HomeMy WebLinkAboutd2655dtr1-2655 Davos.pdf West Slope Testing & Inspection LLC Report #1
3177 Glendam Dr.
Grand Junction, CO 81504 Page 1 of 1
Phone: 970-434-6988
Cell: 970-260-2844
Inspection Report
Dates: 5-21-18 & 5-23-18
Client: H-P—Kumar (Project #17-7-344)
Project: Duplex 2655 Davos Trail
Address: 2655 Davos Trail Vail, CO
Building Permit No's: B17-0161 & B-17-0162
General Contractor: Sentry Construction
Inspection of shop fabrication or field work at job site: Field
Report: Visually inspected field welding at the plate type steel frame moment
connections on the project & field welding at steel beam to seat angles at main
level framing front side of unit A. Also inspected high strength A325 bolting at
the steel beam & column connections, as best as possible at this stage of the
construction.
The field welding & high strength A325 bolting inspected above appeared to be
in substantial conformance with the plans, and the quality requirements of the
AWS D1.1 Structural Welding Code & the AISC/RCSC Specification for high
strength bolting.
Douglas E.Young
Certification#5102224
tura Wel ' g Specia n o
Inspector/Technician: Douglas E Young turaSteel Bolti t, .eal i spector
y- led 17 eprooling ,eel,l Inspector
g, ® Douglas E Young
S , CW! 96070131