HomeMy WebLinkAboutB17-0075_G0-01-10_1498503332.pdf1 HR RATING THIS
SECTION OF WALL
NOTE: ALL GARAGE CEILINGS
ARE REQUIRED TO HAVE 5/8"
TYPE 'X' GYPSUM BOARD
1 HR RATING WITH
SPRINKLER REDUCTION
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING WITH
SPRINKLER REDUCTION
1 HR RATING THIS
SECTION OF WALL
1 HR RATING THIS
SECTION OF WALL
1 HR RATING WITH
SPRINKLER REDUCTION
HATCHED AREA INDICATES 1 HR
RATING 4'-0" OFF OF DEMISING WALL
CENTERLINE. FRT SHEATHING
REQUIRED IN ROOF ASSEMBLY FOR
THIS AREA
PARTITION LEGEND
1 HR BARRIER
(RATED 1HR FROM
EACH SIDE)
2 HR BARRIER
(RATED 2HR FROM
EACH SIDE)
REFERENCE A0.01 FOR WALL TYPES
5/8" TYPE "X" GYP. BD.
LEVEL 1
100' - 0"
LEVEL 2
111' - 0"
10-A 10-B 10-C 10-D 10-E
LEVEL 3
122' - 0"
LEVEL 4
133' - 0"
2 CAR GARAGE
1 CAR GARAGE LAUNDRY ENTRY
KITCHEN
MASTER
BEDROOM
1 CAR GARAGE
LAUNDRY ENTRY
MECH KITCHEN KITCHEN
KITCHEN
2 CAR GARAGE
MASTER
BEDROOM
BEDROOM
BEDROOM
MECH
ENTRY ENTRY
MASTER BATH
MASTER BATH MASTER
BEDROOM
MASTER
BEDROOM
1 HR HORIZONTAL RATING 4'-0" EITHER
SIDE OF DEMISING WALL CENTERLINE.
FRT SHEATHING REQUIRED IN ROOF
ASSEMBLY FOR THIS AREA
TYPICAL 1 HR VERTICAL UNIT
DEMISING WALL RATING WITH
SPRINKLER REDUCTION
A9.04
3
A9.04
3
A9.04
1 SIM.
A9.04
3
A9.04
3
A9.04
1 SIM.
A9.04
3
A9.04
3
A9.04
1
5/8" TYPE "X" GYP BD AT ALL GARAGE
WALLS AND CEILINGS ADJACENT TO OR
UNDER FINISHED SPACE AND AT
STRUCTRUAL STEEL BEAM SOFFITS.
PROJECT NUMBER
ISSUE DATE
REVISION
SHEET TITLE
ISSUE
SHEET NO.
KEY PLAN
TOWN STAMP
DISCIPLINE STAMP
6/1/2017
2:27:16 PM C:\Revit
Local\CHAMONIX_Building
Models_joecoleman6.rvt
G0.01-10
CODE STUDY
14054.1
CHAMONIX - VAIL
TOWN OF VAIL PERMIT
SET
MAY 31,
2017
1/16" = 1'-0"
1 LEVEL 01
1/16" = 1'-0"
2 LEVEL 02
1/16" = 1'-0"
3 LEVEL 03
1/16" = 1'-0"
4 ROOF
1/8" = 1'-0"
5 CODE SECTION 1-10
No. Description Date
06/26/17