HomeMy WebLinkAboutB17-0161_A5.2_1504018380.pdfA2.0 MAIN LEVEL
8047' - 0"
1 1/2"
'D' SHAPED DRIP FLASHING
(LEG LONG ENOUGH TO COVER 2X6 FASCIA)
WITH DRIP HEM AT BOTTOM
2x12 FASCIA
TL ASPHALT SHINGLES ON FULL COVERAGE WATERPROOF
MEMBRANE ON ROOF SHEATHING ON 14" BCI/LVL ROOF
RAFTERS, CORREGATED AIR BAFFEL, WITH BLOWN-IN BATT
R-52.22 INSULATION BETWEEN RAFTERS.MEMBRANE VAPOR
RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON CEILING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS.
SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS
WATERPROOF MEMBRANE TO TURN DOWN AND OVERLAP FASCIA
ALL TRAPAZOIDE WINDOWS ARE TO BE FIELD VERIFIED FOR SIZE AND SLOPE.
TRAPAZIODE WINDOWS TYPICALLY SHOULD BE THE SAME SLOPE AS THE
ROOF/CEILING ABOVE.
COORDINATE THE TRANSOM WINDOW SIZES SO THAT THE OVERALL WIDTH
MATCHES THAT OF DOORS BELOW
PLACE 3/4" RIGID INSULATION IN
PLANCE OF 5/8" GYPSUM WALL BOARD
UNDER TRIM AT LOCATION BETWEEN
WINDOWS WITH STEEL HEADER
HORIZONTAL METAL PANEL CLOSURE PIECE BETWEEN WINDOWS
1' - 0" 2"
LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB
WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE
MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF
MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30 SPRAY
FOAM INSUALTION AND BATT INSULATION BETWEEN JOISTS.
DRAINAGE MEDIUM IS TO STOP
3" FROM EDGE. PROVIDE ROPE
WICKS AT 2'-0" O.C. ALONG EDGE
EDGE FLASHING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
BOTTOM OF WALL FLASHING AT LOCATIONS WITHOUT DOOR
MC 10X8.4 STEEL CHANNEL AT EDGE OF DECKS
1x6 T&G SOFFIT
3"
WATERPROOF MEMBRANE FROM DECK TO TURN UP
WALL MINIMUM OF 2'-0". EXTEND UNDER DOOR
THRESHOLDS, LAP DOOR THRESHOLD VYCOR OVER
TRESHOLD, SET IN SEALANT
5' - 6"
3"
3' - 11" STONE VENEER ON DRAINAGE MEDIUM SYSTEM ON
THERMAL AND AIR INFILTRATION BARRIER ON 1/2"
SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH
BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM
WALL BOARD ON WALL
3" STONE WALL CAP, SLOPE TO EXTERIOR
4' - 6 1/2"
1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH
BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL
BOARD ON WALL
HORIZONTAL WOOD SIDING ON THERMAL AND AIR INFILTRATION
BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL
FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN
STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X'
GYPSUM WALL BOARD ON WALL
WEATHERSTRIPPING AT HEAD AND JAMBS OF GARAGE DOOR
SEMI-TRANSLUCENT GLASS PANELS IN ALUM. OVERHEAD DOOR
(REVIEW BELT LIFT FOR QUIETER OPERATION)
STOP INSULATION TO TEMPER THE VOID UND THE HEATED DECK
3" SLAB
2 1/4".
minimum
see struct for
SPACER AT
GUARD
CONNECTION
W12x26
INSULATE EAVES AT
LOCATIONS WITH STEEL
BEAMS IN ROOF PLANE
1
1
DRAINAGE MEDIUM IS TO STOP
3" FROM EDGE. PROVIDE ROPE
WICKS AT 2'-0" O.C. ALONG EDGE
EDGE FLASHING
MC 10X8.4 STEEL CHANNEL AT EDGE OF DECKS
SPACER AT
GUARD
CONNECTION
3 3/4" 2" 3' - 0 1/4"
2 7/8"
3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 2 7/8"
2"
1 3/4"IPEA TOP CAP WITH
SLOPED TOP
2" TUBE STEEL, PAINTED
(BLACK)
1 1/2"x3/8" STEEL BAR STOCK
3"
3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 2" TUBE STEEL, PAINTED
(BLACK)
1 1/2"x3/8" STEEL BAR STOCK
3/4"
2 1/4" 3 3/4"
3/8" 1 3/4"
2"x3/8" STEEL BAR STOCK
2"x3/4" STEEL BAR STOCK
GRASPABLE RAILING
EASE ALL EDGES SO THAT
THEY ARE SMOOTH
3' - 0 1/2"
INTERIOR GUARD
3 7/8"
3' - 0 1/2"
INTERIOR STAIR RAILING
3 11/16"
11"
1' - 0"
2' - 5 5/8"
2"3/8"
3 3/4
"3 3/4"3 3/4"3 3/4"3 3/4"3 3/4"
1 3/4"3/4"
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
7/13/2017
4:01:10 PM
A5.2 DETAILS
1670 2655
Davos
Trail
PERMIT
SET
04-28-17
Custom
Duplex at Vail Colorado
1 1/2" = 1'-0"
1
WALL SECTION AT WEST UNIT, LIVING
ROOM ROOF AND DECK, SOUTH WALL
No. Description Date
1 Revision 1- BUILDING
DEPT COMMENTS
7-13-17
1" = 1'-0"
2 EXTERIOR GUARD DETAIL
INTERIOR RAILS AND GUARD DETAIL ARE SIMILAR
1
1" = 1'-0"
3 INTERIOR GUARD AND RAILING
08/29/17