HomeMy WebLinkAboutB17-0161_A6.2_1504018439.pdf2
A4.1
1
A4.2
3
A4.1 1
A4.1
2
A4.3
2
A4.2
3
A4.2
1
A4.3
4
A4.1
2
A4.4
1
A4.4
PARTY
WALL
5
A5.1
1
A5.2
F
SD
CM
B
B
B
B
B
B
D
J
t
B B
TO BELOW
B B B B
J
J
F
F
F
B B
B B
D
B B
B B
B B
B B
A wp
E
A
E E E E
A wp A wp
A
t
F
B B
A.Sub-Flr
dropped ceiling
9' - 9" A.Sub-Flr
dropped ceiling
9' - 9"
3:12
3:12
2:12
2:12
3:12
2:12
3:12
3:12
3:12
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
8070' - 6" top plate
8066' - 1" top plate 8066' - 1" top plate
8066' - 1" top plate
8065' - 1" top plate 8072' - 3 3/4" top plate
8069' - 10" top plate
8067' - 10" top plate
8063' - 1" top plate
2:12
2:12
8070' - 6" top plate 8070' - 6" top plate
D
TO SCONCE
AND SWITCH
BELOW
A.Sub-Flr
dropped ceiling
9' - 9"
F
B
B
B
B
B
D
A C
C
FIREPLACE
D
D J
J
J
E E
A wp
F
B
B
B B
D
E E
A wp
B
B
HOT TUB DISCONNECT
OFFSET RADON VENT
PIPE/STACK
A.Sub-Flr
dropped ceiling
10' - 1"
A.Sub-Flr
dropped ceiling
10' - 1"
A wp
A wp
A wp
A wp
E E TO STEP LIGHTS
TO 5 LANDSCAPE LIGHT
(<18" TALL)
A
A E
J
2:12
A.Sub-Flr
dropped ceiling
9' - 9"
BEDROOM
W310
BEDROOM
W306
BEDROOM
W303
FAMILY
W300
MASTER
BEDROOM
E307
BEDROOM
E309
LANDING
E300
BEDROOM
E303
ASSESS CEILING HT IN
THIS AREA OVER
DOOR TO LEAVE MAX
HEIGHT, BUT ENOUGH
ROOM TO GET FLUE
ACROSS
RUN FLUE FROM MASTER FP TO
CHIMNEY MASS ON ROOF
1
A5.1
B B
UNDERFRAME CEILING TO
MATCH ROOF OF
SOUTHERN PORTION
3:12
CM SD
SD
SD
SD
SD
SD
SD CM
gfci gfci
gfci
E
gfci
gfci
gfci
gfci
FIREPLACE
APPLIANCE IS TO
APPROVED TO BE
IN SLEEPING
ROOMS
EXTERIOR OUTLET
EXTERIOR OUTLET
SD
smoke alarm at high
point in ceiling
EXTERIOR OUTLET
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND BE GFCI
gfci
gfci
gfci
gfci OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND BE GFCI
OUTDOOR RECEPTACLES
ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND
BE GFCI
A wp
D
E
F
G
J
K
L
5" RECESSED CAN LIGHT (wet location)
5" RECESSED CAN LIGHT (sloped ceiling fixture)
5" RECESSED CAN LIGHT (directional spot)
CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT)
A
5" RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
H
FLUORESCENT CLOSET LIGHT
BATH FAN
2x4 FLUORESCENT FIXTURE
SURFACE MOUNT
STEP LIGHT
M
COVE LIGHTING (LED TAPE)
1/2 HOT DUPLEX OUTLET
NOTES:
1 PROVIDE DOOR BELL CHIME AT EACH LEVEL.
2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE
LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR
3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE
DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL
4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS
B
C
t
THERMOSTAT
SD
CM
SMOKE DETECTOR
CO SENSOR/DETECTOR
SWITCH
INTERIOR LIGHTING NOTE
GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
ARC-FAULT CIRCUIT INTERRUPTER
AFCI protection is required on all branch circuits supplying
outlets or devices installed in dwelling unit kitchens, family
rooms, dining rooms, living rooms, parlors, libraries, dens,
bedrooms, sunrooms, recreation rooms, closets, hallways,
laundry areas, and similar rooms and areas.
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15
AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A
COVER AND WEATHERPROOF WHILE IN USE OT NOT
970.328.5151
OFFICE
PO Box 1587,
Eagle, CO 81631
www.martinmanleyarchitects.com
Project
number
Date
REVISIONS
7/13/2017
4:01:14 PM
A6.2 UPPER
LEVEL
RCP
1670 2655
Davos
Trail
PERMIT
SET
04-28-17
Custom
Duplex at Vail Colorado
1/4" = 1'-0"
1
A3.0 UPPER LEVEL RCP AND ARCH
LIGHTING PLAN
1/4" = 1'-0"
ELECTRICAL LEGEND
No. Description Date
1 Revision 1- BUILDING
DEPT COMMENTS
7-13-17
All exterior outlets to be WR
and to have Extra Duty rated
in-use covers.
08/29/17