HomeMy WebLinkAboutB17-0161_A6.1_1504018439.pdfREF.
DW
W D
REF. REF.
DW
2
A4.1
1
A4.2
4
A4.2
3
A4.1 1
A4.1
2
A4.3
2
A4.2
3
A4.2
1
A4.3
4
A4.1
2
A4.4
1
A4.4
PARTY
WALL
A
D 1' - 5 1/2"
D
D
bar type pendant
M M M in knee space
A A A
A
A
A G G A A A A
G G G G
t
B
B
B
B
B
B B
C
C
D
A
D
D F
A
A
A A
C
C
A
A A
A A
A
A wp A wp
J
J
J
D
A.Sub-Flr
dropped ceiling
9' - 1" M
M M
M
A.Sub-Flr
dropped ceiling
9' - 8"
A.Sub-Flr
dropped ceiling
9' - 1"
A.Sub-Flr
dropped ceiling
9' - 1"
C
E
E E E E
E E
A
J
D
D D D D
D
steel beam
M. CLOSET
W208
MASTER
BEDROOM
W205
LANDING
W204
LIVING
W200
KITCHEN
W202
DINING
W201
POWDER
W203
MASTER BATH
W206
WC
W207
A.Sub-Flr
dropped ceiling
9' - 1"
A.Sub-Flr
dropped ceiling
9' - 1"
A
A
A.Sub-Flr
dropped ceiling
9' - 1"
A.Sub-Flr
dropped ceiling
9' - 1"
CEILING AT 11'-9 1/4"
CEILING AT 11'-9 1/4"
A
A A
A A A A A
A A A
D
steel beam
D
fireplace 8057'-6 1/4" top plate
8062'-9 1/2" top plate
CEILING AT 9'-6 1/4"
E
A
E
E
L
L
L
L
L
C
C
A
A
A
A
A A A L L L L L L
L
L
review in-floor outlet location for living room
review in-floor outlet location for living room
G G
fireplace
fireplace
CEILING AT
BTM OF
STRUCTURE
ABOVE
11'-9 1/4"
A
A
A G G
G G
TO LIGHTS ON
LANDING AND
SWITCH
BELOW
TO LIGHTS ON
LANDING AND
SWITCH
ABOVE
t
E
TO LIGHTS ON
LANDING AND
SWITCH
BELOW
TO LIGHTS ON
LANDING AND
SWITCH
ABOVE
E A
A
TO STEP
LIGHTS AND
EXTERIOR
GARAGE WALL
LIGHTS BELOW
TO SWITCH ABOVE
J
G G G
G G G REVIEW LIGHTS
ON TOP OF
CABINETS TOO
SD
CM
SD
SD
CM
3:12
D
D
1
A5.1
SD
gfci
gfci
gfci
EXTERIOR OUTLET
gfci
OUTDOOR RECEPTACLES
ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND
BE GFCI
gfci
EXTERIOR OUTLET
OUTDOOR RECEPTACLES
ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND
BE GFCI
gfci
EXTERIOR OUTLET
gfci
EXTERIOR OUTLET
gfci
EXTERIOR OUTLET gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci
gfci gfci
gfci gfci gfci
gfci
gfci
A wp
D
E
F
G
J
K
L
5" RECESSED CAN LIGHT (wet location)
5" RECESSED CAN LIGHT (sloped ceiling fixture)
5" RECESSED CAN LIGHT (directional spot)
CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT)
A
5" RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
H
FLUORESCENT CLOSET LIGHT
BATH FAN
2x4 FLUORESCENT FIXTURE
SURFACE MOUNT
STEP LIGHT
M
COVE LIGHTING (LED TAPE)
1/2 HOT DUPLEX OUTLET
NOTES:
1 PROVIDE DOOR BELL CHIME AT EACH LEVEL.
2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE
LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR
3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE
DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL
4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS
B
C
t
THERMOSTAT
SD
CM
SMOKE DETECTOR
CO SENSOR/DETECTOR
SWITCH
INTERIOR LIGHTING NOTE
GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
ARC-FAULT CIRCUIT INTERRUPTER
AFCI protection is required on all branch circuits supplying
outlets or devices installed in dwelling unit kitchens, family
rooms, dining rooms, living rooms, parlors, libraries, dens,
bedrooms, sunrooms, recreation rooms, closets, hallways,
laundry areas, and similar rooms and areas.
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15
AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A
COVER AND WEATHERPROOF WHILE IN USE OT NOT
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
7/13/2017
4:01:13 PM
A6.1 MAIN
LEVEL
RCP
1670
2655
Davos
Trail PERMIT
SET
04-28-17
Custom
Duplex at Vail Colorado
1/4" = 1'-0"
1
A2.0 MAIN LEVEL RCP AND ARCH
LIGHTING PLAN
1/4" = 1'-0"
ELECTRICAL LEGEND
No. Description Date
1 Revision 1- BUILDING
DEPT COMMENTS
7-13-17
08/29/17