HomeMy WebLinkAboutB17-0114_ResCheck_1496872862.pdf GComplianceenerated by REScheck-WebCertificate Software Project 4367 COLUMBINE DRIVE Energy Code: 2015 IECC Location: Eagle County, Colorado Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: 4,500 ft2 Glazing Area 13% Climate Zone: 6 (8499 HDD) Permit Date: Permit Number: Construction Site: Owner/Agent: Designer/Contractor: Compliance:Passes using UA trade-off Compliance: 17.1%Better Than Code Maximum UA: 621 Your UA: 515 The%Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Envelope Assemblies Gross Area Cavity Cont. Assembly or R-Value R-Value U-Factor UA Perimeter Ceiling: Cathedral 2,364 30.0 16.0 0.022 52 S &W Walls: Wood Frame, 16in. o.c. 3,397 14.0 16.0 0.034 89 Window: Wood Frame,Triple Pane 692 0.250 173 Door: Glass 65 0.250 16 Door: Solid 28 1.500 42 E & N Walls: Wood Frame, 16in. o.c. 2,385 16.0 12.0 0.036 86 Basement: Solid Concrete or Masonry 1,626 12.0 10.0 0.034 55 Wall height: 10.8' Depth below grade: 10.0' Insulation depth: 10.8' Floor: All-Wood joist/Truss Over Outside Air 94 30.0 16.0 0.021 2 Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application.The proposed building ha been d igne to meet the 2015 IECC requirements in R Sic eck Version 5.5.0fqcomply with the mandatory re ire e Sc ck Inspection4 i Name Title ' Signature ate Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 1 of 9 0 REScheck Software VersionChecklist 5.5.0 Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the REScheck software Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section Plans Verified Field Verified # Pre-Inspection/Plan Review Value Value Complies? Comments/Assumptions & Req.ID 103.1, Construction drawings and ElComplies 103.2 documentation demonstrate ❑Does Not [PR1]' energy code compliance for the ,, building envelope.Thermal ❑Not Observable envelope represented on ❑Not Applicable construction documents. 103.1, Construction drawings and ❑Complies 103.2, documentation demonstrate ❑Does Not 403.7 energy code compliance for [PR3]1 lighting and mechanical systems. [Not Observable Systems serving multiple ❑Not Applicable dwelling units must demonstrate compliance with the IECC Commercial Provisions. 302.1, Heating and cooling equipment is Heating: Heating: EComplies 403.7 sized per ACCA Manual S based Btu/hr ; Btu/hr ❑Does Not [PR2]2 on loads calculated per ACCA Cooling: Cooling: Manual J or other methods ❑Not Observable Btu/hr Btu/hr approved by the code official. ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 2 of 9 Section Plans Verified Field Verified # Foundation Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1 Conditioned basement wall R- R- '❑Complies See the Envelope Assemblies [F04]1 insulation R-value.Where interior R_ R- ❑Does Not table for values. insulation is used, verification may need to occur during ❑Not Observable Insulation Inspection. Not ❑Not Applicable required in warm-humid locations in Climate Zone 3. 303.2 Conditioned basement wall EComplies [F05]1 insulation installed per ❑Does Not manufacturer's instructions. [Not Observable ❑Not Applicable 402.2.9 Conditioned basement wall ft ft ❑Complies See the Envelope Assemblies [F06]1 insulation depth of burial or El Does Not • table for values. distance from top of wall. ❑Not Observable ❑Not Applicable 303.2.1 A protective covering is installed EComplies [F011]2 to protect exposed exterior ❑Does Not insulation and extends a minimum of 6 in. below grade. ['Not Observable ❑Not Applicable 403.9 Snow-and ice-melting system ❑Complies [F012]2 controls installed. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 3 of 9 Section Plans Verified Field Verified # Framing/ Rough-In Inspection Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Door U-factor. ' U- U- Complies See the Envelope Assemblies 402.3.4 Does Not table for values. [FR1]1 ['Not Observable ❑Not Applicable 402.1.1, Glazing U-factor(area-weighted U- U- ❑Complies See the Envelope Assemblies 402.3.1, average). ❑Does Not table for values. 402.3.3, 402.3.6, ['Not Observable 402.5 ❑Not Applicable [FR2]1 303.1.3 U-factors of fenestration products ❑Complies [FR4]1 are determined in accordance ❑Does Not with the NFRC test procedure or taken from the default table. ❑Not Observable DNot Applicable 402.4.1.1 Air barrier and thermal barrier ❑Complies [FR23]1 installed per manufacturer's ElDoes Not instructions. [Not Observable ❑Not Applicable 402.4.3 Fenestration that is not site built ❑Complies [FR2011 is listed and labeled as meeting ❑Does Not AAMA/WDMA/CSA 101/I.S.2/A440 • or has infiltration rates per NFRC ❑Not Observable 400 that do not exceed code ❑Not Applicable limits. 402.4.5 IC-rated recessed lighting fixtures ❑Complies [FR16]2 sealed at housing/interior finish ❑Does Not and labeled to indicate s2.0 cfm leakage at 75 Pa. ['Not Observable ❑Not Applicable 403.2.1 Supply and return ducts in attics ❑Complies [FR12]' insulated >= R-8 where duct is ❑Does Not • >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and ❑Not Observable return ducts in other portions of ❑Not Applicable the building insulated >= R-6 for diameter >= 3 inches and R-4.2 • for< 3 inches in diameter. 403.3.3.5 Building cavities are not used as ❑Complies [FR15]3 ducts or plenums. ❑Does Not ['Not Observable ❑Not Applicable 403.4 HVAC piping conveying fluids R- R- ❑Complies [FR17]2 above 105°F or chilled fluids •❑Does Not below 55 °F are insulated to 3 ❑Not Observable ❑Not Applicable 403.4.1 ;Protection of insulation on HVAC ❑Complies • [FR24]1 piping. ❑Does Not • ['Not Observable ❑Not Applicable 403.5.3 Hot water pipes are insulated to R- R- ❑Complies [FR18]2 >_R-3. ❑Does Not ONot Observable ❑Not Applicable 403.6 Automatic or gravity dampers are ❑Complies [FR19]2 installed on all outdoor air ❑Does Not intakes and exhausts. ❑Not Observable ❑Not Applicable 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 4 of 9 Additional Comments/Assumptions: 1 High Impact (Tier 1) L_21. Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 5 of 9 Section Plans Verified Field Verified # Insulation Inspection Value Value Complies? Comments/Assumptions & Req.ID 303.1 All installed insulation is labeled ❑Complies [IN13]2 or the installed R-values ❑Does Not provided. [Not Observable ENot Applicable 402.1.1, Floor insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.6 ❑ Wood ❑ Wood ❑Does Not table for values. [IN 111 ❑ Steel ❑ Steel ❑Not Observable ❑Not Applicable 303.2, Floor insulation installed per ❑Complies 402.2.7 manufacturer's instructions and ❑Does Not [IN2]1 in substantial contact with the underside of the subfloor, or floor [Hot Observable framing cavity insulation is in :Not Applicable contact with the top side of sheathing, or continuous insulation is installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. 402.1.1, Wall insulation R-value. If this is a R- R- ❑Complies See the Envelope Assemblies 402.2.5, mass wall with at least 1/2 of the ❑ Wood ❑ Wood ❑Does Not ,table for values. 402.2.6 wall insulation on the wall ❑ Mass ❑ Mass [Not Observable [IN3]1 exterior, the exterior insulation requirement applies(FR10). ❑ Steel El Steel ❑Not Applicable 303.2 Wall insulation is installed per ❑Complies [IN4]' manufacturer's instructions. ❑Does Not ❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 6 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 402.1.1, Ceiling insulation R-value. R- R- ❑Complies See the Envelope Assemblies 402.2.1, Li Wood ❑ Wood ❑Does Not table for values. 402.2.2, El Steel ❑ Steel 402.2.6 ❑Not Observable [FI1]' ❑Not Applicable 303.1.1.1, Ceiling insulation installed per ❑Complies 303.2 manufacturer's instructions. ❑Does Not [FI2]' Blown insulation marked every 300 ft2. ❑Not Observable ❑Not Applicable • 402.2.3 Vented attics with air permeable ❑Complies [F122]2 insulation include baffle adjacent ❑Does Not to soffit and eave vents that extends over insulation. [L]Not Observable ❑Not Applicable 402.2.4 Attic access hatch and door R- R- ❑Complies [F13]' insulation ?R-value of the ❑Does Not adjacent assembly. ['Not Observable ❑Not Applicable 402.4.1.2 Blower door test @ 50 Pa. <=5 ACH 50 = ACH 50 = '❑Complies [F117]1 ach in Climate Zones 1-2, and ❑Does Not <=3 ach in Climate Zones 3-8. ❑Not Observable ❑Not Applicable 403.2.3 Duct tightness test result of<=4 cfm/100 cfm/100 ❑Complies [F14]' cfm/100 ft2 across the system or ft2 ft2 ❑Does Not <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in ❑Not Observable tests, verification may need to ElNot Applicable occur during Framing Inspection. 403.3.2 Ducts are pressure tested to cfm/100 cfm/100 ❑Complies [F127]' determine air leakage with ft2 ft2 El Does Not either: Rough-in test:Total leakage measured with a ['Not Observable pressure differential of 0.1 inch ❑Not Applicable w.g. across the system including the manufacturer's air handler enclosure if installed at time of test. Postconstruction test:Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer's air handler enclosure. 403.3.2.1 Air handler leakage designated ❑Complies [FI24]' by manufacturer at <=2%of ❑Does Not design air flow. ❑Not Observable I ❑Not Applicable ; 403.1.1 Programmable thermostats ❑Complies [Fl9]2 installed for control of primary ❑Does Not heating and cooling systems and initially set by manufacturer to ❑Not Observable code specifications. ❑Not Applicable 403.1.2 Heat pump thermostat installed EComplies [F110]2 on heat pumps. ❑Does Not ❑Not Observable ❑Not Applicable 403.5.1 Circulating service hot water ❑Complies [F111]2 systems have automatic or ❑Does Not accessible manual controls. ENot Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 7 of 9 Section Plans Verified Field Verified # Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 403.6.1 All mechanical ventilation system ❑Complies [F12512 fans not part of tested and listed ❑Does Not HVAC equipment meet efficacy and air flow limits. ❑Not Observable ❑Not Applicable 403.2 Hot water boilers supplying heat ❑Complies [F126]2 through one-or two-pipe heating ❑Does Not systems have outdoor setback control to lower boiler water ❑Not Observable temperature based on outdoor ❑Not Applicable temperature. _ 403.5.1.1 Heated water circulation systems ❑Complies [FI28]2 have a circulation pump.The ❑Does Not system return pipe is a dedicated return pipe or a cold water supply ❑Not Observable pipe.Gravity and thermos- ❑Not Applicable syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. 403.5.1.2 Electric heat trace systems ElComplies [F129]2 comply with IEEE 515.1 or UL ❑Does Not 515.Controls automatically adjust the energy input to the [Not Observable heat tracing to maintain the ❑Not Applicable desired water temperature in the piping. 403.5.2 Water distribution systems that ❑Complies [F130]2 have recirculation pumps that ❑Does Not pump water from a heated water supply pipe back to the heated ❑Not Observable water source through a cold ❑Not Applicable water supply pipe have a demand recirculation water system.Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 1042F. 403.5.4 Drain water heat recovery units EComplies [F13112 tested in accordance with CSA ❑Does Not B55.1.Potable water-side pressure loss of drain water heat ['Not Observable recovery units<3 psi for ❑Not Applicable individual units connected to one or two showers.Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. 404.1 75%of lamps in permanent ❑Complies (FI6]1 fixtures or 75%of permanent ❑Does Not fixtures have high efficacy lamps. Does not apply to low-voltage ['Not Observable lighting. ❑Not Applicable 404.1.1 Fuel gas lighting systems have ❑Complies [F123]3 no continuous pilot light. :❑Does Not ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 8 of 9 Section Plans Verified Field Verified Final Inspection Provisions Value Value Complies? Comments/Assumptions & Req.ID 401.3 Compliance certificate posted. EComplies [FI7]2 ElDoes Not ❑Not Observable ENot Applicable 303.3 Manufacturer manuals for ❑Complies [F118]3 mechanical and water heating ❑Does Not systems have been provided. ['Not Observable ENot Applicable , Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: 4367 COLUMBINE DRIVE Report date: 04/19/17 Data filename: Page 9 of 9 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value Above-Grade Wall 30.00 Below-Grade Wall 22.00 Floor 46.00 Ceiling / Roof 46.00 Ductwork (unconditioned spaces): Glass &Door Rating U-Factor SHGC Window 0.25 Door 0.25 Heating&Cooling Equipment Efficiency Heating System: Cooling System: Water Heater: Name: Date: Comments