HomeMy WebLinkAboutB17-0161_A0.1_1504018429.pdfUP
U
DN
D W
DN
DN
UP
UP
DN
UP
DN
UP
DN
DN
24"COTTONWOOD
EDGEOFASPHALT
DAVOS TRAIL
LOT
18
EDGE OF CONCRETE
BLOCK B
ASPEN GROVE4" PINE
6" PINE
8" PINE
8" PINE
TV PEDINE
FOUND 11_
2"BLANK
ALUMINUM
CAP
FOUND REBAR
EDGE OFFOUND #5REBARWITHWASHER
North
42'
44'
46'
48'
50'
52'
54'
56'
58'
60'
66'
68'
70'
34'
32'
40' 32'
34'
36'
38'
42'
44'
46'
48'
50'
40'
52'
54'
56'
58'
60'
68'
70'
28'
30'
56'
56'
55' OULDER WALLCULVERT INLET
15' SIDE
SETBACK
15'
SIDE
SETBACK
15' BACK SETBACK
20'
FRONT
SETBACK
7'
UTILITY
EASEMENT
RECEPTION
NO.
103252
P
Q
TV
8030
8040
8050
8060
8070
UP
DN
DN
DN
DN
DN
DN
UP
DN
UP
DN
1723 SF
'A' Garage and Lower
Level Area
1017.2
SF
'B' Garage and Lower
Level Area
10' - 3 1/2"
PARTY
WALL
WALL
1704 SF
'A' Main Level Area
1189.2
SF
'B' Main Level Area
PARTY
WALL
1227.9
SF
'A' Upper Level Area
1204.1
SF
'B' Upper Level Area
PARTY
WALL
3122.9
SF
Lot Coverage
(total max. 3154 s.f.)
26' - 0"
1
A4.2
overhang of garage roof
3' - 11"
TERRACES AND WALKS
1400 S.F.
2
A4.2
26 SF
Area of overhang over
4'-0"
4' - 6 3/4"
LINE OF GARAGE BELOW
LINE OF MASTER ABOVE 1' - 0"
4' - 0"
4' - 9 5/8"
PARTY
WALL
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
7/5/2017
3:35:22 PM
A0.1 AREA
PLANS
1670
2655
Davos
Trail
PERMIT
SET
04-28-17
Custom
Duplex at Vail Colorado
1/8" = 1'-0"
1 A1.0 LOWER LEVEL
1/8" = 1'-0"
2
A2.0 MAIN LEVEL
1/8" = 1'-0"
3 A3.0 UPPER LEVEL
1/8" = 1'-0"
4
SITE COVERAGE
Area Schedule (west unit 'A')
Name Area
'A' Garage and Lower Level Area 1723 SF
'A' Main Level Area 1704 SF
'A' Upper Level Area 1227.9 SF
Grand total: 3 4654.9 SF
Total of lower levels within 6'-0" of lowest slab ht
MUTIPLY x% OF BURIED FOUNDATION WALL
SUBTRACT 600 S.F. FOR GARAGE
Zone District: Primary / Secondary Residential
Lot Area: .362 acres x 43,560 s.f. = 15,769 s.f.
• GRFA Allowed: .46% lot area < 10,000 s.f. = 4,600 s.f.
.38% lot area < 15,000 s.f. = 1,900 s.f.
.13% lot area (769 s.f.) = 100 s.f.
Total = 6,600 s.f.
• Primary/Secondary Split: 60% = 3,960 s.f. 40% = 2,640 s.f.
• Site Coverage (20%) = 3,154 s.f. (includes roof overhangs over 4’ deep)
• Height Limitation= 33 feet (as measured from existing grade directly to ridge above)
SEE SHEET A0.2 FOR GRFA CALCULATIONS
Area Schedule (east unit 'B')
Name Area
'B' Garage and Lower Level Area 1017.2 SF
'B' Main Level Area 1189.2 SF
'B' Upper Level Area 1204.1 SF
Grand total: 3 3410.4 SF
No. Description Date
Contractor must
submit for a PW
Permit for new site
access to a vacant
lot. Prior to to the
start of project.
08/29/17