Loading...
HomeMy WebLinkAboutB17-0161_REV1 - approved documents_1514911406.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B17-0161 / Revision 001 Issued: 01/02/2018 TOWN OF VAIL Property Information Address: 2655 DAVOS TRL ( 210314203027 ) Unit #: Parcel Number: 210314203027 Legal Description: Subdivision: VAIL RIDGE Block: B Lot: 18 Contacts Contact Type: Applicant Full Name: Mike Young Address: PO Box 480 1800 Beard Creek Trail Edwards, CO 81632 Phone: 9703762020 Contact Type: Property Owner Full Name: SENTRY CONSTRUCTION INC Address: Phone: None Contractor Contractor Type: General Company: Sentry Construction Inc State License #: Phone: 970-376-2020 Project Information Project Name: Sentry Construction Residence 2016 Project Description: REV1 - Infloor heat throughout with use of high efficiency boiler Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$4,749.00 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$3,086.85 Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$16,172.00 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$600.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$150.00 Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$1,200.00 Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$300.00 Account #: 111-0000.31127.00 - Recreation Fee Fee Amount:$712.50 Account #: 001-0000.31111.00 - Revision Fee Fee Amount:$220.00 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00 Total Paid:$27,205.35 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970.479.2139 www.vailgov.com TRANSMITTAL FORM Use this form when submitting additional information, changes & inspection reports for building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$110 will be charged upon reissuance ofthe permit. Submit this form only to: cdev_submittal@vailgov.com. Deliver paperplans to Community Develop- ment or upload your revised/corrected plans to the appropriate project in Projectoox, when requested. /Application/Permit #(s) information applies to: ---'BL.::..-+- l--1]_-...,,. 0~......f....0"'-"'~----'·~0o<.....=: O__._ / I()Revisions ( ) Responseto Correction Letter _attached copy of correction letterI()Deferred Submittal ()O ther _ _ _ _ _ _ _ _ _ _ _ It ............_,_...... . .._,..-_ ......~-·-...- . .-,.. ~--·~··· ._., iProject Street Address: !~'-5S Dc..vos ±ro..il w£sr I(Number) (Street) (Suite#) j Building/Complex Name: Do..va.S Dvplex I-·-..~~-- .. -~··~·-···-~..·...... ........ _.__........... -· ...... "......-..-... !Applicant Information ' (architect, contractor, owner/owner's rep) ! contactName: l' 1 1 k e Yov/""13 !Address: PO Bc1x. Y ]JO !! Description of Transmittal/ List of Changes, ItemsAttached, ;Indicate changed plan pages: '- - - - - -- - - -- - - - - - - - - - - -!In floor bee.. t +-hro3h cµv+ VJ~·+t.. ~ use s o f H1f1b eEF, Bo, ·ler City E.J.wc...cd ~ State: c.. o Zip: %'IC,3J (use additional sheet ifnecessary) Contact Name: JV\ i I~e. l (o C/f\ fj : - · - - - - - - Building Permits:!Contact Phone: q Z0-3 ZG-; l o ;;;2.0 ·Revised ADDITIONAL Valuations (Labor & Materials) l (DO NOT include original valuation)lContact E-Mail: ,N\ ,·Kg, 1'o vD8 1 . 0 2 . 0 Q m~c .C cvy l · Building: $_ _ _ _ _ _ _ _ _ I hereby acknowledgethat I have read this application,filled out in fullthe information required, completed an accurate plotplan, and state that all the information as required is correct. I agree to comply with the information and plotplan, to comply with all Town ordinances and state laws, and to build this structure according to thetown's zoning and subdivision codes, design review ap- proved, International Building and Residential Codes and other ordinances of the Town applicable t o. Plumbing: Electrical: Mechanical: Total: $~-------- $~-------- $_ _ _ _ _ _ _ _ _ $_ _ _ _ _ _ _ _ _ iX~~~~~~~~~~~~~ 1 Owner/0 I I ,--·------- --·- .... ··---·- ..... ... -.......... .. ---- - ... ·---··- - .. - - - - - - - - - - - - - - I Date Received: . It-ri' IA r I . ,J_ fLu,,.Jo~ ',,.,"' ~ H /'/--r.' I++-)¥..L'...~tl.(4. ..--1LX.lLm.l.J ~~ ----' RECEIVED OCT262017 TownofVail 21-Apr-2017 ·O T r ia n g le Stainless Steel Fire Tube · Heat Exchanger 95%AFU E · Low Pressure Drop · _ Proven Perform a nc e · 2" to 4 " Venting · "---" Multiple Termination Options · Low NOx - 2 0 1 2 SCAQMD Certified · 5 Models from 6 0 to 3 99 MBH · 2 Year Control & Blower W a rran ty · featuring TriMax control with: ,,. ! I · 6 0 Secon d Set-Up · Integ ra ted Casca de · Two Res e t C u rves /S et Points · Control of 4 Circulators ( I <i>•0 ~cGus Smle ------......' -~ t; ...... JI(_. \ prestige - Leader in Contractor Friendl~ Features tt TriMax Control 60 Second Set-Up Choosefrom 6 standard applicationstoset upthe boiler in 60 seconds or less. · Finned Tube Baseboard · High Mass Radiant · Cast Iron Baseboard · Low Mass Radiant · Radiators · Fancoil Integrated Cascade Joins up to 6 boilers: Master boiler automatically recognizes linked boilers: Meets simultaneous DHW & Space Heating calls: Full Parallel Modulation. Multiple Zone & Circulator Control Manages 2 separate reset curves for high and lowtemperature zones: Controls up to 4 circulators. Manages 2 space heating zones and 1 DHW zone without external zone control panel. Intelligent Troubleshooting Describes lockouts in plain english and suggests solutions: Stores last 8 errors. Records sensor readings for 24 hours. Next Generation Fire Tube Heat Exchanger High Water Content · Provides stable temperature control · Lowsensitivity to water flow · Reduces shortcycling · Adaptsto large or small heating loads Unique Geometry · Designed for maximum reliability with lowthermal stress · Improved water flow for maximum heattransfer · 439 Stainless Steel for corrosion resistance · Polypropylene condensate pan and flue resists corrosion Reliable Low Maintenance Design · Self cleaning design washes away combustion debris · 1O year history of reliable performance · High performance burnerdesign · Lowpressure drop allows piping directly to the system ,. / eprestige - Leader in Contractor Friendl~ Features Prestige Solo 110 Exploded View PolypropyleneFlueand CondensatePan Eliminates corrosion from condensate ~-- IntegratedCirculator& DHW Supply on Solo110 Model Simplifies piping and wiring Fold Down Control Panel Permits quick access to boiler internals Simplified Wiring Connections Wiring connections are well laid out . and clearly marked . Fused high voltage connections makestrouble shooting easy T he W idest Range of Ven ting an d T ermina tion O ptions Venting Terminations - 2", 3", and 4" diameters depending on model - Traditional PVC/CPVC/PP/SS piping elbows - PVC,CPVC, SS and Polypropylene materials - Flush-mount PVC for twin pipes - Flexible Polypropylenefor chimney chases - Flush-mount Stainless Steelfor twin pipes - Concentric (399only) ortwin pipe - SingleholeConcentricTermination for twin pipes - Extended vent lengths up to 100 feet - Horizontal Concentric Termination.(399 only) -Common Ventfor multiple boilers (399only) - Horizontaland Vertical Common VentTerminations(399only) I prestige · Performance Specifications ::.- Model° . Fi.lei Input AFUE DOE NET Water f;: , · Modulation Heating Capacity l=B=R Volume ~;,,, MBH MBH MBH Gal Solo60 Natural or Propane 16to 60 95% 54 47 2.5 Solo110 Natural Gas 30to110 95% 99 86 2.5 Solo110LP PropaneGas 25to97 95% 87 76 2.5 Solo175 Natural or Propane SO to170 95% 154 134 4.6 Solo2SO Naturalor Propane 65to245 95% 223 194 4.1 Solo399 NaturalorPropane 112to399 95.1 %* 379 330 7 Connections / Dimensions / Data 'Thermal Efficiency ·· Model Supply I Return Gas Vent/Air Dimensions Weight Connections Connection Diameter 0 x W x H Lbs · - - · - · < Solo60 1· 112" 3" 16"x 20" x 35 112" 95 Solo110 1· 112" 3" 16"x 20" x 35 112" 106 Solo175 11/4" 314· 3" 16"x 20" x 35 112" 131 Solo2SO 11/4" 314· 3" 16"x 20" x 35 112" 142 Solo399 1 112" 1· 4· 20 3/4"x 24 314· x 37112" 200 TriMax Control Features Standard Features ·"""""""" "" large Graphic Interface " Stainless Steel FireTube HeatExchanger 60 Second Set-Up · "EZAccessTerminal Stripswith Individually Customizable Reset Curves with 6 Presets Fused High VoltageTerminals StandardModbus Interface "Outdoor Reset Sensor 2 SpaceHeating Call Inputs "Negative Pressure Regulated Gas Valve Controls up to 4 Circulators " LP Conversion Kit 0-10 VDC Modulation Input (All Models except Solo110) Outdoor Reset "Cat IV Venting Lockout Screens with Error Description and NPTPiping Connections Troubleshooting recommendations:"Integrated Pressure Gauge Cascade Controlfor up to 6 Boilers "30 psi Pressure Relief Valve- Auto-configure linked boilers - Simultaneousspace heating & DHWcapability "AutomaticAir Vent- Full parallel modulation - Boiler rotation "Fold-down Control Panelfor Easy Access DHW Priority "CondensateTrap Warm Weather Shutdown "10 Year Non-Prorated HeatExchanger LowWater Cut Off Warranty "2 YearControl & BlowerWarranty 0 Tr1angleTu 1 Triangle Lane Blackwood, NJ 08012e Tel: (856) 228 8881- Fax: (856) 228 3584 E-mail: info@triangletube.com - http://www.triangletube.com 2011-48 Prestige Solo UL- Revised 1/17113 lirect Water Heaters -- Model ~ 30 40 40L 50 60 60L 80 . 115 80--HO 115-HO 80-HO-C 115-HO-C Storage Volume (Gals.) 30 40 42 50 60 60 80 115 80 115 80 115 HOTOllTlET T+PYAl.YE DOM. CDWINLET Model 30 40 40L 50 6060L 80 115 80- HO 115- HO 80-HO-C 115-HO-C Co il Piping C onnections-N.P.T. Max. Heating Dimensio n s Domestic Boiler Working Surface (inches) Water Water Pressure So. Ft. Ht. Dia. In/Out In/Out (DSO 7.0 34.0 23.5 3/4 1 150 7.5 44.0 23.5 3/4 1 150 7.1 36.0 28.0 3/4 1 150 8.0 54.0 23.5 3/4 1 150 8.3 62.0 23.5 3/4 1 150 7.5 46.0 28.0 3/4 1 150 8.0 56.0 28.0 1 1 150 8.9 74.0 28.0 1 1 150 HiqhOuto Jt Units 80-HO and 115-HO 13.4 56.0 14.4 74.0 13.4 56.0 14.4 74.0 &.O "c::i .. 0- Max. First Hour Rating GalJHr.@ 140F 115F 195 259 215 284 195 259 234 308 254 333 233 302 266 341 319 403 Hiah 386 507 439 568 408 537 450 583 28.0 1 28.0 1 28.0 1 1/2 28.0 1 1/2 ll4"NPT RfCIRC. PORT llOILERRETURN 11/X'HPT HOTOOJlET BOILERSUPPt.Y 11/4.NPT BOILERSlAl'flt.Y 11/T NPT DOM. CDWINLET ... 0- 0 1 1 11/4 1 1/4 150 150 150 150 T+PYALYE 11/4"NPTBOURRETURN _,__ . -CUNTS Continuous Boiler Min . Boiler Pressure Rating Output Water Flow Drop GalJHr. @ RAnUired Throunh Coil Throuoh Coil 140F 115F (BTU/Hr.I GalJMin . (Ft.Water) 168 232 125,600 14.0 5.3 179 248 134,200 14.0 5.7 168 232 125,600 14.0 5.3 189 263 129,900 14.0 6.0 200 279 151,000 14.0 6.2 179 248 134,100 14.0 5.7 194 269 145,600 14.0 6.0 216 300 162,400 14.0 6.6 >utnut Units 80-HO and 115-HO 314 435 235,600 14.0 9.9 336 465 251,700 14.0 10.5 336 465 251,700 21.0 15.8 347 480 259,800 21.0 16.7 Note: All Ratings are based on 200 degree Fboiler water supplyand 50 degreeFcold Water inlet. For180 degree Fboiler watersupplymultiply by ratings by 0.86 In theinterest of continuous improvement, specifications are subject to changewithout notice. www.heat-flo.com Approx Shipping Wt.-Lbs. 85 100 100 110 125 120 140 175 155 190 155 190 ® 2015 Dylan McCormick Ferguson Enteprise 550 Raritan Way Suite A Highland Plumbing & Headlg, Ill. P.O. Box 3697 Heating System Summary Denver, CO 80204 Eagle. CO 81631-3697 Project #:West A Project Information Project#: Name: Location: West A West A Davos Duplex Vail, CO 8,200' Project Summary Load Calculation Method: Design Location: OutdoorTemperature: FloorplansI Levels: Basement Main Floor Second Floor Total Area: Zone Heating Summary Phone: 303-942-8102 Fax: 303-825-3562 Email:dylan.mccormick@ferguson.com Manual J8 (User Specified) Vail, Colorado -20.0 °F 1,595 ft2 1,615 ft2 1,196 ft· 4,405 ft2 Total Tubing Lengths: Barrier PEX 1/2" Total RH Circuits: Total Manifolds: Total Zones: Fluid Type: Total Tubing Volume: Notes: 5,500 ft 26 10 10 100% Water 50.63 USG Component Losses: lnfiltrationNentilation: Radiant Back Losses: Total Heating Load: Radiant Heating: Radiant Back Losses: Total Heating Load: Zone# Area Construction Heating Types RH Total Manifolds Flow rate Head Loss RH Load Circuits Tubing 101 740 Embedded Slab RH 4 717 1 1.00 1.7 9,936 102 370 Embedded Slab RH 1 256 1 0.38 3 .0 3,282 103 486 Embedded Slab RH 3 533 1 0.56 1.8 4,764 201 213 Gypsum Thin Slab RH 2 378 1 0.36 1.4 3,374 202 209 Gypsum Thin Slab RH 1 206 1 0.22 1.6 1,656 203 1,193 Gypsum Thin Slab RH 8 1,841 1 2.44 2.6 24,323 301 400 Gypsum Thin Slab RH 3 614 1 0.73 1.7 6,980 302 243 Gypsum Thin Slab RH 1 227 1 0.35 2.4 2,837 303 280 Gypsum Thin Slab RH 1 257 1 0.35 2.7 3 ,241 304 273 Gypsum Thin Slab RH 2 469 1 0.53 1.9 5,468 Total 4,405 multiple RH 26 5,500 10 6.93 3.0 65,863 Length= ft Area = 12 Temperature = "F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft2 Rv = hr·ft2· "F/btu Head Loss= ft water RH = Radiant Floor Heating BB= Baseboard FA= Forced Air OTH = Other Heating SM= Snowmelt N = Not Heated See end of report for important Notes and Disclaimers . October 19, 2017 41,414 Btu/hr 20,953 Btu/hr 3,496 Btu/hr 65,863 Btu/hr 62,367 Btu/hr 3,496 Btu/hr 65,863 Btu/hr Supplemental Total Load 0 9 ,936 0 3 ,282 0 4,764 0 3 ,374 0 1,656 0 24,323 0 6 ,980 0 2,837 0 3 ,241 0 5,468 0 65,863 Created Using LoopCAD 2015 (10/19/2017) Version:15.0.0380 Page 1 of 4 t-!ame:West A Davos Duplex Project #:West A Room Heating Summary (By Construction Type) Embedded Slab Zone# Room Name Heating Area Heated Manifold Type Area # 101 Garage RH 740 696 Manifold 1 102 Entry W106 RH 229 155 Manifold 2 102 Mud RH 141 118 Manifold 2 W102/Laundry RoomW103 103 Bathroom W109 RH 137 111 Manifold 3 103 JR. Suite RH 240 227 Manifold 3 Bedroom W107 103 Walk-In Closet RH 68 61 Manifold 3 W110 103 Water Closet RH 40 35 Manifold 3 W108 Tube RH Tube Total Floor Size Circuits Spacing Tubing Cover RV 112" 4 12 685 0.0 1/2" 1 12 243 0.7 1/2" 1 12 243 0.7 1/2" 1 12 201 0.3 1/2" 2 9 303 1.2 1/2" 1 12 201 1.2 1/2" 1 12 201 0.3 Length= ft /Vea = fP Temperature = 'F Flowrate = USGPM Heat Loss = Btu/hr Unij Heat Loss = Btu/hr·ft' Rv = hr·ft" 'F /btu Required Temp. 97 103 94 89 107 98 88 Head Loss = ft water RH= Radiant Floor Heating BB= Baseboard FA= Forced Air OTH = Other Heating SM= Snowmelt N = Not Heated See end of report for important Notes and Disclaimers. Unit RH Load 14.1 10 8.7 6.8 13.6 9 .2 7 .2 RH Load 9,936 2,153 1,129 866 3,083 562 253 Heating System Summary October 19, 2017 Supplemental Total Load 0 9,936 0 2,153 0 1,129 0 866 0 3,083 0 562 0 253 Created Using LoopCAO 2015 (10/19/2017) Version:15.0.0380 Page 2 of 4 ~ame:West A Davos Duplex Project #:West A Gypsum Thin Slab Zone# Room Name 201 Master Bedroom 202 Master Bathroom 202 MasterWalk-In Closet 202 Water Closet 203 living Room W200/Dining W201 /Kitchen W202 203 Powder Room 301 Family Room W300 302 Bathroom W304 302 Bedroom W303 303 Bathroom W305 303 Bedroom W306 304 Bathroom W308 304 Bedroom W31 O RH Manifold Summary Manifold Name Manifold 1 Manifold 2 Manifold 3 Manifold 4 Manifold 5 Manifold 6 Manifold 7 Manifold 8 Manifold 9 Manifold 10 Total Heating Area Heated Type Area RH 213 180 RH 130 102 RH 50 45 RH 28 24 RH 1,138 875 RH 55 40 RH 400 298 RH 55 43 RH 188 175 RH 49 35 RH 232 218 RH 71 54 RH 202 186 #Zones 1 1 1 1 1 1 1 1 1 1 10 Manifold Tube RH Tube Total Floor # Size Circuits Spacing Tubing Cover RV Manifold 4 1/2" 2 6 365 1.2 Manifold 5 1/2" 1 9 199 0.3 Manifold 5 1/2" 1 9 199 1.2 Manifold 5 1/2" 1 9 199 0.3 Manifold 6 1/2" 7 6 1,545 0.7 Manifold 6 1/2" 1 6 233 0.3 Manifold 7 1/2" 3 6 594 0.7 Manifold 8 1/2" 1 12 221 0.3 Manifold 8 1/2" 1 12 221 1.2 Manifold 9 1/2" 1 12 251 0.3 Manifold 9 1/2" 1 12 251 1.2 Manifold 10 1/2" 1 6 219 0.3 Manifold 10 1/2" 1 6 237 1.2 #Circuits Flowrate Head Loss Required Supplied Temp. Temp. 4 1.00 1.7 97 110 1 0.38 3.0 103 110 3 0.56 1.8 107 110 2 0.36 1.4 120 125 1 0.22 1.6 100 110 8 2.44 2.6 123 125 3 0.73 1.7 117 125 1 0.35 2.4 113 125 1 0.35 2.7 110 125 2 0.53 1.9 123 125 26 6.93 3.0 123 - Length = ft Alea = IP Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft2 Rv = hr·ft" °F/btu Required Unit RH RH Load Temp. Load 120 17.8 3,572 98 11.2 1,331 85 2.8 128 100 14.2 343 123 22.3 24,423 109 18.3 876 117 19.4 7,300 99 13.3 651 113 13.4 2,356 106 16.6 702 110 12.5 2,733 114 27.3 1,706 123 21.4 3,996 Temp Drop Manifold Type 20 (29) None Selected 20 (23) None Selected 20 (27) None Selected 20 (22) None Selected 20 (27) None Selected 20 (28) None Selected 20 (23) None Selected 20 (25) None Selected 20 (27) None Selected 20(25) None Selected - - Heating System Summary October 19, 2017 Supplemental Total Load 0 3,374 0 1,240 0 93 0 323 0 23,486 0 837 0 6 ,980 0 613 0 2,225 0 669 0 2,571 0 1,660 0 3,808 Control Type #Actuators Manifold 0 Manifold 0 Manifold 0 Manifold 0 Manifold 0 Manifold 0 Manifold 0 Manifold 0 Manifold 0 Manifold 0 - 0 Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA= Forced Air OTH =Other Heating SM= Snowmelt N = Not Heated Created Using LoopCAD 2015 (10/19/2017) Version:15.0.0380 See end of report for important Notes and Disclaimers. Page 3 of 4 "'!ame:West A Davos Duplex Project #:West A Disclaimers Heating System Summary October 19, 2017 With the permission of the Air Conditioning Contractors of America C'ACCA"), material is reproducedfrom Manual J Residential Load Calculation (8th Edition)which is copyrighted by ACCA. The program and data are provided "as is" without warranty of any kind etther expressed or implied. The entire risk as the qualtty and performance of the program and data is with you. In no event will ACCA be liable to you for any damages, including wtthout limitation any lost profits, lost savings, or other incidentalor consequential damages arising out of the use or inability to use this program or the data. © 2011 Air Condttioning Contractors of America. All Rights Reserved. www.acca.org ACCA, Manual J and Powered by ACCA Manual J are registered trademarks of the Air Condttioning Contractors of America. All rights reserved. Cold weather humidification,or some lifestyles that produceexcessive moisture, may cause condensation to occur ifthe absolute humidityof the indoorair is too high for the momentary circumstances. Condensation can occur on surfaces or concealed wtthin the structure, and can lead to mold, mildew, frost damage, and moisture damage. The software does not perfolTll calculations for the estimation or detectionof possible condensation problems, and tt is the designers Q.e. software users) responsibility to do so independentlyif required. For guidance and additionalcautions referto ACCA Manual J 8th Edition, includingSection 1-11 and Section 27. The calculated values shown in this report are based on the data input by the user ofthe software. Inaccurate or erroneous data input will resuH in inaccurate or erroneous results. You are strongly advised to review all input data carefully, and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suttability for your application. IN NO EVENT WILL AVENIR SOFTWARE INC. ("AVENIR") OR ITS AFFILIATES BE LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OR OTHER LEGAL OR EQUITABLE THEORY FOR ANY CONSEQUENTIAL, INCIDENTAL, INDIRECT OR SPECIAL OR PUNITIVE DAMAGES WHATSOEVER (INCLUDING, BUT NOT LIMITEDTO, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSS OF BUSINESS INFORMATION OR DATAAND THE LIKE), EVEN IF SUCH PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. AVENIR'S CUMULATIVE LIABILITY FROM ANY CAUSE RELATED TO OR ARISING FROM THE USE THIS REPORT, AND REGARDLESS OF THE FORM OF THE ACTION, SHALL BE LIMITED TO NO GREATER THAN THE AMOUNT OF FEES PAID TO AVENIR UNDER THE SOFTWARE LICENSE AGREEMENT. Length = ft Area = ft' Head Loss = ft water Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr RH= Radiant Floor Healing BB= Baseboard FA= Forced Air See end of report for important Notes and Disclaimers. Untt Heat Loss = Btu/hr·ft' OTH = Other Healing Rv = hr·ft" °F/btu SM = Snowmelt N = Not Heated Created Using LoopCAD 2015 (10/19/2017) Version:15.0.0380 Page 4 of 4