HomeMy WebLinkAboutB17-0162_A5.1_1504018565.pdfR-19 (MIN) BLOWN-IN INSULATION TO FILL 2X STUD FURRING WALL CAVITY. GYPSUM WALL BOARD HELD UP FROM SLAB 3/8" TREATED WOOD BOTTOM PLATE SEALANT UNDER PLATE FOR CAPILLARY BREAK. (R-10) UNDER-SLAB INSULATION HEATED CONCRETE SLAB (IN-FLOOR RADIANT HEATING SYSTEM) GRANULAR FILL - INCLUDE SOIL-GAS VENTILATION SYSTEM REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION/FOOTING DESIGN AND REINFORCEMENT (R-5) 3/4" RIGID INSULATION FOR THERMAL BREAK SLOPED 4" PERFORATED DRAIN PIPE. ALL FOUNDATION WALLS INCLUDING INTERIOR WALLS. RE: SOILS REPORT COARSE GRANULAR FILL FILTER FABRIC DAMPROOFING OR W.P. MEMBRANE FOR CAPILLARY BREAK FREE-DRAINING BACKFILL (R-10) 2-3/8" DRAIN & DRY" DRAINAGE BOARD OVER WATERPROOFING (FROM FOOTING TO 8" BELOW FINISHED GRADE) 5/8" TYPE "X" GYPSUM WALL BOARD SLOPED 4" SOLID DRAIN FROM GUTTER & DOWNSPOUT UNDER- DRAIN SYSTEM. (MAY BE LOCATED HIGHER, BUT AT LEAST 4'-0" BELOW FINISHED GRADE NEAR BUILDING) ALTERNATE SYSTEM: COMPOSITE DRAINAGE BOARD WITH FILTER FABRIC EXTEND FROM 8" BELOW GRADE TO FOOTING OVER 2" RIGID INLSULATION (TO A DEPTH OF 4'-0" BELOW GRADE) OVER WATERPROOFING. INTERIOR SPACE BASE TRIM ADDITIONAL 4" PERFORATED DRAIN PIPE AT 10'-0" VERTICAL SPACING AT ALL UPHILL FOUNDATION WALLS IN EXCESS OF 15' IN HT WATERPROOF MEMBRANE TO EXTEND FROM FOOTING TO 6" ABOVE FINISHED GRADE 1 A1.5 Jr MASTER LVL 8034' - 6" A1.9 MASTER LVL 8045' - 10" B 0.5 GARAGE 8031' - 0" B1.7 MAIN LEVEL 8042' - 0" B2.7 UPPER LVL 8055' - 0" PARTY WALL GA FILE NO. WP 3810 BASE LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD APPLIED AT RIGHT ANGLES TO 2X6 WOOD STUDS AT 24" O.C. WITH 6d COATED NAILS, 1 7/8" LONG. 1/4" HEADS, 16" O.C. FACE LAYER: 5/8" SOUNDBREAK XP APPLIED AT RIGHT ANGLES TO STUDS OVER BASE LAYER AND TOP AND BTM PLATES WITH 8d COATED NAILS, 2 3/8" LONG, 0.099" SHANK, 9/32" HEADS, 8" O.C. JOINTS OFFSET 24" FROM BASE LAYER JOINTS. INNER LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD WITH 6d COATED NAILS, 1 7/8" LONG, .0915 SHANK, 1/4" HEADS, 8" O.C. JOINTS IN INNER LAYER NEED NOT BE TAPED. SECOND WALL DUPLICATED OF FIRST WALL AND SEPARATED BY 1 3/4" SPACE. WALLS ARE INDEPENDANTLY LOADED. WALLS TO RECIEVE 5 1/2" BLOWN-IN INSULATION. (LOAD BEARING) LANDINGE300 MASTER BEDROOM W205 LIVING E200 3" 7" 7" 1 3/4" JR. SUITE BEDROOM W107 GARAGE E100 4' - 0" 5/8" GWB APPLIED TO THE UNDER SIDE OF ROOF SHEATHING FOR A DISTANCE OF 4'-0" FROM PARTY WALL AT LOCATION WHERE THE ROOF PLANES ARE LESS THAN 30" PROVIDE 5/8" TYPE 'X' GYPSUM WALL BOARD AT RIM JOIST SO THAT THE WALL ASSEMBLY HAS A TOTAL OF 2 LAYERS FOR HEIGHT OF WALL PROVIDE 5/8" TYPE 'X' GYPSUM WALL BOARD AT RIM JOIST SO THAT THE WALL ASSEMBLY HAS A TOTAL OF 2 LAYERS FOR HEIGHT OF WALL A3.0 UPPER LEVEL 8057' - 9" A1.9 MASTER LVL 8045' - 10" East-West High Plate Height 8070' - 6" 1' - 2" OVERHANG 1' - 6" BLOCK BCI WEB AT BEARING POINTS 1 1/2" SLOPED BLOCKING 'D' SHAPED DRIP FLASHING (LEG LONG ENOUGH TO COVER 2X6 FASCIA) WITH DRIP HEM AT BOTTOM 2x12 FASCIA ALUM. SOFFIT VENT WITH BUG SCREEN. PROVIDE AT BOTH AT LOW SIDE OF ROOF AND AT HIGH TL ASPHALT SHINGLES ON FULL COVERAGE WATERPROOF MEMBRANE ON ROOF SHEATHING ON 12 1/2" BCI/LVL ROOF RAFTERS WITH BLOWN-IN BATT R-59.22 INSULATION BETWEEN RAFTERS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON CEILING DASHED LINE REPRESENTS VAPOR RETARDER LOCATION HEAD FLASHING AT ALL WINDOW AND DOOR HEADS VERTICAL WOOD SIDING ON THERMAL AND AIR INFILTRATION BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON WALL VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS.SHIM SPACE 1" SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS see strcut for min. 11" 1' - 0" 2" WATERPROOF MEMBRANE TO TURN DOWN AND OVERLAP FASCIA WATER PROOF MEMBRANE FROM DECK TO TURN UP WALL MINIMUM OF 2'-0". EXTEND UNDER DOOR THRESHOLDS, LAP DOOR THRESHOLD VYCOR OVER DRAINAGE MEDIUM IS TO STOP 3" FROM EDGE. PROVIDE ROPE WICKS AT 2'-0" O.C. ALONG EDGE EDGE FLASHING DASHED LINE REPRESENTS VAPOR RETARDER LOCATION 5/8" TYPE 'X' GYPSUM WALL BOARD VYCORE TAPE NAILING FLANGE AT TOP OF WINDOW SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS STEP DOWN FROM INTERIOR TO EXTERIOR 1/2" TO 1" BOTTOM OF WALL FLASHING 2x14 DECK EDGE 1x6 T&G SOFFIT ALUM CLAD WOOD WINDOW 4" MAXIMUM SPACING TO BTM RAIL VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS. 1x6 T&G SOFFIT STONE VENEER ON DRAINAGE MEDIUM SYSTEM ON THERMAL AND AIR INFILTRATION BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON WALL 8043' - 6" 8043' - 7" ENTRY W106 ENTRY W106 FAMILY W300 FAMILY W300 LANDINGW204 R-58 BLOWN-IN BATTS INSULATION 3" 3" 12' - 9" METAL PANEL SYSTEM WITH CONCEALED FASTENERS 3" 9 1/4" 8068' - 1" 9' - 8" 3/4" 9 1/4" 2 1/4" 1' - 2 3/4" 11' - 11" MC 10x8.4 STEEL CHANNEL AT EDGE OF DECKS 3" SPACER AT GUARD CONNECTION CORRUGATED AIR BAFFLE 1x6 T&G SOFFIT 1 1/2" AIR GAP LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30 SPRAY FOAM INSUALTION AND BATT INSULATION BETWEEN JOISTS. East Partywall Plate Height 8063' - 1" PARTY WALL 5/8" GWB APPLIED TO THE UNDER SIDE OF ROOF SHEATHING FOR A DISTANCE OF 4'-0" FROM PARTY WALL AT LOCATION WHERE THE ROOF PLANES ARE LESS THAN 30" PROVIDE 5/8" TYPE 'X' GWB TO THE UNDERSIDE OF THE OVERHANG AND UNDER FASCIA TO CREATE A FIRE PROTECTED OVERHANG SUBSTITUTE THE 1/2" EXTERIOR PLYWOOD WALL SHEATHING WITH EXTERIOR GWB FOR PORTION OF WALL THAT FACES WEST LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30+ BLOWN IN BATTS INSULATION BETWEEN JOISTS. BOTTOM OF WALL FLASHING 'D' SHAPED DRIP FLASHING (LEG LONG ENOUGH TO COVER 2X6 FASCIA) WITH DRIP HEM AT BOTTOM WATERPROOF MEMBRANE TO TURN DOWN AND OVERLAP FASCIA 1 1/2" GA FILE NO. WP 3810 BASE LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD APPLIED AT RIGHT ANGLES TO 2X6 WOOD STUDS AT 24" O.C. WITH 6d COATED NAILS, 1 7/8" LONG. 1/4" HEADS, 16" O.C. FACE LAYER: 5/8" SOUNDBREAK XP APPLIED AT RIGHT ANGLES TO STUDS OVER BASE LAYER AND TOP AND BTM PLATES WITH 8d COATED NAILS, 2 3/8" LONG, 0.099" SHANK, 9/32" HEADS, 8" O.C. JOINTS OFFSET 24" FROM BASE LAYER JOINTS. INNER LAYER: 5/8" TYPE 'X' GYPSUM WALL BOARD WITH 6d COATED NAILS, 1 7/8" LONG, .0915 SHANK, 1/4" HEADS, 8" O.C. JOINTS IN INNER LAYER NEED NOT BE TAPED. SECOND WALL DUPLICATED OF FIRST WALL AND SEPARATED BY 1 3/4" SPACE. WALLS ARE INDEPENDANTLY LOADED. WALLS TO RECIEVE 5 1/2" BLOWN-IN INSULATION. (LOAD BEARING) 3" BOTH WALLS ARE INDEPNDANTLY BEARING AND THE ROOF AND ROOF OVERHANG IS COVERED IN 5/8" TYPE 'X' GWB PROVIDING THE FIRE SEPARATION PROTECTION FROM EACH UNIT SEE STRUCTURAL DETAIL FOR BLOCKING AND ANCHORAGE PROVIDE 5/8" TYPE 'X' GYPSUM WALL BOARD AT RIM JOIST SO THAT THE WALL ASSEMBLY HAS A TOTAL OF 2 LAYERS FOR HEIGHT OF WALL SPRAY FOAM INSUALTION ON UNDERSIDE OF STRUCTURAL ROOF SHEATHING/GWB (R-30 AT 4.5") AND 10" FIBERGLASS BATT INSUALTION 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/5/2017 3:36:00 PM A5.1 DETAILS 1670 2655 Davos Trail PERMIT SET 04-28-17 Custom Duplex at Vail Colorado 1" = 1'-0" 3 TYPICAL FOUNDATION DETAIL 1" = 1'-0" 4 PARTY WALL SECTION 1 1/2" = 1'-0" 5 WALL SECTION AT WEST UNIT, SOUTH WALL 1" = 1'-0" 1 WALL SECTION AT PARTYWALL WITH ROOF OVERHANG No. Description Date 1 Revision 1- BUILDING DEPT COMMENTS 7-5-17 1 1 1 08/29/17