Loading...
HomeMy WebLinkAboutB17-0114_A-602_1501879560.pdf z Of 7 -61j,iQ0711 08/04/17 WINDOW SCHEDULE WINDOW AREA EXTERIOR DOOR SCHEDULE DOOR AREA SIZE APPROXIMATE U- JAMB SIZE (INCHES) SIZE APPROXIMATE JAMB SIZE (INCHES) MARK OPERATION TYPE EGRESS TEMP. STC RATING VALUE GLAZING DEPTH NOTES MARK MARK HANDING TEMP. STC RATING U-VALUE GLAZING DEPTH NOTES MARK Width Height Width Height SQUARE FEET Width Height Width Height SQUARE FEET 101 3'-0" 4'-4" CASEMENT EGRESS --- 0.33 101 36 52 13.00 A 3'-6" 8'-7 3/4" RH TEMP. 40 0.33 ENTRY- MULLED TO WINDOWS 106, 107 A 42 103.75 30.26 102 3'-6" 2'-0" AWNING --- --- 0.33 102 42 24 7.00 B 3'-0" 8'-0" RH TEMP. 0.25 TRIPLE BUNK ROOM - MULLED TO WINDOW 313 B 36 96 24.00 103 3'-0" 2'-0" FIXED/SASH 0.33 MULLED TO 104 103 36 24 6.00 C 3'-0" 8'-0" LH TEMP. 0.25 TRIPLE DEN / FAMILY C 36 96 24.00 104 3'-0" 2'-0" FIXED/SASH 0.33 MULLED TO 103 AND 105 104 36 24 6.00 D 3'-0" 7'-0" RH TEMP. 40 0.33 LOFT BEDROOM D 36 84 21.00 105 3'-0" 2'-0" FIXED/SASH --- --- 0.33 MULLED TO 104 105 36 24 6.00 TOTAL 99.26 _ NOTES: 106 3'-0" 8'-5 3/4" FIXED/DIRECT SET --- TEMP. 40 0.33 MULLED TO 107 AND (DOOR A) 106 36 101.75 25.44 1.ALL WINDOWS AND EXTERIOR DOORS TO BE WOOD FRAMED WITH ALUMINUM CLADDING UNLESS OTHERWISE NOTED. 107 6'-7 3/4" 2'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 106 AND (DOOR A) 107 109.75 24 18.29 2. EXTERIOR DOORS TO BE SAME MANUFACTURER AS WINDOWS. 201 3'-0" 5'-0" CASEMENT --- --- 40 0.33 --- 201 36 60 15.00 202 NOT USED 202 203 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 204 203 84 60 35.00 204 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 203, 205 204 84 60 35.00 205 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 204 205 84 60 35.00 206 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 207 206 84 60 35.00 207 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 206 207 84 60 35.00n I • n 208 3'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 209 208 36 60 15.00 ARCHITECTS 209 3'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 209 209 36 60 15.00 210 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 208 210 84 60 35.00 65 NORTH 4TH STREET, SUITE 5 211 3'-0" 5'-0" FIXED/DIRECT SET 0.25 TRIPLE 211 36 60 15.00 CARBONDALE, CO 81623 212 3'-0" 5'-0" CASEMENT EGRESS 0.25 TRIPLE --- 212 36 60 15.00 TEL. 910.963.6689 213 3'-0" 5'-0" FIXED/DIRECT SET TEMP. Y2\ 0.25 TRIPLE 213 36 60 15.00 IU UU.C3REENLINEARCHITECTS.COM 301 3'-6" 2'-0" FIXED/DIRECT SET --- 40 0.33 --- 301 43 24 7.17 302 3'-6" 2'-0" FIXED/DIRECT SET --- --- 40 0.33 --- 302 43 24 7.17 Z 303 3'-6" 2'-0" FIXED/DIRECT SET --- --- 40 0.33 --- 303 43 24 7.17 O 304 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 -- 304 84 60 35.00 /V1- 305 7'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 MULLED TO 206 305 84 60 35.00 0 U 306 3'-0" 5'-0" CASEMENT EGRESS --- 40 0.33 MULLED TO 205 306 36 60 15.00 307 3'-0" 5'-0" FIXED/DIRECT SET --- TEMP. 40 0.33 MULLED TO 308,404 Z 1121 307 36 60 15.00 308 3'-0" 5'-0" FIXED/DIRECT SET TEMP. 40 0.33 MULLED TO 307 308 36 60 15.00 309 3'-0" 5'-0" FIXED/DIRECT SET --- --- 40 0.33 --- 309 36 60 15.00 > c el 310 3'-0" 5'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE --- 310 36 60 15.00 O 311 3'-0" 5'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE --- 311 36 60 15.00 0 0 ' 0 312 3'-6" 2'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULLED TO 313 Z 41 312 42 24 7.00 313 3'-6" 2'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULLED TO 312, DOOR B 313 42 24 7.00 1 11..) ly ty °314 3'-6" 2'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULLED TO 315 6314 42 24 7.00 O 315 3'-6" 2'-0" FIXED/DIRECT SET X 0.25 TRIPLE MULLED TO 314, 316 315 42 24 7.00 O E 0 316 3'-6" 2'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULLED TO 315 316 42 24 7.00 E 401 3'-6" 2'-0" FIXED/DIRECT SET --- --- 40 0.33 --- 401 42 24 7.00 m l�I�i 402 3'-6" 3'-0" FIXED/DIRECT SET --- --- 40 0.33 --- 402 42 36_ 10.50 ly O 403 4'-2" 3'-0" FIXED/DIRECT SET --- --- 40 0.33 --- 403 50 36 12.50 v 14 404 3'-0" 5'-0" FIXED/DIRECT SET --- TEMP. 40 0.33 MULLED TO 307 13 404 36 60 15.00 `ro NI 405 2'-6" 2'-0" FIXED/DIRECT SET --- --- 0.33 --- 405 30 24 5.00 "" 0 406 3'-6" 2'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULLED TO 407, 409 406 24 24 4.00 •- O 407 3'-6" 2'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULED TO 406, 410, 4080 ... .B 407 24 24 4.00 408 3'-6" 2'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULLED TO 407, 411 408 24 24 4.00 III 409 3'-6" 4'-0" AWNING --- --- 0.25 TRIPLE MULLED TO 406, 410 409 48 48 16.00CD ...- 410 3'-6" 4'-0" FIXED/DIRECT SET --- --- 0.25 TRIPLE MULLED TO 409, 407,411 410 48 48 16.00 1- 411 3'-6" 4'-0" AWNING --- --- 0.25 TRIPLE MULLED TO 408, 410 411 48 48 16.00 O NOTES: TOTA, 708.23 6.26.2017 CI IAPJCEJ I IICI ILICI [TED IN CREI 1 1.ALL WINDOWS AND EXTERIOR DOORS TO BE WOOD FRAMED WITH ALUMINUM CLADDING UNLESS OTHERWISE NOTED. 2 EXT RIO' DOnRSTF$ BEA AM, MA UFA TU ER A WI DO A . „ A A A A A A A A A A A A A A A A A A A A A _ A MARK DATE DESCRIPTION 4.18.2017 PERMIT A 6.26.2017 BLDG. DEPT. REV. 1 A 7.17.2017 BLDG. DEPT. REV. 2 .. r ,= 0 p�� E E 4:41.4.co +, E ° WINDOW AND DOOR SCHEDULES a) A 4.... 6e2t .. <72, 6) Please Recycle! 0 as io