HomeMy WebLinkAboutB17-0161_A5.1_1504018436.pdfR-19 (MIN) BLOWN-IN
INSULATION TO FILL 2X STUD
FURRING WALL CAVITY.
GYPSUM WALL BOARD HELD UP
FROM SLAB 3/8"
TREATED WOOD BOTTOM
PLATE SEALANT UNDER PLATE
FOR CAPILLARY BREAK.
(R-10) UNDER-SLAB
INSULATION
HEATED CONCRETE SLAB
(IN-FLOOR RADIANT HEATING SYSTEM)
GRANULAR FILL - INCLUDE
SOIL-GAS VENTILATION
SYSTEM
REFER TO STRUCTURAL DRAWINGS
FOR FOUNDATION/FOOTING DESIGN
AND REINFORCEMENT
(R-5) 3/4" RIGID INSULATION
FOR THERMAL BREAK
SLOPED 4" PERFORATED DRAIN
PIPE. ALL FOUNDATION WALLS
INCLUDING INTERIOR WALLS.
RE: SOILS REPORT
COARSE GRANULAR FILL
FILTER FABRIC
DAMPROOFING OR W.P.
MEMBRANE FOR
CAPILLARY BREAK
FREE-DRAINING BACKFILL
(R-10) 2-3/8" DRAIN & DRY" DRAINAGE
BOARD OVER WATERPROOFING (FROM
FOOTING TO 8" BELOW FINISHED GRADE)
5/8" TYPE "X" GYPSUM
WALL BOARD
SLOPED 4" SOLID DRAIN
FROM GUTTER &
DOWNSPOUT UNDER-
DRAIN SYSTEM. (MAY BE
LOCATED HIGHER, BUT AT
LEAST 4'-0" BELOW
FINISHED GRADE NEAR
BUILDING)
ALTERNATE SYSTEM:
COMPOSITE DRAINAGE BOARD WITH
FILTER FABRIC EXTEND FROM 8" BELOW
GRADE TO FOOTING OVER 2" RIGID
INLSULATION (TO A DEPTH OF 4'-0"
BELOW GRADE) OVER WATERPROOFING.
INTERIOR SPACE
BASE TRIM
ADDITIONAL 4" PERFORATED DRAIN
PIPE AT 10'-0" VERTICAL SPACING AT
ALL UPHILL FOUNDATION WALLS IN
EXCESS OF 15' IN HT
WATERPROOF MEMBRANE TO EXTEND FROM
FOOTING TO 6" ABOVE FINISHED GRADE
1
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
PARTY
WALL
GA FILE NO. WP 3810
BASE LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
APPLIED AT RIGHT ANGLES TO 2X6 WOOD STUDS AT
24" O.C. WITH 6d COATED NAILS, 1 7/8" LONG. 1/4"
HEADS, 16" O.C.
FACE LAYER: 5/8" SOUNDBREAK XP APPLIED AT RIGHT
ANGLES TO STUDS OVER BASE LAYER AND TOP AND
BTM PLATES WITH 8d COATED NAILS, 2 3/8" LONG,
0.099" SHANK, 9/32" HEADS, 8" O.C. JOINTS OFFSET 24"
FROM BASE LAYER JOINTS.
INNER LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
WITH 6d COATED NAILS, 1 7/8" LONG, .0915 SHANK, 1/4"
HEADS, 8" O.C. JOINTS IN INNER LAYER NEED NOT BE
TAPED.
SECOND WALL DUPLICATED OF FIRST WALL AND
SEPARATED BY 1 3/4" SPACE. WALLS ARE
INDEPENDANTLY LOADED. WALLS TO RECIEVE
5 1/2" BLOWN-IN INSULATION. (LOAD BEARING)
LANDINGE300
MASTER
BEDROOM
W205
LIVING
E200
3"
7"
7"
1 3/4"
JR. SUITE
BEDROOM
W107
GARAGE
E100
4' - 0"
5/8" GWB APPLIED TO THE
UNDER SIDE OF ROOF
SHEATHING FOR A DISTANCE
OF 4'-0" FROM PARTY WALL AT
LOCATION WHERE THE ROOF
PLANES ARE LESS THAN 30"
PROVIDE 5/8" TYPE 'X'
GYPSUM WALL BOARD
AT RIM JOIST
SO THAT THE WALL
ASSEMBLY HAS A TOTAL
OF 2 LAYERS FOR
HEIGHT OF WALL
PROVIDE 5/8" TYPE 'X'
GYPSUM WALL BOARD
AT RIM JOIST
SO THAT THE WALL
ASSEMBLY HAS A TOTAL
OF 2 LAYERS FOR
HEIGHT OF WALL
A3.0 UPPER LEVEL
8057' - 9"
A1.9 MASTER LVL
8045' - 10"
East-West High
Plate Height
8070' - 6"
1' - 2"
OVERHANG
1' - 6" BLOCK BCI WEB AT
BEARING POINTS
1 1/2"
SLOPED BLOCKING
'D' SHAPED DRIP FLASHING
(LEG LONG ENOUGH TO COVER 2X6 FASCIA)
WITH DRIP HEM AT BOTTOM
2x12 FASCIA
ALUM. SOFFIT VENT WITH
BUG SCREEN.
PROVIDE AT BOTH AT
LOW SIDE OF ROOF AND
AT HIGH
TL ASPHALT SHINGLES ON FULL COVERAGE WATERPROOF
MEMBRANE ON ROOF SHEATHING ON 12 1/2" BCI/LVL ROOF
RAFTERS WITH BLOWN-IN BATT R-59.22 INSULATION BETWEEN
RAFTERS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL
BOARD ON CEILING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
HEAD FLASHING AT ALL WINDOW AND DOOR HEADS
VERTICAL WOOD SIDING ON THERMAL AND AIR INFILTRATION
BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL
FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN
STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X'
GYPSUM WALL BOARD ON WALL
VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS.SHIM
SPACE
1"
SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS
see strcut for min.
11"
1' - 0" 2" WATERPROOF MEMBRANE TO TURN DOWN AND OVERLAP FASCIA
WATER PROOF MEMBRANE FROM DECK TO TURN UP WALL MINIMUM OF 2'-0". EXTEND UNDER DOOR THRESHOLDS, LAP DOOR THRESHOLD VYCOR OVER
DRAINAGE MEDIUM IS TO STOP
3" FROM EDGE. PROVIDE ROPE
WICKS AT 2'-0" O.C. ALONG EDGE
EDGE FLASHING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
5/8" TYPE 'X' GYPSUM WALL BOARD
VYCORE TAPE NAILING FLANGE AT TOP OF WINDOW
SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS
STEP DOWN FROM
INTERIOR TO EXTERIOR 1/2" TO 1"
BOTTOM OF WALL FLASHING
2x14 DECK EDGE
1x6 T&G SOFFIT
ALUM CLAD WOOD WINDOW
4" MAXIMUM
SPACING TO BTM
RAIL
VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS.
1x6 T&G SOFFIT
STONE VENEER ON DRAINAGE MEDIUM SYSTEM ON
THERMAL AND AIR INFILTRATION BARRIER ON 1/2"
SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH
BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM
WALL BOARD ON WALL
8043' - 6"
8043' - 7"
ENTRY
W106
ENTRY
W106
FAMILY
W300
FAMILY
W300
LANDINGW204
R-58 BLOWN-IN BATTS INSULATION 3"
3"
12' - 9"
METAL PANEL SYSTEM
WITH CONCEALED FASTENERS 3"
9 1/4" 8068' - 1"
9' - 8" 3/4" 9 1/4" 2 1/4" 1' - 2 3/4"
11' - 11"
MC 10x8.4 STEEL CHANNEL AT EDGE OF DECKS 3"
SPACER AT
GUARD
CONNECTION
CORRUGATED AIR BAFFLE
1x6 T&G SOFFIT
1 1/2" AIR GAP
LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB
WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE
MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF
MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30 SPRAY
FOAM INSUALTION AND BATT INSULATION BETWEEN JOISTS.
East Partywall Plate
Height
8063' - 1"
PARTY
WALL
5/8" GWB APPLIED TO THE
UNDER SIDE OF ROOF
SHEATHING FOR A DISTANCE
OF 4'-0" FROM PARTY WALL AT
LOCATION WHERE THE ROOF
PLANES ARE LESS THAN 30"
PROVIDE 5/8" TYPE 'X' GWB TO
THE UNDERSIDE OF THE
OVERHANG AND UNDER
FASCIA TO CREATE A FIRE
PROTECTED OVERHANG
SUBSTITUTE THE 1/2" EXTERIOR PLYWOOD
WALL SHEATHING WITH EXTERIOR GWB
FOR PORTION OF WALL THAT FACES WEST
LARGE RECTILINEAR STONE TILE ON
MORTAR ON 3" CONCRETE SLAB WITH
RADIANT HEATING SYSTEM TUBING ON J
DRAIN 1000 DRAINAGE
MEDIUM/PROTECTION (OR SIMILAR) ON 2
LAYERS OF WATERPROOF MEMBRANE ON
3/4" SHEATHING ON SLOPING TOP CUT
LVLS. R-30+ BLOWN IN BATTS INSULATION
BETWEEN JOISTS.
BOTTOM OF WALL FLASHING
'D' SHAPED DRIP FLASHING
(LEG LONG ENOUGH TO COVER 2X6 FASCIA)
WITH DRIP HEM AT BOTTOM
WATERPROOF MEMBRANE
TO TURN DOWN AND
OVERLAP FASCIA
1 1/2"
GA FILE NO. WP 3810
BASE LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
APPLIED AT RIGHT ANGLES TO 2X6 WOOD STUDS AT
24" O.C. WITH 6d COATED NAILS, 1 7/8" LONG. 1/4"
HEADS, 16" O.C.
FACE LAYER: 5/8" SOUNDBREAK XP APPLIED AT RIGHT
ANGLES TO STUDS OVER BASE LAYER AND TOP AND
BTM PLATES WITH 8d COATED NAILS, 2 3/8" LONG,
0.099" SHANK, 9/32" HEADS, 8" O.C. JOINTS OFFSET 24"
FROM BASE LAYER JOINTS.
INNER LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
WITH 6d COATED NAILS, 1 7/8" LONG, .0915 SHANK, 1/4"
HEADS, 8" O.C. JOINTS IN INNER LAYER NEED NOT BE
TAPED.
SECOND WALL DUPLICATED OF FIRST WALL AND
SEPARATED BY 1 3/4" SPACE. WALLS ARE
INDEPENDANTLY LOADED. WALLS TO RECIEVE
5 1/2" BLOWN-IN INSULATION. (LOAD BEARING)
3"
BOTH WALLS ARE INDEPNDANTLY BEARING AND THE ROOF
AND ROOF OVERHANG IS COVERED IN 5/8" TYPE 'X' GWB
PROVIDING THE FIRE SEPARATION PROTECTION FROM EACH
UNIT
SEE STRUCTURAL DETAIL
FOR BLOCKING AND
ANCHORAGE
PROVIDE 5/8" TYPE 'X' GYPSUM WALL BOARD AT
RIM JOIST SO THAT THE WALL ASSEMBLY HAS A
TOTAL OF 2 LAYERS FOR HEIGHT OF WALL
SPRAY FOAM INSUALTION ON
UNDERSIDE OF STRUCTURAL ROOF
SHEATHING/GWB (R-30 AT 4.5") AND
10" FIBERGLASS BATT INSUALTION
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
7/5/2017
3:36:00 PM
A5.1 DETAILS
1670 2655
Davos
Trail
PERMIT
SET
04-28-17
Custom
Duplex at Vail Colorado
1" = 1'-0" 3 TYPICAL FOUNDATION DETAIL
1" = 1'-0"
4 PARTY WALL SECTION
1 1/2" = 1'-0"
5
WALL SECTION AT WEST UNIT, SOUTH
WALL
1" = 1'-0"
1
WALL SECTION AT PARTYWALL WITH
ROOF OVERHANG
No. Description Date
1 Revision 1- BUILDING
DEPT COMMENTS
7-5-17
1
1