HomeMy WebLinkAboutB17-0114_M-101_1501879560.pdf 4k:14110 IP Z 4. AlliK.16:4 O © © 4 © 6 O 08/04/ Graphic ScaleX o o c ( 0 4' 8' o `C 7 • 5 co 0) Scale: 1/4" = 1 0" N N -0 (009) ; 3N 0) QONOZONE 1 (MAIN LIVING AREAS) p �j1 (1) _ ZONE 3 (LOFT LEl/EL) BUILDING DEPARTMENT NOTE. 5"0 UP „ THE MECHANICAL EQUIPMENT IS L OCA TED ON A O 5 01 UP 4 CRAWLSPACE ZONE 2 (MASTER BEDROOM) CONCRETE PAD BUT NOT ENCLOSED FROM THE r— 0, 10 �0 VENTILATION, 18 CSM r O� SURROUNDING CRAWLSPACE. THEREFORE, THE EXISTING -3'v� FL E UP CRAWLSPACE VENTILATION INDICATED ON THIS DRAWING ❑M (AND PER THE VENTILATION SCHEDULE) REMAINS 10X8 EX FROM —1 2X8 SUFFICIENT. GENERAL NOTES: 1. AIR TERMINAL DEVICES ARE CEILING MOUNTED UNLESS —''�` LEVEL ABOVE _ \ ac £{ `� Lo rABO E FROM © N El NOTED OTHERWISE OR FED FROM BELOW. `� ...r., •fi I 8X ROUTE 3 4" CONDENSATE FROM PRIMARY DRAIN PAN .. c.'4 } ' � � *"111141OX10 14X14 1 x v / 2. ROUTE DUCT WITHIN JOIST SPACES TO THE EXTENT - , 16X18 1 TO FLOOR GRAIN AND TERMINATE WITH AlR GAP. SLOPE � *�-7 10X8 OA \� AT 1% TOWARD DRAIN. PROVIDE CONDENSATE SENSOR POSSIBLE. '1 ;03 ' 5aA AT SECONDARY DRAIN PORT REFER TO SEQUENCE OF '� '; / 'FROM ABOVE 10"0 T. •� !� } 4; � CONCRETE PAD — t' OPERATIONS FOR ADDITIONAL INFORMATION. 3. FLUE SHALL BE SCHEDULE 40 PVC, DESIGNATED AS ��$�••.,• ••.• �'rV ►I /; NEX w COMPLIANT WITH ASTM D1785, AND FITTINGS SHALL BE ;�x �` ;��+�* ; +RS/RL TO , `= '� CONNECTOR ASTM 2665. % y 05.1 ONDENSING UNIT I`18X? Q o k ROUTE 3/4" PVC CONDENSATE FROM FLUE DRAIN TO X A UP SA UP LL W • °0 ACID NEUTRALIZATION KIT. DRAIN NEUTRALIZATION KIT TO 2 8 S ` O • 7"" UP FLOOR DRAIN AND TERMINATE WITH AIR GAP. SLOPE AT TO LOFT (\'� "/) 4 10X8 EX FROM t� 1 '' 1% TOWARD DRAIN. o LEVEL ABOVE o I+ Ci ± CONNECT FRESH AIR 4'0 CRAWLSPACE I4 TO RETURN PLENUM EXHAUST, 18 CFM ' 24X12 RA FROM P LEVEL ABOVE [50 UP >i0 I , gh ) ei co 20X 10 16X8 17 _1 )—[.)--I, -_-- 0 60 UP- 1 ,2 - I Tutu-e a/v 24x122 l C_, MECH, rack \ ________Thi-----_______ (access) �I r MOUNT GRILLES 6" M UNT GRILLES 6" GYM/ 6'r5 BLOW CEILING U \ RIflat 03J E---------10'-6" ®88 ex room/bedroom 5 . R112x4 J ` 12x4 I u inI Li ENTRY 7'l vestibule R� 12x4 flat - T wi 10 i0 U V C DUCT LOCATED IN SOFFIT ABOVE. l a t l — INSULATE DUCT PER SPECIFICATIONS s' n" I bat�i MUDR ❑M/ _ _I= ! g e r room �I�� - STARTING FROM 5' WITHIN THE N h�I !`� C'� MINI7EIMIENJEZ 1MMII�� BUILDING ENVELOPE, THROUGH THE •— ••Y■_�■■_•■■=� SOFFIT AND DOWN STREAM TO THE 0 I 7 20 1 _. t� TERMINAL DEVICE. <� 133 ` • _ � ®12x4 [i. 1. , , i .1 _ . U ._ m t, e • . _ . _ . _ • , _ ElwaidErionli ., m_i. 1._.• sm. No E CO D . 0 • -- D N ' I I 6"OUP 6'0UP „i, cc-) • _ • _ • _ • • _ • _ • _ _ • ._ • _ _ . _ . _ • • _ •,.e„ 0 -71- ,o I N I,c3 co B 8' UP� 8"� UPi B q, E N GARAGE on site parking driveway N I 1(unheated) N N I'' m v . co I 3 N z w C) 0 z 0 m — $7"' I w 2 Ce Ct y w a o f CO a CL w o A i - Ao m i1 i N. N. L 33 0 F co N < v o rn p0 0 0 4 0 DRAWN BY: BC Q CHECKED BY: TH Z V a3 4 CO SCALE:114"=1'-0" O O i O Entry Level -ie ENTRY LEVEL MECHANICAL PLAN Mechanical Plan tl- F.F.E=100.00 =8467'A.S. NII 'Cl N M- 101 N