Loading...
HomeMy WebLinkAboutB17-0162_A2.0_1504018500.pdfUP UP DN DN D W DN DN UP A3.0 A3.1 2 1 3' - 9" 22' - 6" 22' - 11 1/2" 15' - 6 1/2" 13' - 5 1/2" 10' - 3 1/2" 8031' - 0" 8% 8% 8031'-0"+ 5% 8031' - 6" 2 A4.1 8030' - 0" GUEST PARKING EXTERIOR 31' - 3" 4' - 6 1/2" 1' - 5 1/2" 10' - 3 1/2" 16' - 6" 8' - 6" 8' - 0" 8034' - 6" 24' - 3" 25' - 2 1/2" 8" 1' - 2" 4' - 4" 21' - 1" 1' - 2" 1 A4.2 8034' - 3 1/4" 8032' - 1 1/8" 8034' - 6" 8031' - 0" 8032' - 0" 8030' - 9" 8031' - 3 3/16" 8032' - 10" 8032' - 11" 5' - 8" 5' - 7" 20' - 0" FD. FD. 1 4 A4.2 3 A4.1 1 A4.1 4' - 6 1/2" 18' - 5" 12' - 10" 8' - 2 1/2" 1' - 5 1/2" 8032' - 6" 2 A4.3 8" 3' - 10 1/2" R @ 6" 4 2 A4.2 3 A4.2 1 A4.3 1' - 0" 24' - 0" 1' - 0" 8' - 5 1/2" 6" 3' - 6" 1' - 0" 3' - 6" crawlspace PROVIDE VAPOR BARRIER OVER GRADE AND UP FOUNDATION WALL AT LEAST 6" AND TAPE/SEAL TO WALL. R-13 ON THE EXTERIOR WALLS OF CRAWLSPACE. R-49 IN THE FLOOR JOISTS ABOVE. (VAPOR BARRIER AGAINST THE FLOOR SHEATHING) GUEST PARKING EXTERIOR elec meter phone and cable in side wall of garage 4 A4.1 < 5'-0" INTO FRONT SETBACK 4' - 11 3/4" 8031' - 6" GARAGE W100 MECHANICAL W101 MUD ROOM W102 LAUNDRY W103 RES. ENTRY W104 COATS W105 ENTRY W106 JR. SUITE BEDROOM W107 WC W108 BATH W109 CLOSET W110 GARAGE E100 RES. ENTRY E101 MECHANICAL E102 SKI ROOM E103 2 A4.4 FD. FD. 8032' - 6" 8032' - 0" 8032' - 0" FD. FD. 8034' - 5 3/4" E100A E100B W108 W106 1 3 2 W107 W109 W110 W104 R @ 7 1/2" 3 W103 W101 W100 E103 E102 LINEN 46' - 11 1/2" 14' - 9" 5' - 9" 1' - 5 1/2" 7' - 2 1/2" 15' - 7" 1' - 5 1/2" 6' - 10" 12' - 10 1/2" 3' - 4 1/2" 7" 1' - 2 1/2" 12' - 11 1/2" 6' - 10 1/2" 6' - 1 1/2" 9' - 5" 5' - 9" 5' - 4" 7' - 1" 3' - 8" 4' - 0 1/2" 3 1/2" 6' - 6 1/2" 3' - 4 1/2" 2' - 0 1/2" 8" 3 '- 0". 4" 18' - 0" 4" 3' - 8" R @ 7 3/4" 183' - 6" 3' - 8" 4' - 1" 3' - 7" 11' - 8 1/2" 5' - 3" 19' - 3 1/2" 7' - 6" 2' - 2 1/2" 3' - 10 3/16" 130° R @ 6 1/2" 9 R @ 6" 8 R @ 6" 3 4' - 0" 2' - 0"8' - 2 3/4" 8' - 0" 3' - 0" 1' - 0" 7' - 0" 4' - 7"4' - 6 " 49' - 2 1/2" 26' - 0" 18' - 11" 1' - 2" 26' - 7" 9' - 5" 3' - 0" 11' - 0 1/2" 5' - 3" 4" 18' - 0" 4" 2' - 8" 10' - 6" 3' - 5" 5' - 0" 10' - 0" 2' - 0" planter to jog in partywall foundation 12' - 0" 1 A4.4 PARTY WALL 7" 7" 7" 4' - 1" column 3' - 2 3/4" 1' - 8 3/4" column 12' - 9" 2 1/2" 1' - 6" 1 A5.2 92% MIN. EFF. OF BOILER FOR RADIANT INFLOOR HEATING SYSTEM PROVIDE SIDE ARM FOR HOT WATER 92% MIN. EFF. OF BOILER FOR RADIANT INFLOOR HEATING SYSTEM PROVIDE SIDE ARM FOR HOT WATER 3'x3' ACCESS DOOR INTO CRAWLSPACE FLUE ROUTING FOR BOILER. (JOG FLUE ABOVE FOUNDATIN WALL) W105 8032' - 6" 8034' - 6" BOILER FLUE RADON STACK PIPING TO RISE THRU FLOOR ABOVE IN THIS LOCATION RADON STACK PIPING IN THIS LOCATION 6' - 0" STEEL TUBE DECK COLUMN ON CONC. PIER R @6 13/16" 19 PROVIDE 1 1/2"x3/4" STEEL BAR STOCK RAILING AT STAIRS WITH 4 OR MORE RISERS. TOP OF RAILING TO BE 3'-0" ABOVE THE STAIR NOSING . RAILING TO RETURN TO THE WALL OR TURN DOWN TO THE TOP OF LANDING AT TOP AND BOTTOM OF STAIR 1' - 0" 1' - 0" 1 20 min. door on self closing hinges 20 min. door on self closing hinges 1 1 11" 11" 11" 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/5/2017 3:35:36 PM A2.0 LOWER LEVEL PLAN 1670 2655 Davos Trail PERMIT SET 04-28-17 Custom Duplex at Vail Colorado 1/4" = 1'-0" 1 A1.0 LOWER LEVEL True North Project North BLOWER DOOR TEST N1102.4.1.2 (R402.4.1.2) Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Zones 1 and 2, and 3 air changes per hour in Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the building official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the building official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. No. Description Date 1 Revision 1- BUILDING DEPT COMMENTS 7-5-17 Ignition sources to be elevated min 18" above garage floor 08/29/17