Loading...
HomeMy WebLinkAboutB17-0162_A5.2_1504018567.pdfA2.0 MAIN LEVEL 8047' - 0" 1 1/2" 'D' SHAPED DRIP FLASHING (LEG LONG ENOUGH TO COVER 2X6 FASCIA) WITH DRIP HEM AT BOTTOM 2x12 FASCIA TL ASPHALT SHINGLES ON FULL COVERAGE WATERPROOF MEMBRANE ON ROOF SHEATHING ON 14" BCI/LVL ROOF RAFTERS, CORREGATED AIR BAFFEL, WITH BLOWN-IN BATT R-52.22 INSULATION BETWEEN RAFTERS.MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON CEILING DASHED LINE REPRESENTS VAPOR RETARDER LOCATION VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS. SEAL/FOAM THE PERIMETER OF ALL PENATRATIONS WATERPROOF MEMBRANE TO TURN DOWN AND OVERLAP FASCIA ALL TRAPAZOIDE WINDOWS ARE TO BE FIELD VERIFIED FOR SIZE AND SLOPE. TRAPAZIODE WINDOWS TYPICALLY SHOULD BE THE SAME SLOPE AS THE ROOF/CEILING ABOVE. COORDINATE THE TRANSOM WINDOW SIZES SO THAT THE OVERALL WIDTH MATCHES THAT OF DOORS BELOW PLACE 3/4" RIGID INSULATION IN PLANCE OF 5/8" GYPSUM WALL BOARD UNDER TRIM AT LOCATION BETWEEN WINDOWS WITH STEEL HEADER HORIZONTAL METAL PANEL CLOSURE PIECE BETWEEN WINDOWS 1' - 0" 2" LARGE RECTILINEAR STONE TILE ON MORTAR ON 3" CONCRETE SLAB WITH RADIANT HEATING SYSTEM TUBING ON J DRAIN 1000 DRAINAGE MEDIUM/PROTECTION (OR SIMILAR) ON 2 LAYERS OF WATERPROOF MEMBRANE ON 3/4" SHEATHING ON SLOPING TOP CUT LVLS. R-30 SPRAY FOAM INSUALTION AND BATT INSULATION BETWEEN JOISTS. DRAINAGE MEDIUM IS TO STOP 3" FROM EDGE. PROVIDE ROPE WICKS AT 2'-0" O.C. ALONG EDGE EDGE FLASHING DASHED LINE REPRESENTS VAPOR RETARDER LOCATION BOTTOM OF WALL FLASHING AT LOCATIONS WITHOUT DOOR MC 10X8.4 STEEL CHANNEL AT EDGE OF DECKS 1x6 T&G SOFFIT 3" WATERPROOF MEMBRANE FROM DECK TO TURN UP WALL MINIMUM OF 2'-0". EXTEND UNDER DOOR THRESHOLDS, LAP DOOR THRESHOLD VYCOR OVER TRESHOLD, SET IN SEALANT 5' - 6" 3" 3' - 11" STONE VENEER ON DRAINAGE MEDIUM SYSTEM ON THERMAL AND AIR INFILTRATION BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON WALL 3" STONE WALL CAP, SLOPE TO EXTERIOR 4' - 6 1/2" 1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON WALL HORIZONTAL WOOD SIDING ON THERMAL AND AIR INFILTRATION BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH BLOWN-IN BATTS R-23 INSUALTION BETWEEN STUDS. MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON WALL WEATHERSTRIPPING AT HEAD AND JAMBS OF GARAGE DOOR SEMI-TRANSLUCENT GLASS PANELS IN ALUM. OVERHEAD DOOR (REVIEW BELT LIFT FOR QUIETER OPERATION) STOP INSULATION TO TEMPER THE VOID UND THE HEATED DECK 3" SLAB 2 1/4". minimum see struct for SPACER AT GUARD CONNECTION W12x26 INSULATE EAVES AT LOCATIONS WITH STEEL BEAMS IN ROOF PLANE 1 1 DRAINAGE MEDIUM IS TO STOP 3" FROM EDGE. PROVIDE ROPE WICKS AT 2'-0" O.C. ALONG EDGE EDGE FLASHING MC 10X8.4 STEEL CHANNEL AT EDGE OF DECKS SPACER AT GUARD CONNECTION 3 3/4" 2" 3' - 0 1/4" 2 7/8" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 2 7/8" 2" 1 3/4"IPEA TOP CAP WITH SLOPED TOP 2" TUBE STEEL, PAINTED (BLACK) 1 1/2"x3/8" STEEL BAR STOCK 3" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 3 3/4" 3/8"3 3/4" 3/8" 2" TUBE STEEL, PAINTED (BLACK) 1 1/2"x3/8" STEEL BAR STOCK 3/4" 2 1/4" 3 3/4" 3/8" 1 3/4" 2"x3/8" STEEL BAR STOCK 2"x3/4" STEEL BAR STOCK GRASPABLE RAILING EASE ALL EDGES SO THAT THEY ARE SMOOTH 3' - 0 1/2" INTERIOR GUARD 3 7/8" 3' - 0 1/2" INTERIOR STAIR RAILING 3 11/16" 11" 1' - 0" 2' - 5 5/8" 2"3/8" 3 3/4 "3 3/4"3 3/4"3 3/4"3 3/4"3 3/4" 1 3/4"3/4" 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/13/2017 4:01:10 PM A5.2 DETAILS 1670 2655 Davos Trail PERMIT SET 04-28-17 Custom Duplex at Vail Colorado 1 1/2" = 1'-0" 1 WALL SECTION AT WEST UNIT, LIVING ROOM ROOF AND DECK, SOUTH WALL No. Description Date 1 Revision 1- BUILDING DEPT COMMENTS 7-13-17 1" = 1'-0" 2 EXTERIOR GUARD DETAIL INTERIOR RAILS AND GUARD DETAIL ARE SIMILAR 1 1" = 1'-0" 3 INTERIOR GUARD AND RAILING 08/29/17