.O. 3. KEYNOTES ARE SPECIFIC TO EACH DRAWING SHEET 4. ALL INTERIOR WALL PARTITION TYPES ARE 'TYPE A1' U.N.O. 5. ALL EXTERIOR WALLS ARE 2X6, WITH 7/16" OSB SHEATHING, U.N.O. 6. FLOOR AND CEILING FRAMING SYSTEMS PER SYSTEMS BUILT MFR. STANDARDS TO BE REVIEWED BY ARCHITECT. 7. ALL CLOSETS TO INCLUDE SHELF & ROD RE: INTERIOR DRAWINGS 8. FURNITURE IS SHOWN FOR REFERENCE ONLY 9. REFER TO THE A3 SERIES FOR UNIT PLANS, WHICH INCLUDE FLOOR PLAN, REFLECTED CEILING PLAN, EQUIPMENT LOCATIONS AND FINISH PLANS FOR EACH UNIT AND LEVEL 10. REFER TO THE A4 SERIES FOR EXTERIOR ELEVATIONS AND FOR DESIGNATIONS OF EXTERIOR MATERIALS. 11. REFER TO THE A5 SERIES FOR ALL BUILDING AND WALL SECTIONS 12. REFER TO THE A8 SERIES FOR DOOR AND WINDOW INFORMATION, SCHEDULES AND DETAILS 13. REFER TO FINISH PLANS AND INTERIOR ELEVATIONS FOR FINISH INFORMATION AND SCHEDULES 14. ENSURE A HARDWIRED CARBON MONOXIDE AND SMOKE DETECTOR IS INSTALLED ON EACH LEVEL IN A CENTRALLY LOCATED COMMON AREA PER LOCAL CODE 15. FLOOR LEVELING MAY BE REQUIRED FOR TILE AND WOOD INSTALLATIONS THAT OCCUR AT SLAB ON GRADE CONDITIONS 16. ALL EXPOSED CONCRETE FOUNDATION WALLS, CRAWLSPACES, AND FLOORS EXPOSED TO THE EXTERIOR ARE REQUIRED TO BE INSULATED PER THE 2015 IRC/IECC 17. USE 5/8" TYPE 'X' GYPSUM BOARD ON ALL GARAGE CEILINGS 18. ALL CEILINGS TO BE GYPSUM WALL BOARD U.N.O. 19. COORDINATE LOCATIONS FOR ACCESS DOORS WITH ALL FINAL MECHANCIAL EQUIPMENT AND FLOOR/ROOF FRAMING 20. GUARDRAILS ARE REQUIRED AT ALL LOCATIONS WHERE THERE IS A GRADE CHANGE OF 30" OR MORE PROJECT NUMBER ISSUE DATE REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN TOWN STAMP DISCIPLINE STAMP NOTE: GRAY HATCH INDICATES SYSTEMS BUILT SCOPE, TYP. 6/1/2017 2:26:06 PM C:\Revit Local\CHAMONIX_Building Models_joecoleman6.rvt A3.03-10 BUILDING 10 - UNIT 3.1 B - LEVEL 03 14054.1 CHAMONIX - VAIL TOWN OF VAIL PERMIT SET MAY 31, 2017 1/4" = 1'-0" 1 UNIT 3.1 B - LEVEL 03 - FLOOR PLAN 1/4" = 1'-0" 2 UNIT 3.1 B - LEVEL 03 - RCP 1/4" = 1'-0" 3 UNIT 3.1 B - LEVEL 03 - FINISH PLAN KEYNOTE LEGEND - GENERAL KEY NOTE 002 22"X30" ACCESS PANEL; RE: SPECS. No. Description Date 06/26/17