Loading...
HomeMy WebLinkAboutB17-0114_C-104_1501879560.pdf 4;;;114* 1.10 z 401 i-4:14 WATER SERVICE LINE NOTES: .eit r71 �� ---- Graphic Scale 1. WATER SERVICE LINE IS TO BE 1" TYPE K COPPER TUBING. 0 5 i oO (9ai17 2. ALL JOINTS SHALL BE BRASS COMPRESSION COUPLINGS OR SILVER SOLDER. NO LEAD JOINTS WILL BE ALLOWED. WARNING TAPE WHITE RIVER NATIONAL FOREST 3 SERVICE LINE MUST USE FULL LENGTH (100 LF FOR 1) OF (SEE NOTE ON THIS SHEET) In Feet: 1" = 10' TUBING BEFORE A SPLICE CAN BE INSTALLED. 12» 4. INSTALL SERVICE LINE SO THAT IT IS FREE OF KINKS, ______________ --____ ---- _ INDENTATION OR OTHER DAMAGE ANY DAMAGED COPPER TUBING --- LOT LINE OR FITTINGS MAY BE REJECTED BY THE EAGLE RIVER WATER & BEDDING MATERIAL IS 12" MIN. - _ _ -,,, ,,,:::::_ _, , SANITATION DISTRICT (ERWSD) INSPECTOR TO BE 3/4" MINUS - _ 5 AN APPROPRIATELY SIZED GOOSENECK SHALL BE MADE IN THE SCREENED ROCK • WATER SERVICE LINE AT THE CORPORATION VALVE TO PREVENT 6" M/N. 1: SECT/ON LINE SERVICE FROM BEING PULLED FROM THE WATER MAIN DURING -_ " BACKFILL AND COMPACTION 1" TYPE K 6. WATER SERVICE LINE SHALL BE BURIED AMINIMUM OF 7' ANDA COPPER TUBING _ T _ _ _ 1 . _ _ �_ _ _ _ _ _ MAXIMUM OF 9.5' BELOW FINISHED GRADE. 4'" M/N - - --- - - - - - - - - 7. UNDERGROUND WARNING TAPE SHALL BE INSTALLED 2' ABOVE -- - - - - - - - - ALL BURIED PORTIONS OF THE WATER SERVICE LINE. THE TAPE 4367 COLUMBINE DR • ' SHALL BE 4 MILLIMETER THICK POLYETHYLENE TAPE, SOLID BLUE 0.27 ACRES • COLOR WITH BLACK LE I lERING, AND 6" IN WIDTH. 8575 (11928 SECTION SF) 8. ALL WATER SERVICE CONNECTIONS SHALL BE MADE ONLY BY --________ ERWSD PERSONNEL USING A TAPPING SADDLE FITTING. WATER SERA/CE LINE DETAIL I 9. REFER TO ERWSD RULES & REGULATIONS FOR FURTHER I• ____L - INSTALLATION DETAILS. SCALE N.T.S. 8520 \ 1-_- ,_., -_,/- �- C - _ WASTEWATER SERVICE LINE NOTES: ._!, '-' _,,,,, , „ , , Mkt%T 1. WASTEWATER SERVICE LINE IS TO BE 4'' C900 PVC PIPE WITH -I - _ INTEGRAL BELL AND SPIGOT JOINTS. - a ;,.' 4 .... 2. WASTEWATER SERVICE LINE SHALL BE INSTALLED AT A CONSTANT WARNING TAPE I 85 0 __ , "" I GRADE OR NOT LESS THAN %4" PER LINEAL FOOT, WITH A (SEE NOTE ON THIS SHEET o �.' _ ::::.:~.1a;,i . MINIMUM OF BENDS AND NO GLUE JOINTS. ) $ 12" - -- 3 CLEAN OUTS SHALL BE INSTALLED EVERY 100 LF AND A BBB' MAXIMUM OF 3' FROM THE FACE OF THE BUILDING. ALL CLEAN � -�__ „' ' l ''''' '''' -,__ OUTS SHALL BE SET IN H-10 TRAFFIC RATED VALVE BOX WITH BEDDING MATERIAL IS 12" MIN. - _ �- COVER. TO BE 3/4" MINUS _ • - ° _ _ _ - , ' ____- IOW: 4387 COLUMBINE DR . „ .„ „ „ . ..,, .. ., „_ „__,,, 4. WASTEWATER SERVICE LINE SHALL BE BURIED A MINIMUM OF 5' SCREENED ROCKIN „„_, I 0.28 ACRES file -- BELOW FINISHED GRADE. 6" MIN. I 4-09--- �� -' , �, „_, , , „, „______ • O ,„ ! (12145 SF) 5 • UNDERGROUND WARN/NG TAPE SHALL BE INSTALLED 2' ABOVE o �0' ALL BURIED PORTIONS OF THE WASTEWATER SERVICE LINE THE 4" C900 / T TAPE SHALL BE 4 MILLIMETER THICK POLYETHYLENE TAPE, SOLID PVC PIPE » 4 M/N. K0 GREEN COLOR WITH BLACK LE I IERING, AND 6 IN WIDTH. ' 6. ALL WASTEWATER SERVICE CONNECTIONS SHALL BE MADE ONLY .? •\ I - ____-__ BY ERWSD PERSONNEL USING A SADDLE CONNECTION. THE FLOW 8500 \�\ /�/y, I LINE OF THE SERVICE PIPE SHALL ENTER THE MAIN ABOVE THE I 41 -y ' SPRING LINE OF THE MA/N. - ---- 7. REFER TO ERWSD RULES & REGULATIONS FOR FURTHER SECTION I '''' <qii- -��- INSTALLATION DETAILS. I }'>___ -8505------------SERI//CE LINE DETAIL O 60 LF 1" TYPE K COPPER WATER SERV/CE, -- SCALE. N.T.S. CLEAN OUT CURB STOP,- ST-UB -OUT- ' _ - TO BE PROVIDED D CAP PER ERWSD 1...........°• O '" WITH/N 3' OF BUILDING _ _ - 60LF1 %2' HDPEGAS i I LINE PER XCEL ENERGY e I • _'_', C___'90......, 06, ® /_ -,:- ,I 60 LF 4 C900 PVC SEWER, STUB - �- OUT & END CAP PER ERWSD ELECTRIC, FIBER OPTIC, & CABLE COMMON TRENCH NOTES. `. ,: %B. ' / `" -'''',e,"_ 1. REFER TO HOLY CROSS ENERGY (HCE), CENTURYLINK, & COMCAST I� (4) 60 LF SCH. 40 PVC CONDUIT & XFIN/TY FOR SPEC/FIC INSTALLATION REQUIREMENTS AND DETAILS. WARNING TAPE -__ •••- -- :: , see ____ 8500---_______ 9 PULL STR/NG FOR ELECTRIC, FO, TEL. > 2. MINIMUM SEPARATION BETWEEN GAS AND ELECTRIC LINES SHALL (SEE NOTE ON THIS SHEET) � � 90 LF 4" C PVCCABLE LINES COMMON TRENCH > Ti0 & (SEE BE 3' / ri` SEWER PER ERWSD DETAIL THIS SHEET) > > / 3. UNDERGROUND WARNING TAPE SHALL BE INSTALLED 2 ABOVE ALL 12 I T _ Lss -___ I _ BURIED PORTIONS OF THE ELECTRIC SERVICE LINE THE TAPE Ltc�u���L I > SHALL BE 4 MILLIMETER THICK POLYETHYLENE TAPE, SOLID RED LLLLLL��� ' > " _ - BEDDING MATER/AL IS TO 84 :. ;4.4._ , L COLOR WITH BLACK LETTERING, AND 6" IN WIDTH. 1 » 12" MIN. '�� �' LLQ. > ___-- - -� L�LLLL. BE /2 MINUS SAND OR LLCtL-L . 4. PULL STRING SHALL BE PROVIDED FOR ALL CONDUITS. � LLLL ------- : APPROVED ON SITE MAT'L •� LLLLLLL � • ) - 84gs > -LLLLLLLL- -"" _ _LLLLLLL _ - - -- _ _ _ - _ " 4" MIN. I'' �� ---------_--"----------- ---- - -- �8' � - ' I '-- CURBS �/ PROVIDE 4" THICKINSULATION OVER- -- "--"--""- ----_-_-_-_-_-_-_----------2::::::::-11::::::,-;-, (3) 4" SCHEDULE 40 PVC ROVID ' , 4» MIN. i --- - --"- > i ��, WATER & SEWER LINES --"- -- ---- _ _____ --- _--____ ©- CONDUITS FOR HCE ELECTRIC, _"" "" STOP _ � -- __ " ___- :=-- - �E -61- - -----" "- 3 � (SEE 1NSULATICTN DETAIL THIS SHEET) " - „W,- _,:,.,,_, ...;:_,- CENTURYLINK FIBER OPTIC, & �' W VU W- w k/ -2-''' �6 COMCAST XF/N/TY CABLE LINES . " - G G- h �0 - `8Q9 __ :----- :_______ , -�' ,6„W, cb SECTION b '" /' E E E E E E E Ep� ' , ' 3 � --= ---------- - - - - ,,6"W rn �I ' s • 8¢8j -. --- --- � "- RATED VALVE BOX CO E --""" - - - - - ,6 LEAN O1JT 10 TRAFf7C SHALLOW UTILITY COMMON TRENCH DETAIL �� _______ - - --6"W J; y '`w I SCALE. N.T.S. :.85" ,/ F ss ----- --- , �', __6"W'- :4 ' - �6 44110r '' 85 ✓ - y "W vi -L INE"PER- Y----------- 120---L-r1; TYPE K C� 7y ®_ ��/',� - - - - \ I , G' COPPER WATER SERVICE F -�� - -6"W I T „W `� /�"- __ LINE PER ERWSD-- I' � _�;'W w _, G \F - - _ ty "W -I5 tilli GAS SERV/CE LINE NOTES: g48o l "_�`11$ - . °� ,6 W ��'6 co.-- _- G _ ' - / FO -------------- 1. XCEL ENERGY INSTALLATION REQUIREMENTS FOR DETAILS. > Is' _ _--""- T-011 ` r -� // _ G_ - G s FO a , (3) 225 LF SCH. 40 PVC CONDUIL___- ----- 2. MINIMUM SEPARATION BETWEEN GAS AND ELECTRIC LINES SHALL WARNING TAPE �/ _ �a c0*-----W : BE 3. (SEE NOTE ON THIS SHEET) --__- & PULL STRING FOR FIBER OPT/C__ _______________ r- I 225 LF SCH. 40 PVC / � 66.0 SY RETE & REPLACE _ G _a ` - - _FO Q 3. UNDERGROUND WARN/NG TAPE SHALL BE INSTALLED 2' ABOVE X�--- - TELEPHONE, & CABLE LINES (SEE CONDUIT & PULL STRING 41.0 LF SAW CUT ; /,r'� �;,.� /� - _ --- E COMMON TRENCH DETAIL THIS SHEET ASPH. FULL DEPTH / // ( _ G ', f_a" ' > c ALL BUR/ED PORTIONS OF THE GAS SERVICENS LINE. THE TAPE ) ________________ ' / ASPH. SEE ASPH. PATCH - / E 012" _-___-_- FOR ELECTRIC LINE PER HCE / �/ - G'- _8"sem ----- SHALL EO ��I ____ ------------ ::::::: SHALL BE 4 MILLIMETER THICK POLYETHYLENE TAPE, SOLID _------"--- ___ --" (TOTAL BOTH SIDES) �or A • A I', 4' DETA/L SHEET G'-501) __ G- A__8"5-- - CONNE l OPTICQ YELLOW COLOR WITH BLACK LETTERING, AND 6" IN W/DTH. 8475 l� III- _g"s-- - - - O/f0."-----*--- - BEDDING MATER/AL IS TO " ----'V'W- _- G _8"s-_ - IX TO EX.CPEDESTAL PER /J' co BE %2" MINUS SAND _-6 ! % s__ _ - COMCAST XFINITY OR CLASS 1 A.B.0 _-6W � I� - G _ s---8' - - - FO�FE� (SEE SHEET C-104) " - - ;" ___ ,, - �; -__6"W� i/� •j�`/', - ra„s_ -g-s J - _ 'F0/-Vs.IS h 6 MIN. - ��T /�� �� - 8470 it __6"w O R w.) �� ///``` - fO�fE�E CONNECT ELECTRIC TO 1 HDPE - 6"W_ ' - I > > E�/ 1ni6 / 4u � 0'� HOLY CROSS ENERGY 4» MIN. i _ - �� BINE D - _ G`'r: �l� r� FO/E > (SEE SHEET C-104) �'- - STORM /�6 C�LVIVI _-' G __a',/'% f.�� 'FO�E� SECTION DR4/N IV-E- _ _ "s--_gs E GAS SERVICE LINE DETAIL -- G- -a"S_ - - �' o....-----c E....... > SCALE: N.T.S. 6�� G G- 0-8"S-'1- - 1 • ca. CONNECT NEW SEWER SERVICE - G`;---�� - - - y s" > > TO EX SEWER LINE. INSTALL \ co - G-- G �! - - - y v$ FULL BODY WYE W/ SOLID Li _ G__ ;G--- G • ,co '•, - - __ 1.- ��' > ...... SLEEVE BY ERWSD PERSONNEL c G- T- - z (2 TYP.) 3 -,y - - -��6\ /���� ....-----"- a > ...... LOT 12 - - �' > ..... CONNECT NEW GAS SERVICE TO \ in% �`O '5� GAS MAIN BY XCEL PERSONNEL N / ,V (2 TYP.) \ a PROPOSED 18" EQUIVALENT REMAINDER LOT 11 0 ELLIPTICAL CULVERT m ....\..„„,.............. CONNECT NEW WATER SERVICE TO EX WATER LINE. INSTALL TAP W/ CORP. STOP 6" MIN. BY ERWSD PERSONNEL \ o, 4" OF POLYSTYRENE UTILITY NOTES: ` (2 TYP.) \ 1 INSULATION (LOCATED ALONG II 1. ALL UTILITY LOCATIONS ARE APPROXIMATE. CONTRACTOR TO FIELD ::,2,.. `SIDES AND ON TOP OF PIPE) 6'" M/N VERIFY LOCATION AND DEPTH OF ALL UTILITY LINES. jS BEDDING MATERIAL 2. CONTRACTOR TO CONTACT SERVICE PROVIDER FOR INSTALLATION \ =pCEN: •`''0,' E(,..•, l+,'i si: , PER LINE DETAIL I AND CONNECTION OF SERVICE L/NE. �,,Q. to WATER/WASTEWATER SERV/CE LINE \ \ '+ *, 1+ 01. r CS SECTION , •;-�, WATER/WASTEWATER CULVERT CROSSING DETAIL \ I�; :ti, ssloo\-__ SCALE: N.T.S. t' 0 - # Revision Date By Job No. 2016-444 i 1 DRB Revisions 4/4/2017 AWA Drawn by: AWA horn Residence C_ 1 co Big 04 N For Submittal6SG Utility Plan Date: 3/15/2017 1 18 West Sixth Street, Suite 200 N Glenwood Springs, CO 81601 4367 Columbine Drive QC: CL PE: CL of n 970.945.1004 www.sgm-inc.com File: 4367ColumbineDr_BM 7 /