HomeMy WebLinkAboutB17-0162_A3.2_1504018566.pdfA2.0 MAIN LEVEL 8047' - 0" A3.0 UPPER LEVEL 8057' - 9" Plate Height 8066' - 1" A1.0 LOWER LEVEL 8032' - 0" A1.5 Jr MASTER LVL 8034' - 6" B 0.5 GARAGE 8031' - 0" B1.7 MAIN LEVEL 8042' - 0" B2.7 UPPER LVL 8055' - 0" 2 A4.1 1 A4.2 23' - 9" 24' - 8" 4 A4.2 3 A4.1 1 A4.1 2 A4.2 3 A4.2 4 A4.1 High Plate Height (West) 8072' - 3 3/4" PARTY WALL East master bath Plate Height 8065' - 1" 8057' - 9" COUNTERFORTS REVIEW WITH STRUCTURAL CRAWLSPACE UNDER THIS PORTION 66 E305A 67 E303A 68 69 70 71 72 73 74 75 76 77 68 69 70 71 72 73 74 75 76 77 3:12 2:122:12 8056' - 6" 8056' - 0" 5 A5.1 1 A5.2 25' - 11" R308.4.3 Glazing in windows. Glazing in an individual fixed or operable panel that meets all of the following conditions shall be considered a hazardous location AND tempered glass is to used as glazing: 1. The exposed area of an individual pane is larger than 9 square feet (0.836 m2); 2. The bottom edge of the glazing is less than 18 inches (457 mm) above the floor; 3. The top edge of the glazing is more than 36 inches (914 mm) above the floor; and 4. One or more walking surfaces are within 36 inches (914 mm), measured horizontally and in a straight line, of the glazing. WINDOW NOTES: 1. ALL WINDOWS SHALL BE DOUBLE-PANED ALUM. CLAD WOOD WINDOWS UNLESS OTHERWISE NOTED. 2. U-VALUE OF .30 MAXIMUM (SEE INSULATION SUMMARY). 3. ALL WINDOWS TO RECEIVE LOW-E TREATMENT. 4. ALL SIZES SHOWN ARE NOMINAL. CONTRACTOR TO VERIFY ROUGH- OPENING SIZES WITH CHOSEN WINDOW MANUFACTURER. 5. WINDOWS MUST DISPLAY MANUFACTURER SPECS INCLUDING R-VALUES PRIOR TO COUNTY INSPECTIONS. 6. LOW AWNING WINDOWS SHALL RECEIVE MANUFATURERS' OPENING LIMITER AS REQUIREED BY BUILDING CODE 7. CONTRACTOR AND WINDOW SUPPLIER TO CONFIRM ALL LOCATIONS OF TEMPERED GLASS AND PROVIDE ACCORDINGLY. 8. ALL SLIDING AND HINGED PATIO DOORS ARE TO BE PROVIDED BY THE WINDOW MANUFACTURE. DOORS THAT ARE TALLER THAN WINDOW MANUFACTURER PRODUCES MAY BE PROVIDED BY ANOTHER MANUFACTURE, BUT FINISHES SHALL BE THE SAME AS TYPICAL. 9. ALL TRAPAZOIDE WINDOWS ARE TO BE FIELD VERIFIED FOR SIZE AND SLOPE. TRAPAZIODE WINDOWS TYPICALLY SHOULD BE THE SAME SLOPE AS THE ROOF CEILING ABOVE. 10. COORDINATE THE TRANSOM WINDOW SIZES SO THAT THE OVERALL WIDTH MATCHES THAT OF DOORS BELOW 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/5/2017 3:35:52 PM A3.2 NORTH ELEVATION 1670 2655 Davos Trail PERMIT SET 04-28-17 Custom Duplex at Vail Colorado 1/4" = 1'-0" 1 North Elevation Window Schedule Mark Family Width Height Level Comments 60 Window-Picture 5' - 0" 5' - 0" B2.7 UPPER LVL 61 Window-Picture 3' - 0" 5' - 0" B2.7 UPPER LVL 62 Window-Casement 3' - 0" 5' - 0" B2.7 UPPER LVL 63 Window_Trapezoide 5' - 0" 4' - 0" B2.7 UPPER LVL 64 Window_Trapezoide 5' - 0" 3' - 2" B2.7 UPPER LVL 65 Window-Picture 5' - 0" 5' - 0" B2.7 UPPER LVL tempered 66 Window-Casement 2' - 6" 5' - 0" B2.7 UPPER LVL tempered 67 Window-Awning 4' - 0" 2' - 6" B2.7 UPPER LVL 68 Window-Awning 3' - 0" 2' - 0" B2.7 UPPER LVL 69 Window-Awning 2' - 6" 2' - 0" B2.7 UPPER LVL 70 Window-Casement 2' - 6" 5' - 0" B2.7 UPPER LVL tempered 71 Window-Picture 4' - 6" 7' - 0" B2.7 UPPER LVL 72 Window-Casement 2' - 6" 5' - 0" B2.7 UPPER LVL 73 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL 74 Window-Picture 4' - 6" 4' - 6" A3.0 UPPER LEVEL 75 Window-Casement 3' - 0" 5' - 0" A3.0 UPPER LEVEL 76 Window-Picture 4' - 6" 5' - 0" A3.0 UPPER LEVEL tempered 77 Window-Casement 3' - 0" 5' - 0" A3.0 UPPER LEVEL tempered Window Schedule Mark Family Width Height Level Comments 32 Window-Awning 5' - 0" 2' - 0" B1.7 MAIN LEVEL 33 Window-Picture 5' - 6" 3' - 6" B1.7 MAIN LEVEL 34 Window-Picture 2' - 0" 6' - 0" B1.7 MAIN LEVEL tempered 35 Window-Awning 3' - 0" 2' - 6" B1.7 MAIN LEVEL 36 Window-Awning 3' - 0" 2' - 6" A2.0 MAIN LEVEL 37 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL 38 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL 39 Window-Casement 3' - 0" 4' - 6" A3.0 UPPER LEVEL 40 Window-Picture 4' - 0" 4' - 6" A3.0 UPPER LEVEL tempered 41 Window_Trapezoide 4' - 0" 3' - 0" A3.0 UPPER LEVEL tempered 42 Window_Trapezoide 4' - 0" 4' - 0" A3.0 UPPER LEVEL 43 Window-Awning 3' - 0" 2' - 0" A3.0 UPPER LEVEL 44 Window-Picture 5' - 6" 7' - 0" A3.0 UPPER LEVEL tempered 45 Window-Awning 3' - 0" 2' - 0" A3.0 UPPER LEVEL 46 Window-Casement 3' - 0" 5' - 0" A3.0 UPPER LEVEL 47 Window-Picture 5' - 6" 7' - 0" A3.0 UPPER LEVEL 48 Window-Picture 3' - 0" 3' - 0" B2.7 UPPER LVL 49 Window-Picture 2' - 0" 4' - 0" B2.7 UPPER LVL tempered 50 Window_Trapezoide 3' - 0" 2' - 6" A3.0 UPPER LEVEL 51 Window_Trapezoide 4' - 0" 3' - 4" A3.0 UPPER LEVEL 52 Window-Picture 4' - 0" 5' - 0" B2.7 UPPER LVL 53 Window-Picture 3' - 6" 4' - 0" B2.7 UPPER LVL tempered 54 Window-Casement 3' - 6" 5' - 0" B2.7 UPPER LVL 55 Window-Picture 2' - 0" 4' - 0" B2.7 UPPER LVL 56 Window-Casement 2' - 0" 5' - 0" B2.7 UPPER LVL 57 Window-Picture 3' - 0" 5' - 0" B2.7 UPPER LVL 58 Window-Casement 3' - 0" 5' - 0" B2.7 UPPER LVL 59 Window-Picture 5' - 0" 5' - 0" B2.7 UPPER LVL Window Schedule Mark Family Width Height Level Comments 1 Window-Casement 3' - 0" 6' - 0" A1.5 Jr MASTER LVL tempered 2 Window-Awning 3' - 0" 2' - 0" A1.5 Jr MASTER LVL 3 Window-Picture 6' - 0" 6' - 0" A1.5 Jr MASTER LVL 4 Window-Casement 3' - 6" 5' - 0" A2.0 MAIN LEVEL tempered 5 Window-Picture 5' - 0" 5' - 0" A2.0 MAIN LEVEL tempered 6 Window-Casement 3' - 0" 6' - 0" A2.0 MAIN LEVEL tempered 7 Window-Awning 3' - 0" 2' - 0" A2.0 MAIN LEVEL 8 Window_Trapezoide 4' - 0" 1' - 3" A2.0 MAIN LEVEL 9 Window_Trapezoide 4' - 0" 2' - 3" A2.0 MAIN LEVEL 10 Window_Trapezoide 8' - 0" 3' - 3" A2.0 MAIN LEVEL 11 Window-Picture 4' - 0" 5' - 0" A2.0 MAIN LEVEL 12 Window-Picture 3' - 0" 5' - 0" B2.7 UPPER LVL 13 Window-Picture 4' - 0" 6' - 0" A2.0 MAIN LEVEL 14 Window-Awning 4' - 0" 2' - 0" A2.0 MAIN LEVEL 15 Window-Picture 3' - 0" 6' - 0" A2.0 MAIN LEVEL 16 Window-Awning 3' - 0" 2' - 0" A2.0 MAIN LEVEL 17 Window-Picture 6' - 0" 8' - 0" A1.9 MASTER LVL tempered 18 Window-Picture 3' - 0" 8' - 0" A1.9 MASTER LVL tempered 19 Window-Awning 3' - 0" 2' - 3" A1.9 MASTER LVL 20 Window-Casement 3' - 0" 5' - 0" A1.9 MASTER LVL tempered 21 Window-Awning 3' - 0" 2' - 6" A1.9 MASTER LVL 22 Window-Picture 6' - 0" 2' - 3" A1.9 MASTER LVL 23 Window-Picture 4' - 0" 4' - 6" A2.0 MAIN LEVEL tempered 24 Window-Awning 4' - 0" 2' - 6" B1.7 MAIN LEVEL tempered 25 Window-Picture 4' - 0" 7' - 0" B1.7 MAIN LEVEL tempered 26 Window-Picture 3' - 0" 7' - 0" B1.7 MAIN LEVEL tempered 31 Window-Picture 5' - 0" 7' - 0" B1.7 MAIN LEVEL 12" = 1'-0" WINDOW SCHEDULE NOTES No. Description Date 1 Revision 1- BUILDING DEPT COMMENTS 7-5-17 1 1 1 added location of tempered glazing 08/29/17