HomeMy WebLinkAboutB17-0161_A6.0_1504018438.pdfREF.
DW
W D
DW
2
A4.1
1
A4.2
4
A4.2
3
A4.1 1
A4.1
2
A4.3
2
A4.2
3
A4.2
1
A4.3
4
A4.1
2
A4.4
1
A4.4
PARTY
WALL
crawlspace
PROVIDE VAPOR
BARRIER OVER GRADE
AND UP FOUNDATION
WALL AT LEAST 6" AND
TAPE/SEAL TO WALL.
R-13 ON THE
EXTERIOR WALLS OF
CRAWLSPACE. R-49 IN
THE FLOOR JOISTS
ABOVE. (VAPOR
BARRIER AGAINST THE
FLOOR SHEATHING)
SD
CM
D
A A
A A
D
SD
TO LIGHTS ON
LANDING AND
SWITCH
ABOVE
D L
L
L L A.Sub-Flr
dropped ceiling
10' - 7"
A.Sub-Flr
dropped ceiling
11' - 7"
A.Sub-Flr
dropped ceiling
10' - 7"
A.Sub-Flr
dropped ceiling
9' - 7"
A.Sub-Flr
dropped ceiling
9' - 1"
ceiling at btm of
structure above
10'-1"
E
A
D
D D G G G
J
t
K
K
K K
K
J
J
E E E
A wp A wp A wp
A A
A A
D D
D
D
TO SCONCE
LIGHT,
LANDING
RECESSED
AND SWITCH
ABOVE
K
K
K K
K K
D
KEYLESS
FIXTURE IN
CRAWL
3'x3' ACCESS DOOR INTO CRAWLSPACE
L
L
L
L L
TO LANDING
STEP LIGHTS
AND ENTRY
LIGHTS ABOVE
gfci
gfci
SD CM
SD
CM
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
A wp
D
E
F
G
J
K
L
5" RECESSED CAN LIGHT (wet location)
5" RECESSED CAN LIGHT (sloped ceiling fixture)
5" RECESSED CAN LIGHT (directional spot)
CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT)
A
5" RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
H
FLUORESCENT CLOSET LIGHT
BATH FAN
2x4 FLUORESCENT FIXTURE
SURFACE MOUNT
STEP LIGHT
M
COVE LIGHTING (LED TAPE)
1/2 HOT DUPLEX OUTLET
NOTES:
1 PROVIDE DOOR BELL CHIME AT EACH LEVEL.
2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE
LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR
3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE
DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL
4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS
B
C
t
THERMOSTAT
SD
CM
SMOKE DETECTOR
CO SENSOR/DETECTOR
SWITCH
INTERIOR LIGHTING NOTE
GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
ARC-FAULT CIRCUIT INTERRUPTER
AFCI protection is required on all branch circuits supplying
outlets or devices installed in dwelling unit kitchens, family
rooms, dining rooms, living rooms, parlors, libraries, dens,
bedrooms, sunrooms, recreation rooms, closets, hallways,
laundry areas, and similar rooms and areas.
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15
AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A
COVER AND WEATHERPROOF WHILE IN USE OT NOT
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
7/13/2017
4:01:11 PM
A6.0 LOWER
LEVEL
RCP
1670 2655
Davos
Trail
PERMIT
SET
04-28-17
Custom
Duplex at Vail Colorado
1/4" = 1'-0"
1
A1.0 LOWER LEVEL RCP AND ARCH
LIGHTING PLAN
1/4" = 1'-0"
ELECTRICAL LEGEND
No. Description Date
1 Revision 1- BUILDING
DEPT COMMENTS
7-13-17
08/29/17