Loading...
HomeMy WebLinkAboutB17-0162_A6.0_1504018570.pdfREF. DW W D DW 2 A4.1 1 A4.2 4 A4.2 3 A4.1 1 A4.1 2 A4.3 2 A4.2 3 A4.2 1 A4.3 4 A4.1 2 A4.4 1 A4.4 PARTY WALL crawlspace PROVIDE VAPOR BARRIER OVER GRADE AND UP FOUNDATION WALL AT LEAST 6" AND TAPE/SEAL TO WALL. R-13 ON THE EXTERIOR WALLS OF CRAWLSPACE. R-49 IN THE FLOOR JOISTS ABOVE. (VAPOR BARRIER AGAINST THE FLOOR SHEATHING) SD CM D A A A A D SD TO LIGHTS ON LANDING AND SWITCH ABOVE D L L L L A.Sub-Flr dropped ceiling 10' - 7" A.Sub-Flr dropped ceiling 11' - 7" A.Sub-Flr dropped ceiling 10' - 7" A.Sub-Flr dropped ceiling 9' - 7" A.Sub-Flr dropped ceiling 9' - 1" ceiling at btm of structure above 10'-1" E A D D D G G G J t K K K K K J J E E E A wp A wp A wp A A A A D D D D TO SCONCE LIGHT, LANDING RECESSED AND SWITCH ABOVE K K K K K K D KEYLESS FIXTURE IN CRAWL 3'x3' ACCESS DOOR INTO CRAWLSPACE L L L L L TO LANDING STEP LIGHTS AND ENTRY LIGHTS ABOVE gfci gfci SD CM SD CM gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci gfci GFCI OUTLET GFCI OUTLET PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, POWDER, MECHANICAL ROOMS, GARAGES AND OUTDOORS LAUNDRY AND DISHWASHERS ARE ON GFCI PROTECTION gfci gfci gfci PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, POWDER, MECHANICAL ROOMS, GARAGES AND OUTDOORS LAUNDRY AND DISHWASHERS ARE ON GFCI PROTECTION gfci gfci gfci A wp D E F G J K L 5" RECESSED CAN LIGHT (wet location) 5" RECESSED CAN LIGHT (sloped ceiling fixture) 5" RECESSED CAN LIGHT (directional spot) CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT) A 5" RECESSED CAN LIGHT WALL MOUNTED SCONCE FIXTURE CEILING FAN UNDERCABINET LIGHT H FLUORESCENT CLOSET LIGHT BATH FAN 2x4 FLUORESCENT FIXTURE SURFACE MOUNT STEP LIGHT M COVE LIGHTING (LED TAPE) 1/2 HOT DUPLEX OUTLET NOTES: 1 PROVIDE DOOR BELL CHIME AT EACH LEVEL. 2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR 3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL 4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS B C t THERMOSTAT SD CM SMOKE DETECTOR CO SENSOR/DETECTOR SWITCH INTERIOR LIGHTING NOTE GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT SECTION N1104.1 LIGHTING EQUIPMENT: A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. gfci GFCI OUTLET PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, POWDER, MECH ROOMS GARAGES AND OUTDOORS LAUNDRY AND DISHWASHERS ARE ON GFCI PROTECTION ARC-FAULT CIRCUIT INTERRUPTER AFCI protection is required on all branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, and similar rooms and areas. OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/19/2017 3:26:40 PM A6.0 LOWER LEVEL RCP 1670 2655 Davos Trail PERMIT SET 04-28-17 Custom Duplex at Vail Colorado 1/4" = 1'-0" 1 A1.0 LOWER LEVEL RCP AND ARCH LIGHTING PLAN 1/4" = 1'-0" ELECTRICAL LEGEND No. Description Date 1 Revision 1- BUILDING DEPT COMMENTS 7-13-17 08/29/17