Loading...
HomeMy WebLinkAboutB17-0162_REV1 - approved documents_1514911407.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspection Line: 970.479.2149 Construction B17-0162 / Revision 001 Issued: 01/02/2018 TOWN OF VAIL Property Information Address: 2655 DAVOS TRL ( 210314203027 ) Unit #: Parcel Number: 210314203027 Legal Description: Subdivision: VAIL RIDGE Block: B Lot: 18 Contacts Contact Type: Applicant Full Name: Mike Young Address: PO Box 480 1800 Beard Creek Trail Edwards, CO 81632 Phone: 9703762020 Contact Type: Property Owner Full Name: SENTRY CONSTRUCTION INC Address: Phone: None Contractor Contractor Type: General Company: Sentry Construction Inc State License #: Phone: 970-376-2020 Project Information Project Name: Sentry Construction Residence 2016 Project Description: REV1 - Infloor heat throughout with use of high efficiency boiler (Duplex secondary/east side) Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$3,879.75 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$2,521.84 Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$12,516.00 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$400.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$100.00 Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$900.00 Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$225.00 Account #: 111-0000.31127.00 - Recreation Fee Fee Amount:$510.90 Account #: 001-0000.31111.00 - Revision Fee Fee Amount:$220.00 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00 Total Paid:$21,288.49 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. TOWN OF® Department of Community Development 75 South Frontage Road Vail, CO 81657 Tel: 970.479.2139 www.vailgov.com TRANSMITTAL FORM Use this form when submitting additional information, changes& inspectionreportsfor building permits. This form is also used for requesting a revision to building permits. A two hour minimum building review fee of$11Owill be charged upon reissuance ofthe permit. Submit this fonn only to: cdev_submittal@vailgov.com. Deliver paper plans to CommunityDevelop- ment or upload your revised/corrected plans to the appropriate projectin ProjectDox,when requested. IApplication/Pennit#(s) infonnation applies to: _ ......B___,/_]t---.....Oc.......-. 1._ ·0......_-=b--=- ~...... D'-' O"'--'-/_I{ )Revisions ( ) Response to Correction Letter _attached copy of correction letterI()Deferred Submittal ( ) Other_ _ _ _ _ _ _ _ _ _ _ fPr~~~tStr~t Addr~~:--·· .,. ...... .,...... , .. - .. -- -· . --···-··· ..... ... ; ---· .· ---~ -. ···- - .· -......., .... . ... . ··-"··-·~-,.- ..... .. · .. _i d.C.55 Dc.,y o J ±cc.;I Ve-;/ _EftS"L i DescriptionofTransmittal/ListofChanges,ltemsAttached, ; Indicatechanged plan pages: I(Number) (Street) (Suite#) j- - - - - - - - - - - - - - - - - - - j Building/Complex Name: Do.vo~ Dvple¥ ! I. l\F/0or h4o..t- +hc~k.ov± \A./,·+h 1--·-..-~-·-~..--·-·.....___________. ·---..-·~·-i vse.s ~ of b.36 e.fP. Bo /w!Applicant lnfonnation 1(architect, contractor, owner/owner's rep) IContact Name: t1 i11'e . l(oV f\!fj !Address: Po Doz< <...[<go : r l l C.,... C:,,.{/ ':::> 1 (use additional sheet ifnecessary): City C p\e(e ..ll::l S State: ~ Zip:O l.R ..JO'\ lContact Name: M ,·Ke Yov"c;-r-------·------------~c, .Building Permits:iContact Phone: J 70 - 3 7C. - .2.0 2 .0 :Revised ADDITIONALValuations (Labor & Materials)! M · v 11 2 20 = ' ·(DO NOT include original valuation); Contact E-Mail: r\lne"fQVl\ 3 ~0~ ~ l)') o.e-.G O tl7 . · . Building: $_ _ _ _ _ _ _ _ _ I herebyacknowledgethat I have read this application, filled out in full the information required, completedan accurate plot plan, and statethat all the information as required is correct. I agreeto comply with the information and plot plan, to complywith all Town ordinances and state laws, and to buildthis structure according to the town's zoning and subdivision codes, design reviewap- proved, International Building and Residential Codes and other ordinances of the Town applicable the Plumbing: Electrical: Mechanical: Total: $ $ $ $ :x'--~~~~~~~~~~~~iOwner/ , - - - - - ·------ · - - - - - · - - - ·-·---'j Date Received:RECEIVEDI J OCT2 6 2017 Town of Vail 21-Apr-2017 ·O TnangleTube S tainless Steel Fire Tube · Heat Exchanger 95°/o AFUE · Low Pressure D ro p · . Proven Performance · 2" to 4 " Venting · '---" MultipleTermination Options · Low NOx - 20 1 2 SCAQMD Certified · 5 Models from 6 0 to 3 9 9 MBH · 2 Year Control & Blower W arra nty · Featuring TriMax controlwith: · 6 0 Second Set-Up · Integrated Cascad e ·Tw o R eset C urves/S et Points · Control of 4 Circulators I prestige - Leader in Contractor Friendl~ Features 4t TriMaxControl 60 Second Set-Up Choose from 6 standard applications to set up the boiler in 60 seconds or less. · Finned Tube Baseboard · High Mass Radiant · Cast Iron Baseboard · Low Mass Radiant ·Radiators · Fancoil Integrated Cascade Joins up to 6 boilers: Master boiler automatically recognizes linked boilers: Meets simultaneous DHW & Space Heating calls: Full Parallel Modulation. Multiple Zone & Circulator Control Manages 2 separate reset curves for high and low temperature zones: Controls up to 4 circulators. Manages 2 space heating zones and 1 DHW zone without external zone control panel. Intelligent Troubleshooting Describes lockouts in plain english and suggests solutions: Stores last 8 errors. Records sensor readings for 24 hours. Next Generation Fire Tube Heat Exchanger High Water Content · Provides stable temperature control · Low sensitivity to water flow · Reduces short cycling · Adapts to large or small heating loads Unique Geometry · Designed for maximum reliability with low thermal stress · Improved water flow for maximum heat transfer · 439 Stainless Steel for corrosion resistance · Polypropylene condensate pan and flue resists corrosion Reliable Low Maintenance Design · Self cleaning design washes away combustion debris · 1Oyear history of reliable performance · High performance burner design · Low pressure drop allows piping directly to the system eprestige - Leader in Contractor Friendl~ Features Prestige Solo 110 Exploded View Polypropylene Flue and Condensate Pan Eliminates corrosion from condensate ~ -- Integrated Circulator & DHW Supply on Solo 110 Model Simplifies piping and wiring Fold Down Control Panel Permits quick access to boiler internals Simplified Wiring Connections Wiring connections are well laid out and clearly marked. Fused high voltage connections makes trouble shooting easy The Widest Range of Venting and Termination Options Venting Terminations - 2", 3", and 4" diameters depending on model - Traditional PVC/CPVC/PP/SS piping elbows - PVC,CPVC, SS and Polypropylene materials - Flush-mount PVC for twin pipes - Flexible Polypropylene for chimney chases - Flush-mount Stainless Steel for twin pipes - Concentric (399 only) or twin pipe - Single hole Concentric Termination for twin pipes - Extended vent lengths up to 100 feet - Horizontal Concentric Termination.(399 only) -Common Vent for multiple boilers (399 only) - Horizontal and Vertical Common Vent Terminations (399 only) prestige · · Performance Specifications -- Model Fuel Input AFUE DOE NET Water : . Modulation Heating Capacity l=B=R Volume .. MBH MBH MBH Gal. Solo60 Natural or Propane 16 to 60 95% 54 47 2.5 Solo 110 Natural Gas 30 to 110 95% 99 86 2.5 Solo 110 LP Propane Gas 25to 97 95% 87 76 2.5 Solo 175 Natural or Propane 50to 170 95% 154 134 4.6 Solo250 Natural or Propane 65to245 95% 223 194 4.1 Solo399 Natural or Propane . 112 to 399 95.1 %* 379 330 7 Connect ions / Dimens ions / Data *Thermal Efficiency ~Model"'-'Supply I Return· ": Gas · ' ,Ventljl.ir - p1mensions Weight ~;t:.~-.z: ,·_.90~.~~;:!L'!r~s __~ c ~_grn~_st1~n,.:D)am_eter _ D ~w.x H Lbs ~ Solo 60 1" 112" 3· 16"x 20"x 35112" 95 Solo 110 1· 112" 3" 16"x 20· x 35 112" 106 Solo 175 11/4" 314· 3· 16"x 20" x 351/2" 131 Solo 250 11/4" 314· 3" 16"x 20"x 35 112" 142 Solo 399 1 112" 1· 4· 20 314"x 24 314· x 37 112" 200 TriM ax C ontr ol Features Standard Features large Graphic Interface .. Stainless Steel FireTube Heat Exchanger· 60 Second Set-Up ·EZ Access Terminal Strips with Individually·Customizable Reset Curves with 6 Presets Fused High VoltageTerminals ·Standard Modbus Interface ·Outdoor Reset Sensor ·2 Space Heating Call Inputs ..Negative Pressure Regulated Gas Valve Controls up to 4 Circulators ·LP Conversion Kit·0-10 VDC Modulation Input (All Models exceptSolo110) ·Outdoor Reset ·Cat IV Venting ·lockout Screens with Error Description and ·NPT Piping Connections Troubleshooting recommendations:·Integrated Pressure Gauge Cascade Control for up to 6 Boilers ·30 psi Pressure Relief Valve- Auto-configure linked boilers - Simultaneous space heating &DHW capability ..Automatic Air Vent- Full parallel modulation - Boiler rotation ..Fold-down Control Panel for Easy Access·DHW Priority ..Condensate Trap·Warm Weather Shutdown ·1OYear Non-Prorated Heat Exchanger·Low Water Cut Off Warranty ..2 Year Control &Blower Warranty Triangle Tube reserves the right to make product changes or Improvements at any time without notice. Company , ,.1 Triangle Lane Blackwood, NJ 08012'i TnangleTube Tei: (856) 228 8881- Fax: (856) 228 3584 E-mail: info@triangletube.com - http://www.triangletube.com 2011·48 Prestige Solo Lit- Revised 1/17/13 Iirect Water Heaters - Model ~ 30 40 40L 50 60 60L 80 .115 80-HO 115-HO 80-HO-C 115-HO-C Storage Volume (Gals.) 30 40 42 50 60 60 80 115 80 115 80 115 HUTOUTlfl TiPVAl.YE COM.CDlO INtfT Model 30 40 40L 50 60 60L 80 115 80-HO 115-HO 80- HO-C 115-HO-C Coil Piping Connections-N.P.T. Max. Heating Dimensions Domestic Surface (inches) Water Sa. Ft. Ht. Dia. In/Out 7.0 34.0 23.5 314 7.5 44.0 23.5 314 7.1 36.0 28.0 3/4 8.0 54.0 23.5 314 8.3 62.0 23.5 314 7.5 46.0 28.0 314 8.0 56.0 28.0 1 8.9 74.0 28.0 1 Hiah OUtDJt Units 80-HO and 115-HO 13.4 56.0 28.0 1 14.4 74.0 28.0 1 13.4 56.0 28.0 1 1/2 14.4 74.0 28.0 1 1/2 8.0 "ll~:HPT RECIRC.PORT llOURllETURN t tfT NPTHUTOUTlfT BOILER"-""1.Y 1 1/4. NPT 80llfRSUl'f'tY .. c::i .. 0 =""" 1 1/X'NPT DOM. CDlO INtfT 0-95 8.0 0........- 0- Boiler Water In/Out 1 1 1 1 1 1 1 1 1 1 11/4 1 1/4 Working Pressure (psi) 150 150 150 150 150 150 150 150 150 150 150 150 T_..VALYE 11/4. NPT llOll.ERllETURN _, ___ . STANOAAOUNITS Max. First Continuous Boiler Min. Boiler Pressure Hour Rating Rating Output Water flow Drop GalJHr.@ GalJHr.@ Reouired Throuah Coil ThrouahCoil 140F 115F 140F 115F fBTU/Hr.I Gal./Min. (Ft.Water} 195 259 168 232 125,600 14.0 5.3 215 284 179 248 134,200 14.0 5.7 195 259 168 232 125,600 14.0 5.3 234 308 189 263 129,900 14.0 6.0 254 333 200 279 151,000 14.0 6.2 233 302 179 248 134,100 14.0 5.7 266 341 194 269 145,600 14.0 6.0 319 403 216 300 162,400 14.0 6.6 High OutDut Units 80-HO and 115-HO 386 507 314 435 235,600 14.0 9.9 439 568 336 465 251,700 14.0 10.5 408 537 336 465 251,700 21.0 15.8 450 583 347 480 259,800 21.0 16.7 Note: All Ratings are based on 200 degree F boiler water supply and 50 degree F cold Water inlet. For 180 degree F boiler water supply multiply by ratings by 0.86 In the interest of continuous improvement, specifications are subject to change without notice. www.heat-flo.com Approx Shipping Wt.-Lbs. 85 100 100 110 125 120 140 175 155 190 155 190 ,· Project Information Project#: Name: Location: East B East B Davos Duplex Vail, CO 8,200' Project Summary Load Calculation Method: Design Location: OutdoorTemperature: Floorplans I Levels: Basement Main Floor Second Floor Total Area: Zone Heating Summary ® 2015 Dylan McCormick Ferguson Enteprise 550 Raritan Way Suite A Denver, CO 80204 Phone: 303-942-8102 Fax: 303-825-3562 Email:dylan.mccormick@ferguson.com Manual J8 (User Specified) Vail, Colorado -20.0 °F 924 ft2 1,124 ft2 1,184 ft2 3,232 ft2 Total Tubing Lengths: Barrier PEX 1/2" Total RH Circuits: Total Manifolds: Total Zones: Fluid Type: Total Tubing Volume: Heating System Summary Hlgldand Plumblna &Heatina, Inc. P.O. Box3697 Project #:East B Eagle.CO 81631-3697 October 19, 2017 Notes: 4,109 ft 19 6 6 100% Water 37.82 USG ComponentLosses: lnfiltrationNentilation: Radiant Back Losses: Total Heating Load: Radiant Heating: Radiant Back Losses: Other: Total Heating Load: 33,968 Btu/hr 16,035 Btu/hr 3,311 Btu/hr 53,314 Btu/hr 49,708 Btu/hr 3,311 Btu/hr 295 Btu/hr 53,314 Btu/hr Zone# Area Construction Heating Types RH Total Manifolds Flowrate Head Loss RH Load Supplemental Total Load Circuits Tubing 101 924 Embedded Slab RH 4 841 1 1.06 2.1 201 1,124 Gypsum Thin Slab RH 7 1,532 1 2.12 2.2 301 335 Gypsum Thin Slab RH,OTH 3 622 1 0.82 2.0 302 180 Gypsum Thin Slab RH 1 247 1 0.48 3.7 303 268 Gypsum Thin Slab RH 2 319 1 0.46 1.6 304 401 Gypsum Thin Slab RH 2 548 1 0.76 3.2 Total 3,232 multiple RH,OTH 19 4,109 6 5.70 3.7 Length = ft Area= 112 Temperature= °F Flowrate = USGPM Heat Loss = Btu/hr Unij Heat Loss = Btu/hr·ft2 Rv = hr·ft..°F/btu Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA = Forced Air OTH = Other Heating SM = Snowmelt N =Not Heated See end of report for important Notes and Disclaimers. 10,980 19,341 7,820 4,084 4,319 6,709 53,314 0 11,041 0 19,341 295 7,820 0 4,084 0 4,319 0 6,709 295 53,314 Created Using LoopCAD 2015 (1011912017) Version:15.0.0380 Page 1 of 3 Name:East B Davos Duplex ' Project #:East B Room Heating Summary (By Construction Type) Embedded Slab Zone# Room Name Heating Area Heated Manifold Type Area # 101 Garage RH 810 716 Manifold 1 101 Ski Room RH 114 104 Manifold 1 Gypsum Thin Slab Zone# Room Name Heating Area Heated Manifold Type Area # 201 Laundry Room RH 53 37 Manifold 2 201 living Room RH 975 709 Manifold 2 E200/Kitchen W202/Dining E205 201 Mud Room RH 52 47 Manifold 2 201 PowderRoom RH 45 33 Manifold 2 301 Master Bedroom RH,OTH 335 303 Manifold 3 E307 302 Master Bathroom RH 108 83 Manifold 4 E305 302 Walk-In Closet RH 47 42 Manifold 4 E306 302 Water Closet RH 25 20 Manifold 4 E304 303 Bathroom E302 RH 55 42 Manifold 5 303 Bedroom E303 RH 179 164 Manifold 5 303 Closet E301 RH 34 31 Manifold 5 304 Bathroom E310 RH 64 47 Manifold 6 304 Bedroom E309 RH 215 203 Manifold 6 304 Laning E300 RH 121 54 Manifold 6 RH Manifold Summary Tube Size 1/2" 112" Tube Size 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" Manifold Name #Zones #Circuits Flowrate Manifold 1 1 4 1.06 Manifold 2 1 7 2.12 RH Tube Total Floor Circuits Spacing Tubing Cover RV 3 12 602 0.0 1 12 207 0.0 RH Tube Total Floor Circuits Spacing Tubing Cover RV 1 12 159 0.3 6 6 1,302 0.7 1 12 159 0.7 1 12 159 0.3 3 6 602 1.2 1 6 237 0.3 1 6 237 1.2 1 6 237 0.3 1 6 148 0.3 1 9 158 1.2 1 9 158 1.2 1 6 255 0.3 2 6 535 1.2 1 6 280 0.7 Head Loss Required Supplied Temp. Temp. 2.1 97 100 2.2 120 130 Length = ft /Vea = ft2 Temperature = °F Flowrate = USGPM Heat Loss = Btu/hr Unit Heat Loss = Btu/hr·ft2 Rv = hr·ft2.°F/btu Required Unit RH RH Load Temp. Load 97 12.9 10,069 90 9.3 972 Required Unit RH RH Load Temp. Load 120 26.2 1,195 118 19.3 18,006 84 2.9 134 107 16.1 632 133 25 7,834 126 32.4 3,176 97 8.1 338 120 35.2 705 111 22.7 1,095 124 19.7 3,306 91 4.9 151 122 31 1,721 125 22.2 4,514 107 7.3 801 Temp Drop Manifold Type 20 (29) None Selected 20 (25) None Selected Heating System Summary October 19, 2017 Supplemental Total Load 0 10,069 0 972 Supplemental Total Load 0 1,195 0 17,446 0 98 0 601 295 7,820 0 3,092 0 306 0 687 0 1,057 0 3,135 0 127 0 1,686 0 4,307 0 716 Control Type #Actuators Manifold 0 Manifold 0 Head Loss = ft water RH = Radiant Floor Heating BB = Baseboard FA= Forced Air OTH = Other Heating SM = Snowmelt N = Not Heated Created Using LoopCAD 2015 (10/19/2017) Version:15.0.0380 See end of report for important Notes and Disclaimers. Page 2 of 3 Name:East B Davos Duplex ; Project #:East B Manifold 3 Manifold 4 Manifold 5 Manifold 6 Total Disclaimers 1 1 1 1 6 3 0.82 2.0 1 0.48 3.7 2 0.46 1.6 2 0.76 3.2 19 5.70 3.7 133 130 20 (19) 126 130 20 (22) 124 130 20(29) 125 130 20 (22) 133 - - None Selected None Selected None Selected None Selected - Heating System Summary October 19, 2017 Manifold 0 Manifold 0 Manifold 0 Manifold 0- 0 'Nith the permission ofthe Air Conditioning Contractorsof America \'ACCA'), material is reproduced fromManual J Residential Load Calculation (8th Edition) which is copyrighted by ACCA. The program and data are provided "as is" without warranty of any kind eitherexpressed or implied. The entire risk as the quality and performance ofthe programand data is with you. In no eventwill ACCA be liable to you for any damages, including without limitation any lost profits, lost savings, or other incidental or consequential damages arising out ofthe use or inability to use this program orthe data. © 2011 Air Conditioning Contractors ofAmerica. All Rights Reserved. www.acca.org ACCA, Manual J and Powered by ACCA Manual J are registered trademarks of the Air Conditioning ContractorsofAmerica. All rights reserved. Cold weather humidification, or some lifestylesthat produceexcessive moisture, may cause condensation to occur ifthe absolute humidity ofthe indoorair is too high for the momentary circumstances. Condensation can occuron surfaces or concealed within the structure, and can lead to mold, mildew, frost damage, and moisturedamage. The softwaredoes not perform calculations for the estimation or detection of possible condensation problems, and it is the designers ~.e.software users) responsibility to do so independently if required. For guidance and additional cautions refer to ACCA ManualJ 8th Edition, including Section 1-11 and Section 27. The calculated values shown in this report are based on the data input by the userof the software. Inaccurate or erroneous data input will result in inaccurate or erroneous results. You are strongly advisedto review all input data carefully, and to have the calculated results reviewed by an experienced heating professional to ensure reasonableness and suitability for your application. IN NO EVENT WILL AVENIR SOFTWAREINC. \ AVENIR") ORITS AFFILIATES BE LIABLE UNDER ANY CONTRACT, NEGLIGENCE, STRICT LIABILITY OROTHERLEGAL OR EQUITABLE THEORY FORANY CONSEQUENTIAL, INCIDENTAL, INDIRECTOR SPECIAL ORPUNITIVE DAMAGES WHATSOEVER(INCLUDING, BUT NOTLIMITEDTO, DAMAGES FOR LOSSOF BUSINESS PROFITS, BUSINESS INTERRUPTION, LOSSOF BUSINESSINFORMATION ORDATAAND THE LIKE), EVEN IF SUCH PARTY HAS BEEN ADVISED OFTHE POSSIBILITYOF SUCH DAMAGES. AVENIR'S CUMULATIVE LIABILITY FROMANY CAUSE RELATED TO ORARISING FROMTHE USETHIS REPORT, AND REGARDLESS OFTHE FORMOF THE ACTION, SHALL BE LIMITED TO NO GREATER THAN THE AMOUNTOF FEES PAID TO AVENIR UNDER THE SOFlWARE LICENSE AGREEMENT. Length = ti /Vea =IP Temperature= 'F Flowrate = USGPM Heat Loss = Btu/hr Untt Heat Loss = Btu/hr·fP Rv = hr·ft2.'F/btu Head Loss= ft water RH= Radiant Floor Heating BB = Baseboard FA= Forced Air OTH = Other Heating SM = Snowmelt N =Not Heated See end of report for important Notes and Disclaimers. Created Using LoopCAD 2015 (10/1912017) Version:15.0.0380 Page3 of 3