HomeMy WebLinkAboutB17-0114_E-602_1501879560.pdf „,,,...440"FP4,„ z ec fie, ' icroJ16. 08/042 Or CN10 ELECTRICAL LEGEND GENERAL NOTES V ° 7 Soo cm (/) N 1. ALL LIGHTING SWITCH LEGS SHALL USE A DEDICATED NEUTRAL WIRE. 0 6 UU 2. EC SHALL LABEL ALL J—BOXES, RECEPTACLES,AND LIGHTING FIXTURES WITH PANEL (7) C 3 LOW VOLTAGE SYSTEMS FIRE ALARM SYSTEM LIGHTING SYMBOLS AND CIRCUIT NUMBERS, USING DYNO TAGS. (1s .i DISTRIBUTION EQUIPMENT SYMBOLS V V TELEPHONE OUTLET IN FLOOR OR WALL AN ANNUNCIATOR AO RECESSED OR SURFACE DOWNL/GHT 3. x Q O 120V DUPLEX RECEPTACLE 0 18” UNLESS NOTED EC SHALL PROVIDE STAINLESS STEEL COVER PLATES FOR ALL OUTLETS AND SWITCH 0 0 - COMPUTER/DATA OUTLET IN FLOOR OR WALL �� CHIME/STROBE A Q WALL MOUNTED LIGHT FIXTURE @ 240(208)V RECEPTACLE © 18" UNLESS NOTED PLATES. o .. TELEPHONE BACKBOARD " 4. ALL CONDUIT SHALL RUN PARALLEL TO BUILDING STRUCTURE. g ( Li FACP FIRE ALARM CONTROL PANEL A\ RECESSED 2X4 LIGHT FIXTURE e 120V DOUBLE DUPLEX RECEPTACLE ® 18 OS OCCUPANCY SENSOR UNLESS NOTEDo0 c O SURFACE 2X4 LIGHT FIXTURE ® 5. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE LATEST EDITIONS OF THE RULES, r— ANN FIRE ALARM ANNUNCIATOR PANEL FLUSH FLOOR DUPLEX RECEPTACLEI� TO LINE VOLTAGE THERMOSTAT AT 60" UNLESS NOTED FA A REGULATIONS AND CODES OF THE STATE OF COLORADO AND THE LOCAL JURISDICTIONAL r U O, FIRE ALARM PULL STATION C DUPLEX RECEPTACLE HALF-SWITCHED 0 18" AUTHORITY NEC 2014. VIDEO INTERCOM/ DOOR ENTRY UN/T. / A RECESSED 2X2 LIGHT FIXTURE UNLESS NOTED ❑Q ALARM HORN OR SPEAKER __ WITH .V MONITOR. % RECESSED 2X4 LIGHT FIXTURESHADING ON MULTI-OUTLET PLUG STRIP 6. THIS CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH ALL OTHER BUILDING TRADES TO ❑Q� COMB/NAT/ON HORN/STROBE OR SPEAKER/STROBEENSURE PROPER INSTALLATION OF SYSTEMS SHOWN. ` FIXTURE /ND/GATES BATTERY BACKUP Akx FAP FIRE ALARM PANEL o H THERMAL HEAT DETECTORO OHO JUNCTION BOX IN FLOOR, CEILING OR IN WALL ���p RF GIST�� OX 4' STRIP FIXTURE 7. THIS CONTRACTOR SHALL REVIEW EXISTING FIELD CONDITIONS PRIOR TO THE PURCHASE, �Q•,..•°•.�•••..,4 FABRICATION AND INSTALLATION OF ANY EQUIPMENT DUCTWORK, PIPING, ETC., AND SHALL :';�-N �'S'''•F� h A INTERCOM OUTLET SMOKE//ON/ZATION DETECTOR o/o TRACK LIGHT AS NOTED OR SCHEDULED CONDUIT RUN CONCEALED INFORM THE ARCHITECT OR GENERAL CONTRACTOR OF ANY DISCREPANCIES FOR RESOLUTION. i C:`',/y.� }� A FIRE TELEPHONE OUTLET o P PHOTOELECTRIC SMOKE DETECTOR X=TRACK LENGTH Y=# OF HEADS SEE SPECIFICATION SECTION 15010 FOR MORE REQUIREMENTS. /� f /z4 f 7 t �C/RCU/T HOMERUN ; 14836 i 'EH CABLE TV OUTLET o H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR A4 1 WALL WASHER X CONDUIT SEALOFF 8. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT SHOW EVERY DUCTWORK AND lj .0� w'/' PIPING OFFSET REQUIRED. THIS CONTRACTOR SHALL COORDINATE WITH THE EXISTING, AND OR 11�u,`►° ,1C_ • PUBLIC ADDRESS SPEAKER. S R DUCT DETECTOR A I CONDUIT STUB-UP - CAP & MARK NEW, STRUCTURE ELECTRICAL, MECHANICAL, PLUMBING, FIRE PROTECTION AND CEILING TO ‘t cis "• *c�y. \{z AERIAL - UHF/ VHF TV 0 SPRINKLER SYSTEM FLOW SWITCH 0 POLE-MOUNTED FIXTURE LINE VOLTAGE SWITCHES PROVIDE OFFSETS AS REQUIRED AND APPROPRIATE DO NOT SCALE DRAWINGS. �vlO=AX-`- WW VOICE ALARM. ® I SPRINKLER SYSTEM TAMPER SWITCH A POST (BOLLARD) FIXTURE S SINGLE THROW SWITCH 9. SOME OF THE CEILING SPACE IS TO BE USED AS A RETURN AIR PLENUM. ALL MATERIALS ? PUBLIC ADDRESS VOICE SWITCH. (MUTE) SHALL CONFORM TO NFPA 90A FOR FIRE AND SMOKE RATINGS. rii STROBE AN--- ---A STEP L/GHT 2 2-POLE SWITCH AMPLIFIER. 10. THIS CONTRACTOR SHALL PROVIDE ACCESS TO ALL EQUIPMENT, BOXES, ETC., ABOVE ALL AMP �\ FIRE STROBE AND HORN XA, I3< 3-WAY SWITCH NON-LAY/N CEILINGS AND /N OTHER CONCEALED SPACES FOR SERVICING AND MAINTENANCE.EMERGENCY CALL BUTTON. 1—H H E H I F I CEILING OR WALL MOUNTED EXIT LIGHT4-WAY SWITCHEl FIRE HORN © CO/L (CONTACTOR) K = KEY-OPERATED SWITCH 11. THIS CONTRACTOR SHALL PROVIDE ACCESS TO ALL EQUIPMENT BOXES, ETC., ABOVE ALL REMOTE INDICATOR LIGHT TO TO = THERMAL OVERLOAD SWITCH NON-LAY/N CEILINGS AND IN OTHER CONCEALED SPACES FOR SERVICING AND MAINTENANCE. COMB/NAT/ON F/RE A EMERGENCY BATTERY LIGHTS P = SWITCH WITH PILOT LIGHT Q CND SMOKE DAMPER 12. ALL EXPOSED WIRING TO BE IN EMT CONDUIT. WIRING ABOVE LAY IN CEILINGS SHAL BE IN SMOKE DAMPER L LIGHTING CONTROL ALL LIGHT SWITCHES AT 48" UNLESS NOTED EMT OR MC TYPE CONDUIT EXPOSED RACEWAYS IN APPARATUS BAY WITHIN 12' OF FLOOR TO /� 0 DIMMER SWITCH W/ WATTAGE BE RIGID CONDUIT. ELECTRICAL CONTROLS / \ HIGH BAY FIXTURE $0 INTEGRAL OCCUPANCY SENSOR AND SWITCH - 13. THIS CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SPATIAL REQUIREMENTS, ACOUSTICAL, SECURITY SYSTEMS o PUSHBUTTON CONTROL STAT/ON LT LIGHTING TRANSFORMER. LINE VOLTAGE THERMAL, AND ELECTRICAL PERFORMANCE CHARACTER/ST/CS AND COORDINATION OF ALL DIG/TAL (LOW VOLTAGE) SWITCHES SUBSCRIPT INSTALLATION REQUIREMENTS FOR EQUIPMENT SUBSTITUTIONS FROM THAT DEFINED AS THE DC# SECURITY - DOOR CONTACT. PI PHOTOELECTRIC CELL A S-1 2) INDICATES SW/ & /OF BUTTONS NO SUBSCRIPT BASIS FOR DESIGN. REVIEW AND APPROVAL BY THE DESIGN TEAM DOES NOT ALTER OR _p 2 WAY FLOOD. INDICATES SPST TOGGLE SWITCH MIT/GATE THIS. 41) SECURITY - SHUNT KEY SWITCH. Pc f PHOTOELECTRIC CELL AWP 11 WALL PACK RO DIGITAL (LOW VOLTAGE) SWITCH AND OCCUPANCY 14. THIS CONTRACTOR SHALL VISIT THE PROJECT SITE TO BECOME ACQUAINTED WITH EXISTING SENSOR CONDITIONS. FAILURE TO DO SO SHALL NOT RELIEVE CONTRACTOR FROM THE RESPONSIBILITY KB# SECURITY - KICK BAR. TS TIME SWITCH A (JH DECORATIVE SCONCE SELECTED BY OTHERS ® DIGITAL (LOW VOLTAGE) LIGHT SENSOR FOR PERFORMING THE WORK. 430 SECURITY - WATCHMAN TOUR STAT/ON. TC TIME CLOCK A 15. MAINTAIN ALL REQUIRED SERVICE AND ACCESS CLEARANCES REQUIRED BY CODE OR THE LIGHTING CONTACTOR. x DIRECT/INDIRECT SCONCE SELECTED BY OTHERS • DISCONNECT SWITCH MANUFACTURER FOR ALL NEW AND EXISTING EQUIPMENT %CAD SECURITY - PAN/C/ RAID ATTACK SWITCH. 3 X 0AVOLTAGE TRANSFORMER. DECORATIVE PENDENT SELECTED BY OTHERS —..1-\— FUSES X Y' DENOTES COIL RATIO. REVIEWED BY ENGINEER. CIRCUIT BREAKER ® SECUR/TY - ELECTRICALLY OPERATED LOCK. MCT MEASUREMENT CURRENT TRANSFORMER. U X:Y 'X.•Y' DENOTES COIL RATIO. 0 DECORATIVE CHANDAL/ER SELECTED BY OTHERS �J CURRENT TRANSFORMER REVIEWED BY ENGINEER. ® SECURITY - MANUAL LOCK. PCT PROTECTION CURRENT TRANSFORMER.X. R1 LIGHTING RELAY # T-X TRANSFORMER. J x:Y Y DENOTES COIL RATIO. EL EC TRI CA L LAYERS XV .KVA DENOTES RATING (KILOVOLT AMPS). PI SECURITY - PASSIVE INFRARED DETECTOR. OVER CURRENT PROTECTION RELAY. ?KVA XV' DENOTES PR/MARY VOLTAGE. 6 A ��I LANDSCAPE ACCENT LIGHT Y APPEARANCE LAYERS SECURITY - PASSIVE INFRARED DETECTOR 360: F EARTH FAULT PROTECTION RELAY 'YV' DENOTES SECONDARY VOLTAGE. C) 360° PI 7E-COND-AV •" 0AV AV AV AV AV yi UNDER VOLTAGE PROTECTION RELAY. ® 7E-COND-BCIR 0 c ® ELECTRIC METER BC BC BC BC BC a)PI SECURITY - CARD/ DIGITAL ACCESS CONTROL UNIT. p PHASE FAILURE RELAY. IX MAGNETIC MOTOR STARTER CCN CCTV CCN CCTV CCN 7E-GOND-CCN PI SECURITY - KEYPAD ACCESS CONTROL UN/T. D D D D D D 7E-COND-DATA C 'N xxx ABBREVIATIONS phDISCONNECT SWITCH EP EP EP EP EP 7E-COND-EMPR •— N SECURITYOE - KEYPAD ACCESS CONTROL UNIT. AC - ABOVE COUNTER f 0 o P FUSED SWITCH F F F F F F 7E-GOND-FDR A AMMETER. AFF - ABOVE FIN/SHED FLOOR /1 '?A' DENOTES RATING (AMPS) 7E-GOND-FIGO PI SECURITY - VIBRATION DETECTOR. AFG - ABOVE FIN/SHED GRADE '?P' DENOTES POLES. FO FO FO FO FO E i V VOLTMETER. FA FA FA FA FA 7E-COND-FSAL D 0 AL - ALUMINUM 7E-COND-GRND C — PANELBOARD OR LOAD CENTER, FLUSH OR S PI SECURITY - PERSONNEL ATTACK CU - COPPER SURFACE MOUNTED G G G G G G KW KILOWATT METER. DES/G.- DES/GNAT/ON11 7E-GOND-HV ca L PI SECURITY - BREAK GLASS DETECTION. EM - EMERGENCY HV HV HV HV HV HV �L.)I GROUND I I I I I I 7E-GOND-INT a> D MAXIMUM DEMAND METER. EMP - ENERGY MANAGEMENT PANEL o SECURITY - EMERGENCY DOOR RELEASE BREAK ® MOLDED CASE CIRCUIT BREAKER LV LV LV LV LV LV 7E-COND-LV o DR GM '9 REQUEST TO EX/T PUSH. RP REACT/VE POWER METER. EWC - ELECTRIC WATER COOLER 7E-GOND-MV o GND - GROUND 0MV MV MV MV MV NO M MOTOR CONNECTION GFI - GROUND FAULT INTERRUPTER S S S S S S 7E-GOND-SEC E ATS AUTOMATIC TRANSFER SWITCHC O Q IAN SECURITY - CCTV CAMERA. NF - NOT FUSED SLR SLR SLR SLR SLR 7E-COND-SLR �} L XV DELTA/DELTA TRANSFORMER. MC - NOT IN CONTRACT TUBULAR HEATER. T T T T T T 7E-COND-TELE V N Q GLOBE TYPE CCTV CAMERA. ?KVA KV A`?KVA' DENOTES RATING (KILOVOLT AMPS). NL - NIGHT LIGHT co_'XKW' DENOTES RATING (KW). TV TV TV TV N 7E-GOND-TV O 'XV' DENOTES PR/MARY VOLTAGE. NTS - NOT TO SCALEEARTH BOND. 7E-GOND-SWL °NDOOR RELEASE BUTTON. 'YV' DENOTES SECONDARY VOLTAGE. UG - UNDERGROUND �� SWL SWL SWL SWL SWL Q. WP - WEATHER PROOF G 7E-EQUIP-LFIX o / XFMR- TRANSFORMER r GENERATOR. N 1 AUDIO VISUAL. +18" - MOUNTING HEIGHT TO CENTERLINE 7E-EQUIP-CBCT SEC SECURITY AREA CONTROL PANEL. WYE/DELTA TRANSFORMER. OF DEVICE AFF OR AFG XVMO MOTOR. 7E-EQUIP-DATA ?KVA`?KVA DENOTES RATING (KILOVOLT AMPS). C - COUNTERTOP 7E-EQUIP-DEV o W 'XV' DENOTES PRIMARY VOLTAGE. 7E-EQUIP-EMPR 'YV' DENOTES SECONDARY VOLTAGE. OLS DIRECT-ON-LINE STARTER. Q n STAR-DELTA STARTER. 7E-EQUIP-FSAL 7E-EQUIP-LFIX-SITE WYE/WYE TRANSFORMER. n AUTO-TRANSFORMER STARTER. 7E-EQUIP-LV N ?KVA'?KVA' DENOTES RATING (KILOVOLT AMPS). l J 7E-EQUIP-MV N Y W 'XV' DENOTES PRIMARY VOLTAGE. BC BATTERY CHARGER. SAH '?Ah' DENOTES AMPERE HOURS. 7E-EQUIP-POLS Q YV' DENOTES SECONDARY VOLTAGE. 7E-EQUIP-SEC N 7E-EQUIP-TELE CI CONTROL PANEL. 7E-EQUIP-TRNF EPCI EMERGENCY POWER OFF BUTTON. PANEL MOUNTED CIRCUIT BREAKER ESO ESO ESO ESO ESO 7E-SERV-OH I '?A' DENOTES DEVICE SETTING (AMPS). ESU ESU ESU ESU ESU ES 7E-SERV-UG ?A '?A' FRAME SIZE (AMPS). ?CB '?CB' DENOTES ACB OR VCB OR OCB. (BREAKER o 0 ?PM roQS W Y I' DENOTES No. OF POLES. W w ce I- o ) j u) Lu 0 or x MOTOR CONTROL CENTER y a 0 .o 0 ?A1 BUS BAR. '?' INDICATES No. OF BARS .0 4 BARS INDICATES CLEAN EARTH 13, 3 A' INDICATES RATINGS (AMPS). I- 0 GROUND FAULT PROTECTION o 7, DRAWN BY: KH O I o CHECKED BY: KH 0 P 0 0 0 Q SCALE: O O 0 O Legends and . Specs CI- CI- ELECTRICAL LEGEND AND SPECIFICATIONS CII N E-602 N