HomeMy WebLinkAboutB17-0161_REV1 - approved plans_1514912527.pdfZone District: Primary / Secondary Residential
Lot Area: .362 acres x 43,560 s.f. = 15,769 s.f.
• GRFA Allowed: .46% lot area < 10,000 s.f. = 4,600 s.f.
.38% lot area < 15,000 s.f. = 1,900 s.f.
.13% lot area (681 s.f.) = 100 s.f.
Total = 6,600 s.f.
• Primary/Secondary Split: 60% = 3,960 s.f. 40% = 2,640 s.f.
WEST 'A' Unit (PRIMARY) unit
Lower Level
Foundation wall reduction calculation (See sheet A0.2) 64.48% Buried
Lower Level Area= 1723.0
Area= 1723.0 s.f. X 64.48% reduction= 1111.0 s.f.
Garage Allowance reduction -600.0 s.f.
GRFA area of Lower Level 12.0 s.f.
Main Level
Area= 1704 s.f.
Upper Level
Area = 1227.9 s.f.
+16'-0" Ceiling ht 0 s.f.
WEST UNIT'A' GRFA total area = 2,943.9 s.f. (<3,960 s.f. allowed)
TOTAL AREA OF WEST UNIT, INCLUDING THE GARAGE, WITH NO REDUCTIONS =4654.9 s.f.
EAST 'B' Unit(SECONDARY) unit
Lower Level
Foundation wall reduction calculation (See sheet A0.2) 64.48% Buried
Lower Level Area= 1017.2
Area= 1017.2 s.f. X 64.48% reduction = 655.9 s.f.
Garage Allowance reduction -600 s.f.
GRFA area of Lower Level -238.7 s.f.
Main Level
Area = 1189.2 s.f.
Upper Level
Area = 1204.1 s.f.
EAST UNIT 'B' GRFA area = 2,154.6 s.f.(<2,640 s.f. allowed)
TOTAL AREA OF EAST 'B' UNIT, INCLUDING THE GARAGE, WITH NO REDUCTIONS = 3410.4 s.f.
ALLOWED Site Coverage (20% of lot) 3,154 s.f. (includes roof overhangs over 4’ deep)
PROPOSED Site Coverage = 3,148.9 s.f. (<3,154 s.f. allowed)
TOTAL Disturbed Area Allowed= <60% = 9461.4 s.f. Proposed 10,571.5 s.f. 67 %
(undisturbed = 5197.5 s.f. 33%) (7 % greater than allowed.)
REQUIRED Landscape Area (60% of lot) = 15,769 s.f. X .60= 9461.4 s.f.
Lot Area= 15,769 s.f.
Proposed Site Coverage = 3,148.9 s.f.
Impervious terrace area = 1400.0 s.f.
Impervious drive area= -1,111 s.f.
PROPOSED Landscape Area= 10,109.1 s.f. 64.1% (>9,461.4 s.f.)
Drive area:
West unit: 608 s.f. of drive
East unit: 503 s.f. of drive
Snow storage = (required =30% of Drive area):
West unit snow storage= 182.4 s.f. required, 200 s.f. provided
East unit snow storage= 150.9 s.f. required, 175 s.f. provided
Parking per unit = 3 spaces, (2 interior and 1 exterior)
Average Lot slope under footprint of units greater than 30%:
Unit 'WEST' = 100%
Unit 'EAST' = 95%
Density = Duplex residence
Lighting: Dark sky/full cut off, limit on light above 18" a.f.f. is 1/1000 s.f. of lot. 15,769 s.f./1000= 15 lights
Maximum Height = 33'. (30' at flat roof) Height proposed 32'-6" (Living Rm roof of West 'A' unit)
Parking Requirements: 2.5 spaces per dwelling unit = 3 spaces (2 inside, 1 outside)
Retaining walls over 4 feet height to be engineered.
Boulder retaining wall layback for 4'-0" tall wall = 1'-0"
Boulder retaining wall layback for 6'-0" tall wall = 2'-0"
Boulder retaining walls in front setback limited to 3'-0" tall 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:19 PMA0.0COVER16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1 3D View 1
2 3D View 2
3 3D View 3
4 3D View 4 5 3D View 5
Davos Duplex
Residence
2655 Davos Trail
Lot 18, Block B,
Vail Ridge Subdivision
PERMIT SET 04-28-2017
REVN #1 07-05-17
Primary/Secondary Residence
Owner: Mr. Mike Young
Sentry Construction Inc.
PO Box 480
Edwards, CO 81632
970-376-2020 cell
Location: 2655 Davos Trail
Lot 18, Block B,
Vail Ridge Subdivision
Parcel Number2103-142-03-027
Architect: Martin Manley Architect
Jeffrey P Manley AIA
PO Box 1587
Eagle, CO 81631
970.328.5151
jeff@martinmanleyarchitects.com
PROJECT / CODE SUMMARY
Class of Work: New Construction
Type of Construction: Type V-B
Type of Occupancy: R3 (duplex)
Levels: 2-story +basement
Fire Sprinklers: Yes
Monitored alarm system: Yes
Heating: In-floor radiant heat
Furnace/boiler: Min. 92% efficiency
2015 International Residential Code (IRC) including Appendix F & G
General Contractor: Mr. Mike Young
Sentry Construction Inc.
PO Box 480
Edwards, CO 81632
970-376-2020 cell
1" = 10'-0"6 Vicinity Map
1/4" = 1'-0"
ZONING INFORMATION
Sheet List
Sheet
Number Sheet Name
A0.0 COVER
A0.1 AREA PLANS
A0.2 BASEMENT REDUCTION
A0.3 ECO SHEET
A1.1 SITE PLAN
A1.2 LANDSCAPE PLAN
A1.3 CONSTRUCTION MGMT
A2.0 LOWER LEVEL PLAN
A2.1 MAIN LEVEL PLAN
A2.2 UPPER LEVEL PLAN
A2.3 ROOF PLAN & HT CALC
A3.0 SOUTH ELEVATION
A3.1 EAST AND WEST ELEVATIONS
A3.2 NORTH ELEVATION
A4.1 BUILDING SECTIONS
A4.2 BUILDING SECTIONS
A4.3 BUILDING SECTIONS
A4.4 BUILDING SECTIONS
A6.0 LOWER LEVEL RCP
A6.1 MAIN LEVEL RCP
A6.2 UPPER LEVEL RCP No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-1701/02/18
UP
U
DND WDN
DN UP
UP
DN
UP
DN
UP
DNDN
2
4
"
C
O
TTONWOODEDGEOFASPHALTDAVO S TRAI L
LOT
18
ED
GE
OF CONCRETE
BLOCK B
ASPEN
G
R
OVE4" PI
NE6
" PI
NE
8
" PI
NE
8
" PI
N
ETV PE
D
I
NE
F
O
U
N
D
11 _2"BLA
NKALUM
I
NUMC
AP FOU
ND
REBAR
EDGE OFFOUND #5REBARWITHWASHERNorth
42'
44'
46'
48'
50'
52'
54'
56'
58'
60'
66'
68'
70'
34'
32'
40'32'
34'
36'
38'
42'
44'
46'
48'
50'
40'
52'
54'
56'
58'
60'
68'
70'
28'
30'
56'
56'
55'
O
U
L
D
ER WAL
L
CU
L
VERT I
NL
E
T 15' SIDESETBACK15'SIDESETBACK15' BACK SETBAC K
20'
FRONT
SETBACK
7'
UTILITY
EASEMENT
RECEPTION
NO.
103252
P QTV8030
8040
805 0
806 0
8070
UP
DN
DN
DN
DN
DN
DN
UP
DN
UP
DN
1723 SF
'A' Garage and Lower
Level Area
1017.2
SF
'B' Garage and Lower
Level Area 10' - 3 1/2"PARTY
WALL
WALL
1704 SF
'A' Main Level Area
1189.2
SF
'B' Main Level Area
PARTY
WALL
1227.9
SF
'A' Upper Level Area
1204.1
SF
'B' Upper Level Area
PARTY
WALL
3122.9
SF
Lot Coverage
(total max. 3154 s.f.)
26' - 0"
1
A4.2
overhang of garage roof3' - 11"TERRACES AND WALKS
1400 S.F.
2
A4.2
26 SF
Area of overhang over
4'-0"4' - 6 3/4"LINE OF GARAGE BELOW
LINE OF MASTER ABOVE 1' - 0"4' - 0"4' - 9 5/8"PARTY
WALL 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:22 PMA0.1AREA PLANS16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/8" = 1'-0"1 A1.0 LOWER LEVEL
1/8" = 1'-0"2 A2.0 MAIN LEVEL
1/8" = 1'-0"3 A3.0 UPPER LEVEL
1/8" = 1'-0"4 SITE COVERAGE
Area Schedule (west unit 'A')
Name Area
'A' Garage and Lower Level Area 1723 SF
'A' Main Level Area 1704 SF
'A' Upper Level Area 1227.9 SF
Grand total: 3 4654.9 SF
Total of lower levels within 6'-0" of lowest slab ht
MUTIPLY x% OF BURIED FOUNDATION WALL
SUBTRACT 600 S.F. FOR GARAGE
Zone District: Primary / Secondary Residential
Lot Area: .362 acres x 43,560 s.f. = 15,769 s.f.
• GRFA Allowed: .46% lot area < 10,000 s.f. = 4,600 s.f.
.38% lot area < 15,000 s.f. = 1,900 s.f.
.13% lot area (769 s.f.) = 100 s.f.
Total = 6,600 s.f.
• Primary/Secondary Split: 60% = 3,960 s.f. 40% = 2,640 s.f.
• Site Coverage (20%) = 3,154 s.f. (includes roof overhangs over 4’ deep)
• Height Limitation= 33 feet (as measured from existing grade directly to ridge above)
SEE SHEET A0.2 FOR GRFA CALCULATIONS
Area Schedule (east unit 'B')
Name Area
'B' Garage and Lower Level Area 1017.2 SF
'B' Main Level Area 1189.2 SF
'B' Upper Level Area 1204.1 SF
Grand total: 3 3410.4 SF No. Description DateContractor must
submit for a PW
Permit for new site
access to a vacant
lot. Prior to to the
start of project.
01/02/18
A2.0 MAIN LEVEL
8047' - 0"
A1.0 LOWER
LEVEL
8032' - 0"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"11' - 0"15' - 0"6' - 0 1/2"11' - 0"895.35 s.f. of lower level/foundation wall
55.76 s.f. of lower level/foundation wall below grade
PARTY
WALL
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B1.7 MAIN LEVEL
8042' - 0"
EXI STI NG G RA DE 9' - 5"8054' - 0"
8041' - 11"
METAL CORNER TRIM
8037' - 0 1/4"
8032' - 10 1/16"
415.29 s.f. of lower level/foundation wall
288.54 s.f. of lower level/foundation wall below grade
A2.0 MAIN LEVEL
8047' - 0"
A2.0 MAIN LEVEL
8047' - 0"
A1.0 LOWER
LEVEL
8032' - 0"
A1.0 LOWER
LEVEL
8032' - 0"
8047' - 3"8047' - 2"
8049' - 7"
8048' - 0"
EXISTING GRADE
EXISTING AND PROPOSED GRADE
8043' - 0"
8047' - 0"
8038' - 0"
8042' - 0"
8036' - 0"
567.77 s.f. of lower level/foundation wall
558.17 s.f. of lower level/foundation wall below grade
8056' - 0"
8054' - 0"
8050' - 0"
A2.0 MAIN LEVEL
8047' - 0"
A1.0 LOWER
LEVEL
8032' - 0"B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"23' - 9"899.15 s.f. of lower level/foundation wall
899.15 s.f. of lower level/foundation wall below grade
FOUNDATION WALL
BURIED FOUNDATION WALL
KEY:
PARTY
WALL
AREA OF FOUNDATION WALLS
ELEVATION TOTAL FOUNDATION WALL AREA FOUNDATION WALL BURIED
SOUTH 895.35 S.F. 055.76 S.F.
EAST 415.29 S.F. 288.54 S.F.
WEST 567.77 S.F. 558.17 S.F.
NORTH 899.15 S.F. 899.15 S.F.
TOTAL AREA 2,777.56 S.F. 1,801.62 S.F. = 64.48% BURIED
Zone District: Primary / Secondary Residential
Lot Area: .362 acres x 43,560 s.f. = 15,769 s.f.
• GRFA Allowed: .46% lot area < 10,000 s.f. = 4,600 s.f.
.38% lot area < 15,000 s.f. = 1,900 s.f.
.13% lot area (681 s.f.) = 100 s.f.
Total = 6,600 s.f.
• Primary/Secondary Split: 60% = 3,960 s.f. 40% = 2,640 s.f.
WEST 'A' Unit (PRIMARY) unit
Lower Level
Foundation wall reduction calculation (See sheet A0.2) 64.48% Buried
Lower Level Area= 1723.0
Area= 1723.0 s.f. X 64.48% reduction= 1111.0 s.f.
Garage Allowance reduction -600.0 s.f.
GRFA area of Lower Level 12.0 s.f.
Main Level
Area= 1704 s.f.
Upper Level
Area = 1227.9 s.f.
+16'-0" Ceiling ht 0 s.f.
WEST UNIT'A' GRFA total area = 2,943.9 s.f. (<3,960 s.f. allowed)
TOTAL AREA OF WEST UNIT, INCLUDING THE GARAGE, WITH NO REDUCTIONS =4654.9 s.f.
EAST 'B' Unit(SECONDARY) unit
Lower Level
Foundation wall reduction calculation (See sheet A0.2) 64.48% Buried
Lower Level Area= 1017.2
Area= 1017.2 s.f. X 64.48% reduction = 655.9 s.f.
Garage Allowance reduction -600 s.f.
GRFA area of Lower Level -238.7 s.f.
Main Level
Area = 1189.2 s.f.
Upper Level
Area = 1204.1 s.f.
EAST UNIT 'B' GRFA area = 2,154.6 s.f.(<2,640 s.f. allowed)
TOTAL AREA OF EAST 'B' UNIT, INCLUDING THE GARAGE, WITH NO REDUCTIONS = 3410.4 s.f.
ALLOWED Site Coverage (20% of lot) 3,154 s.f. (includes roof overhangs over 4’ deep)
PROPOSED Site Coverage = 3,148.9 s.f. (<3,154 s.f. allowed)
TOTAL Disturbed Area Allowed= <60% = 9461.4 s.f. Proposed 10,571.5 s.f. 67 %
(undisturbed = 5197.5 s.f. 33%) (7 % greater than allowed.)
REQUIRED Landscape Area (60% of lot) = 15,769 s.f. X .60= 9461.4 s.f.
Lot Area= 15,769 s.f.
Proposed Site Coverage = 3,148.9 s.f.
Impervious terrace area = 1400.0 s.f.
Impervious drive area= -1,111 s.f.
PROPOSED Landscape Area= 10,109.1 s.f. 64.1% (>9,461.4 s.f.)
Drive area:
West unit: 608 s.f. of drive
East unit: 503 s.f. of drive
Snow storage = (required =30% of Drive area):
West unit snow storage= 182.4 s.f. required, 200 s.f. provided
East unit snow storage= 150.9 s.f. required, 175 s.f. provided
Parking per unit = 3 spaces, (2 interior and 1 exterior)
Average Lot slope under footprint of units greater than 30%:
Unit 'WEST' = 100%
Unit 'EAST' = 95%
Density = Duplex residence
Lighting: Dark sky/full cut off, limit on light above 18" a.f.f. is 1/1000 s.f. of lot. 15,769 s.f./1000= 15 lights
Maximum Height = 33'. (30' at flat roof) Height proposed 32'-6" (Living Rm roof of West 'A' unit)
Parking Requirements: 2.5 spaces per dwelling unit = 3 spaces (2 inside, 1 outside)
Retaining walls over 4 feet height to be engineered.
Boulder retaining wall layback for 4'-0" tall wall = 1'-0"
Boulder retaining wall layback for 6'-0" tall wall = 2'-0"
Boulder retaining walls in front setback limited to 3'-0" tall 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:28 PMA0.2BASEMENT REDUCTION16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/8" = 1'-0"1 South Elevation FOR GRFA CALC
1/8" = 1'-0"2 East Elevation FOR GRFA CALC
1/8" = 1'-0"3 West Elevation FOR GRFA CALC
1/8" = 1'-0"4 North Elevation FOR GRFA CALC
1/4" = 1'-0"
BASEMENT REDUCTION
1/4" = 1'-0"
ZONING INFORMATION No. Description Date01/02/18
UP
DN UP
Radon System
Radon system is to comply with Appendix F of the 2015 IRC
A sub-slab depressurization system (passive) is to be designed. The vent pipe shall be a minimum dia. of
3" and extend from the permeable layer under the lowest slab with a ' T ' fitting, through the conditioned
space of the homes, and out the roof. The exhaust shall be located as a penetration through the roof and
located on the non-street side. This exhaust vent shall be 2'-0" above the roof surface and 10'-0" away from
any openings or the adjacent building/unit.
An electrical box shall be installed in an accessible location along radon sytem vertical piping so possible
future vent pipe in-line fans can be added.
See sections on this sheet for vertical location of Radon system. See key floor plan on this sheet for
location of piping routing for Radon System.
Additional notes:
N1102.2.1 (R402.2.1) Ceilings with attic spaces.
When Secton N1102.1.1 R-38 shall be deemed to satisfy the requirement for R-49 wherever the full height
of uncompressed R-38 insulation extends over the wall top plate at the eaves.
N1102.2.2 (R402.2.2) Ceilings without attic spaces.
Where Secton N1102.1.1 would require insulation levels above R-30 and the design of the roof/ceiling
assembly does not allow sufficient space for the required insulation, the minimum required insulation for
such roof/ceiling assemblies shall be R-30. This reduction of insulation from the requirements of Secton
N1102.1.1 shall be limited to 500 square feet (46 m2) or 20 percent of the total insulated ceiling area,
whichever is less.
N1102.2.3 (R402.2.3) Eave baffle.
For air permeable insulations in vented attics, a baffle shall be installed adjacent to soffit and eave vents.
Baffles shall maintain an opening equal or greater than the size of the vent. The baffle shall extend over the
top of the attic insulation. The baffle shall be permitted to be any solid material.
N1102.2.4 (R402.2.4) Access hatches and doors.
Access doors from conditioned spaces to unconditioned spaces (e.g., attics and crawl spaces) shall be
weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces. Access
shall be provided to all equipment that prevents damaging or compressing the insulation. A wood framed or
equivalent baffle or retainer is required to be provided when loose fill insulation is installed, the purpose of
which is to prevent the loose fill insulation from spilling into the living space when the attic access is opened,
and to provide a permanent means of maintaining the installed R-value of the loose fill insulation.
N1102.2.5 (R402.2.5) Mass walls.
Mass walls for the purposes of this chapter shall be considered above-grade walls of concrete block,
concrete, insulated concrete form (ICF), masonry cavity, brick (other than brick veneer), earth (adobe,
compressed earth block, rammed earth) and solid timber/logs.
N1102.2.7 (R402.2.7) Floors.
Floor insulation shall be installed to maintain permanent contact with the underside of the subfloor decking.
N1102.2.8 (R402.2.8) Basement walls.
Walls associated with conditioned basements shall be insulated from the top of the basement wall down to
10 feet (3048 mm) below grade or to the basement floor, whichever is less. Walls associated with
unconditioned basements shall meet this requirement unless the floor overhead is insulated in accordance
with Sections N1102.1.1 and N1102.2.7.
N1102.2.9 (R402.2.9) Slab-on-grade floors.
Slab-on-grade floors with a floor surface less than 12 inches (305 mm) below grade shall be insulated in
accordance with Table N1102.1.1. The insulation shall extend downward from the top of the slab on the
outside or inside of the foundation wall. Insulation located below grade shall be extended the distance
provided in Table
N1102.1.1 by any combination of vertical insulation, insulation extending under the slab or insulation
extending out from the building. Insulation extending away from the building shall be protected by pavement
or by a minimum of 10 inches (254 mm) of soil. The top edge of the insulation installed between the exterior
wall and the edge of the interior slab shall be permitted to be cut at a 45-degree (0.79 rad) angle away from
the exterior wall.
N1102.2.10 (R402.2.10) Crawl space walls.
As an alternative to insulating floors over crawl spaces, crawl space walls shall be permitted to be insulated
when the crawl space is not vented to the outside. Crawl space wall insulation shall be permanently
fastened to the wall and extend downward from the floor to the finished grade level and then vertically
and/or horizontally for at least an additional 24 inches (610 mm). Exposed earth in unvented crawl space
foundations shall be covered with a continuous Class I vapor retarder in accordance with this code. All joints
of the vapor retarder shall overlap by 6 inches (153 mm) and be sealed or taped. The edges of the vapor
retarder shall extend at least 6 inches (153 mm) up the stem wall and shall be attached to the stem wall.
N1102.2.11 (R402.2.11) Masonry veneer.
Insulation shall not be required on the horizontal portion of the foundation that supports a masonry veneer.
A section below thru the home shows the locations of all insulation/thermal envelope. On these sections, is shown
the location of vapor barrier/vapor retarder.
Eagle County lies in climate zone 6B.
This is a prescriptive method for insulation and code compliance to energy efficient systems
#1 Insulation values: show the chart that has the climate zone 6B.
Fenestration U-Factor=.32 with a resolution 3.11 C revising the U-factor to .30 in Eagle Co. and .30 in Town of Vail
Skylight U-Factor =.55
Ceiling R-Value = R-49
Wood Framed Wall R-Value 20+5 or 13+10 (20 in the wall cavity and 5 continuous)
Town of Vail, Avon, and Eagle have not adopted the R-5 continuous insulation requirement.
Floor R-Value = R30 (or insulation to fill the framing cavity, R-19 min)
Basement Wall R-Value =15/19 (R15 on the exterior or interior continuous OR R19 in the wall cavity)
The r-19 shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5
continuous on the interior OR exterior of the foundation wall
Slab R-Value =R10 for 4 feet from the edge of the slab measured horizontally or vertically
For heated slabs, R-5 insulation shall be added to the slab edge
Crawlspace wall R-Value = 15/19, which means R15 on the interior or exterior of the home or R-13 cavity insulation
on the interior of the basement wall plus R-5 continuous on the interior OR exterior of the foundation wall
#2 Fenestration and SHGCs (SHGCs are not required in this climate zone of 6)
Fenestration U-Factor=.32 with a resolution 3.11 C revising the U-factor to .30
#3 Area weighted U-factor Calculations
If some windows do not meet the U-factor .30 then an average of window areas can be calculated.
#4 Mechanical system design criteria.
1. Minimum winter design temp of -20 degrees F. (resolution to section R303.9)
2. Heat loss calculations are required for all dwelling units (resolution to section R303.9)
(Heat calcs, zones and layouts are due with the mech. permit application)
3. Minimum efficiency of main heat source is to be 92%
4. A whole house mechanical ventilation system (R303.4) is to be designed where the air infiltration rate
of a dwelling unit is 5 air changes per hour or less where tested with a blower door at a pressure of 0.2
inch w.c (50 Pa) in accordance with Section N1102.4.1.2, the dwelling unit shall be provided with
whole-house mechanical ventilation in accordance with Section M1507.3.
5. N1102.4.1.2 (R402.4.1.2) Testing.
The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 3 air
changes per hour in Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g. (50 Pascals). Where required by the building official, testing shall be conducted by an approved
third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to the building official. Testing shall be performed at any time after creation of all penetrations of the
building thermal envelope.
#5 Mechanical and service water heating system and equipment types, sizes and efficiencies.
Note and locate water heater or side arm off boiler. Label efficiency of water heater and whether gas or
electric is shown on plan set.
#6 Equipment and system controls.
Label location of thermostats and heating zones on key plans.
Provide at least on programmable thermostat
Initially programmed set point of heating no higher than 70 degrees and cooling no lower than 78
degrees
#7 Duct sealing, duct insulation, and pipe insulation and locations.
1. Show locations of ductwork in area not in the heated envelope (shown on drawings for mech. permit)
2. All ducts to be sealed in accordance with the International Mechanical Code (M1601.4.1)
3. Ducts outside building envelope to be insulated with R-8, all other ducts with R-6
4. Building framing cavities shall not be used as supply ducts
5. Duct tightness test (section 403.2.2)
Duct tightness test is not required if air handler and ducts are ALL located within conditioned space
Duct tightness shall be verified by
a) Post construction test
Leakage to outdoors:<8 cfm/per 100 s.f. pf conditioned floor area or
Total leakage:<12 cfm/ pre 100
b) Rough-in test
Total leakage <6 cfm/per 100 s.f. of conditioned floor area
test at a pressure differential of .1 in w.g. (25 Pa) across rough-in system
#8 Air sealing details:
General note: All exterior joints are to be caulked, gasketed, weather stripped, or otherwise sealed. Floor
plates and sheathing joints are to be sealed. Refer to chart for locations and methods.
WALL INSULATION:
TYPICAL EXTERIOR WALL
5.5" BLOWN-IN BATT (R-4.23 PER INCH). =R-23.27 (R-20 MIN)
TYPICAL FOUNDATION WALL AT LIVING SPACE
5.5" BLOWN-IN BATT (R-4.23 PER INCH). = R-23.27
2" DRAIN AND DRY ON EXT. OF FDN WALL = R-10.00
TOTAL WALL R-VALUE =R-37.27 (R-19 MIN)
TYPICAL SLAB EDGE/FROST WALL FOUNDATION WALL
2" DRAIN AND DRY ON EXT. OF FDN WALL = =R-10.00 (R-10 MIN)
UNDER SLAB INSULATION:
2" RIGID INSULATION =R-10.00 (R-10 MIN)
3/4" SLAB EDGE INSULATION =R-7.00 (R-7 MIN)
CANTILEVERED FLOOR INSULATION:
11 7/8" BLOWN-IN BATT (R-4.23 PER INCH) =R-50.23 (R-30 MIN)
ROOF INSULATION:
12.5" OF BLOWN-IN BATT IN RAFTER SPACE =R-52.22 (R-49 MIN)
(R-4.23 PER INCH)
PROVIDE CORRAGATED AIR BAFFLE IN EACH RAFTER SPACE TO ALLOW AIR
FLOOR FROM LOW TO HIGH ON SHED ROOF FORMS. INSULATION IS TO BE BLOWN-IN
TIGHT TO THE ROOF REMAINING ROOF RAFTER SPACE. IN AREAS WITH DROPPED
CEILINGS, KEEP INSULATION AT ROOF RAFTERS, CREATING TEMPERED ATTIC IN VOIDS
--PROVIDE A VAPOR RETARDER AT BOTTOM OF RAFTERS
ROOF INSULATION AT SOUTH ROOF FORM OVER THE EAST UNIT'S STAIR, THE ROOF
INSULATION SHALL BE DIFFERENT THAN TYPICAL AND THE ROOF WILL BE UNVENTED.
(SEE KEY PLAN BELOW FOR LOCATION)
ROOF BAFFLE IS TO BE DELETED TO PROVIDE AN UNVENTED ROOF FORM.
Section of the IRC R806.5.
1 The unvented atic is completely withing the Building Thermal Envlope
2 No interior Class I vapor retarder are installed in the ceiling side of the unvented
attic assembly or on the ceiling side of the unvented enclosed roof framing.
3 (No wood shingle are used)
4 In climate zone 6, any air imperviable insualtion shall be class II vapor retarder
coating or covering in the direct contact with the underside of the structural sheathing.
5 Insulation shall be located in accordance with the following:
5.1 Item 5.1.1.1, 5.1.2, 5.1.3, OR 5.1.4 shall be met, depending on the air permiably of
the insulation directly under the structural roof sheathing:
5.1.3 Where both air permable and air impermable insualtion are provided, the
air impermable insulation shall be in direct contact with the underside of the structural roof
sheathing
4.5" OF SPRAY ON CLOSED CELL INSUALTION (AIR-IMPERMABLE)
(R-6.8 PER INCH) =R-30.6
10" UNFACED BATT (AIR-PERMABLE)
(R-4.23 PER INCH) =R-30.0
=R-60.8 (R-49 MIN)
(R-4.23 PER INCH)
THIS UNVENTED ROOF ASSEMBLY SHALL ALSO BE USED AT WATERPROOF DECKS
OVER CONDITIONED SPACE.
-- A VAPOR RETARDER IS NOT REQUIRED AT UNVENTED RAFTERS AND DECK JOISTS
OF WATERPROOF DECKS
WINDOWS:
FIXED =U-0.30
OPERABLE (AWNING AND CASEMENT) =U-0.30
PATIO DOOR AND SLIDING DOOR UNITS =U-0.30
INSULATION SUBCONTRACTOR MUST VERIFY THAT THE R-VALUES/U-VALUES OF
PROPRIETARY PRODUCTS MEET OR EXCEEDS THE VALUES LISTED ABOVE AND THAT
INSTALLATION PERFORMED IS PER MANUFACTURER'S SPECIFICATION. ALL WALL
INSULATION SHALL COMPLETELY FILL STUD SPACES AND HAVE PROPER AIR-BARRIER
SHEATHING ON BOTH SIDES OF THE STUD SPACES.
INTERIOR WALLS ARE TO RECEIVE UNFACED SOUND ATTENUATION BATTS FOR ALL
WALLS THAT DIVIDE HABITABLE ROOM
(EXAMPLE: BEDROOM TO CLOSET WALL DOES NOT NEED SOUND INSULATION
BEDROOM TO HALLWAY OR BEDROOM TO BEDROOM DOES)
2X6 = R-19
2X4 = R-13
DESIGN INSULATION VALUE SUMMARY
PARTY
WALL
crawlspace
PROVIDE
VAPOR BARRIER
OVER GRADE
AND UP
FOUNDATION
WALL AT LEAST
6" AND
TAPE/SEAL TO
WALL. R-13 ON
THE EXTERIOR
WALLS OF
CRAWLSPACE.
R-49 IN THE
FLOOR JOISTS
ABOVE. (VAPOR
BARRIER
AGAINST THE
FLOOR
SHEATHING)
92% MIN. EFF. OF BOILER
FOR RADIANT INFLOOR HEATING SYSTEM
PROVIDE SIDE ARM FOR HOT WATER
92% MIN. EFF. OF BOILER
FOR RADIANT INFLOOR HEATING SYSTEM
PROVIDE SIDE ARM FOR HOT WATER
FLUE ROUTING FOR BOILER.
(JOG FLUE ABOVE FOUNDATIN WALL)
BOILER
FLUE
RADON STACK PIPING TO
RISE THRU FLOOR ABOVE IN
THIS LOCATION
RADON STACK PIPING
IN THIS LOCATION
MECHANICAL
W101
MECHANICAL
E102
PARTY
WALL
ROOF FORM
WITHOUT VENTING 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:29 PMA0.3ECO SHEET16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado12" = 1'-0"
ECO SHEET NOTES
1/4" = 1'-0"
DESIGN INSULATION VALUES
1/8" = 1'-0"1 LOWER LEVEL KEY PLAN No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-171/8" = 1'-0"2 KEY ROOF PLAN
1
01/02/18
24
"COT
TONWOODEDGEOFASPHALTD AVO S TRAIL
50' RO W
LOT
18
ED
G
E
OF CONCRETE
LOT
BLOCK B
ASPE
N GR
OVE 4" P
I
N
E6" PI
NE
8
" P
I
NE8
" PI
NE
FOUND
#5REBA
RS3
6°37'14"E
-3
.99
'FR
OM L
OTCORN
E
RTV PE
D
1
2
" P
I
NE
FO
UND
11 _2"
B
LA
N
KAL
UM
I
NUMCAP FOU
ND
REBAREDGE OF ASPHALTFOU
ND
#
5
R
EBARWITHWA
SH
E
RRI
M E
L
=80
28
.
3
North
42'
44'
46'
48'
50'
52'
54'
56'
58'
60'
66'
68'
70'
34'
32'
32'
34'
36'
38'
42'
44'
46'
48'
50'
40'
52'
54'
56'
58'
60'
68'
70'
28'
30'
56'
56'
55'
BASI
SOF
BE
A
R
I
NGS
5
6°
1
1'37"
W
377.
1
1'BOUL
DE
R WAL
L
BOU
L
D
ER WAL
L
CUL
VERT I
NL
ETLOT9
LOT 1
0 LOT 1
7LOT 1
9LOT 8BUI
LD
I
NGCORN
E
R
BU
I
LD
I
NG
CORN
E
R
BUI
LD
I
N
GCO
RN
E
R15' SIDESETBACK15'SIDESETBACK15' BACK SETBACK
20'
FRONT
SETBACK
7'
UTILITY
EASEMENT
RECEPTION
NO.
103252
large evergreen trees
P Q TVCO
S8030
8040
80 50
806 0
80 70
DN
DN
DN
DN
DN
DN
DN
32/47/57'6
8047' - 2"
8031' - 9 3/4"
8030' - 0"
T.O. WALL
B.O. WALL
4'
T.O. WALL
B.O. WALL
3'8036'
8033'
8043'
8039'
8054' - 0"
8042' - 2"
8055' - 2"
T.O. WALL
B.O. WALL
4'8047'
8043'
T.O. WALL
B.O. WALL
4'8054'
8050'
T.O. WALL
B.O. WALL
4'8054'
8050'
T.O. WALL
B.O. WALL
6' 8060'
8054'
8%
5% <5% grade10' - 6 1/2"8% grade at centerline 18' - 9" 3'-0" pan at street
T.O. WALL
B.O. WALL
3'-3" 8041'-3"
8037'
T.O. WALL
B.O. WALL
3' 8049'
8046
T.O. WALL
B.O. WALL
2' 8039'
8037'
T.O. WALL
B.O. WALL
3'-3" 8045'3"
8042'
3'-0" pan at street
8030' - 6"
8029' - 0"
T.O. WALL
B.O. WALL
6' 8056'
8050'
8057' - 9"
MIN
2' - 0"
8049' - 6"
seat wall
17' - 6"
7' - 6"
hot tub
52'
54'
56'
58'
8049' - 7"
8032' - 10"
8031' - 4"
8032' - 11"
8037' - 1"
8041' - 11"
T.O. WALL
B.O. WALL
3'8035'
8032'
T.O. WALL
B.O. WALL
3'8037'
8034'
8036' - 11"
wall stepping downhill with grade
T.O. WALL
B.O. WALL
3' 8049'
8046'
4' - 6" 2' - 0"
8045' - 3"
T.O. WALL
B.O. WALL
4' 8047'
8043'
8040' - 3 1/2"
5' - 3" 8"
GUEST PARKING
EXTERIOR GUEST PARKING
EXTERIOR
22' - 2 1/2"
20' - 6"
Gas Meter
Gas meter
in grade under
porch over hang
elec meter,phone
and cable in side
wall of garage.
Provide 3'X3' flat
area in fron of
meter closet
connect to gas line in ditch
elec meter
phone
and cable
in side wall
of garage
WATERPROOF DECK AT MAIN LEVEL
WATERPROOF DECK AT MAIN LEVEL
WATERPROOF DECK AT UPPER LEVEL
SEW
E
R
SEW
E
R
SEWE
R
SEW
E
R
SE
W
E
R
SE
W
E
R
8034' - 3 1/4"
8032' - 1 3/8"
TV TV TV TV
TV
TV
TV
TV
TV
PHONE
PHONE PHONEPHONE PHONE PHONEPHONEPHO
N
E
CONNECT TO WATE R LINE IN STREET OR EASEM ENTWATER WATERCONNECT TO WATERLINE IN STREET OREASEMENTWATER WATER8%
5%25' - 0 5/8" 41' - 11 5/16"X X X X X X X X X X X X X X X X X X X X
XLIMITS OF DISTURBANCE FENCING
XX X X X X X X X X X X X X X X X LIMITS OF DISTURBANCE FENCINGWITH SILT FENCINGX
XX X X X X X X X X X X X X X LIMITS OF DISTURBANCE FENCINGWITH SILT FENCING PROVIDE JUTE
ROLES STAKED IN
DRAINAGE
DITCH/SWALES
(TYPICAL)
PROVIDE STRAW AND PLASTIC NETTING ON
SLOPES FOR ERROSION CONTROL AND TO
HOLD RESEEDING IN PLACE
CONNECT THE (2) CONCRETE PANS AT STREET.
CULVERTS WILL NOT BE REQUIRED (PER PUBLIC
WORKS REVIEW)
PROVIDE JUTE
ROLES STAKED IN
DRAINAGE
DITCH/SWALES
(TYPICAL)
8057' - 9"
8046' - 0"
WATERPROOF DECK AT UPPER LEVEL
T.O. WALL
B.O. WALL
6'8044'
8038'
undisturbed area
5197.5 s.f. 15' - 0 5/8"PARTY
WALL
T.O. WALL
B.O. WALL
4' 8062'
8058'21' - 3 5/8"MAX STAIR INTO SETBACK
7' - 6"
STAIR CONSTRUCTED OF THICK LIMESTONE PIECES IN
GROUPS OF 3. PROVIDE 3'-0" MIN LANDING AS MEASURED
AT CENTERLINE OF STAIR WALKWAY
MINIMUM TREAD = 11"
FD.
FD.
FD. FD.
CAST IN PLACE WALL8030'-1" ++ 8029-10"8029'-1" +8028'-10" +8029'-1" +8028'-10" +8030'-1" ++ 8029-10"8029'-7.6" +8030'-0.4" +8030'-6" +10' - 0"10' - 0" + 8029-11"+ 8030'-8.6"+ 8031'-1.4"+ 8031'-5.2"8028'
-11" +8029'-8.6" +10' - 0"8030'-4" +R @7 3/16"19
8054' - 7 1/2"8052' - 10 7/16"
8051' - 0 7/8"
8049' - 3 5/16"
8047' - 5 11/16"
8045' - 8 1/8"
8043' - 10 9/16"3'-0" MIN970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:31 PMA1.1SITE PLAN16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/8" = 1'-0"1 0.0 SITE PLAN
True
North
Project
North
Drive area:
West unit: 608 s.f. of drive
East unit: 503 s.f. of drive
Snow storage = (required =30% of Drive area):
West unit snow storage= 182.4 s.f. required, 200 s.f. provided
East unit snow storage= 150.9 s.f. required, 175 s.f. provided
Parking per unit = 3 spaces, (2 interior and 1 exterior)No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-1701/02/18
24
"COTT
O
NWO
O
D EDGEOFASPHALTD AVO S TRAIL
50' RO W
LOT
18
ED
G
E
OF CONCRETE
LOT
BLOCK B
ASPEN
GRO
VE
4
" PIN
E6" PI
N
E8" PI
N
E8
" P
I
NEF
OUND
#5REBARS3
6°37'14"E-3
.99
'
FROM
L
OT
CORN
E
R
TV PED
1
2
" PI
NE
FO
UND 11 _2"BLANKALUM
I
N
U
MCAPFOUN
D
R
EBAR
EDGE OF ASPHALT
FOUN
D
#5REBA
RWI
T
HWAS
HE
RR
I
M E
L
=8
0
2
8
.
3
North
42'
44'
46'
48'
50'
52'
54'
56'
58'
60'
66'
68'
70'
34'
32'
32'
34'
36'
38'
42'
44'
46'
48'
50'
40'
52'
54'
56'
58'
60'
68'
70'
28'
30'
56'
56'
55'
BASI
SOF
BE
A
R
I
NGS56°
11'37"W
377.
1
1'BOUL
DER WAL
L
BOULDER WAL
L
CUL
VERT I
NL
ET
LOT9
LOT 1
0 LOT 1
7LOT 1
9LOT 8BU
I
L
D
I
N
GCO
RNER
BU
I
L
D
I
NG CO
RNER
BUI
L
D
I
NGCORNE
R15' SIDESETBACK15'SIDESETBACK15' BACK SETBACK
20'
FRONT
SETBACK
7'
UTILITY
EASEMENT
RECEPTION
NO.
103252
large evergreen trees
P Q TVCOS80 30
8040
80 50
806 0
80 70
DN
DN
DN
DN
X X X X X X X X X X X X X X X X X X X X
LIMITS OF DISTURBANCE FENCING
XX X X X X X X X X X X X X X X X LIMITS OF DISTURBANCE FENCINGWITH SILT FENCINGX
XX X X X X X X X X X X X X X LIMITS OF DISTURBANCE FENCINGWITH SILT FENCING PROVIDE JUTE
ROLES STAKED IN
DRAINAGE
DITCH/SWALES
(TYPICAL)
PROVIDE STRAW AND PLASTIC NETTING ON
SLOPES FOR ERROSION CONTROL AND TO
HOLD RESEEDING IN PLACE
MAINTAIN TREE GROUPINGS IN EXISTING GROVE OF TRESS AS POSSIBLE AND PRACTICAL QA
L L
CE
QA
Q A
QA
CSLLLL LLCE
CS
FC
FC
CS
T RTR
TR
TR
T R
TR TR
TR
CREEPING
JUNIPER TO BE
ENCOURAGED TO
GROW DOWN ASD
UP BOULDER
WALL
PLANT A VARIETY
OF SEDUM
PLANTS IN
SPACES BETWEEN
BOULDERS
PERINNIALPLANTINGTR
T R
T R
T R
PERINNIAL PLANTING MIXED
IN WITH GROUND COVERS
CELLCELLLL
CE CE
CE
C E
CE C E LL L L 15' - 0".T R TR
LL
CE
C E
CE
EXTEROIR LIGHTING SHOWN ON THIS PLAN
2 LIFTS OF 1 1/2" OF
ASPHALT ON 4" GRAVEL
ROAD BASE
2 LIFTS OF 1 1/2" OF
ASPHALT ON 4" GRAVEL
ROAD BASE
PROVIDE JUTE
ROLES STAKED IN
DRAINAGE
DITCH/SWALES
(TYPICAL)
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP
SP SP
SP
SP
SP SP
T R
T R T R
T R
T R
LIGHTLIGHT
AT LL GARAGE AT LL GARAGE
LIGHT
AT ML DECK LIGHTAT ML ENTRYUPPER LVL DECK
RECESSED CAN IN SOFFIT
LIGHT
AT UL TERRACE LIGHTSTAIR STEP LIGHT
LIGHT
STAIR STEP LIGHT
LIGHT
STAIR STEP LIGHT
LIGHT
LIGHT
ST
A
IR STEP
LIG
HT
LIG
HT
LIG
HT
ENTRY AT JR. MASTER LVL
LIGHT
LIGHT
AT ML TERRACE
STAIR STEP LIGHT
LIGHT LIGHT
LIGHTLIGHT
AT LL GARAGE AT LL GARAGE
LIGHT
AT ML DECK
STEP LIGHT
IN WALL
LIGHTLIGHT LIGHTLIGHT
LIGHT LIGHT STEP LIGHT
IN WALL
LIGHTLIGHT
LIGHT 9 WALL TYICAM EXTERIOR FIXTURES (MOUNTED ABOVE 18")
1 RECESSED LIGHT AT UPPER LEVEL EAST DECK
TOTAL = 10 FIXTURES (<15 ALLOWED)
16 STEP LIGHTS
SP
SP
SP25' - 0 5/8"PARTY
WALL
LIGHT
FD. FD.
snow storage
snow storage
QA
Deciduous Trees
Count
QUAKING ASPEN
(POPULUS TREMULOIDES)
1.5" to 2.5" CAL.
Size
4
6
Symbol Name
Deciduous Shrubs
LL DWARF KOREAN LILAC
(SYRINGA MEYERI
'PALABIN')
OR Fendler ceanothus, mountain-lilac
#5. 10
42
CE #5 13COTONEASTER DAMMERI CORAL BEAUTY
(COTONEASTER DAMMERI)
GC
Perennial Ground covers
1000 square feet of cover.
CS
Conifer Trees
8'-10' tall 3
3
Colorado Spruce
(Picea pungens)
Mulched Areas
SHREDDED BARK MULCHED AREA - AROUND
TREES AND SHRUBS NOT COVERED BY GROUND
COVER
Natural Grass Areas (reveg)
MIX OF GRASSES AND FESCUE SEED. ARKANSAS
VALLEY SEED COMPANY, NATIVE LOW GROW
MOUNTAIN MIX. A SPRAY MIX OF FERTILIZER AND
SEED WILL BE APPLIED TO ALL DISTURBED
AREAS OF THE SITE AND BE TEMPORARY DRIP
IRRIGATED.
MULCH
NG Temporary Drip Irrigation as
needed to establish
GROUND COVER
NATURAL GRASS AREA
IRRIGATION NOTE:
1 ALL RESEEDED AREAS ARE TO TEMPORARY DRIP IRRIGATION
2 THE GROUND COVER AND PLANTING BEDS ARE TO RECIEVE PERMANENT
MICRO SPRAY AND DRIP IRRIGATION
TOTAL OF PERMANENT DRIP AND SPRAY IRRIGATION AREA OF 1,500 S.F.
SNOW IN SUMMER, STONECROP, CREEPING
PHLOX, NATIVE LOW-GROW GRASSES, ROCKY
MTN. FESCUE
1000 square feet of cover.
QA
CS
L LSP
T R
CE
TR
Evergreen Shrubs
Trailing Rosemary
(Rosmarinus officinalis 'prostratus')
20
20
#5.
SP #5 19SPIREA, ANTHONY WATERER
(Spiraea japonica ‘Anthony Waterer’)
1700 square feet of cover.
FC FRUITLESS FLOWERING CRABAPPLE
(Malus 'Spring Snow' ) (15' TALL MATURE HT)
2" CAL. 2
FC 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS7/5/2017 3:35:33 PMA1.2LANDSCAPE PLAN16702655 Davos TrailPERMIT SET04-28-17
Custom Duplex atVail Colorado1/8" = 1'-0"1 0.0 LANDSCAPE PLAN
1" = 10'-0"
LANDSCAPE PLANT LIST No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-1701/02/18
24
"COT
T
ONWO
ODEDGEOFASPHALTDAVO S TRAIL
50' R O W
LOT
18
ED
G
E
OF CONCRETE
BLOCK B
ASPEN GR
O
VE 4" PI
NE6" PI
NE8
" P
I
NE8
" PI
NE
FOUND
#5REBA
RS3
6°37'14
"
E-3
.99
'FROM
L
OTCORN
E
R
TV PE
D
1
2
" P
I
NEFOUND 11 _2"
B
LAN
KAL
UM
IN
UMCAPFOU
N
D
REBAR
EDGE OF ASPHALT
FO
UND #
5
R
E
BARWI
THWASH
ER
R
I
M E
L
=8
0
28
.
3
North
42'
44'
46'
48'
50'
52'
54'
56'
58'
60'
66'
68'
70'
34'
32'
32'
34'
36'
38'
42'
44'
46'
48'
50'
40'
52'
54'
56'
58'
60'
68'
70'
28'
30'
56'
56'
55'
BA
S
I
SOF
BE
A
R
I
NG
S
5
6°
11'37"W
377.11'BOUL
DE
R WAL
L
BOULDER WAL
L
CUL
VERT I
NL
ETLOT9
LOT 1
0
LOT 1
7LOT 1
9LOT 8BUI
LDINGC
OR
NE
RB
UI
LD
IN
G
C
ORNER
BUI
LD
I
N
GCO
RNE
R15' SIDESETBACK15'SIDESETBACK15' BACK SETBACK
20'
FRONT
SETBACK
7'
UTILITY
EASEMENT
RECEPTION
NO.
103252
large evergreen trees
P Q TVCO
S80 30
8040
8050
806 0
8070
DN
DN
DN
DN
X X X X X X X X X X X X X X X X X X X X
LIMITS OF DISTURBANCE FENCING
XX X X X X X X X X X X X X X X X LIMITS OF DISTURBANCE FENCINGWITH SILT FENCINGX
XX X X X X X X X X X X X X X LIMITS OF DISTURBANCE FENCINGWITH SILT FENCINGPROVIDE JUTE
ROLES STAKED IN
DRAINAGE
DITCH/SWALES
(TYPICAL)
PROVIDE STRAW AND PLASTIC NETTING ON
SLOPES FOR ERROSION CONTROL AND TO
HOLD RESEEDING IN PLACE
PROVIDE JUTE
ROLES STAKED IN
DRAINAGE
DITCH/SWALES
(TYPICAL)
Proposed DISTURBANCE OF 10,802 s.f. 68.5 %
41' - 9"JOB SIGN DUMPSTERCONSTRUCTION TLT
MATERIAL STAGING AND STORAGE IN DRIVEWAYS AND IN GARAGES
(CONTRACTOR TO OBTAIN THE PROPER RIGHT OF WAY PERMITS)
PARTY
WALL 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:35 PMA1.3CONSTRUCTION MGMT16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/8" = 1'-0"1 0.0 CONSTRUCTION MANAGEMENT No. Description Date01/02/18
UP
UP
DN
DND WDN
DN
UP
A3.0
A3.12
1 3' - 9"22' - 6" 22' - 11 1/2" 15' - 6 1/2" 13' - 5 1/2" 10' - 3 1/2"8031' - 0"
8%
8%
8031'-0"+
5%
8031' - 6"
2
A4.1
8030' - 0"
GUEST PARKING
EXTERIOR31' - 3"4' - 6 1/2" 1' - 5 1/2"10' - 3 1/2" 16' - 6" 8' - 6"8' - 0" 8034' - 6"
24' - 3" 25' - 2 1/2" 8"
1' - 2" 4' - 4" 21' - 1" 1' - 2"
1
A4.2
8034' - 3 1/4"
8032' - 1 1/8"
8034' - 6"
8031' - 0"
8032' - 0"
8030' - 9"
8031' - 3 3/16"
8032' - 10"
8032' - 11"5' - 8"5' - 7" 20' - 0" FD. FD.
1
4
A4.2
3
A4.1
1
A4.1
4' - 6 1/2" 18' - 5" 12' - 10" 8' - 2 1/2" 1' - 5 1/2"8032' - 6"
2
A4.3
8"
3' - 10 1/2"
R @ 6"4
2
A4.2
3
A4.2
1
A4.3
1' - 0" 24' - 0" 1' - 0"
8' - 5 1/2" 6" 3' - 6" 1' - 0" 3' - 6"
crawlspace
PROVIDE VAPOR
BARRIER OVER GRADE
AND UP FOUNDATION
WALL AT LEAST 6" AND
TAPE/SEAL TO WALL.
R-13 ON THE
EXTERIOR WALLS OF
CRAWLSPACE. R-49 IN
THE FLOOR JOISTS
ABOVE. (VAPOR
BARRIER AGAINST THE
FLOOR SHEATHING)
GUEST PARKING
EXTERIOR
elec meter
phone
and cable
in side wall
of garage
4
A4.1
< 5'-0" INTO FRONT SETBACK 4' - 11 3/4"8031' - 6"
GARAGE
W100
MECHANICAL
W101
MUD ROOM
W102
LAUNDRY
W103
RES. ENTRY
W104
COATS
W105
ENTRY
W106
JR. SUITE
BEDROOM
W107
WC
W108
BATH
W109
CLOSET
W110
GARAGE
E100
RES. ENTRY
E101
MECHANICAL
E102
SKI ROOM
E103
2
A4.4
FD. FD.
8032' - 6"
8032' - 0"
8032' - 0"
FD. FD.8034' - 5 3/4"
E100A
E100B
W108
W106
1
32
W107
W109
W110
W104
R @ 7 1/2" 3
W103W101
W100
E103
E102
LINEN
46' - 11 1/2"
14' - 9" 5' - 9"
1' - 5 1/2" 7' - 2 1/2" 15' - 7"
1' - 5 1/2" 6' - 10" 12' - 10 1/2" 3' - 4 1/2"
7" 1' - 2 1/2"
12' - 11 1/2" 6' - 10 1/2" 6' - 1 1/2" 9' - 5" 5' - 9"
5' - 4" 7' - 1" 3' - 8"4' - 0 1/2"3 1/2" 6' - 6 1/2" 3' - 4 1/2"2' - 0 1/2"
8" 3 '- 0".
4"18' - 0" 4" 3' - 8"
R @ 7 3/4"183' - 6"3' - 8" 4' - 1" 3' - 7" 11' - 8 1/2"5' - 3"19' - 3 1/2"7' - 6" 2' - 2 1/2" 3' - 10 3/16"
130°
R @ 6 1/2"9
R @ 6"8
R @ 6"34' - 0" 2' - 0" 8' - 2 3/4"8' - 0" 3' - 0"1' - 0"7' - 0" 4' - 7"
4' - 6"49' - 2 1/2"26' - 0" 18' - 11" 1' - 2" 26' - 7" 9' - 5"3' - 0" 11' - 0 1/2"5' - 3" 4" 18' - 0" 4" 2' - 8"
10' - 6" 3' - 5" 5' - 0" 10' - 0"2' - 0" planter to jog in partywall foundation12' - 0"1
A4.4
PARTY
WALL
7" 7"
7" 4' - 1"
column 3' - 2 3/4"1' - 8 3/4"column
12' - 9"2 1/2"1' - 6" 1
A5.2
92% MIN. EFF. OF BOILER
FOR RADIANT INFLOOR HEATING SYSTEM
PROVIDE SIDE ARM FOR HOT WATER
92% MIN. EFF. OF BOILER
FOR RADIANT INFLOOR HEATING SYSTEM
PROVIDE SIDE ARM FOR HOT WATER
3'x3' ACCESS DOOR INTO CRAWLSPACE
FLUE ROUTING FOR BOILER.
(JOG FLUE ABOVE FOUNDATIN WALL)
W105
8032' - 6"
8034' - 6"
BOILER FLUE
RADON STACK PIPING TO
RISE THRU FLOOR ABOVE IN
THIS LOCATION
RADON STACK PIPING IN
THIS LOCATION
6' - 0"
STEEL TUBE
DECK COLUMN
ON CONC. PIER
R @6 13/16"19
PROVIDE
1 1/2"x3/4" STEEL
BAR STOCK
RAILING AT STAIRS
WITH 4 OR MORE
RISERS. TOP OF
RAILING TO BE 3'-0"
ABOVE THE STAIR
NOSING . RAILING
TO RETURN TO
THE WALL OR
TURN DOWN TO
THE TOP OF
LANDING AT TOP
AND BOTTOM OF
STAIR1' - 0"1' - 0"1
20 min. door on self closing hinges
20 min. door
on self
closing
hinges
1
111"11"11" 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS7/5/2017 3:35:36 PMA2.0LOWER LEVEL PLAN16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0" 1 A1.0 LOWER LEVEL
True
North
Project
North
BLOWER DOOR TEST
N1102.4.1.2 (R402.4.1.2) Testing.
The building or dwelling unit shall be tested and verified as having an
air leakage rate of not exceeding 5 air changes per hour in Zones 1
and 2, and 3 air changes per hour in Zones 3 through 8. Testing shall
be conducted with a blower door at a pressure of 0.2 inches w.g. (50
Pascals). Where required by the building official, testing shall be
conducted by an approved third party. A written report of the results of
the test shall be signed by the party conducting the test and provided
to the building official. Testing shall be performed at any time after
creation of all penetrations of the building thermal envelope.No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-1701/02/18
DW DWUP
DN REF.DW
W D
REF. DN
DN
DN
DN
DN
UPREF.DN
DW
UP
DN
A3.0
A3.2
A3.12
A3.1
1
1
1
26' - 0"
bar
14' - 4 1/2" 15' - 4 1/2" 7" 7"
2 1/8"
3' - 5" 20' - 5 7/8" 2' - 0 1/2"3' - 9"1' - 5 1/2" 4' - 5 1/2"5' - 3 1/2" 8042' - 0"7' - 3 1/2" 1' - 3 1/2"1' - 3 1/2"3' - 10"4' - 10" 2
A4.1
20' - 6"
1' - 0"
8' - 0 1/2" 2' - 4 1/2" 2' - 1" 10' - 11"5' - 6 1/2"8' - 10" 10" 4' - 5 1/2" 9' - 1" 1' - 9" UNIT DIM7' - 0" 1' - 0" 15" deep pantry cabinets
8046' - 9 1/4"
8047' - 2"
7' - 6" 10' - 0"
8049' - 7"
1' - 5 1/2" 1' - 11" 3' - 8" 2' - 1 1/2" 12' - 0" 3' - 4 1/2" 7"
1' - 2 1/2"
6' - 7" 14' - 0 1/2" 8"
8' - 0 1/2"
24' - 3" 46' - 11 1/2" 14' - 9"
85' - 11 1/2"
1
A4.2
2' - 6" 5' - 5" 2' - 6"4 1/2"1' - 5 1/2" 13' - 8" 4' - 0" 5' - 9 1/2"21' - 0 1/2"18' - 4" 8030' - 9"
8041' - 11"
8047' - 0"
8034' - 6"
8042' - 0"
8049' - 6"
4
A4.2
GAS FIREPLACEGAS FIREPLACE HIGH WINDOWS3
A4.11
A4.1
12' - 6"9' - 0" 5' - 10 1/2"1' - 2"6' - 6" 5' - 6" 3' - 8" 3' - 0" 6' - 3"1' - 5" 5' - 5 1/2" 6' - 5 1/2" 4' - 0 1/4" 15' - 1 1/2" 9 1/4"4' - 0" 2' - 0 1/2" 4' - 1 1/2" 2
A4.3
8045' - 10"
2
A4.2
3
A4.2
1
A4.3
4
A4.1
POWDER
E206
DINING
E205
KITCHEN
E202
MUD ROOM
E207
LIVING
E200
ENTRY
E201
PANTRY
E203
LAUNDRY
E204
LIVING
W200
DINING
W201
KITCHEN
W202
POWDER
W203
LANDING
W204
MASTER
BEDROOM
W205
MASTER BATH
W206
WC
W207
M. CLOSET
W208
WEST TERRACE
WATERPROOF DECK
WATERPROOF DECK
ENTRY PORCH
2
A4.4
2
A4.4
3' - 10 1/2"
4' - 6"
COORDINATE WITH MULTI SLIDE UNIT DIM
16' - 0"
1' - 0"1' - 6"
11' - 0" 10' - 11" 1' - 2" 10' - 6 1/2" 16' - 0 1/2"
gas
fireplace
appliance
8044' - 8 11/16"
8042' - 0"8057'-8 1/2" top plate8062'-9 1/2" top plate3' - 2" 1
A4.4
1
A4.4 E200
E204
W206
W205A
W207
W208
W203
W200A
W200B
14 13
4
5
E206
E207
E201
33
20
21
W205B
76
32
31
25
26
2423
35
36
16 15
34
19 22
17
18
7' - 0" 6' - 8"22' - 6"18' - 4" 9' - 0"1' - 8" 9' - 2" 1' - 8" 3' - 2"9" 6' - 3"13' - 6" 16' - 10" 18' - 8"1' - 0"COORDINATE WITH MULTI SLIDE UNIT DIM12' - 2" +/- 2' - 4 1/2" 2' - 9 1/2" 10' - 0"STEP IN TOP OF FNDN WALL8' - 0" DEEP SET WINDOW
SEE UPPER LEVEL FOR TRAP WINDOW CALL OUTS 2' - 6"4' - 0" 2' - 7" 9' - 9" 4' - 7 1/2" 1' - 6" 3' - 0" 8' - 0"
LINE OF FRAMED WALL BELOW
6' - 0" 4' - 6 1/2"1"15' - 7"
9' - 5"
3' - 10 3/16" 5' - 0" 8"
PARTY
WALL
11 1/2" 7' - 2" 5' - 6" 1' - 1 1/2"
2' - 0" 5' - 2"
5' - 2 1/2"20' - 3 1/2"8' - 7 1/2" 10' - 7" 4' - 0" 2' - 0 1/2" 6' - 7 9/16"R @6 1/2"9
R @ 6"8
R @6"3
8037' - 0 3/4"
8037' - 0 7/16"
8032' - 11"
8032' - 10"
8031' - 4"
8041' - 11"6' - 6" 8' - 1"7"
2 1/8"
3' - 5" 6" 3' - 5" 2' - 6 7/8"
8042' - 2"top of finish
top of finish
top of finish
top of finish
top of finish
top of finish
top of finish
top of finish
top of finish
top of finish
8047' - 2"
7" 4' - 1" 22' - 6"
column
5
A5.1
STEEL TUB COLUMN
1
A5.2
JOG FLUE
DRYER EXHAUST
BOILER FLUE
RADON
STACK
PIPING
RADON STACK PIPING IN
THIS LOCATION
6' - 0" 10' - 0"FD.
FD.
CONSTRUCT A VAULT
FOR HOT TUB, CLAD IN
STONE VENEER
SERVICE ACCESS
ACCESS
SERVICE
PANEL
COORDINATE DOOR HEIGHT AND HEADER DEPTH
R @ 7 3/4"18
R @ 7 1/2"19
R @ 7 7/16" 21
PROVIDE A 1
1/2"x3/4" STEEL
BAR STOCK
RAILING AT
STAIRS WITH 4 OR
MORE RISERS.
TOP OF RAILING
TO BE 3'-0" ABOVE
THE STAIR
NOSING . RAILING
TO RETURN TO
THE WALL OR
TURN DOWN TO
THE TOP OF
LANDING AT TOP
AND BOTTOM OF
STAIR 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:38 PMA2.1MAIN LEVEL PLAN16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 A2.0 MAIN LEVEL
True
North
Project
North No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-1701/02/18
DN
DN
DN
DN
DN
DN
DN
A3.0
A3.2
A3.12
A3.1
1
1
1 22' - 6"6" 1' - 4" 8' - 6" 4' - 6" 9' - 11"
8055' - 0"
8042' - 0"
8055' - 0"
8055' - 0"
8057' - 9"
24' - 3" 24' - 6 1/2" 1' - 2" 8' - 11 1/2" 12' - 3 1/2" 6' - 4" 4' - 11" 3' - 6"
2
A4.1
71' - 2 1/2" 14' - 9"
5' - 4 1/2" 3' - 3 1/2" 2' - 5" 9 1/2" 12' - 0" 1' - 2" 4' - 9" 4' - 2 1/2" 12' - 3 1/2" 14' - 9"12' - 11"16' - 0" 4' - 1" 6' - 6" 4' - 0" 85' - 11 1/2"
1
A4.2
12' - 5 1/2" 12' - 5 1/2" 8' - 6" 15' - 4 1/2" 1' - 2" 3' - 10" 11" 5' - 1 1/2" 6' - 10" 4' - 6 1/2"6' - 0"2' - 5" 14' - 1" 8054' - 0"
A0.2
1
A0.2 3
A0.2
4
4
A4.2
4' GAS APPLIANCE
FIREPLACE
3
A4.1
1
A4.1 6' - 3"13' - 1" 4' - 2" 2
A4.3
2
A4.2
3
A4.2
1
A4.3 18' - 0 1/2"4' - 5 1/2" 8' - 6"
3' - 0 1/2"2' - 3 1/2" 3' - 7 1/2" 4' - 10 1/2"
4
A4.1
1' - 6"2' - 11" 4' - 5" 2
A4.4
FAMILY
W300
LANDING
W301
CLOSET
W302
BEDROOM
W303
BATH
W305
BEDROOM
W306
CLOSET
W307
BATH
W308
CLOSET
W309
BEDROOM
W310
FURR EXTERIOR WALL SO
THAT TLT WASTE CAN
CLEARLY PASS FOUNDATION
WALL BELOW
BATH
E302
BEDROOM
E303
CLOSET
E301
CLOSET
E306
MASTER
BATH
E305
MASTER
BEDROOM
E307
CLOSET
E308
BEDROOM
E309
LANDING
E300
WATERPROOF DECK
8' - 10" 3' - 5"
8' - 0 1/2"
BATH
W304
1
A4.4
4' - 0" 7' - 0" 4' - 1" 3' - 0" 2' - 5" 2' - 0"
109 8
COORDINATE TRANSOM TRAP WINDOWS WITH MULTI-SLIDE DOOR BELOW
8070' - 6" top plate
8066' - 1" top plate
PARTY
WALL
PARTY
WALL
7" 7" 13' - 10 1/2"12' - 10 1/2" 8066' - 1" top plate8066' - 1" top plate
39
E309B
E305BE306
E303A
W303
47
46
W306
W310
W307
E310
E308
E304
E305A
E303B
73
75
74
76
W309W308
77
38
E309A
54
52
53
51
50
49
60
5958
57
6261
6667
70
71 69 68
63
64
65
E307B
E301
72
E302
E307A
5655
44
W305
37
W300
W304
W302
5' - 0" 3' - 6"
WC
E304
HIGH WINDOWSTOP OF FINISHTOP OF FINISH
8065' - 1" top plate
5' - 7 1/2" 14' - 4 1/2" 4' - 2" 1' - 0" 6' - 3" 5' - 10"7"10' - 6 1/2" 8' - 5 1/2" 5' - 1" 2' - 6" 9' - 5"9"1' - 0"
23' - 10 1/2" 3' - 0" 22' - 6"8' - 1"8072' - 3 3/4" top plate15' - 2"8063' - 1" top plate5' - 9"16' - 9 1/2" 7' - 6" 4' - 2 1/2"R @ 7 1/2"19 5 1/2"3' - 8" 8' - 9 1/2" BATH
E310
40
8070' - 6" top plate
41 42
5
A5.1
8055' - 2"
3' - 10 1/2"
1
A5.2
JOG RADON PIPING IN
M BATH CEILING VOID
TO GET PROPER
CLEARANCE FROM
BOILER FLUE
WDW 48 IS
HIGH ANS
CENTERED
ON STAIR
13' - 0"
2' - 8 1/2"
BOILER FLUE
RADON STACK PIPING IN
THIS LOCATION
8069' - 10" top plate
8067' - 10" top plateCOORDINATE DOOR LOCATION
WITH FLUE PIPE RUN
8055' - 0"
8054' - 7 1/2"
8054' - 0"TOP OF SLAB
TOP OF SLAB
8054' - 7 1/2"
TOP OF SLAB
CONSTRUCT A VAULT FOR HOT TUB, CLAD IN STONE VENEER
TOP OF SEAT TO BE 18" ABOVE ADJACENT PATIO HEIGHT
SERVICE ACCESS
FD. FD.1' - 7"FLUE CHASE FROM MAIN LEVEL FIREPLACE
5'
-
6"
120
°
v erify2' - 0 "RUN FLUE FROM MASTER FP TO
CHIMNEY MASS ON ROOF
1' - 3 7/16"
1
A5.1
R @ 7 7/16" 21 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS7/5/2017 3:35:40 PMA2.2UPPER LEVEL PLAN16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 A3.0 UPPER LEVEL No. Description Date01/02/18
24"COTTONWOODEDGEOFASPHALTFOUND 1
1 _2"BLANKALUM
I
NUMCAP42'
44'
46'
48'
50'
52'
54'
56'
58'
60'
6'
'
'
40'32'
34'
36'
38'
42'
44'
46'
48'
50'
40
52
54
56
58
6
56'
56'
55'AL
L 15' SIDESETBACK15'SIDESETBACK20'
FRONT
SETBAC K
8040
8050
8060
DN
DN
DN
DN
DN
A3.2
A3.12
A3.1
1
1
1
2
A4.1
1
A4.2
1
A0.2 3
A0.22
A0.2
4
4
A4.2
nat grade :8043'-0"
Finshed grade at drive 8032'-0"
ridge:
bldg ht =32'-11"
3:12
nat grade :8044'-0"
fin. grade :8032'-0"
DECK:
bldg ht =15'-2"
8034' - 4 7/8"
nat grade :8044'-6"
terrace below: 8034 4 3/4"
parapet:
bldg ht =23'-4"
nat grade :8050'-3"
ridge:
bldg ht =23'-9 1/2"nat grade :8043'-0"
ridge:
bldg ht =29'-0"
8071' - 5 3/4"
nat grade :8046'-0"
finishes grade :8039'-9"
ridge:
bldg ht =31'-2 1/4"
nat grade :8040'-0"
ridge:
bldg ht =30'-6"
nat grade :8043'-6"
finished grade" 8036'-9"
ridge:
bldg ht =27'-1 3/8"
8036' - 9"8063' - 10 3/16"
8070' - 5 9/16"
nat grade :8039'-0"
fin. grade :8031'-0"
DECK:
bldg ht =11'-2"
8042' - 2"
nat grade :8040'-6"
fin. grade :8034'-0"
DECK:
bldg ht =21'-3"
8055' - 2"
3:12 2:123:12 2:12ASPHALT SHINGLES ON WATERPROOFING
MEMBRANE ON ROOF SHEATHING ON ROOF
RAFTERS
(TYPICAL)
3
A4.1
1
A4.1
2
A4.3
2
A4.2
3
A4.2
1
A4.3
8057' - 11"
8073' - 11 3/16"
8064' - 11"
8072' - 1"
4
A4.1
2
A4.4
ASPHALT SHINGLES ON WATERPROOFING
MEMBRANE ON ROOF SHEATHING ON ROOF
RAFTERS
(TYPICAL)
4' - 0"
2' - 6" 2' - 6" 1' - 6"8"1' - 6"2' - 6"1' - 6"2' - 8 15/16"2' - 6"5' - 0"6' - 0"2' - 0"3' - 0"3' - 6"2' - 0"this roof is over livable area
below, therefore this does
not count as grfa
21' - 3 1/4"
8040' - 3 1/2"
1
A4.4
PARTY
WALL
5
A5.1
1
A5.2
1
A5.1
SNOW BRAKE
SNOW BRAKE
SEE STRUCTURAL
DETAIL
SNOW BRAKE
SEE STRUCTURAL
DETAIL 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:41 PMA2.3ROOF PLAN & HT CALC16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 A4.0 ROOF PLAN No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-1701/02/18
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
A1.9 MASTER LVL
8045' - 10"2' - 6"15' - 2"11' - 4"2' - 6" B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"13' - 0"11' - 0" B2.7 UPPER LVL
8055' - 0"3' - 6"10' - 9"15' - 0" 8' - 4"10' - 9" 1
A4.2
4' - 10 1/2"4' - 1 1/2" 1' - 11" 13' - 0"11' - 0" 8' - 4"13' - 10"VERTICAL ACCENT SIDING AT CORNER WINDOW TRIM
1x8 BARNWOOD SIDING ON THERMAL AND AIR
INFILTRATION BARRIER ON SHEATHING ON 2X6
STUD WALL WITH R-25 BIBBS INSULATION
ALUM CLAD WOOD WINDOWS
HIGN DEF. TRI-LAM ASPHALT SHINGLES WATERPROOFING
MEMBRANE ON WOOD ROOF SHEATHING ON ROOF RAFTERS-
R59.22 BIBS INSULATION
STONE VENEER ON DRAINAGE MEDIUM
ON THERMAL AND AIR INFILTRATION
BARRIER ON SHEATHING ON 2X6 STUD
WALL WITH R-25 BIBBS INSULATION
WEST TERRACE
8036' - 9"
PLANTER
EARTHEN BERM
BETWEEN HOMES
3 :12
ALUM. GARAGE DOOR WITH
TRANSLUCENT GLASS PANELS
LIGHT FIXTURE
ADDRESS NUMBERS
4
A4.2
RECTILINEAR CUT STONE ON THICKSET MOTAR
BED ON DRAINAGE MEDIUM (MIRA-DRAIN WITH
FILER FAFRIC) ON 2 LAYERS OF WATERPROOF
MEMBRANE ON SHEATHING ON FLOOR JOISTS
WITH SLOPED TOP TO GUTTER/DRAIN
GAS METER GAS METER
3
A4.1
1
A4.1 2
A4.2
3
A4.2
23' - 5"4
A4.1
METAL PANEL AT CORNER AND
BETWEEN WINDOWS/DOORS
STONE VENEER CHIMNEY. sTONE VENEER
ON DRAINAGE MEDIUM ON THERMAL AND
AIR INFILTRATION BARRIER ON SHEATHING
ON WOOD STUDS
HORIZONTAL 2x12 SHIPLAPPED SIDING ON
THERMAL AND AIR INFILTRATION BARRIER ON
SHEATHING ON 2X6 STUD WALL WITH R-25 BIBBS
INSULATION
METAL PANEL ON MASS OVER ENTRY
ENTRY DOOR
ENTRY DOOR
WEST 'A' EAST 'B'
METER CLOSET
High Plate Height
(West)
8072' - 3 3/4"East-West High
Plate Height
8070' - 6"
West Living Room
High Plate Height
8062' - 9 1/2"
East Partywall Plate
Height
8063' - 1"
PARTY
WALL
East Master High
Plate Height
8069' - 10"
W106
W100
3
1
2
W200B
8 9 10
8' - 0"4' - 0" 4' - 0"
17
19 22
20
21
23
24
25 12' - 0"
E200
34
33
E201
39
W300
43 44 45
46
47
8068' - 1"
BTM OF HDR
8065' - 7"
BTM OF HDR
50 51
52 E307AE309A
57 59
58 60
W205B
3:1 2
5
A5.1
1
A5.2
LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB
WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE
MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF
MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30+ BLOWN
IN BATTS INSULATION BETWEEN JOISTS.
40
41
42
48 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:45 PMA3.0SOUTH ELEVATION16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 South Elevation
Door Schedule
Mark Width Height Comments
E310 2' - 6" 8' - 0"
W100 18' - 0" 8' - 0"
W101 3' - 0" 8' - 0"
W103 3' - 0" 8' - 0"
W104 3' - 0" 8' - 0" 20 min. door on self
closing hinges
W105 2' - 6" 7' - 0"
W106 4' - 0" 9' - 0"
W107 2' - 10" 8' - 0"
W108 2' - 6" 8' - 0"
W109 2' - 6" 8' - 0"
W110 2' - 6" 8' - 0"
W200A 8' - 0"9' - 0"
W200B 8' - 0"9' - 0"
W203 2' - 6" 8' - 0"
W205A 2' - 10" 8' - 0"
W205B 6' - 0" 8' - 0"
W206 2' - 6" 8' - 0"
W207 2' - 6" 8' - 0"
W208 2' - 6" 8' - 0"
W300 3' - 0" 8' - 0"
W302 4' - 6" 8' - 0"
W303 2' - 10" 8' - 0"
W304 2' - 6" 8' - 0"
W305 2' - 6" 8' - 0"
W306 2' - 10" 8' - 0"
W307 2' - 6" 8' - 0"
W308 2' - 6" 8' - 0"
W309 5' - 0" 8' - 0"
W310 2' - 10" 8' - 0"
Door Schedule
Mark Width Height Comments
E100A 18' - 0" 8' - 0"
E100B 3' - 0" 8' - 0" 20 min. door on self
closing hinges
E102 3' - 0" 8' - 0"
E103 3' - 0" 8' - 0"
E200 8' - 0"10' - 0"
E201 3' - 6" 8' - 0"
E204 2' - 10" 8' - 0"
E206 2' - 6" 8' - 0"
E207 2' - 6" 8' - 0"
E301 2' - 6" 8' - 0"
E302 2' - 6" 8' - 0"
E303A 3' - 0" 8' - 0"
E303B 2' - 10" 8' - 0"
E304 2' - 4" 8' - 0"
E305A 3' - 0" 8' - 0"
E305B 2' - 6" 8' - 0"
E306 2' - 6" 8' - 0"
E307A 3' - 0" 8' - 0"
E307B 2' - 10" 8' - 0"
E308 5' - 0" 8' - 0"
E309A 3' - 0" 8' - 0"
E309B 2' - 10" 8' - 0"
EAST UNIT DOOR SCHEDULE WEST UNIT DOOR SCHEDULE
16' - 0" 4 PANEL SLIDER XOOX
12' - 0" MULTI PANEL LIFT AND SLIDE
12' -0" MULTI PANEL LIFT AND SLIDE
DOOR NEEDS TO BE 7' TO FIT UNDER
STAIR-VERIFY HT IN FEILD
No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-171
1
01/02/18
A2.0 MAIN LEVEL
8047' - 0"
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.0 LOWER
LEVEL
8032' - 0"
8056' - 0"
8054' - 0"
8050' - 0"
8047' - 3" 8047' - 2"
8049' - 7"
8048' - 0"
EXISTING GRADE
EXISTING AND PROPOSED GRADE
8043' - 0"
8047' - 0"
8038' - 0"
8042' - 0"
8036' - 0"3:123:122
A4.31
A4.3
2
A4.4
1
A4.4
West Living room
Plate Height
8057' - 8 1/2"3:12top of finish inside top of finish outside
4 5 W200A 6
7
37 38
1
A5.1
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
EXIST I NG GRA DE 7' - 6"8054' - 0"
8041' - 11"
METAL CORNER TRIM
8037' - 0 1/4"
8032' - 10 1/16"
A4.2
4
2
A4.3
1
A4.3
31' - 8 7/8"2
A4.4
High Plate Height
(West)
8072' - 3 3/4"East-West High
Plate Height
8070' - 6"
1
A4.4
East master bath
Plate Height
8065' - 1"
East Master High
Plate Height
8069' - 10"
26
11 12
13 15
31
32
33
34
E201
35 36
49
53 55
54 56
61
62
63 64
5' - 0" 5' - 0"
8063' - 3"
65
8063' - 4"
BTM OF HDR
3' - 3"10' - 1"8' - 3"2:12
DRYER VENT OT SIDE WALL
1
A5.1 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:49 PMA3.1EAST AND WEST ELEVATIONS16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 West Elevation
1/4" = 1'-0"2 East Elevation
No. Description Date01/02/18
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.1
1
A4.2
23' - 9"24' - 8"4
A4.2
3
A4.1
1
A4.1
2
A4.2
3
A4.2
4
A4.1
High Plate Height
(West)
8072' - 3 3/4"
PARTY
WALL
East master bath
Plate Height
8065' - 1"
8057' - 9"
COUNTERFORTS
REVIEW WITH STRUCTURAL
CRAWLSPACE UNDER THIS PORTION
66
E305A
67
E303A
68 69
70
71 72
73 74 75 76 77
3:12
2:128056' - 6"
8056' - 0"
5
A5.1
1
A5.2
25' - 11"R308.4.3 Glazing in windows.
Glazing in an individual fixed or operable panel that meets all of
the following conditions shall be considered a hazardous
location AND tempered glass is to used as glazing:
1. The exposed area of an individual pane is larger than 9
square feet (0.836 m2);
2. The bottom edge of the glazing is less than 18 inches
(457 mm) above the floor;
3. The top edge of the glazing is more than 36 inches
(914 mm) above the floor; and
4. One or more walking surfaces are within 36 inches
(914 mm), measured horizontally and in a straight line,
of the glazing.
WINDOW NOTES:
1. ALL WINDOWS SHALL BE DOUBLE-PANED ALUM. CLAD WOOD WINDOWS
UNLESS OTHERWISE NOTED.
2. U-VALUE OF .30 MAXIMUM (SEE INSULATION SUMMARY).
3. ALL WINDOWS TO RECEIVE LOW-E TREATMENT.
4. ALL SIZES SHOWN ARE NOMINAL. CONTRACTOR TO VERIFY ROUGH-
OPENING SIZES WITH CHOSEN WINDOW MANUFACTURER.
5. WINDOWS MUST DISPLAY MANUFACTURER SPECS INCLUDING R-VALUES
PRIOR TO COUNTY INSPECTIONS.
6. LOW AWNING WINDOWS SHALL RECEIVE MANUFATURERS' OPENING LIMITER
AS REQUIREED BY BUILDING CODE
7. CONTRACTOR AND WINDOW SUPPLIER TO CONFIRM ALL LOCATIONS OF
TEMPERED GLASS AND PROVIDE ACCORDINGLY.
8. ALL SLIDING AND HINGED PATIO DOORS ARE TO BE PROVIDED BY THE
WINDOW MANUFACTURE. DOORS THAT ARE TALLER THAN WINDOW
MANUFACTURER PRODUCES MAY BE PROVIDED BY ANOTHER
MANUFACTURE, BUT FINISHES SHALL BE THE SAME AS TYPICAL.
9. ALL TRAPAZOIDE WINDOWS ARE TO BE FIELD VERIFIED FOR SIZE AND
SLOPE. TRAPAZIODE WINDOWS TYPICALLY SHOULD BE THE SAME SLOPE
AS THE ROOF CEILING ABOVE.
10. COORDINATE THE TRANSOM WINDOW SIZES SO THAT THE OVERALL WIDTH
MATCHES THAT OF DOORS BELOW 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/17/2017 2:18:44 PMA3.2NORTH ELEVATION16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 North Elevation
Window Schedule
Mark Family Width Height Level Comments
60 Window-Picture 5' - 0" 5' - 0" B2.7 UPPER LVL
61 Window-Picture 3' - 0" 5' - 0" B2.7 UPPER LVL
62 Window-Casement 3' - 0" 5' - 0" B2.7 UPPER LVL
63 Window_Trapezoide 5' - 0" 4' - 0" B2.7 UPPER LVL
64 Window_Trapezoide 5' - 0" 3' - 2" B2.7 UPPER LVL
65 Window-Picture 5' - 0" 5' - 0" B2.7 UPPER LVL tempered
66 Window-Casement 2' - 6" 5' - 0" B2.7 UPPER LVL tempered
67 Window-Awning 4' - 0" 2' - 6" B2.7 UPPER LVL tempered
68 Window-Awning 3' - 0" 2' - 0" B2.7 UPPER LVL
69 Window-Awning 2' - 6" 2' - 0" B2.7 UPPER LVL tempered
70 Window-Casement 2' - 6" 5' - 0" B2.7 UPPER LVL tempered
71 Window-Picture 4' - 6" 7' - 0" B2.7 UPPER LVL tempered
72 Window-Casement 2' - 6" 5' - 0" B2.7 UPPER LVL tempered
73 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL
74 Window-Picture 4' - 6" 4' - 6" A3.0 UPPER LEVEL
75 Window-Casement 3' - 0" 5' - 0" A3.0 UPPER LEVEL tempered
76 Window-Picture 4' - 6" 5' - 0" A3.0 UPPER LEVEL tempered
77 Window-Casement 3' - 0" 5' - 0" A3.0 UPPER LEVEL tempered
Window Schedule
Mark Family Width Height Level Comments
32 Window-Awning 5' - 0" 2' - 0" B1.7 MAIN LEVEL
33 Window-Picture 5' - 6" 3' - 6" B1.7 MAIN LEVEL
34 Window-Picture 2' - 0" 6' - 0" B1.7 MAIN LEVEL tempered
35 Window-Awning 3' - 0" 2' - 6" B1.7 MAIN LEVEL
36 Window-Awning 3' - 0" 2' - 6" A2.0 MAIN LEVEL
37 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL
38 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL
39 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL
40 Window-Picture 4' - 0" 4' - 6" A3.0 UPPER LEVEL tempered
41 Window_Trapezoide 4' - 0" 3' - 0" A3.0 UPPER LEVEL tempered
42 Window_Trapezoide 4' - 0" 4' - 0" A3.0 UPPER LEVEL
43 Window-Awning 3' - 0" 2' - 0" A3.0 UPPER LEVEL
44 Window-Picture 5' - 6" 7' - 0" A3.0 UPPER LEVEL tempered
45 Window-Awning 3' - 0" 2' - 0" A3.0 UPPER LEVEL
46 Window-Casement 3' - 0" 5' - 0" A3.0 UPPER LEVEL
47 Window-Picture 5' - 6" 7' - 0" A3.0 UPPER LEVEL
48 Window-Picture 3' - 0" 3' - 0" B2.7 UPPER LVL
49 Window-Picture 2' - 0" 4' - 0" B2.7 UPPER LVL tempered
50 Window_Trapezoide 3' - 0" 2' - 6" A3.0 UPPER LEVEL
51 Window_Trapezoide 4' - 0" 3' - 4" A3.0 UPPER LEVEL
52 Window-Picture 4' - 0" 5' - 0" B2.7 UPPER LVL
53 Window-Picture 3' - 6" 4' - 0" B2.7 UPPER LVL tempered
54 Window-Casement 3' - 6" 5' - 0" B2.7 UPPER LVL
55 Window-Picture 2' - 0" 4' - 0" B2.7 UPPER LVL
56 Window-Casement 2' - 0" 5' - 0" B2.7 UPPER LVL
57 Window-Picture 3' - 0" 5' - 0" B2.7 UPPER LVL
58 Window-Casement 3' - 0" 5' - 0" B2.7 UPPER LVL
59 Window-Picture 5' - 0" 5' - 0" B2.7 UPPER LVL
Window Schedule
Mark Family Width Height Level Comments
1 Window-Casement 3' - 0" 6' - 0" A1.5 Jr MASTER LVL tempered
2 Window-Awning 3' - 0" 2' - 0" A1.5 Jr MASTER LVL
3 Window-Picture 6' - 0" 6' - 0" A1.5 Jr MASTER LVL
4 Window-Casement 3' - 6" 5' - 0" A2.0 MAIN LEVEL tempered
5 Window-Picture 5' - 0" 5' - 0" A2.0 MAIN LEVEL tempered
6 Window-Casement 3' - 0" 6' - 0" A2.0 MAIN LEVEL tempered
7 Window-Awning 3' - 0" 2' - 0" A2.0 MAIN LEVEL
8 Window_Trapezoide 4' - 0" 1' - 3" A2.0 MAIN LEVEL
9 Window_Trapezoide 4' - 0" 2' - 3" A2.0 MAIN LEVEL
10 Window_Trapezoide 8' - 0" 3' - 3" A2.0 MAIN LEVEL
11 Window-Picture 4' - 0" 5' - 0" A2.0 MAIN LEVEL
12 Window-Picture 3' - 0" 5' - 0" B2.7 UPPER LVL
13 Window-Picture 4' - 0" 6' - 0" A2.0 MAIN LEVEL
14 Window-Awning 4' - 0" 2' - 0" A2.0 MAIN LEVEL
15 Window-Picture 3' - 0" 6' - 0" A2.0 MAIN LEVEL
16 Window-Awning 3' - 0" 2' - 0" A2.0 MAIN LEVEL
17 Window-Picture 6' - 0" 8' - 0" A1.9 MASTER LVL tempered
18 Window-Picture 3' - 0" 8' - 0" A1.9 MASTER LVL tempered
19 Window-Awning 3' - 0" 2' - 3" A1.9 MASTER LVL
20 Window-Casement 3' - 0" 5' - 0" A1.9 MASTER LVL tempered
21 Window-Awning 3' - 0" 2' - 6" A1.9 MASTER LVL
22 Window-Picture 6' - 0" 2' - 3" A1.9 MASTER LVL
23 Window-Picture 4' - 0" 4' - 6" A2.0 MAIN LEVEL tempered
24 Window-Awning 4' - 0" 2' - 6" B1.7 MAIN LEVEL tempered
25 Window-Picture 4' - 0" 7' - 0" B1.7 MAIN LEVEL tempered
26 Window-Picture 3' - 0" 7' - 0" B1.7 MAIN LEVEL tempered
31 Window-Picture 5' - 0" 7' - 0" B1.7 MAIN LEVEL
12" = 1'-0"
WINDOW SCHEDULE NOTES
No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-13-171
1
1
added location of tempered glazing
01/02/18
A2.0 MAIN LEVEL
8047' - 0"
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
A3.0 UPPER LEVEL
8057' - 9"
A1.0 LOWER
LEVEL
8032' - 0"9' - 3" 1' - 0"2
A4.3
1
A4.3
2
A4.4
GARAGE
W100
LAUNDRY
W103
RES. ENTRY
W104
LIVING
W200
KITCHEN
W202
BEDROOM
W306
LANDING
W301
1
A4.4
8032' - 6"
8032' - 0"
9' - 7 1/2"25' - 3"8" 25' - 11"1' - 4 1/4"1 1/2" 1' - 2"3/4"11' - 1"8057' - 0"10' - 9"15' - 2" existing grade line
1 1/2"9' - 6 1/4"STEEL BEAM
EXPOSED TO VIEW
ON THIS SIDE
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
2
A4.3
1
A4.3
2
A4.4
High Plate Height
(West)
8072' - 3 3/4" East-West High
Plate Height
8070' - 6"
West Living Room
High Plate Height
8062' - 9 1/2"
1
A4.4
LANDING
W301
BATH
W304
LANDING
W204
ENTRY
W106
CLOSET
W110
POWDER
W203 8' - 4"12' - 9"3 3/4"7 1/2"11"
11"7 3/4" A2.0 MAIN LEVEL
8047' - 0"
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE
8031' - 0"
2
A4.3
1
A4.3
10' - 1 1/4" 10' - 8 1/4"2
A4.4
High Plate Height
(West)
8072' - 3 3/4"East-West High
Plate Height
8070' - 6"
West Living Room
High Plate Height
8062' - 9 1/2"
1
A4.4
FAMILY
W300
BEDROOM
W303
MASTER
BEDROOM
W205
M. CLOSET
W208
MASTER BATH
W206
JR. SUITE
BEDROOM
W107
BATH
W10912' - 9"10' - 7 5/16"8' - 4"0"West Living room
Plate Height
8057' - 8 1/2"
11 12
13 15
1814 16
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
2
A4.3
1
A4.3
7' - 6 7/8"8' - 6 7/8"2
A4.4 High Plate Height
(West)
8072' - 3 3/4"8' - 4"East-West High
Plate Height
8070' - 6"
West Living Room
High Plate Height
8062' - 9 1/2"
1
A4.4
CLOSET
W110
ENTRY
W106GARAGE
W100
LANDING
W204
POWDER
W203
KITCHEN
W202
BATH
W305
LANDING
W301
2' - 0"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS7/5/2017 3:35:54 PMA4.1BUILDING SECTIONS16702655 Davos TrailPERMIT SET04-28-17
Custom Duplex atVail Colorado1/4" = 1'-0"1 Section 6 1/4"= 1'-0"2 Section 1
1/4" = 1'-0"3 Section 5
1/4" = 1'-0"4 Section 11 No. Description Date01/02/18
Plate Height
8066' - 1"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.3
1
A4.3
2
A4.4 East-West High
Plate Height
8070' - 6"
1
A4.4
RES. ENTRY
E101
GARAGE
E100SKI ROOM
E103
MUD ROOM
E207
POWDER
E206 LIVING
E200
LANDING
E300
CLOSET
E301
BATH
E302
BATH
E310
8' - 6 7/8"3' - 4 1/8" R @ 7 7/16"21
1
A5.1
R @6 13/16"19
11' - 0"7' - 6 7/8"4' - 4 1/2"
PROVIDE 2 LAYERS OF 5/8" TYPE
'X' GWB ON UNDERSIDE OF STAIR
A4.2
5
STAIR OPENING/SHAFT IS
LARGE ENOUGH (3'-10")AND
THE STAIR NARROW
ENOUGH (3'-7") THAT THE
GUARD WITH THE
GRASPABLE RAIL PASSES
WITH MORE THAN 1 1/2" OF
CLEARANCE. THE
GRASPABLE RAIL RETURNS
TO THE WALL AT THE TOP
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.3
1
A4.3
2
A4.4
1
A4.4
East master bath
Plate Height
8065' - 1"
East Master High
Plate Height
8069' - 10"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.3
1
A4.3
East master bath
Plate Height
8065' - 1"
MASTER
BATH
E305
MASTER
BEDROOM
E307
PANTRY
E203
KITCHEN
E202
East Master High
Plate Height
8069' - 10"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
1
A4.3
8041' - 11"
8037' - 0 1/2"3' - 1" 3"8045' - 0"
11"7 3/16"3'-0" TO TOP OF RAILWOOD STAIR TREADS
AND RISERS
1' - 2"PROVIDE 2
LAYERS OF 5/8"
TYPE 'X' GWB ON
UNDERSIDE OF
STAIR
NOSING
1"
11" TREADS
TYP6 13/16"3"3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 2" TUBE STEEL, PAINTED
(BLACK)
1 1/2"x3/8" STEEL BAR STOCK 3/4"2 1/4"3 3/4"3/8"1 3/4"2"x3/8" STEEL BAR STOCK
2"x3/4" STEEL BAR STOCK
GRASPABLE RAILING
EASE ALL EDGES SO THAT
THEY ARE SMOOTH
3' - 0 1/2"INTERIOR GUARD
3 7/8"3' - 0 1/2"INTERIOR STAIR RAILING
3 11/16"
11" 1' - 0" 2' - 5 5/8"2"3/8" 3/43/3 3/4" 1 3/4"3/4"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/13/2017 4:01:10 PMA4.2BUILDING SECTIONS16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 Section 2
1/4" = 1'-0"2 Section 4
1/4" = 1'-0"3 Section 9
1/4" = 1'-0"4 Section 3 No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-13-17PROVIDE A 1 1/2"x3/4" STEEL BAR STOCK RAILING AT
STAIRS WITH 4 OR MORE RISERS. TOP OF RAILING TO BE
3'-0" ABOVE THE STAIR NOSING . RAILING TO RETURN TO
THE WALL OR TURN DOWN TO THE TOP OF LANDING AT
TOP AND BOTTOM OF STAIR
1
1/2" = 1'-0"5
STAIR DETAIL AT EAST UNIT GARAGE
TO MAIN LEVEL
1" = 1'-0"6 INTERIOR GUARD AND RAILING .
01/02/18
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.1
1
A4.2
4
A4.2
3
A4.1
1
A4.1
2
A4.2
3
A4.2
4
A4.1
8' - 4"1' - 2 3/4" 9' - 6 1/4" 1' - 2 3/4" 13' - 11 1/4" High Plate Height
(West)
8072' - 3 3/4"
25' - 4 1/2"
12' - 5 1/2" 12' - 6" 15' - 9 1/2"PARTY
WALL
East Master High
Plate Height
8069' - 10"
BEDROOM
W310
BEDROOM
W306
LANDING
W301
FAMILY
W300
MASTER
BEDROOM
W205
LANDING
W204
KITCHEN
W202DINING
W201
GARAGE
W100
RES. ENTRY
W104
JR. SUITE
BEDROOM
W107
LANDING
E300
MASTER
BEDROOM
E307
LIVING
E200
GARAGE
E100
A5.1
4
A2.0 MAIN LEVEL
8047' - 0"
A3.0 UPPER LEVEL
8057' - 9"
Plate Height
8066' - 1"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.1
1
A4.2
4
A4.2
3
A4.1
1
A4.1
14' - 6 3/4"2
A4.2
3
A4.2
4
A4.1
High Plate Height
(West)
8072' - 3 3/4"
3:12
East Partywall Plate
Height
8063' - 1"
8050' - 6"
TOP OF FOUNDATION WALL AT HOT TUB
PARTY
WALL
East Master High
Plate Height
8069' - 10"
BEDROOM
E309
MASTER
BEDROOM
E307
LIVING
E200
FAMILY
W300
BEDROOM
W310
LIVING
W200
MASTER
BEDROOM
W205 LANDING
W204
GARAGE
W100
ENTRY
W106
JR. SUITE
BEDROOM
W107 1' - 1"10' - 8 1/4"5
A5.1
1
A5.2
UNDERFRAME CEILING TO
MATCH ROOF OF
SOUTHERN PORTION 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS7/5/2017 3:35:58 PMA4.3BUILDING SECTIONS16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 Section 10
1/4" = 1'-0"2 Section 7 No. Description Date01/02/18
A2.0 MAIN LEVEL
8047' - 0"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.1
1
A4.2
3
A4.1
1
A4.1
2A4.2
4
A4.1
West Living Room
High Plate Height
8062' - 9 1/2"
East Partywall Plate
Height
8063' - 1"
8062' - 6 1/4"
PARTY
WALL
8' - 1"West Living room
Plate Height
8057' - 8 1/2"
LIVING
W200
LANDING
W204
GARAGE
W100
GARAGE
E100
RES. ENTRY
E101
LIVING
E200
BATH
E310
BEDROOM
E309
5
A5.1
3" 10' - 5 1/2"1 1/2"10 1/8"1 1/2"1
A5.2
thick wall for multi slide
9 1/4"
8067' - 10"
8"9' - 4 3/8"A2.0 MAIN LEVEL
8047' - 0"
A1.0 LOWER
LEVEL
8032' - 0"
A1.5 Jr MASTER
LVL
8034' - 6"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
2
A4.1
1
A4.2 3
A4.1
1
A4.1
2
A4.2
4
A4.1
3" 9' - 2 7/8"1' - 2 5/8"9' - 0" 1' - 0"10' - 8 1/2"3:12
West Living Room
High Plate Height
8062' - 9 1/2"15' - 9 1/2"7" 4' - 6" 21' - 6"9' - 3" 1' - 0" 5' - 0"East Partywall Plate
Height
8063' - 1"13' - 0" 8' - 1" 8036' - 6"2' - 0"3:12
6" 10' - 6"PARTY
WALL
West Living room
Plate Height
8057' - 8 1/2"
LIVING
W200
GARAGE
W100
GARAGE
E100
BATH
E310
1
A5.2
R.O.9' - 2 7/8"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:35:59 PMA4.4BUILDING SECTIONS16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1 Section 15
1/4" = 1'-0"2 Section 12 No. Description Date01/02/18
R-19 (MIN) BLOWN-IN
INSULATION TO FILL 2X STUD
FURRING WALL CAVITY.
GYPSUM WALL BOARD HELD UP
FROM SLAB 3/8"
TREATED WOOD BOTTOM
PLATE SEALANT UNDER PLATE
FOR CAPILLARY BREAK.
(R-10) UNDER-SLAB
INSULATION
HEATED CONCRETE SLAB
(IN-FLOOR RADIANT HEATING SYSTEM)
GRANULAR FILL - INCLUDE
SOIL-GAS VENTILATION
SYSTEM
REFER TO STRUCTURAL DRAWINGS
FOR FOUNDATION/FOOTING DESIGN
AND REINFORCEMENT
(R-5) 3/4" RIGID INSULATION
FOR THERMAL BREAK
SLOPED 4" PERFORATED DRAIN
PIPE. ALL FOUNDATION WALLS
INCLUDING INTERIOR WALLS.
RE: SOILS REPORT
COARSE GRANULAR FILL
FILTER FABRIC
DAMPROOFING OR W.P.
MEMBRANE FOR
CAPILLARY BREAK
FREE-DRAINING BACKFILL
(R-10) 2-3/8" DRAIN & DRY" DRAINAGE
BOARD OVER WATERPROOFING (FROM
FOOTING TO 8" BELOW FINISHED GRADE)
5/8" TYPE "X" GYPSUM
WALL BOARD
SLOPED 4" SOLID DRAIN
FROM GUTTER &
DOWNSPOUT UNDER-
DRAIN SYSTEM. (MAY BE
LOCATED HIGHER, BUT AT
LEAST 4'-0" BELOW
FINISHED GRADE NEAR
BUILDING)
ALTERNATE SYSTEM:
COMPOSITE DRAINAGE BOARD WITH
FILTER FABRIC EXTEND FROM 8" BELOW
GRADE TO FOOTING OVER 2" RIGID
INLSULATION (TO A DEPTH OF 4'-0"
BELOW GRADE) OVER WATERPROOFING.
INTERIOR SPACE
BASE TRIM
ADDITIONAL 4" PERFORATED DRAIN
PIPE AT 10'-0" VERTICAL SPACING AT
ALL UPHILL FOUNDATION WALLS IN
EXCESS OF 15' IN HT
WATERPROOF MEMBRANE TO EXTEND FROM
FOOTING TO 6" ABOVE FINISHED GRADE
1
A1.5 Jr MASTER
LVL
8034' - 6"
A1.9 MASTER LVL
8045' - 10"
B 0.5 GARAGE
8031' - 0"
B1.7 MAIN LEVEL
8042' - 0"
B2.7 UPPER LVL
8055' - 0"
PARTY
WALL
GA FILE NO. WP 3810
BASE LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
APPLIED AT RIGHT ANGLES TO 2X6 WOOD STUDS AT
24" O.C. WITH 6d COATED NAILS, 1 7/8" LONG. 1/4"
HEADS, 16" O.C.
FACE LAYER: 5/8" SOUNDBREAK XP APPLIED AT RIGHT
ANGLES TO STUDS OVER BASE LAYER AND TOP AND
BTM PLATES WITH 8d COATED NAILS, 2 3/8" LONG,
0.099" SHANK, 9/32" HEADS, 8" O.C. JOINTS OFFSET 24"
FROM BASE LAYER JOINTS.
INNER LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
WITH 6d COATED NAILS, 1 7/8" LONG, .0915 SHANK, 1/4"
HEADS, 8" O.C. JOINTS IN INNER LAYER NEED NOT BE
TAPED.
SECOND WALL DUPLICATED OF FIRST WALL AND
SEPARATED BY 1 3/4" SPACE. WALLS ARE
INDEPENDANTLY LOADED. WALLS TO RECIEVE
5 1/2" BLOWN-IN INSULATION. (LOAD BEARING)
LANDINGE300
MASTER
BEDROOM
W205
LIVING
E200
3"
7"7"
1 3/4"
JR. SUITE
BEDROOM
W107
GARAGE
E100
4' - 0"
5/8" GWB APPLIED TO THE
UNDER SIDE OF ROOF
SHEATHING FOR A DISTANCE
OF 4'-0" FROM PARTY WALL AT
LOCATION WHERE THE ROOF
PLANES ARE LESS THAN 30"
PROVIDE 5/8" TYPE 'X'
GYPSUM WALL BOARD
AT RIM JOIST
SO THAT THE WALL
ASSEMBLY HAS A TOTAL
OF 2 LAYERS FOR
HEIGHT OF WALL
PROVIDE 5/8" TYPE 'X'
GYPSUM WALL BOARD
AT RIM JOIST
SO THAT THE WALL
ASSEMBLY HAS A TOTAL
OF 2 LAYERS FOR
HEIGHT OF WALL
A3.0 UPPER LEVEL
8057' - 9"
A1.9 MASTER LVL
8045' - 10"
East-West High
Plate Height
8070' - 6"1' - 2"OVERHANG
1' - 6"BLOCK BCI WEB AT
BEARING POINTS
1 1/2"SLOPED BLOCKING
'D' SHAPED DRIP FLASHING
(LEG LONG ENOUGH TO COVER 2X6 FASCIA)
WITH DRIP HEM AT BOTTOM
2x12 FASCIA
ALUM. SOFFIT VENT WITH
BUG SCREEN.
PROVIDE AT BOTH AT
LOW SIDE OF ROOF AND
AT HIGH
TL ASPHALT SHINGLES ON FULL COVERAGE WATERPROOF
MEMBRANE ON ROOF SHEATHING ON 12 1/2" BCI/LVL ROOF
RAFTERS WITH BLOWN-IN BATT R-59.22 INSULATION BETWEEN
RAFTERS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL
BOARD ON CEILING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
HEAD FLASHING AT ALL WINDOW AND DOOR HEADS
VERTICAL WOOD SIDING ON THERMAL AND AIR INFILTRATION
BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL
FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN
STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X'
GYPSUM WALL BOARD ON WALL
VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS.SHIM SPACE1"SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS
see strcut for min.11"1' - 0" 2" WATERPROOF MEMBRANE TO TURN DOWN AND OVERLAP FASCIA
WATER PROOF MEMBRANE FROM DECK TO TURN UP WALL MINIMUM OF 2'-0". EXTEND UNDER DOOR THRESHOLDS, LAP DOOR THRESHOLD VYCOR OVER
DRAINAGE MEDIUM IS TO STOP
3" FROM EDGE. PROVIDE ROPE
WICKS AT 2'-0" O.C. ALONG EDGE
EDGE FLASHING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
5/8" TYPE 'X' GYPSUM WALL BOARD
VYCORE TAPE NAILING FLANGE AT TOP OF WINDOW
SEAL/FOAM THE PERIMETER OF ALL PENATRATIONSSTEP DOWN FROM INTERIOR TO EXTERIOR 1/2" TO 1"BOTTOM OF WALL FLASHING
2x14 DECK EDGE
1x6 T&G SOFFIT
ALUM CLAD WOOD WINDOW 4" MAXIMUM SPACING TO BTM RAILVYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS.
1x6 T&G SOFFIT
STONE VENEER ON DRAINAGE MEDIUM SYSTEM ON
THERMAL AND AIR INFILTRATION BARRIER ON 1/2"
SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH
BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM
WALL BOARD ON WALL
8043' - 6"
8043' - 7"
ENTRY
W106
FAMILY
W300
LANDINGW204
R-58 BLOWN-IN BATTS INSULATION 3"3"12' - 9"METAL PANEL SYSTEM
WITH CONCEALED FASTENERS
3"9 1/4" 8068' - 1"9' - 8" 3/4" 9 1/4" 2 1/4" 1' - 2 3/4"11' - 11"MC 10x8.4 STEEL CHANNEL AT EDGE OF DECKS3"SPACER AT
GUARD
CONNECTION
CORRUGATED AIR BAFFLE
1x6 T&G SOFFIT
1 1/2" AIR GAP
LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB
WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE
MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF
MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30 SPRAY
FOAM INSUALTION AND BATT INSULATION BETWEEN JOISTS.
East Partywall Plate
Height
8063' - 1"
PARTY
WALL
5/8" GWB APPLIED TO THE
UNDER SIDE OF ROOF
SHEATHING FOR A DISTANCE
OF 4'-0" FROM PARTY WALL AT
LOCATION WHERE THE ROOF
PLANES ARE LESS THAN 30"
PROVIDE 5/8" TYPE 'X' GWB TO
THE UNDERSIDE OF THE
OVERHANG AND UNDER
FASCIA TO CREATE A FIRE
PROTECTED OVERHANG
SUBSTITUTE THE 1/2" EXTERIOR PLYWOOD
WALL SHEATHING WITH EXTERIOR GWB
FOR PORTION OF WALL THAT FACES WEST
LARGE RECTILINEAR STONE TILE ON
MORTAR ON 3" CONCRETE SLAB WITH
RADIANT HEATING SYSTEM TUBING ON J
DRAIN 1000 DRAINAGE
MEDIUM/PROTECTION (OR SIMILAR) ON 2
LAYERS OF WATERPROOF MEMBRANE ON
3/4" SHEATHING ON SLOPING TOP CUT
LVLS. R-30+ BLOWN IN BATTS INSULATION
BETWEEN JOISTS.
BOTTOM OF WALL FLASHING
'D' SHAPED DRIP FLASHING
(LEG LONG ENOUGH TO COVER 2X6 FASCIA)
WITH DRIP HEM AT BOTTOM
WATERPROOF MEMBRANE
TO TURN DOWN AND
OVERLAP FASCIA
1 1/2"GA FILE NO. WP 3810
BASE LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
APPLIED AT RIGHT ANGLES TO 2X6 WOOD STUDS AT
24" O.C. WITH 6d COATED NAILS, 1 7/8" LONG. 1/4"
HEADS, 16" O.C.
FACE LAYER: 5/8" SOUNDBREAK XP APPLIED AT RIGHT
ANGLES TO STUDS OVER BASE LAYER AND TOP AND
BTM PLATES WITH 8d COATED NAILS, 2 3/8" LONG,
0.099" SHANK, 9/32" HEADS, 8" O.C. JOINTS OFFSET 24"
FROM BASE LAYER JOINTS.
INNER LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD
WITH 6d COATED NAILS, 1 7/8" LONG, .0915 SHANK, 1/4"
HEADS, 8" O.C. JOINTS IN INNER LAYER NEED NOT BE
TAPED.
SECOND WALL DUPLICATED OF FIRST WALL AND
SEPARATED BY 1 3/4" SPACE. WALLS ARE
INDEPENDANTLY LOADED. WALLS TO RECIEVE
5 1/2" BLOWN-IN INSULATION. (LOAD BEARING)
3"
BOTH WALLS ARE INDEPNDANTLY BEARING AND THE ROOF
AND ROOF OVERHANG IS COVERED IN 5/8" TYPE 'X' GWB
PROVIDING THE FIRE SEPARATION PROTECTION FROM EACH
UNIT
SEE STRUCTURAL DETAIL
FOR BLOCKING AND
ANCHORAGE
PROVIDE 5/8" TYPE 'X' GYPSUM WALL BOARD AT
RIM JOIST SO THAT THE WALL ASSEMBLY HAS A
TOTAL OF 2 LAYERS FOR HEIGHT OF WALL
SPRAY FOAM INSUALTION ON
UNDERSIDE OF STRUCTURAL ROOF
SHEATHING/GWB (R-30 AT 4.5") AND
10" FIBERGLASS BATT INSUALTION
970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/5/2017 3:36:00 PMA5.1DETAILS16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1" = 1'-0"3 TYPICAL FOUNDATION DETAIL
1" = 1'-0"4 PARTY WALL SECTION
1 1/2" = 1'-0"5
WALL SECTION AT WEST UNIT, SOUTH
WALL
1" = 1'-0"1
WALL SECTION AT PARTYWALL WITH
ROOF OVERHANG
No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-5-171
1
1
01/02/18
A2.0 MAIN LEVEL
8047' - 0"1 1/2"'D' SHAPED DRIP FLASHING
(LEG LONG ENOUGH TO COVER 2X6 FASCIA)
WITH DRIP HEM AT BOTTOM
2x12 FASCIA
TL ASPHALT SHINGLES ON FULL COVERAGE WATERPROOF
MEMBRANE ON ROOF SHEATHING ON 14" BCI/LVL ROOF
RAFTERS, CORREGATED AIR BAFFEL, WITH BLOWN-IN BATT
R-52.22 INSULATION BETWEEN RAFTERS.MEMBRANE VAPOR
RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON CEILING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS.
SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS
WATERPROOF MEMBRANE TO TURN DOWN AND OVERLAP FASCIA
ALL TRAPAZOIDE WINDOWS ARE TO BE FIELD VERIFIED FOR SIZE AND SLOPE.
TRAPAZIODE WINDOWS TYPICALLY SHOULD BE THE SAME SLOPE AS THE
ROOF/CEILING ABOVE.
COORDINATE THE TRANSOM WINDOW SIZES SO THAT THE OVERALL WIDTH
MATCHES THAT OF DOORS BELOW
PLACE 3/4" RIGID INSULATION IN
PLANCE OF 5/8" GYPSUM WALL BOARD
UNDER TRIM AT LOCATION BETWEEN
WINDOWS WITH STEEL HEADER
HORIZONTAL METAL PANEL CLOSURE PIECE BETWEEN WINDOWS
1' - 0" 2"LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB
WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE
MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF
MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30 SPRAY
FOAM INSUALTION AND BATT INSULATION BETWEEN JOISTS.
DRAINAGE MEDIUM IS TO STOP
3" FROM EDGE. PROVIDE ROPE
WICKS AT 2'-0" O.C. ALONG EDGE EDGE FLASHING
DASHED LINE REPRESENTS VAPOR RETARDER LOCATION
BOTTOM OF WALL FLASHING AT LOCATIONS WITHOUT DOOR
MC 10X8.4 STEEL CHANNEL AT EDGE OF DECKS
1x6 T&G SOFFIT3"WATERPROOF MEMBRANE FROM DECK TO TURN UP
WALL MINIMUM OF 2'-0". EXTEND UNDER DOOR
THRESHOLDS, LAP DOOR THRESHOLD VYCOR OVER
TRESHOLD, SET IN SEALANT
5' - 6"3"3' - 11" STONE VENEER ON DRAINAGE MEDIUM SYSTEM ON
THERMAL AND AIR INFILTRATION BARRIER ON 1/2"
SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH
BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM
WALL BOARD ON WALL
3" STONE WALL CAP, SLOPE TO EXTERIOR
4' - 6 1/2"
1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH
BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS.
MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL
BOARD ON WALL
HORIZONTAL WOOD SIDING ON THERMAL AND AIR INFILTRATION
BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL
FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN
STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X'
GYPSUM WALL BOARD ON WALL
WEATHERSTRIPPING AT HEAD AND JAMBS OF GARAGE DOOR
SEMI-TRANSLUCENT GLASS PANELS IN ALUM. OVERHEAD DOOR
(REVIEW BELT LIFT FOR QUIETER OPERATION)
STOP INSULATION TO TEMPER THE VOID UND THE HEATED DECK3" SLAB2 1/4".minimumsee struct forSPACER AT
GUARD
CONNECTION
W12x26
INSULATE EAVES AT
LOCATIONS WITH STEEL
BEAMS IN ROOF PLANE
1
1
DRAINAGE MEDIUM IS TO STOP
3" FROM EDGE. PROVIDE ROPE
WICKS AT 2'-0" O.C. ALONG EDGE
EDGE FLASHING
MC 10X8.4 STEEL CHANNEL AT EDGE OF DECKS
SPACER AT
GUARD
CONNECTION
3 3/4" 2" 3' - 0 1/4"2 7/8"3 3/4" 3/8"3 3/4" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 2 7/8"2"1 3/4"IPEA TOP CAP WITH
SLOPED TOP
2" TUBE STEEL, PAINTED
(BLACK)
1 1/2"x3/8" STEEL BAR STOCK3"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 2" TUBE STEEL, PAINTED
(BLACK)
1 1/2"x3/8" STEEL BAR STOCK 3/4"2 1/4" 3 3/4"3/8"1 3/4"2"x3/8" STEEL BAR STOCK
2"x3/4" STEEL BAR STOCK
GRASPABLE RAILING
EASE ALL EDGES SO THAT
THEY ARE SMOOTH
3' - 0 1/2"INTERIOR GUARD
3 7/8"3' - 0 1/2"INTERIOR STAIR RAILING
3 11/16"
11"1' - 0" 2' - 5 5/8"2"3/8" 3/3/3/43 3/4 " 1 3/4"3/4"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/13/2017 4:01:10 PMA5.2DETAILS16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1 1/2" = 1'-0"1
WALL SECTION AT WEST UNIT, LIVING
ROOM ROOF AND DECK, SOUTH WALL No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-13-171" = 1'-0"2 EXTERIOR GUARD DETAIL
INTERIOR RAILS AND GUARD DETAIL ARE SIMILAR
1
1" = 1'-0"3 INTERIOR GUARD AND RAILING
01/02/18
REF.DW
W D
DW
2
A4.1
1
A4.2
4
A4.2
3
A4.1 1
A4.1
2
A4.3
2
A4.2
3
A4.2
1
A4.3
4
A4.1
2
A4.4
1
A4.4
PARTY
WALL
crawlspace
PROVIDE VAPOR
BARRIER OVER GRADE
AND UP FOUNDATION
WALL AT LEAST 6" AND
TAPE/SEAL TO WALL.
R-13 ON THE
EXTERIOR WALLS OF
CRAWLSPACE. R-49 IN
THE FLOOR JOISTS
ABOVE. (VAPOR
BARRIER AGAINST THE
FLOOR SHEATHING)
SD
CM
D
A A
A A
DSD
TO LIGHTS ON
LANDING AND
SWITCH
ABOVE
D
LLLLA.Sub-Flr
dropped ceiling
10' - 7"
A.Sub-Flr
dropped ceiling
11' - 7"
A.Sub-Flr
dropped ceiling
10' - 7"
A.Sub-Flr
dropped ceiling
9' - 7"
A.Sub-Flr
dropped ceiling
9' - 1"
ceiling at btm of
structure above
10'-1"EA
DD D G G GJ
t
KK
K K
K
J
J
E E E
A wp A wp A wp
A AA A
D DD
D
TO SCONCE
LIGHT,
LANDING
RECESSED
AND SWITCH
ABOVE
KK
K K
K K
D
KEYLESS
FIXTURE IN
CRAWL
3'x3' ACCESS DOOR INTO CRAWLSPACE
L LLL LTO LANDING
STEP LIGHTS
AND ENTRY
LIGHTS ABOVEgfcigfci
SD CM
SD
CM
gfcigfci
gfci
gfci
gfci
gfci
gfci gfcigfcigfcigfcigfcigfcigfcigfci
gfci
gfci
gfci
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
A wp
D
E
F
G
J
K
L
5" RECESSED CAN LIGHT (wet location)
5" RECESSED CAN LIGHT (sloped ceiling fixture)
5" RECESSED CAN LIGHT (directional spot)
CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT)
A 5" RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
H FLUORESCENT CLOSET LIGHT
BATH FAN
2x4 FLUORESCENT FIXTURE
SURFACE MOUNT
STEP LIGHT
M COVE LIGHTING (LED TAPE)
1/2 HOT DUPLEX OUTLET
NOTES:
1 PROVIDE DOOR BELL CHIME AT EACH LEVEL.
2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE
LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR
3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE
DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL
4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS
B
C
t THERMOSTAT
SD
CM
SMOKE DETECTOR
CO SENSOR/DETECTOR
SWITCH
INTERIOR LIGHTING NOTE
GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
ARC-FAULT CIRCUIT INTERRUPTER
AFCI protection is required on all branch circuits supplying
outlets or devices installed in dwelling unit kitchens, family
rooms, dining rooms, living rooms, parlors, libraries, dens,
bedrooms, sunrooms, recreation rooms, closets, hallways,
laundry areas, and similar rooms and areas.
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15
AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A
COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/13/2017 4:01:11 PMA6.0LOWER LEVEL RCP16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1
A1.0 LOWER LEVEL RCP AND ARCH
LIGHTING PLAN
1/4" = 1'-0"
ELECTRICAL LEGEND No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-13-1701/02/18
REF.DW
W D REF. REF.DW
2
A4.1
1
A4.2
4
A4.2
3
A4.1 1
A4.1
2
A4.3
2
A4.2 3
A4.2
1
A4.3
4
A4.1
2
A4.4
1
A4.4
PARTY
WALL
A
D1' - 5 1/2"D
D
bar type pendant
M M Min knee space
A A A
A
A
A
G GA A A A
G G G G
t
B
B
B
B
B
B BCC D
A
D
D F
A A
A AC
CA
A A
A A
A
A wp A wp
J
J
J
D
A.Sub-Flr
dropped ceiling
9' - 1" M
M MMA.Sub-Flr
dropped ceiling
9' - 8"
A.Sub-Flr
dropped ceiling
9' - 1"
A.Sub-Flr
dropped ceiling
9' - 1"
CEE E E EE E
A
J
D
D D D D
D
steel beam
M. CLOSET
W208
MASTER
BEDROOM
W205
LANDING
W204
LIVING
W200
KITCHEN
W202
DINING
W201
POWDER
W203
MASTER BATH
W206
WC
W207
A.Sub-Flr
dropped ceiling
9' - 1"
A.Sub-Flr
dropped ceiling
9' - 1"
A
A
A.Sub-Flr
dropped ceiling
9' - 1"
A.Sub-Flr
dropped ceiling
9' - 1"
CEILING AT 11'-9 1/4"
CEILING AT 11'-9 1/4"
A
A A
A A A A A
AA A
D
steel beam
D
fireplace
8057'-6 1/4" top plate8062'-9 1/2" top plateCEILING AT 9'-6 1/4"
E
A
E
E
L
L
L LLCCAA
AA
AA AL L L L L LL
L
review in-floor outlet location for living room
review in-floor outlet location for living room
G G
fireplace
fireplace
CEILING AT
BTM OF
STRUCTURE
ABOVE
11'-9 1/4"
A
A
A G GG G
TO LIGHTS ON
LANDING AND
SWITCH
BELOW
TO LIGHTS ON
LANDING AND
SWITCH
ABOVE
t
ETO LIGHTS ON
LANDING AND
SWITCH
BELOW
TO LIGHTS ON
LANDING AND
SWITCH
ABOVEE A
A
TO STEP
LIGHTS AND
EXTERIOR
GARAGE WALL
LIGHTS BELOW
TO SWITCH ABOVE
J
G
G GG GG REVIEW LIGHTS
ON TOP OF
CABINETS TOO
SD
CM
SD
SD
CM
3:12
D
D
1
A5.1
SD
gfci
gfci
gfci
EXTERIOR OUTLET gfciOUTDOOR RECEPTACLES
ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND
BE GFCIgfci EXTERIOR OUTLET
OUTDOOR RECEPTACLES
ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND
BE GFCI
gfciEXTERIOR OUTLET
gfciEXTERIOR OUTLET
gfci
EXTERIOR OUTLET gfcigfcigfcigfcigfcigfcigfci
gfci
gfci
gfci gfci
gfci
gfci
gfci
gfci
gfcigfcigfcigfcigfcigfcigfcigfcigfci gfci gfcigfcigfciA wp
D
E
F
G
J
K
L
5" RECESSED CAN LIGHT (wet location)
5" RECESSED CAN LIGHT (sloped ceiling fixture)
5" RECESSED CAN LIGHT (directional spot)
CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT)
A 5" RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
H FLUORESCENT CLOSET LIGHT
BATH FAN
2x4 FLUORESCENT FIXTURE
SURFACE MOUNT
STEP LIGHT
M COVE LIGHTING (LED TAPE)
1/2 HOT DUPLEX OUTLET
NOTES:
1 PROVIDE DOOR BELL CHIME AT EACH LEVEL.
2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE
LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR
3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE
DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL
4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS
B
C
t THERMOSTAT
SD
CM
SMOKE DETECTOR
CO SENSOR/DETECTOR
SWITCH
INTERIOR LIGHTING NOTE
GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
ARC-FAULT CIRCUIT INTERRUPTER
AFCI protection is required on all branch circuits supplying
outlets or devices installed in dwelling unit kitchens, family
rooms, dining rooms, living rooms, parlors, libraries, dens,
bedrooms, sunrooms, recreation rooms, closets, hallways,
laundry areas, and similar rooms and areas.
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15
AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A
COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS7/13/2017 4:01:13 PMA6.1MAIN LEVEL RCP16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1
A2.0 MAIN LEVEL RCP AND ARCH
LIGHTING PLAN
1/4" = 1'-0"
ELECTRICAL LEGEND No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-13-1701/02/18
2
A4.1
1
A4.23
A4.1 1
A4.1
2
A4.3
2
A4.2 3
A4.2
1
A4.3
4
A4.1
2
A4.4
1
A4.4
PARTY
WALL
5
A5.1
1
A5.2
F
SD
CM
B
B
B B
B
B
D
J
t
B B
TO BELOW
BB BB
J
J
F
F
F
B B
B B
D
B B
B B
BB
B B
A wpE
A
E E E E
A wp A wp
A
t
F
B B
A.Sub-Flr
dropped ceiling
9' - 9" A.Sub-Flr
dropped ceiling
9' - 9"
3:12
3:12 2:122:123:12 2:123:12
3:12
3:12
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8' - 4"
A.Sub-Flr
dropped ceiling
8'- 4"
A.Sub-Flr
dropped ceiling
8' - 4"
8070' - 6" top plate
8066' - 1" top plate 8066' - 1" top plate8066' - 1" top plate
8065' - 1" top plate 8072' - 3 3/4" top plate8069' - 10" top plate
8067' - 10" top plate8063' - 1" top plate2:122:128070' - 6" top plate 8070' - 6" top plate
D
TO SCONCE
AND SWITCH
BELOW
A.Sub-Flr
dropped ceiling
9' - 9"
FB
B B
B
B
D
A CCFI
REPLACED
DJ
J
J
E E
A wp
F
BB
B B
D
E E A wp
B
B
HOT TUB DISCONNECT
OFFSET RADON VENT
PIPE/STACK
A.Sub-Flr
dropped ceiling
10' - 1"
A.Sub-Flr
dropped ceiling
10' - 1"
A wp
A wp
A wp
A wp
E E TO STEP LIGHTS
TO 5 LANDSCAPE LIGHT
(<18" TALL)
A
A EJ
2:12A.Sub-Flr
dropped ceiling
9' - 9"
BEDROOM
W310
BEDROOM
W306
BEDROOM
W303
FAMILY
W300
MASTER
BEDROOM
E307
BEDROOM
E309
LANDING
E300
BEDROOM
E303
ASSESS CEILING HT IN
THIS AREA OVER
DOOR TO LEAVE MAX
HEIGHT, BUT ENOUGH
ROOM TO GET FLUE
ACROSS
RUN FLUE FROM MASTER FP TO
CHIMNEY MASS ON ROOF
1
A5.1
B B
UNDERFRAME CEILING TO
MATCH ROOF OF
SOUTHERN PORTION
3:12
CM SD
SD
SD
SD
SD
SD
SD CM
gfci gfcigfciE
gfci
gfci
gfcigfciFIREPLACE
APPLIANCE IS TO
APPROVED TO BE
IN SLEEPING
ROOMS
EXTERIOR OUTLET
EXTERIOR OUTLET
SD
smoke alarm at high
point in ceiling
EXTERIOR OUTLET
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND BE GFCI
gfci gfcigfcigfci OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND BE GFCI
OUTDOOR RECEPTACLES
ARE 125-VOLT, SINGLE
PHASE, 15 AND 20 AMP AND
BE GFCI
A wp
D
E
F
G
J
K
L
5" RECESSED CAN LIGHT (wet location)
5" RECESSED CAN LIGHT (sloped ceiling fixture)
5" RECESSED CAN LIGHT (directional spot)
CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT)
A 5" RECESSED CAN LIGHT
WALL MOUNTED SCONCE FIXTURE
CEILING FAN
UNDERCABINET LIGHT
H FLUORESCENT CLOSET LIGHT
BATH FAN
2x4 FLUORESCENT FIXTURE
SURFACE MOUNT
STEP LIGHT
M COVE LIGHTING (LED TAPE)
1/2 HOT DUPLEX OUTLET
NOTES:
1 PROVIDE DOOR BELL CHIME AT EACH LEVEL.
2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE
LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR
3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE
DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL
4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS
B
C
t THERMOSTAT
SD
CM
SMOKE DETECTOR
CO SENSOR/DETECTOR
SWITCH
INTERIOR LIGHTING NOTE
GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT
SECTION N1104.1 LIGHTING EQUIPMENT:
A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED
LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS.
gfci
GFCI OUTLET
PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY,
POWDER AND OUTDOORS LAUNDRY AND
DISHWASHERS ARE ON GFCI PROTECTION
ARC-FAULT CIRCUIT INTERRUPTER
AFCI protection is required on all branch circuits supplying
outlets or devices installed in dwelling unit kitchens, family
rooms, dining rooms, living rooms, parlors, libraries, dens,
bedrooms, sunrooms, recreation rooms, closets, hallways,
laundry areas, and similar rooms and areas.
OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15
AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A
COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS7/13/2017 4:01:14 PMA6.2UPPER LEVEL RCP16702655 Davos TrailPERMIT SET04-28-17Custom Duplex atVail Colorado1/4" = 1'-0"1
A3.0 UPPER LEVEL RCP AND ARCH
LIGHTING PLAN
1/4" = 1'-0"
ELECTRICAL LEGEND No. Description Date1 Revision 1- BUILDING DEPT COMMENTS7-13-17All exterior outlets to be WR
and to have Extra Duty rated
in-use covers.
01/02/18
01/02/18
06/13/17
01/02/18
06/13/17
01/02/18
06/13/17
01/02/18
07/18/17
01/02/18
07/18/17
01/02/18
06/13/17
01/02/18
06/13/17
01/02/18
06/13/17
01/02/18
06/13/17
01/02/18
06/13/17
01/02/18
01/02/18