Loading...
HomeMy WebLinkAboutB17-0114_M-601_1501879560.pdf z Of ' si jQi716o O 08/04e LOUVER SCHEDULE HEAT RECO VERY VEIV TI LA TOR SCHEDULE 0 - d FACE PRESSURE FREE FILTER 0 <O UNIT TAG MANUFACTURER & SERVICE LOCATION CFM SIZE VELOCITY DROP AREA FRAME FINISH REMARKS OUTSIDE AIR FAN EXHAUST FAN WINTER SUMMER HEAT RECOVERY MODULE ELECTRICAL DATA DATA - r E MODEL NO. (L"x H) (FPM) (IN SP) (SOFT) TYPE UNIT TAG MANUFACTURER & LOCATION OPER. WT REMARKS (f) e0 CD MODEL E.S.P. E.S.P. OA FA OA FA CORE FLA (LBS) 0 CFM HP (IN) CFM HP (IN) EAT LAT EAT LAT 'PE MATERIAL %EFF. V PH HZ (EACH)MCA MOP TYPE 0 5 U GREENHECK PROVIDE BIRD " L-1 ESD-403 OA INTAKE BELOW DECK 378 12X12 360 0.07 0.47 CHANNEL MILL SCREEN AND RENEWA/RE STATIC 75 (WINTER) FURNISH FACTORY DISCONNECT, 24V u) C ) BACKDRAFT DAMPER HRV-1 EV450/N CRAWLSPACE 378 0.5 0.75 378 0.5 0.75 -18 77 82 49 PLATE STANDARD 70 (SUMMER) 120 1 60 8.1 10. 1 15 MERV 8 141 TRANSFORMER, AND EC MOTORS FOR r .i 1- BALANCING PURPOSES. x 0_0 GREENHECK PROVIDE B/RD V) v O L-2 EXHUAST BELOW DECK 378 12X12 360 0.07 0.47 CHANNEL MILL SCREEN AND BASED ON 70F/75F INDOOR CONDITIONS (WINTER/SUMMER). N-0 ESD-403 BACKORAFT DAMPER. > U • 00 00 r 0 or FURNACE SCHEDULE ELECTRIC DIMENSIONS OUTPUT AT MINIMUM ,. ti VENTILATION SUMMARY MARK SERVICE AREA HEATING INPUT ALTITUDE AIRFLOW EFFICIENCY CONTROL MANUFACTURER & MODEL NOTES TYPE (MBH) (MBH) (CFM) (AFUE) HEIGHT WIDTH DEPTH WEIGHT ��.-` a.°.1.'.!VIII it OCCUPANCY AREA OR OUTSIDE AIR EXHAUST NOTES VOLTS.-PH.-CY. MCA/MOP (IN) (IN) (IN) (LB) -, 1 �,'e - G'g'�,o 4� 11 QUANTITY REQUIRED/PROVIDED REQUIRED/PROVIDED r d - � NATURAL CARRIER { F-1 ALL LEVELS 120 84 2500 97% 115-1-60 14.8/20 35 24.5 29 290 CARRIER 59MN7A 120V24 1, 2. Aire ;' +'' GAS INFINITY WHOLE HOUSE 4250 SQ. FT 90/360 NA PER IRC TABLE M1507.3.3(1) 4�r 'VENTILATION (CONTINUOUS) 'fio� ,.NOTES: _1. UNIT SHALL BE VARIABLE FLOW, MULTI-ZONE, MODULATING HEAT, AND HAVE FACTORY DX COOLING OPTION. SEE RELATED SPLIT DX SYSTEM SCHEDULES. 6% /0 1PXL f KITCHEN HOOD NA NA 300/300 PER RANGE MANUFACTURER 2. FURNISH THE FOLLOWING ACCESSORIES: FACTORY DISCONNECT CONDENSATE NEUTRALIZATION KIT, ACCESSORIES REQUIRED FOR HIGH ALTITUDE OPERATION, FACTORY DX COOLING MODULE, HUMIDIFICATION MODULE � N. _ BATHROOM 8 NA 160/360 PER IRC TABLE M1507.4 EXHAUST (CONTINUOUS) GRILLE, REGISTER, AND DIFFUSER SCHEDULE _ CRAWLSPACE 887 SQ. FT NA/18 18/18 PER IRC SECTION R408.3 SYMBOL SERVICE MFR. MODEL FACE TYPE MOUNTING MATERIAL FINISH DAMPER ACCESSORIES FACE SIZE IN (CONTINUOUS) (CONTINUOUS) ( .) / NECK SIZE (IN.) NOTES: TYPE LBPH-25B FACE DIMENSIONS WILL BE APPROX. SUPPLY LINEAR BAR FACTORY OBD WITH S 1 DIFFUSER PRICE PENCIL GRILLE SURFACE ALUMINUM WHITE SET SCREW NONE 2 IN. LARGER THAN NECK SIZE / 1, 2. PROOF CORE AS NOTED S2 SUPPLY PRICE SCD 3-SQUARE LAY-IN STEEL FACTORY NONE NONE 24 X 24 /AS NOTED DIFFUSER CONE WHITE Ld ShortFormJob: 2016-444-001 R1 RETURN PRICE PDDR PERFORATED LAY-IN STEEL FACTORY NONE NONE 24 X 24 / 22 X 22 w r i g h t s o ft oaDate: 3/22/2017 GRILLE FACE WHITE - Entire House By: EXHAUST FIXED ANGLE DUCT OBD WITH PROVIDE SHEET FACE DIMENSIONS WILL BE APPROX. El REGISTER PRICE 530 SINGLE MOUNT STEEL MILL FINISH SET SCREW METAL STANDOFF 2 IN. LARGER THAN NECK SIZE / DEFLECTION COLLAR AS NOTED 1. DAMPER SHALL BE ADJUSTABLE THROUGH THE FACE OF THE DEVICE 2. GRILLE SHALL BE LABELED AS SUITABLE FOR FLOOR MOUNT Project Information U For: Columbine Spec Homes J Vail, CO SPLIT SYSTEM INDOOR UNIT SCHEDULE J ELECTRIC POWERED DIMENSIONS FAN FAN POWER POWER COOLING Design Information MARK SERVICE ARRANGEMENT SUPPLY AMPERAGE SUPPLY SUPPLY FROM CAPACITY MANUFACTURER & NOTES: AREA (CFM) (FLA) (MCA) (MOCP) UNIT/N) L W H WEIGHT (MBH) MODEL Q U Htg Clg Infiltration VOLTS.-PH.-CY. C Outside db (°F) -18 82 Method Simplified (IN) (IN) (IN) (LB) 0 Inside db(°F) 70 75 Construction quality Average 4) 7 Design TD (°F) 88 7 Fireplaces 2 (Average) FURNANCE SEE SEE FURNACE C N Daily range H AC-1 F-1 FURNACE MODULE FURNACE NA SCHEDULE NA NA NA 29 20 23 88 60 CARRIER CNPH 1 •_ Inside humidity(%) 50 50 SCHEDULE -0 f Moisture difference (gr/Ib) 73 -49 1. FURNISH THE FOLLOWING ASCCESSORIES: HIGH CONDENSATE AUDIBLE ALARM AND UNIT SHUT DOWN IN COMPLIANCE WITH 2015 IMC SECTION 307 OR IRC M1411.3. 1. E i D 0 s HEATING EQUIPMENT COOLING EQUIPMENT O CD L Make n/a Make n/a U CO cb 0 Trade n/a Trade n/a SPLIT SYSTEM OUTDOOR UNIT SCHEDULE (COOLING ONLY) Q Model n/a Cond n/a oo AHRI ref n/a Coil n/a _^ -o AHRI ref n/a GROSS ELECTRIC DIMENSIONS ` ;$ E COOLING AMBIENT POWER POWER Efficiency n/a Efficiency n/a SERV/CECOOLING EFFICIENCY MANUFACTURER & CO MARK CAPACITY TEMPERATURE SUPPLY SUPPLY NOTES:input Sensible cooling 0 Btuh AREA CAPACITY (SEER) MODEL Heating output 0 Btuh Latent cooling 0 Btuh (TON) (MBH) (F) VOLTS.-PH.- (MCA) (MOCP) LENGTH WIDTH HEIGHT WEIGHT 71- Temperature rise 0 °F Total cooling 0 Btuh CY. (IN) (IN) (IN) (LB) N Actual air flow 0 cfm Actual air flow 0 cfm - Q Air flow factor 0 cfm/Btuh Air flow factor 0 cfm/Btuh Q Static pressure 0 in H2O Static pressure 0 in H2O CU-1 AC-1 4.0 48 82 19 230-1-60 27.3 40 33 33 48 255 CARRIER 24VNA948A003 ALL rn Space thermostat n/a Load sensible heat ratio 0 0 4 1. PROVIDE LOW AMBIENT COOLING KIT DOWN TO -15F OPERATION, AND HOT GAS BYPASS. 2. FURNISH WITH FACTORY DISCONNECT. k ROOM NAME Area Htg load Clg load Htg AVF Clg AVF E (ft°) (Btuh) (Btuh) (cfm) (cfm) ( . UnitHeater 625 15455 2444 350 152 MISCELLANEOUS EQUIPMENT SCHEDULE N AH1 4570 73740 40646 2500 2500 0 N L. Entire House 5195 89195 43084 2850 2891 SYMBOL TYPE SERVICE MFR. MODEL ELECTRICAL HEAT OUTPUT DESCRIPTION Q Other equip loads 0 0 rn Equip. @ 0.87 RSM 37483 Latent cooling 0 4' RADIANT U.L. LISTED ELECTRIC HEATING MAT 12 TOTALS 1 5195 I 89195 I 37483 I 2850 1 2891 RF-1 FLOOR MASTER WATTS RADIANT TAPEMAT 120V/10/60 0.66 KW WATTS/SQ. FT. NOMINAL, ZONE BASED ON 55 SQ. is 1' ELECTRIC BATHROOM 5.5 AMPS FT. FURNISH WITH PROGRAMMABLE WALL o HEAT MAT THERMOSTAT. a T3 _o Q U) Bold/italic values have been manually overridden w I- I u> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W z or DUCT INSULA TION SUMMARY KITCHEN HOOD yiu 0E 017-Mar-29 14:14.07 o ,� wrightsoftihtft Right-Suite®Universal 2017 17.0.19 RSU19899 Page 1 ELECTRIC DIMENSIONS DUCT SIZE m ACCA ...hanical\Loads\Vail Loads\ColumbineSpecHomes.rup Calc=MJ8 Front Door faces: S LOCATION SERVICE INSTALLED R VALUE NOTES MANUFACTURER CAPACITY (INCHES DIAMETER) MARK & MODEL SERVICE TYPE (CFM) VOLTS./PH,/HZ LENGTH WIDTH HEIGHT WEIGHT NOTES .0AMPS. (IN) (IN) (IN) (LB) o SUPPLY AND Q ATTIC >=3 R-8 120/1/60 c oo N RETURN REFER TO KH-1 KITCHEN HOOD EXHAUAST 300 DEDICATED 15 36 22 6 100 1. ARCHITECTURAL AMP CIRCUIT k SUPPLY AND - DRAWN BY: BC o ATTIC RETURN <3 R-6 1. HOOD SHALL COME WITH INTEGRAL BLOWER, 6 INCH DIAMETER DUCT COLLAR, AND DISCONNECT SWITCH. CHECKED BY: TH OUTSIDE THE EBUILDING SUPPLY AND THERMAL RETURN >-3 R-6 0 Q ENVELOPE 1ELECTRIC RESISTANCE UNIT HEATER SCHEDULE SCALE:NONE o OUTSIDE THE BUILDING SUPPLY AND <3 R-4.2 ELECTRICAL THERMAL RETURN MANUFACTURER & MODEL OPER WT. Mechanical • ENVELOPE UNIT TAG NUMBER SERVICE LOCATION CFM CAPACITY TOTAL V PH HZ (LBS) NOTES Schedules & INSIDE THE (KW) AMPS ° BUILDING SUPPLY AND THERMAL RETURN ALL NONE Details ENVELOPE UH-1 INDEECO UHIR GARAGE GARAGE 350 5 21 240 1 60 15 1. 1 N 1. PER IRC SECTION N1103.3 (R403.3). NOTES: 2. ALL INSULATION MATERIALS SHALL BE PLENUM RATED. 1. FURNISH WITH FACTORY DISCONNECT SWITCH, INTEGRAL SINGLE STAGE THERMOSTAT, AND WALL BRACKET FINISH SHALL BE FACTORY WHITE. I'A-6 O 1 1 0 3. DUCT WRAP INSTALLED THICKNESS SHALL BE CONSIDERED 75% OF THE NOMINAL N THICKENESS.