Loading...
HomeMy WebLinkAboutB17-0162_A6.2_1504018569.pdf2 A4.1 1 A4.2 3 A4.1 1 A4.1 2 A4.3 2 A4.2 3 A4.2 1 A4.3 4 A4.1 2 A4.4 1 A4.4 PARTY WALL 5 A5.1 1 A5.2 F SD CM B B B B B B D J t B B TO BELOW B B B B J J F F F B B B B D B B B B B B B B A wp E A E E E E A wp A wp A t F B B A.Sub-Flr dropped ceiling 9' - 9" A.Sub-Flr dropped ceiling 9' - 9" 3:12 3:12 2:12 2:12 3:12 2:12 3:12 3:12 3:12 A.Sub-Flr dropped ceiling 8' - 4" A.Sub-Flr dropped ceiling 8' - 4" A.Sub-Flr dropped ceiling 8' - 4" A.Sub-Flr dropped ceiling 8' - 4" A.Sub-Flr dropped ceiling 8' - 4" 8070' - 6" top plate 8066' - 1" top plate 8066' - 1" top plate 8066' - 1" top plate 8065' - 1" top plate 8072' - 3 3/4" top plate 8069' - 10" top plate 8067' - 10" top plate 8063' - 1" top plate 2:12 2:12 8070' - 6" top plate 8070' - 6" top plate D TO SCONCE AND SWITCH BELOW A.Sub-Flr dropped ceiling 9' - 9" F B B B B B D A C C FIREPLACE D D J J J E E A wp F B B B B D E E A wp B B HOT TUB DISCONNECT OFFSET RADON VENT PIPE/STACK A.Sub-Flr dropped ceiling 10' - 1" A.Sub-Flr dropped ceiling 10' - 1" A wp A wp A wp A wp E E TO STEP LIGHTS TO 5 LANDSCAPE LIGHT (<18" TALL) A A E J 2:12 A.Sub-Flr dropped ceiling 9' - 9" BEDROOM W310 BEDROOM W306 BEDROOM W303 FAMILY W300 MASTER BEDROOM E307 BEDROOM E309 LANDING E300 BEDROOM E303 ASSESS CEILING HT IN THIS AREA OVER DOOR TO LEAVE MAX HEIGHT, BUT ENOUGH ROOM TO GET FLUE ACROSS RUN FLUE FROM MASTER FP TO CHIMNEY MASS ON ROOF 1 A5.1 B B UNDERFRAME CEILING TO MATCH ROOF OF SOUTHERN PORTION 3:12 CM SD SD SD SD SD SD SD CM gfci gfci gfci E gfci gfci gfci gfci FIREPLACE APPLIANCE IS TO APPROVED TO BE IN SLEEPING ROOMS EXTERIOR OUTLET EXTERIOR OUTLET SD smoke alarm at high point in ceiling EXTERIOR OUTLET OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND BE GFCI gfci gfci gfci gfci OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND BE GFCI OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND BE GFCI A wp D E F G J K L 5" RECESSED CAN LIGHT (wet location) 5" RECESSED CAN LIGHT (sloped ceiling fixture) 5" RECESSED CAN LIGHT (directional spot) CEILING MOUNTED FIXTURE (CHANDELIER, PENDANT OR SURFACE MOUNT) A 5" RECESSED CAN LIGHT WALL MOUNTED SCONCE FIXTURE CEILING FAN UNDERCABINET LIGHT H FLUORESCENT CLOSET LIGHT BATH FAN 2x4 FLUORESCENT FIXTURE SURFACE MOUNT STEP LIGHT M COVE LIGHTING (LED TAPE) 1/2 HOT DUPLEX OUTLET NOTES: 1 PROVIDE DOOR BELL CHIME AT EACH LEVEL. 2 PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPE LOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR 3 ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL 4 ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS B C t THERMOSTAT SD CM SMOKE DETECTOR CO SENSOR/DETECTOR SWITCH INTERIOR LIGHTING NOTE GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENT SECTION N1104.1 LIGHTING EQUIPMENT: A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. gfci GFCI OUTLET PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, POWDER AND OUTDOORS LAUNDRY AND DISHWASHERS ARE ON GFCI PROTECTION ARC-FAULT CIRCUIT INTERRUPTER AFCI protection is required on all branch circuits supplying outlets or devices installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sunrooms, recreation rooms, closets, hallways, laundry areas, and similar rooms and areas. OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICE PO Box 1587, Eagle, CO 81631 www.martinmanleyarchitects.com Project number Date REVISIONS 7/13/2017 4:01:14 PM A6.2 UPPER LEVEL RCP 1670 2655 Davos Trail PERMIT SET 04-28-17 Custom Duplex at Vail Colorado 1/4" = 1'-0" 1 A3.0 UPPER LEVEL RCP AND ARCH LIGHTING PLAN 1/4" = 1'-0" ELECTRICAL LEGEND No. Description Date 1 Revision 1- BUILDING DEPT COMMENTS 7-13-17 08/29/17