Loading...
HomeMy WebLinkAboutB17-0114_E-601_1501879560.pdf itEir 'In4 IS ir UTILITY CO. PA \ EL: P1 GE\ DIST / 120 /240V 1 PHASE 3 WHE 200 AVPEE 3 ,< • 200 AVPEE� 3US NO .0 0 = PANEL—P1 PANEL—P2 SHORT CIRCUIT CALCS * cn coO° U' 120/240,1PH 120/240,1PH LOCAT 0\ GARAGE V OU \ T1 \ G FLUSH A C 101 000 0 o° 50 KVA X2 200A 200A TAG KAIC v> 240Y120V 1PH 3W 42 POLES 30 POLES Ci)(F,26) ,. 1-`01-'2, LOAD OUTLETS CIRCUIT BUS CIRCUIT OUTLETS LOAD '-` N o 3 X1 11.6 BREAKER BREAKER in �� LOAD DESCRIPTION - LOAD DESCRIPTION11111) 1 -0 I U z LINE A LINE B REC LITES POLES TRIP A B TRIP POLES LITES REC LINE A LINE B 5t 3 3 X1 G X2 8.3 1 1300 e MASTER BR DRYER 1300 2 0 ON BY HOLY CROSS X3 N/A 3 1300 2 30A ° _ 30A 2 1300 4 r ELECTRIC 170 FT (S1) 5 3140 CU-1 COOLING UNIT 8 OVEN 2550 6 _ X4 N/A 2 40A 30A 2 POWER SES A G � A V 7 3140 e 8 20A 1 _ 2550 8 r O-„ -ilE GIs>, ` * PER HOLY CROSS REQUIREMENTS ALL OVERCURRENT PROTECTIVE DEVICES 9 2520 UH-1 GARAGE UNIT HEATER GARAGE 540 1 O �,,. �� y°°.6` . o NTS SHALL HAVE A MINIMUM INTERRUPTING RATING OF 10,000 AMPS SYMMETRICAL 2 30A i vp; Q' 'Q°tis iii CURRENT OR GREATER 11 2520 ® 15A GFCI 1 1 KITCHEN REFRIGERATOR 180 12 i 13 1000 MICROWAVE 1 15A �— 1 1 700 1 4 .4 i4$S6 ;° `ri it RANGE VENT HOOD + ,°'� , , 15 1300 KITCHEN DISHWASHER GFCI A m 15A 1 HRV-1 HEAT RECOVERY VENTILATOR 972 1 6 tt FS '°• '°° E� Residential Standard Calculation Bighorn Residence BKR SlOr AX- Vail Colorado 1 7 1840 KITCHEN DISPOSAL 1 20A ° 20A 1 RECEPTS - FLEX ROOM AND CRAWL SPACE 1080 18 � `v.e.�,_ STEP 1 Article 220.42&220.52 Load SGM INC Area 4957 ,General Lighting load 14,871 VA Kirk Huyser 970-379-1622 1 9 1702 F-1/AC-1 FURNACE 1 20A e 20A 1 RECEPTS - ENTRY AND MUD ROOM 1080 20 2 Small Appliance 3,000 VA 1 15A 1 GAS RANGE 100 2 Laundry circuit 3,000 VA Lighting Calc 21 660 RF-1 MASTER BATH FLOOR HEATER e 15A 22 20,871 VA Gross 23 360 RECEPTS - MASTER BATH 2 1 20A e 20A 1 RECEPTS - KITCHEN Sc OUTSIDE NORTH 720 24 3,000 VA First 3 kVA@100% 6,255 VA Remainder @35% 25 360 RECEPTS - P.R. & ENTRY LEVEL BATHS 2 1 20A e 20A 1 RECEPTS - KITCHEN & OUTSIDE WEST 90026 9,255VA Total Lights _GFCI STEP 2 Article 220.50&220.51 Gen.Lgt.,SmApp.&Laun.Demand Load 9,255 VA 27 960 WASHER - MASTER B.R. IA BKR 1 15A e 20A 1 RECEPTS - LIVING ROOM 1080 28 COOLING UNITS HEATING CU-1 6,279 VA 4T F-1/AC-1 1702 Gas Total Heat Load 8,374 VA 29 660 RF-1 MASTER BATH FLOOR HEATER 1 15A ° 20A 1 RECEPTS - MASTER B.R., HALL 1260 30 2T RF-1 660 Total CU Load 6,279 VA 31 576 LIGHTING - MAIN LEVEL EAST 32 1 20A e 20A 1 32 1T UH-1 5040 Greater of Heat @ 100%vs.AIC @ 100% 8,374 VA .2T HRV-1 972 33 432 LIGHTING - MAIN LEVEL WEST 24 1 20A e 34 1.5T 0 - - — STEP 3 1 Article 230.53 35 414 LIGHTING - ENTRY LVL & OUTSIDE GARAGE 23 1 15A e - 36 #each Appliance Load 11,231 VA 1 ,Water Heater GAS 37 1 15A e 38 0 Refrigerator VA Included in appliance ckts Dryer Demand Load 10,000 VA 39 1 2OA 40 0 Freezer VA 2 'Dishwasher 2,600 VA Oven Demand Load 4,080 VA 41 ® 42 1 'Disposal 1,840 VA 0 Trash Compactor VA Service Load 42,939 VA 12848 13931 SUB TOTALS 12297 13822 1 'Microwave 900 VA U 0 Central Vac VA Volts 240 NOTES: SEE RESIDENTIAL LOAD CALCULATIONS FOR PANEL AND SERVICE SIZING. 0 'Mini Refrigerator VA Included with Wet Bar load A PROVIDE BRANCH BREAKER AFCI PROTECTION AS REQUIRED BY SECTION 210.12 OF 2014 NEC. J 1 ,Range hood 700 VA 2.8A hood,2.4A remote 300 cfm blower Amps 179 PROVIDE BOTTOM LUGS. 0 'WineCooler VA PANEL TO BE SERVICE RATED. N 0 'Ironing Center VA 25%of largest motor 4 AMPS 0 'Jacuzzi Tub VA • 0) L L) 0 Humidification VA Service 183 AMPS Q 0 Fan Coils VA 0) a) 0 Miscellaneous VA 0 Elevator VA • 1 Pumps 54 VA .C N Q) 1 Hot Tub 8,880 VA50AConfiguration PA \ EL: P2 GE\ DISTS / 120 /240V 1 PHASE 3 WHE V . L. O. : 200 AVPEE 3US _a ce 0 VA Total Appliance Load 14,974 VA oi If 4 or more fixed appliances use 75%demand 11,231 VA //�� L c STEP 4 'Article 220.54 A D 0 Electric ClotEhes Dryers 10,000 VA 2 ea heat pump ventless L O C A T O\ L A U \ M O O N V O U \ T \ G FLUSH STEP 5 Article 220.55 A1C 10, 000 0 .01 Um Oven 5,100 W 1 Cooktop W gas F- CIRCUIT CIRCUIT 1 oN Electric Ranges 0 5 m LOAD OUTLETS BREAKER BUS BREAKER OUTLETS LOAD 5 •O � D LOAD DESCRIPTION LOAD DESCRIPTION CO Total 5,100w U z LINE A LINE B REC LITES POLES TRIP A B TRIP POLES LITES REC LINE A LINE B U N Number of appliances 1 Dem.Factor 800/O 71- Cooktop&Oven Demand Load 4,080 W 1 1300 LAUNDRY RM DRYER e HOT TUB 4440 2 2 30A 50A 2 a 1300 8 4440 4 Note.The attached sizing is based on preliminary incomplete information. This calculation is conditional on a final design by the engineer. — to verifyconnected loads.The Owner understands that should connected load exceed allowance, are responsible for all cost 1 15A ° 15A 1 GFCI 0 they 5 BKR RECEPTS - WET BAR DISHWASHER 1300 6 6 associated with upgrading the service and the Engineer shall be held harmless for such cost.The Owner further agrees that the Engineer shall Na be compensated at their standard hourly rate for such inspections and calculations that are necessary to verify connected loads 7 960 WASHER - LAUNDRY ROOM BKRGFC1 15A ° 20A 1 RECEPTS - DEN, WET BAR, DECK 1440 8 N 9 360 LOFT AND BUNK ROOM BATHROOMS -- --' 2 1 15A e 20A 1 RECEPTS - GUEST BEDROOM 1080 1 0 11 180 GUEST BATHROOM 1 1 15A m 20A 1 GFCI CONDUCTOR SCHEDULE BKR RECEPT - LAUNDRY ROOM 180 1 2 > SYM DESCRIPTION V/PH/A COND. GROUND CONDUIT # OF PARR WIRE TYPE NOTES 13 1260 RECEPTS - BUNK ROOM AND DECK 1 15A N - 15A 1 17 LIGHTING - LOFT & DECK 306 14 CONDUIT 120 VOLT SINGLE PHASE BRANCH CIRCUITS R1 15 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/15 2#14 1#14 1 CU-NM-B N2,N3 15 1440 RECEPTS - LOFT 8 1 15A e 15A 1 14 LIGHTING - UPPER LEVEL EAST 252 16 R7 20 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/20 2#12 1#12 1 CU-NM-B N2,N3 _ 1 7 SMOKE / CO ALARMS ;A 1 20A e 15A 1 16 LIGHTING - UPPER LEVEL WEST 288 1 8 o R3 25 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/25 2#12 1#12 1 CU-NM-B N2,N3 - --c) (R4) 30 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/30 2#10 1#10 1 CU-NM-B N2,N3 1 9 1 20A e 15A 1 20 W (R5) 40 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/40 2#8 1#10 1 CU-NM-B N2,N3 21 8 15A 1 22 W (R6) 50 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/50 2#8 1#10 1 CU-NM-B N2,N3 o (R7) 60 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/60 2#6 1#10 1 CU-NM-B N2,N3 23 1 20A 24 (R8) 70 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/70 2#4 1#10 1 CU-NM-B N2,N3 25 - Z N 120/1/80 2 4 1 10 1 CU-NM-B N2,N3 ° 26 y a m (R9) 80 AMP BRANCH CIRCUIT - 2 CONDUCTOR # # (R10) 100 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/100 2#3 1#8 1 CU-NM-B N2,N3 27 ° 28 2 Ce I- ILI (--D 20 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/20 2#1 1#8 1 CU-THWN 29 30 y a �7 15 AMP BRANCH CIRCUIT - 2 CONDUCTOR 120/1/15 2#14 1#14 1 CU-THWN W CONDUIT 208 VOLT SINGLE PHASE BRANCH CIRCUITS 31 _ 32 m .' �4 15 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/15 3#14 1#14 1 CU-NM-B N2,N3 33 34 o 0 E 1® 20 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/20 3#12 1#12 1 CU-NM-B N2,N3 wN (R16) 25 AMP BRANCH CIRCUIT — 3 CONDUCTOR 240/1/25 3#12 1#12 1 CU—NM—B N2,N3 35 36 o v 1 CT30 AMP BRANCH CIRCUIT — 3 CONDUCTOR 240/1/30 3#10 1#10 1 CU—NM—B N2,N3 37 38 (R16) 40 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/40 3#8 1#10 1 CU-NM-B N2,N3 DRAWN BY: KH N- (R1c 50 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/50 3#8 1#10 1 CU-NM-B N2,N3 39 40 `o R 60 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/60 3#6 1#10 1 CU-NM-B N2,N3 41 e 42 CHECKED BY: KH ,N R7 70 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/70 3#4 1#10 1 CU-NM-B N2,N3 SUB TOTALS o 80 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/80 3#4 1#10 1 CU-NM-B N2,N3 12848 13931 12297 13822 (N SCALE:NONE 5 ® 100 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/100 3#3 1#8 1 CU-NM-B N2,N3 74 125 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/125 3#1 1#8 1 CU-NM-B N2,N3 NOTES: SEE RESIDENTIAL LOAD CALCULATIONS FOR PANEL AND SERVICE SIZING PROVIDE BRANCH BREAKER AFCI PROTECTION AS REQUIRED BY SECTION 210.12 OF 2014 NEC o ® 150 AMP BRANCH CIRCUIT - 3 CONDUCTOR 240/1/150 3#6 1#8 1 CU-NM-B N2,N3 Q. a © BUILDING SERVICE-UNDERGROUND-ALUM 240/1/200 3#250 1#4 1 AL-THHN Electrical ° © BUILDING SERVICE-UNDERGROUND-ALUM 240/1/100 3#1/O 1#4 1 AL-THHN o CONDUIT 120/208 VOLT SINGLE PHASE BRANCH CIRCUITS Schedules c �70 200 A FEEDER - 3 CONDUCTOR W/G 120/240/1/200 3#3/C1#1/0 1 CU-SE N2,N3 CONDUIT 120/208V OR 277/480 THREE PHASE BRANCH CIRCUITS a : © BUILDING SERVICE-UNDERGROUND-ALUM 240/1/200 3#250 1 AL-THHN o N2. AMPERAGE RATINGS GIVEN ARE MINIMUM RECOMMENDED SIZES FOR STANDARD CONDITIONS AND 75°C AMPACITY. E-601 1 DERATE FOR TEMPERATURE, MORE THAN 3 C.C.C, ETC REFER TO NEC. N3. CONDUCTORS AND SHEATHING SHALL BE COLOR CODED PER NEC REQUIREMENTS